Text
{{#Wiki_filter:i ERPIP 4.1.2 Rev. 8, Ch.1 TITLE: SITE EMERGENCY COORDINATOR CHECKLIST 1.0 RESPON'SIBLE INDIVIDUAL The Site Emergency Coordinator (SEC)is responsible for the command of the ensite ( emergency organization including onsite and offsite emergency teams and the safety of all plant personnel and equipment, and for all actions necessary to
- mitigate the consequences of any emergency condition at CCNPP. The Shift Suoervisor (SS) is the interim SEC mtil relleved by the designated SEC.
-CAUTION-CN RECEIPT OF A REPORT OF AN EMERGENCY CONDITION OR EMERGENCY ALARM, ERPIP 3.1,IMMEDIATE ACTIONS, SHOULD BE PERFORMED FIRST. c.1 2.0 CONDITIONS AND PREREQUISITES ~ l Receipt by the Shift Supervisor of a report of an Emergency Condition and after l completing ERPIP 3.1, Initial Actions. ( 3.0 ACTIONS AND LIMITADONS (In the Control Room or the Emergency Control Center) -NOTE-Checklists are to be used as determined by the SEC. Spaces for Initials and times are to be utiH:ed, as necessary, to clarify the status. All pertinent action and commmications should be recorded in normal operating logs. 3.1 Enswe Implementation of ERPIP 3.1,Immediate Acdons and Emergency Action Levels, to classify the event. ERPIP 3.1 Implemented: / Initials Time l O*1 -NOTE-Ensure appropriate (nondelegatable) decisions (i.e. classification of l emergencies, making the decision to make initia1 notifications and j recommending protective actions are made and ensure release or evacuation I Dh5ho$$f7 0 PDR 4.1.2-1 i 1 ~
ERPIP 4.1.2-Rev. 8, Ch.1 of site personnelis per ERPIP 4.5.1. Record pertinent actions and data on 01 EMERGENCY ACTIONS FORM, found in App. B.3. 3.2 Activate emergency teams listed on EXHIBIT 4.1.2-A, EMERCE.NCY TEAM ACTIVATION FORM, as necessary. ^ Emergency Teams activated: / Initials Time -NOTE-Recall purchasing and stores personnelif ad,iltional equipment or supplies are needed. See Appendix A.1 for phone numbers. m.1 3.3 Direct the Radiation Protection Director (RPD) and the Radiologimi Assessment Director (RAD) to initiate ERPIP sections 4.3.1 and 4.3.2 If an actual or projected gaseous radioactive release has occurred or suspected to have occurred. ~ I ERPIP 4.3.1 & 4.3.2 Initiated: / Initials Time -NOTE-The Shift Supervisor,in the capacity of interim SEC, must initiate immediate i action procedures, (ERPIP 3.1) as necessary. Ch.1 3.4 Implement or direct implementation of additional ERPIP sections, as appropriate,in accordance with EXHIBIT 4.1.2-B, ERPIP IMPLEMENTATION FORM. 3.5 Activate emergency facilities listed on EXHIBIT 4.1.2-C, EMERGENCY FACILITIES ACTIVATION FORM, as necessary. 3.6 Make all notifications using ERPIP 3.1 Att. I to offsite EOCs on Initial g upgraded or downgraded emergency classification. 3.7 Move to AECC (Farm Demo Bldg) upon declaration of site emergency if f appropriate. 3.3 Coordinate operations with the Operational Support Center (OSC), as i required, to augment operations staff. I 3.9 Provide the Technical Support Center (TSC) with technical support Information concerning plant conditions, as necessary. l -NOTE-In order to ensure open IInes on the paging system during an emergency situation, whenever the TSC is activated, lines 4 and 5 shall be ieserved for commurdcations between the TSC, O'SC, Control Room and ECC. 4.1.2-2
El(PIP 4.1.2 Rev. 8 3.10 Consult RAD prior to making recommendations to offsite agencies, as required per ERPIP 4.5.6 I 3.11 For General Emergencies review Exhibit 4.5.6-F for plume exposure EPZ evacuation recommendations. .~ 3.12 Implement ERPIP 4.9, Recovery,if the conditions of the Recovery Checklist have been met. ERPIP 4.9 Implemented. / Initials Time -CAUTION. EVEN IF PROJECTED OR MEASURED DOSES IN AREAS ADJACENT TO THE PLUME DO NOT REQUIRE EVACUATION, BECAUSE OF POSSIBLE WIND SHIFTS AND UNCERTAINTIES, CAREFULLY EVALUATE THE USE OF MEDIA WARNINGS AND PRECAUTIONARY EVACUATIONS IN THESE AREAS. 3.13 Recontact onsite and offsite emergency personnel previously can'tacted and Inform them that emergency is terminated. -CAUTION-( 1. WHEN ASSUMING A KEY PERSONNEL POSITION, REQUEST A BRIEFING ON THE EMERGENCY AND EMERGENCY ACTIONS STATUS FROM THE PREVIOUS POSITION HOLDER. / Initials Time 2. WHEN RELINQUISMING A KEY PERSONNEL POSITION, BRIEF YOUR SUCCESSOR ON THE EMERGENCY AND EMERGENCY ACTIONS i STATUS. BRIEFING GIVEN: / Initials Time 3. NOTIFY ALL APPROPRIATE PERSONNEL OF YOUR NAME, THE KEY PERSONNEL POSITION YOU ARE ASSUMING, AND THE NAME OF THE PERSON YOU REPLACE. I APPROPRIATE PERSONNEL NOTIFIED / Initials Time 3.14 Continuously evaluate plant conditions to ensure compilance with technical specification criteria, AOP & EOP Implementation criteria, and to make recommendations to the Plant Superintendent to reclassify the emergency, as necessary. 3 4.1.2-3
ERPIP 4.1.2 Rev. 8, Ch.1 EXHIBIT 4.1.2-A MERGENCY TEAM ACTIVATION FORM (SEE NOTE), Radiation Protection Director, Radiological Assessment Director and Emergency C Radiation Teams (See note below). Activated: / Initials Time Emergency Fire Team Leader Activated: / Initials Time Emergency First Aid and Decontamination Team Leader Activated: / Initials Time Emergency Security Team Leader Activated: / Initials Time Emergency Reentry Team Leader Activated: / Initials Time Emergency Repair and Damage Control Team Leader Activated: / Initials Time Emergency Recovery and Restoration Team Leader Activated: / Initials Time -NOTE-1. For Alert, Site or Genera 1 Emergency classes, all emergency response positions and teams must be activated. 2. For a Radiologica1 Event the RPD, RAD, and OFMTL must Ch.1 be activated, as a minimum. 4.1.2-4 j
ERh!P 4.1.2 t Rev. 8, Ch.1 ( EXHIBIT 4.1.2-B l ERPIP IMPLEMENTATION FORM i I Emergency Condition + Imolement ERPIP Section Time imolemented l ff PersonnelInjiry 4.6 Aid to Affected Personnel l A.2 Emergency Support Trans-c.1 portation j If PossiMe Contamination 4.3.4 Pmw 4 Contaminadan Monitoring 4.5.5 Personnel Decontaminaden O1 If Possible Gaseous 4.3.1 Offsite Gamma and Mobile l Release (If Airborne Air Sample Surveys l. Radioactivity) 4.3.2 Onsite Gamma Mobile Air Sample Surveys 4.4.8 Ground Deposition (Scil l [ l Contaminaticm) l 4.4 Assessment Actions 4.5.2 Access Control 4.5.3 Respiratory Protecdon 4.5.4 Radioprotective Drugs Administradon 4.5.6 offsite Proteedve Actions If PossibleLiquid 4.3.3 . Liquid Effluent Aedvity Sampling and Analysis 4.5.2 Access Control If Possible Core 4.4.7 Means of Estimating Damage Post-Accident Core Damage 4.5.2 Access Control If Posible Plant Area 4.5.1 Onsite Personnel Protect-p Protective Actions tion, Accountability & I Eiacuation 4.1.2-3 a
ERPIP 4.1.2 Re'v.8,Ch.1 ..) EXHIBIT 4.1.2-B, continued,. ERP!P IMPLEMENTATION FORM Ch.1 4.8 Emergency Reentry c E i-4.9 Recovery & Restoration t 9 REVIEW ALL EMERGENCY CONDITIONS AND IMPLEMENT ERPIP SECTIONS (AND SUBSECTIONS) AS DETERMINED APPROPRIATE. I l '\\ ..I s '+ s s 4 U i 5-3 - h t l l 4.1.2-6 m )s %
1 ERP!P 4.1.2 j Rev. 8, Ch.1 i EXHIBIT 4.1.2-C - EMERGENCY FACII.ITIES ACTIVATION FORM Emergency ControlCenter Activated: / C Initials Time Technical Support Center Activated: / Initials Time Operations Support Center Activated: / Initials Time Calvert County Emergency Operations Center Activated: / Initials Time Media Commtmications Center at Calvert County Fairgrounds Activated: / Initials Time ' St. Mary's County Emergency Operations Center Activated: / Initials Time Dcrchester County Emergency Operations Center Activated: / Initials Time Maryland Civil Defense & Disaster Preparedness Agency Activated / Initials Time INPO & ANI call (for Alert, Site or General Emergencies): (See Appendix A.2 for phone no.) / lC1.1 Inittais Time -NOTE-
- When activated, make Follow-up Communications per ERPIP 3.1, Att. 3.
01.1 l .I J t,, [; -s i s t -j \\s s l 4.1.2-7 ?l -,N.
f i. a l
- l i
i ERP!P 4.1.2 REVIEW / APPROVAL 1 REVISION CHANGE REVIEWER SIG/ SUPERVISOR POSRC PLANT SUPERINTENDENT l DATE EPU SIG/DATE MTG /DATE 8 1 U4h**** % %.a.a 83-I18 G(% ioluhs a o 1 J i l -~ e. i l ~f 1 l .1 1 i -{ I e J 3 +,
1 ERPIP 4.1.2 l Rev. 8, Ch. I 1 ,) 1.15T OF EFFEC 11VE PAGES PAGE NUMBER REVISION 4.1.2-1 8,Ch.1 C 4.1.2-2 8,Ch.1 4.1.2-3 8 4.1.2-4 8,Ch.1 4.1.2-5 8,Ch.1 4.1.2-6 8, Ch.1 4.1.24 8, Ch.1 l l l I s, ~ i I i l l f e
- 9,
/ l -e '1: .e e
1 l I ERP!P NO 4.1.5 Rev. 3, Ch.2 ) TITLE: RADIATION PROTECTION DIRECTOR CHECKLIST 1.0 RESPONSIBLE INDIVIDUAL The Radiation Protection Director (RPD)is responsible to the Plant Superintendent C (PS) for: 1.1 Performance of radiation surveys inplant and onsite (ERP!P 4.3.2). 1.2 Obtaining appropriate liquid and gaseous samples for radioanalysis, including post-accident sampling of containment atmosphr.re and reactor coolant (ERPIP 4.3.3, 4.4.7.2, 4.4.7.3). 1.3 Establishing controlled access areas to contain or limit the spread of contamination (ERPIP 4.5.2). 1.4 Prescribing protective equipment and clothing to personnel (ERP!P 4.5.3, 4.5.4.1). 1.5 Establishing and posting radiation and contamination (coner 'ed) area boundary requirements (ERP!P 4.3.2). 1.6 Personnel monitoring and exposure evetuation (ERP!P 4.3.4, 4.5.5). ,.('* 1.7 Providing quallfled personnel to be members of the Emergency Reentry Team (ERPIP 4.3). 1.3 Directing the activities of the Emergency Reentry Team during the initial emergency reentry (ERPIP 4.3, 4.3.1). 1.9 Directing the activities of "mergency First Aid and Decontamination Team during Alert, Site Emergency and General Emergency. 1.10 Assessing the need for and distribution of Radioactive Drugs (ERPIP 4.5.4) 2.0 CONDITIONS AND PREREQUISITES 2.1 Declaration of an Alert, Site Emergency or General Emergency 2.2 Detection of a Radiological Event Ch.2 2.3 As directed by the Plant Superintendent 3.0 ACTIONS AND LIMITATIONS On Emergency Control Center, Technical Support Center, Radiation Safety Laboratory, as appropriate.) -NOTE-Review ERPIP 4.0 when assuming or relinquishing a Kay Personnel position. Checklists are to be used as determined by the RPD. Spaces for initials and times are to be utilized for initial actions, as necessary, to clarify the status. Utilize Emernency Actions Forns (App. B.3) to doctrnent all repetitive ac+1ons taken. Ch.2 4.1.51
ERP!P No a.l.5 1 Rev. 8, Ch.2 3.1 Announce to the other emergency workers your name and that you are the RPD. 3.2 Receive briefing from P5 on existing plar.t or site conditions and record the Emergency Action Level (EAL) classification below (write "none" If no EAL has been met): EAL Classificatiom / Received Sriefing: Iniuals Time 13 Use EXHIBIT 4.1.5-A, ERT ACTIVATION PRIORITY & ASSEMBLY FORM to determine which Emergency Radiation Teams must be activated (in the order IIsted on the form) and to record the data. Emergency Radiation Teams Recorded on EXHIBtf 4.1.5-A: / Initials Time -NOTE-All Emergency Radiation Teams must be activated for Alerts, Site Ch Emergencies and General Emergencies. For a Radiological Event the Offsite j Monitoring Teams (activated by the Radiological Assess, ment Director) and Onsite M' onitoring Teams must be activated, and others as necessary. 3.4. Ensure that the required Emergency Radiation Team members are notifled as identifled in Appendix A.1, Emergency Organization Members and Telephone . Numbers, and enter data on EXHIBIT a.l.5-A. Teams Members Notified and Data Recorded on EXHIBIT 4.1.5-As / ~ Ininals Time -NOTE-The Emergency Radiation Team Leaders may be delegated the responsibility to notify their respective team members. 3.5 Require the Emergency Radiation Team members to assemble at a designated assembly area. 3.5.1 Report the availability of the teams to the PS. Emerger.g Radiation Teams Availability Reported to PS: / Initials Time N.- G e 4.1.5-2 / e
8 ERPil NO 4.1.5 Rev. 8, Ch.2 3.5.2 Record the assembly area and accountability information on EXHIBIT 1 4.1.5-A. -NOTE- ~ Assembly Area is the Operational Support Center. In order to ensure Q.2 ' open lines on the page during an emergency situation, wherever the Technical Support Center is activated, lines 4 and 5 shall be reserved for communications between the Technical Support Center, Operational Support Center, Con.rol Room, and Emergency Control Center. Accountability Recorded: / j Initials Time i i 3.6 Have the ECC Monitoring Team Leader implement ERPIP 4.3.4 and use the Emergency Monitoring Kit to evaluate the need to evacuate the ECC and the Radiation Safety Laboratory. Possible Evacuation evaluated and ERPIP 4.3.4 Implemented: 1 / Initials Time ( -NOTE-Have periodical re-evaluation of evacuation possibilities when radiological conditions warrr nt. 3.7 Brief Emergenc ; Radiation Team Members on the following (as appropriate): Anti C's Respiratory Requirements Areas to Check Plant Conditions Expected Dose Rates Planned Stay Time / Total Dose Precautions l Proper Dosimetry l Procedures to be Used Other Specific Instructions (List Here) %en 4.1.5-3 4 - -~ 3
] ERPIP 4.1.5 Rev.8 1 Emergency Radiation Team Members Briefed: / Initials Time 'I 3.3 Brief ERT members on emergency exposure criteria In accordance with ERP!P 4.6.1 whenever potentially high exposure levels may exist (known or unknown). ERT Members Briefed: / Initials nme -NOTE-The emergency exposure criteria described in ERPIP 4.6.1 delineate the fonowing areast (1) recommended personnel, (2) planned doses for lifesaving actions, and (3) planned doses for faculty protection actions. All other exposures, must be maintained in accordance with RCP 3-300 series procedures. 3.9 Enswe each team member Is equipped with the following proper protective-clothing and equipment: -NOTE-Equipment requirements wul vary depending on Individual assignments. j Unnecessary use of protective equipment should be avolded. 3.9.! Protective Clothing Requirements sood Coveralls (1,2 ;eir) Paper Suit Cotton Gloves Rubber Gloves Rubber Overshoes l Plutic Shoecovers Plastic Pants Other 3.9.2 Respiratory Protective Device MSA with Particulate Futer SCBA Type l 3M Back Pack l-3M Economy Hood s.1.u
't ERPIP 4.1.5 Rev. 3, Ch. 2 3M Soft Cap Other 3.9.3 Personnel Monitoring and Survey Instrumentation TLD and SRD High Range SRD (0 5R,0-10R,0-100R,0-200R) Special (RCP 3-303 4.5) Gamma Exposure Rate Meter (0.1 R/h to 20 KR/h) Neutron REM-Ball Neutron Dosimeter A4 arming Dosimeter (0-200R) i Portable Air Samplers (4 h power supply - minimum) j Team Members Equipped: / Inittais Time -NOTE-Assign tasks to the Emergency Radiation Teams in accordance with the priority list EXHIBIT 4.1.5-A. Record all assigned tasks on (., EMERGENCY ACTIONS FORM (App B.3). Ch.2 3.10 If the nature of gaseous release Indicates the potential for significant levels of iodine (greater than 40 MPC-h of exposure is possible), consider immediate administration of radioprotective drugs to all affected onsite emergency personnelin accordance with ERPIP 4.5.4.1 if adequate respiratory protection devices are not available. 3.11 If a release of airborne radioactivity is detected, immediately dispatch at least one Onsite Monitoring Team in accordance with ERP!P 4.3.2. 4 ERPIP 4.3.2 Inititted: / Initials Time -NCTE-If a release of radioactivity is detected, the only dekay allowed for the Onsite Monitoring Teams is an operational check of exposure rate metets which should take 2 minutes at most. 3.12 Have radiation surveys performed in Assembly Areas and around the. Protected Area Fence. 3.12.1 Record results on EMERGENCY ACTIONS FORM, (App. B.3). Ch.2 l 4.1.5-5 w
ERPIP 4.1.5 Rev.3,Ch.2 3.12.2 Notify P5 of the results. Surveys Performed and Results / Reported to PS: Initials Time 3.13 Establish control points as necessary. 3.13.1 Record access control point locations on EMERGENCY ACTIONS Ch.2 FORM. (App. B.3). 1 13.2 Report results to the PS. Access Control Points Established and PS Nofitied: / Intials Time 3.14 Have gaseous and air particulate samples analyzed per ERPIP 4.3.2. Ch 2 1 14.1 Record results on EMERGENCY ACTIONS FORM, (App. B.3). 3.14.2 Notify P5 of the results. Samples Analyzed oc Results / Reported to PS: Initials Time 1 15 Notify RAD of air sampling results obtained Inplant and onsite. ./ Initials Time 1 16 Restrict access into Auxillary Building or other potential high Radiation Areas by unauthorized or unprepared Individuals to hazardous radiation environment. 1 16.1 Establish positive access control by instituting the use of Emergency Work Permits (ERPIP 4.3.1) for all Controlled Area entries during the occurrence, emergency and recovery phases of the accident. Positive Access Control Estab'Ished - / Initials Time 1 17 When notified by one of the following: (check one) ( ) Control Room ( )TSC ( )RhD ( ) R 202 Alarm (on IC07 or 2C07 board) Have the LRMT and REMT members prepare to perform Post-Accident Reactor Coolant Sampling per ERPtP 4.4.7.1 1 17.' Commence monitoring per ERPIP 4.4.7.3 rec"trements. 4.1.5-4 J
1 1 ERPIP 4.1.5 Rev. 8, Ch. 2 - CAUTION - Review App. B.2, pages B.2-7 tnrough B.2-11, " POST Accident Radiation Doses (Aux. Bldg.)," Area Monitor (R/h) Alarms and other ava!!able Information to determine accessible and appropriate routes to ingress / egress R/C Sampling Room. 3.17.2 Report analysis results to PS, RAD & TSC Immediately. (Initial mR/h at 1 ft. from RCS sample to be reported immediately after obtained). Reported Results to ( ) PS ( ) SEC ( ) RAD ( ) TSC / Initials Time 3.18 Consult with the RAD and the PS and implement the following as necessary: 3.18.1 Mave liquid effluent samples collected, analyzed per ERPIP 4.3.3. Results Recorded on ERP!P 4.3.3, Attachment 1 and Reported to SEC: Ch.2 s / Initials Time -NOTE-If the discharge concentration of Gross Beta and/or Tritium is greater than the intake concentration by a f actor 10, the RPD, as directed by a the SEC shall: l. Warn persons away from the Circulating Water discharge. /- Persons Warned: Initials Times 2. Notify the Maryland Department of Health and Mental Hygiene. l Maryland Department of Health & Mental Hygiene Notified: / Initials Time 2 l I s._- l 4.1.5-7 l l
ERP!P 4.1.5 Rev. 8, Ch. 2 ~ 3. As necessary, contact the Maryland Marine Pol!ce (see Appendix A.2) and request assistance in evacuation of portions of Ch.2 Chesapeake Bay. C Marine Police Contacted: / Inittais Time 4 Notify the Director - Environmental Studies & Monitoring at BG&E to commence an intensive monitoring program. BG&E Chief Env. Engr. Notifled: / l Initials Time 5. Institute measures to determine the source of contamination and mitigate releases. Meastres to Determine Sources & Mitigate Releases Implemented: l \\ y Initials Time (_ 6. Monitor releases and review EAI.s In ERPIP 3.1 to determine need Ch.2' for E.T. gw.cy classification. If EALs have been met or are being approached, confer with the PS to determine appropriate actions. l l 3.1L2 Have Containment Atmosphere sampled per ERPIP 4.4.7.2. Results Recorded on EMERGENCY ACTIONS FORM, (App B.3) and Ch.2 R.f~.Ied to PS: / Initials Time 3.18.3 Have RCS 3amples taken per ERPIP 4.4.7.3.
- Results Recorded on EMERGENCY ACTIONS FORM, (App. B.3) and Ch.2
/ l Reported to PS and RAD: __. Initials Time l l -NOTE- ~ Repeat RCS Sampling on a routine basis (every hour) as necessary, to i determine activity levels and trends. (.,- 4.1.5-8 s
ERP!P 4.1.5 Rev.8,Ch.2 3.19 Determine the inplant and onsite projected exposure durations by obtaining expected time for continuous release from Control Room and notify the PS and RAD. PS and RAD Notified of Projected Exposure Duration and resuits Recorded on EMERGENCY ACTIONS FORM (App. B.3): Ch.2 / Initials Time 3.20 Direct the repetition of radiological surveys and RCS, Cire Water, and Containment Samples as necessary to determine release projected dose trends at the Protected Area Fence, Site Boundary or into Bay. -NOTE-It is important to obtain confirmation data and to determine trends. Record all results, both positive and negative, on EMERGENCY ACTIONS FORM Ch.2 (App. B.3) as determined, and report them to the PS as described above. Projected Dose Trends Deterrnined and Results Reported to PS and RAD: / Initials Time e 0 4.1.5-9
ERPIP 4.1.5 Rev. 8, Ch. 2 ') ~ EXHIBIT 4.1.5-A ERT ACTIVATICN PRIORITY & ASSEMBLY FORM C Notifled Assembly Accountability of Priority ERT ( if Yes) Point Teams and Members 1. Offsite Monitoring Team *, # (2 individuals / team) 2. Onsite Mmitoring Team # (2 individuals / team-add to when manpower becomes available) 3. Assembly Area Monitoring Team 4. Gate and Access Monitoring Team 5. ECC Monitoring Team (May l Initially be combined with Assembly Area Monitoring Team) 6. Liquid Release Monitoring Team (_ 7. Emergency F/A and Decontamination Team S. Emergency Reentry Monitoring Team 9. Dosimetry Team
- Activated by the Radiologimi Assessment Director (ERPIP 4.1.15)
- Mandatory activation for Unusual Event or higher emergency classes if radiological event occurred. Negative findings are important to identify.
Ch.2 I -CAUTION-INDIVIDUALS SHALL NOT BE ASSIGNED TO PERFORM TASKS OF A TEAM UNLESS ALL ASSEMBI.ED TEAMS HIGHER ON THE LIST ARE MANNED BY ASSIGNED TEAM MEMBERS (NOT INTERIM MEMBERS). UPON FULL AUGMENTATION, ALL EMERGENCY TEAMS MUST BE ACTIVATED AND PREPARED TO PERFORM THEIR ASSIGNED RESPONSIBE.ITIES. l ~ 4.1.5-10 ~,
G l O I g ERPIP 4.1.5 REVIEW / APPROVAL l REVISION CHANGE REVIEWER SIG/ SUPERVISOR POSRC PLANT SUPERINTENDENT ) DATE.c-EPU SIG/DATE MTG /DATE A l= * ?$ Y l? $$ e 1 CA % =*MW,o.an a>ue c a u s J, J u p I am. G e I a. em 4 up 4 m. O \\ e e e3 s em t 8 i I 6 em 4 'O e_ 6 j. 1 u i
ERPIP 4.1.5 Rev. 3, Ch. 2 1.15T OF EFFECTIVE PAGES P PAGE NUMBER REVISION 4.1.5-1 3, Ch. 2 4.1.5-2 3, Ch. 2 E.1.5-3 3, Ch. 2 4.1.54 3 4.1.5-5 3, Ch. 2 4.1.5-6 8,Ch.2 4.1.5-7 8, Ch. 2 i 4.1.5-8 8, Ch. 2 l 4.1.5=9 8, Ch. 2 4.1.5-10 8,Ch.2 e e S e 1 4 l-l = 9 6 l
ERPIR 4.1.6 Rev. 9, Ch.1 TITLE: OFFSITE MONITORING TEAM LEADER CHECKLIST 1.0 RESPONSIBLE INDIVIDUAL The OFMTL is responsible to the RAD to monitor offsite gaseous radiological ~ releases during emergencies for the purpose of minimizing personnel exposure and preventing unnecessary spread of contamination. 2.0 CONDITIONS AND PREREQUISITES Then directed by the RAD or SEC. CM 3.0 ACTIONS AND LIMITATIONS On the ECC or offsite at a survey point determined by the RAD or at ERT Mobile Monitoring Unit). -NOTE-Checkilsts are to be used as determined by the OFMTL. Spaces for initials and times are to be utilized, as necessary, to clarify the sta:us. 3.1 As the initial action, announce to the other emergency worxers who you are and that you are the OFMTL. Announced: / Initials Time 3.2 Obtain initial briefing from SEC, RAD, or the person you replace. Briefed: / Initials Time 3.3 Have OFMT members obtain appropriate dosimeters based on anticipated radiation levels. Desimeters Issued: (Range) / Initials Time 3.3.1 Record each assigned OFMT members' name, TLD# on RCP-3-301-1, Calvert Cliffs Weeldy Dosimeter Record (Attachment 1). 4.1.6-t
ERP!P NO.: 4.16 / REV; 9 - Use preapproved EWPt/ 006 (less than 3.000 rem /gr), EWPd 007 i l (greater than 3.000 rem /gr, but less than er ecual to 100 rem acute l exposure) or new EWP. - CAUTION - 5 l WOMEN CAPABLE OF REPRCOUCT!CN SHALL NOT TAKE PART l I IN EMERGENCY EXPOSURE LIMITS (EWP #007) GREATER THAN 3.000 REM /QTR. 3.3.2 Obtain previous radiation exoosure during current calendar quarter for assigned CFMT members from the DTL and record on RCP 3-301-
- 1. (Attachment 1)
( - NOTE - .) l Items 3.3.1 thru 3.3.2 may be accomplished via radio or l other communications after departure of OFMT to l monitoring locations, but.s to be accomplished as soon J l as posstble to track team members radiarien exposure j status. 3.3.3 Based on radiological conditions, periodically contact OFMT members, obtain SRO readings, and record on RCP3-301 1 (Attactment 1). Have team member (s) rezero their SRC's after each 1 time SRO readings have been recorded. i 3.3.4 Report OFMT members (s) current accumulated exposures to RAD. 4.1.6-2
.m I l ' ' * ;5 ..t** .e a. st , ' * ( *- .~
- =. 4 }, *.~' *: -
~- . u s. e..
- s..
7, s....-... -.
- .e
+. ,,t ..s c.. ~ u. .a ..r ..a IR?I? 4.1.6 RETITJ/ APPROVAL ?. .. ~. .~- 3 .z 1, J MY!SION CMANGE REVIEWER SIG/ SUPERVISOR POSRC PLANT SUPERINTENDENT DAT.E EPU SIG/DATE MTG /DATE Yb7;ba.s.u 07/ sci idv1LGD 4R La! a re2-4 9 i e/A tonM '. ibh,J<s es-tzs & TL..co ic dr3 i '4 j I I-f( l b e I i l .I l 4 I l l .r e ..t.
- 3..
~ .,,., j,,. r. *, r .7
- i
. p y c. y __h,.. . o )
i [ i ERPIP 4.1.6 Rev. 9, Ch.1 ) 1 l UST OF EFFECTIVE PAGES I PAGE NUMBER REVISION r 4.1.6-1 9,Ch.1 C l \\ 4.16-2 9 4.1.6-3 9 1 4.1.6-4 9 1 1 1 t t 6 i .) O a 4 e k i l l, 4 a f 4 I I d J e - -.,, < -.. - = -.me -e -a -=.e = wien,. -r-- m =- e 3 r e sr +r%w e' wee en- ,'en,wr e.- 9+-4 k y4 z+ n m--- T-
- --W
ERPIP 4.1.7 Rev'. 8, Ch.1 TITLE ONSITE MONITORING TEAM LEADER CHECKLIST 1.0 RESPONSIBLE INDIVIDUAL The ONMTL is responsible to the RPD to monitor onsite and inplant releases during ~ emergencies for the purpose of minimizing personnel exposure and preventing ~ unnecessary spread of contamination. f 2.0 CONDITTONS AND PREREQUISITES When directed by the RPD or SEC. Ch.1 3.0 ACTTONS AND LIMITATIONS (Onsite at a survey point determined by the RPD and in radio contact with ECC). -NOTE-Checklists are to be used as determined by the eerson in charge. Spaces for Initials and times are to be utilized, as necessary, to clarify the status of actions. 3.1 Announce to the other emergency workers, who you are and that you are the (' ONMTL. Announced: / Initials Time 3.2 Obtain initial briefing from the RPD or the person you replace. Briefed: / Initials Time 3.3 Obtain appropriate dosimeter (s) based on anticipated radiation levels. Dosimeters issued: (Range) / Initials Time 3.4 Proceed to designated monitoring points as directed by the RPD and implement ERP!P 4.3.2. ERP!P 4.3.2 Implemented: / Initials Time 4.1.7-1 l l
ERP!P NO.: 4.1.7f REV. 6 DATE: November 16, 1981 m. -NO TE-1. As per ERP!P 4.3.2, pick tp radio-telephone (e.g. walkie-talkie) and Emergency Monitoring Kit at the ECC. 2. Operate equipment with battery power supply conservatively. 3. Ensure accurate and detailed records are made of all radiation levels and air sample surveys and results are communicated to the RPD. (Forms and EXHIBITS found in ERP!P 4.3.1). Record and report all results, both positive and negative. 4. All entries into the Controlled Areas must be made under the emergency RWP designated by the RPD. -CAUTION-1. WHILE PROCEEDING THROUGH AREAS OF UNKNOWN RADIATDN LEVELS, CONTINUOUSLY MONITOR AS APPROPRIATE TO ENSURE SAFETY. i i 4.1.7-2
= l l l l ERP!P 4.1.7 REVIEW / APPROVAL ' REVISION CHANGE REVIEWER SIG/ SUPERVISOR POSRC PLANT SUPERINTENDENT DATE EPU SIC /DATE MTG /DATE h' Y !c.ites 85-f29 Q (b h a Icly,l75 I Y Y d / / O F 9 4 e e d I e 9 e O
ERMP 4.1.7 Rev. 8, Ch.1 UST OF EFFECTIVE PAGES E PAGE NUMBER REVISION 4.1.7-1 3, Ch.1 ( 4.1.7-2 6 l l l l ,o 0 l l i I l l l f i = --g. u q.+
i ERP!P 4.1.9 Rev.3,Ch.1 TITLE: ASSEMBLY ARE1 MONITORING TEAM LEADER CHECKLIST 1.0 RESPONSIBLE INDIVIDUAL The AAMTL Is responsible to the RPD and SEC to perform assembly area and/or perimeter control point and personnel monitoring during emergencies for the purpose of minimizing personnel exposure and preventing unnecessary spread of contamination. 2.0 CONDITIONS AND PREREQUISITES When directed by the RPD. 3.0 ACTIONS AND LIMITATIONS (In designated assembly areas or at perimeter control point) -NOTE-Checklists are to be used as determined by the AAMTL. Spaces for Initials and times are to be utilized, as necessary, to clarify the status. 3.1 Obtain initial briefing from SEC, RPD, or the person you replace. Briefed: / Initials Time 3.2 Obtain appropriate dosimeters (based on anticipated radioactivity levels) and proper communications equipment. 3.3 Obtain and/or check (per ERPIP 5.3) appropriate emergency monitoring equipment, maps, and forms as required in the ERPIP (see Appendix B.1 through B.3). 3.4 Proceed to designated monitoring points as directed in ERPIP Appendix B.2-6, 4.3.4, 4.5.1. g -NOTE-1. Operate equipment with temporary power sources conservatively. 2. Ensure accurate and detailed records are made of radioactivity and/or contamination levels and that results communicated to the RPD are properly understood. 3.5 Direct contaminated individuals to appropriate decontamination stations as l necessary per ERPIP 4.5.5. (, 4.1.9-1 l
1 ERPIP NO.: 4.1.3 / R E V. 6 DATE: November 16, 1981 3.6 Assist Gaid and Access Monitoring Team as directed by RPD. -CAUTION-1. WHILE PROCEEDING THROUGH AREAS OF UNKNOWN RADIOAC11VITY LEVELS CONTINUOUSLY MONITOR AS APPROPRIATE TO ENSURE SAFETY. t D e e i l l l l l l 4.1.9-2 l
1 ERPIP 4.1.9 REVIEl/ APPROVAL REVISION CHANGE REVIEWER SIG/ SUPERVISOR POSRC PLANT SUPERINTENDENT DATE EPU SIG/DATE MTG /DATE 0 $$&#A'h $ k io.ia.6 85-12b 0 Q a}} /sl2.tl5 y E e e e o e b p i I e e 9 emme G G G 1
ERPIP 4.1.9 Rev. 8, Ch.1 UST OF EFFECTIVE PAGES PAGE NUMBER REVISION 4.1.9-1 3, Ch.1 4.1.9-2 6 C l l l ] ./ y e l I l
ERP!P 4.f.10 t Rev.3,Ch.1 TITLE: GATE AND ACCESS MONITORING TEAM LEADER CHECKLIST s 1.0 RESPONSIBLE INDIVIDUAL The GAMTL is responsible to the RPD to monitor personnel and/or vehicles exiting the protected area or the perimeter control point during emergencies, preventing ' } unnecessary spread of contamination. 2.0 CONDITIONS AND PREREQUI5ITES When directed by the RPD. s ^ 3.0 ACTIONS AND LIMITATIONS Qn the Guard House or at the perimeter control point) -NOTE-Check 11sts are to be used as determindeo by the GAMTL. Spaces for initials and times are to be utilized, as necessary, to clarify the status. 3.1 Obtain initial briefing from SEC, RPD, or the person you replace. ( Briefed: / s Initials Time 3.2 Obtain appropriate dosimeters (based on anticipated radioactivity levels) and proper communications equipment. 3.3 Obtain and/or check (per ERPIP 5.3) appropriate emergency monitoring equipment, maps, and forms as required in the ERP!P (see Appendix B.1 through 3.3). 3.4 Proceed to designated monitoring points as directed in ERPIP 4.3.4, 4.5.1. Ch.1 -NOTE-l. Operate equipment with temporairy power sources conservatively. l 2. Ensure accurate and detailed records are made of radioactivity and/or contamkation levels and that results communicated to the RPD are properly understood. 3.5 Direct contaminated Individuals to appropriate decentamination stations as necessary per ERP!P 4.5.5. 4.1.10-1 v
. _.. - 7 s 1 x 1 ERPIP NO.: 4.1.10 / REV. 6 DATE: November 16, 1981 -C AU TION-1. WHILE PROCEEDING THROUGH AREAS OF UNKNOWN RADIO ACTIVITY LEVELS CONENUOUSLY MONITOR AS APPROPRIATE TO ENSURE SAFETY. s 1 i x ~ ~ km. h ( ) w 9 ) i s kg 4 9 i g D 1 b\\ t t .s l i e 4.1.10-2 w
,m _a -.uw ~- 0 1 I i 5 I 1 i ERPIP 4.1.10 REVIEW / APPROVAL I REVISION CHANGE REVIEWER SIG/ SUPERVISOR POSRC PLANT SUPERINTENDENT DATE EPU SIG/DATE MTG /DATE 0 l M & "OA3 $ld$rio.n.f3 83-12b 0 R L,j) Wlub3 1 i 9 I f
- 7. -
i l i l i i l l e e 4
ERPIP 4.1".10 Rev. 8, Ch. I UST OF EFFEC 11VE PAGES PAGE NUMBER REVISION 4.1.10-I 8, Ch.1 '4.1.10-2 6 6 i l
ERPIP 4.1.12 Rev.9,Ch.1 TITLE: FIRST AID TEAM LEADER CHECKLIST 1.0 RESPONSIBLE INDIVIDUAL The First Aid Team Leader (FATL) is responsible to the Radiation Protection Director (RPD) or, in the absence of the RPD, the Site Emergency Coordinator (SEC) { for directing the First Aid Team members in evaluating personnel accidents, performance of first aid procedures, triage of injured / Irradiated personnel, recommending subsequent actions to the RPD or, in the absence of the RPD, SEC, and transportation of injured personnel as directed by the SEC. In the absence of a FATL, a First Aid Team member will carry out the job functicas of the FATL. The SEC may require the FATL to make notification calls referenced in this procedure. 2.0 CONDITIONS AND PREREQUISITES 2.1 A PERSONNEL IN3URY has been anncunced. Ch.1 2.2 Actions listed in ERPIP 3.1 are to be performed as required by prevailing conditions or by the RPD. 3.0 ACTIONS AND LIMITATIONS (In Operational Support Center or at scene o'f accidents, as appropriate) - NOTE - Checklists are to be used as determined by the FATL. Spaces for initials and times are to be utilized, as necessary, to clarify the status. 3.1 Onsite Actions 3.1.1 Ensure that team members are notified in accordance with ERPIP 3.1. Ch,1 Members Properly Notified: / Initials Time 3.1.2 Assemble First Aid Team members in designated Assembly Area. Report accountability and availability of team to the RPD. Reported: / TriItiT Time l - l. l i y
~ E?. PIP 4.1.12 Rev.9 3.1.3 If injury occurred in very high radiation level area, or if potential exists, brief First Aid Team members en emergency exposure criteria per ERPIP 4.G.I. Briefed: / Initials Tune 3.1.4 Direct First Aid Team member (s) to scene of accident to perform necessary actions per ERPIP 4.6.2. First Aid Team Directed: / Initials Time - NOTE - F/A bag, dose rate meter, stretcher, blankets, and other necessary equipment should be obtained by team member enroute to scene. If team member responding is unable to obtain necessary equipment, it should be transpor:ed to the scene as soon as possible. 3.1.5 Ensure each Team member is equipped with proper protective clothing and equipment as appropriate. First Aid Team Properly Equipped: / s Ininals Time ) - CAUTION - DONNING OF PROTECTIVE CLOTHING AND EQUIPMENT SHOULD NOT INTERF5RE WITH IMMEDIATE LIFESAVING FIRST AID. EFFORTS BY FIRST REPORTING TEAM MEMBERS. PROPERLY EQUIPPED TEAM MEMBERS WHEN AVAILABLE SHOULD RELIEVE FIRST REPORTING TEAM MEMBERS AS SOON AS POSSIBLE. 3.1.6 Increase the number of (qualified) participating First Aid personnel as necessary to control the accident. 3.1.7 Have a rapid assessment of the radiological hazards in the area performed and determine the need to remove injured to a lower exposure rate area. NOTE - If an injury is severe, immediate lifesaving F/A is the highest priority and radlological conditions are considered secondary unless acute radiation hazard for casualty far exceeds injury hazard and if rescue 2-m
ERPIP 4.1.12 Rev. 9, Ch. I personnel would exceed preplanned emergency exposure levels for lifesaving purposes (e.g.,1200 R/h for aid results in a stay time of 3 1 minutes). Radiological status: Exposure rates R/h Contamination present (circle one): Yes No 3.1.3 Ensure communications have been established and constantly maintained (If possible) between the scene of the accident and the i RPD. Evaluate the nature and extent of injuries, report to the RPD by page and record the following: (1) Injury Data Name Type & Extent of Injuries Reported by/ Time 1. 2. 3* ( 4. 3. (2) OSC notifled: / Initials Time (3) Record request of assistance or supplies: I i l 3.1.9 Determine need for medical or emergency transportation. Ch.1 Medical Assistance Required (circle one): - Yes No Emergency transportation Required (circle one): Yes No i l If use of a helicopter is necessary, call 911 and request the Medevac helicopter. I ERPIP 4.1.12 Rev. 9, Ch.1 3.1.10 Ensure that injured personnel who are contaminated have loose contamination removed without aggravating injuries. Completed: / Initiajs Time - NOTE - Except for severe injuries requiring Immcdiate medical treatment, injt. red personne1 should be transported to the Controued Area Medical Treatment Room (or Farm Demo Building, if necessary) for definitive decontamination prior to transport to CMH. 3.1.11 If victim is contaminated and need for hospital assistance is probable, Ch.1 report to OSC or Control Room, make an Alertinst can to the Calvert Memoria1 Hospital, have contracted consulting physician on-call alerted, and provide the following information if available: - NOTE - If the FATL cannot leave the accident scene, contact the Control Room and have the 55, SEC, RPD, or an Emergency Communicator make the Alertinit phone s.all. (1) Number of individuals injured. (2) Whether or not radioactively contaminated (if not, stress to CMH that there is NO ridioactive contamination involved). (3) Extent of injury,11 known. Alerting Can Made to CMH: / Initiais Tune 3.1.12 If Internal contamination exists or is probable, commence collecting Bloassay samples in accordance with standard plant practices. Bloassay sampling required (circle one)4 Yes No Bloassay samples conected (circle one): Yes No 3.1.13 Have the RPD, SS, or SEC arrange for transportation of seriously Ch.1 injured personnel (see ERPIP 3.1 Personne1 Injury). Transportation arranged: / Initials Time 3 e as a a
ERPIP 4.1.12 Rev. 9, Ch.1 3.1.14 Assign a toam member to accompany injured person to Calvert Memorial Hospital (see ERPiP 4.6.2 & 4.5.3). Team member assigned: / Initials Time 3.1.15 Have First Aid Team member or a Health Physics Technician report to hospital Radiation Emergency Area (REA) to perform duties per C ERPIP 4.6.3 to advise as to contamination control and perform radiation safety coverage for the REA. - NOTE - Attending physician at hospital will be in-charge. Instruct team member he is to assist only until relieved by a Piant Health Physicist. 3.1.16 Have Rescue Squad call to Calvert Memorial Hospital while t-ansporting the injured personnel. Provide the following information:- (1) Number of injured being transported to CMH (2) Extent of injuries (3) Whether or not radioactively contaminated (]. (4) Expected time of arrival at CMH (5) Special equipment required by hospital personnel, if so, specify (6) BG&E Medical Departmeni: notified (circle one): Yes No Ch.1 Phone numbers in Appendix A.2. Notification call made: / Initials Time 3.1.17 .H' ave RPD notify Plant Health Physicist. NOTIFICATION CALL MADE: / Initials Time i 3.1.18 Ensure team member assigned to accompany ambulance or other vehicle (1) Has Ambulance kit. (2) Completed EXHIBIT 4.6.2-A, PATIENT RADIATION & MEDICAL STATUS FORM and 4.6.2-B, BODY WOUND & CONTAMINATION FORM.
1 1 ERPIP 4.1.12 Rev.9 (3) Directs dr;ver to: Emergency Recm Radation Emergency Area e 4 .e n e e e 9 e 6- ___m__._-_-
ERP!p 4.1.12 E.T:W/ APPROVAL 1 C LREVISION CHANGE REVIEWE~s SIG/ SUPERVISOR POSRC PLANT SUPERINTENDENT OATEY;., EPU SIG/DATE MTG /DATE G.f && ***' &g- /-*d5 9 g %-% -QQ Q qk 9' 1 4($l=!0'e% 7@k/de.ina 83-tze ng1L,,,),dijs l s l I l \\.. I I 2 i l y l / i i
~ ERPIP 4.1.12 R,ev. 9, Ch. ~ 1 LIST OF EFFECTIVE PAGES PAGE NUMBER REVISION 1 9,Ch.1 2 9 3 9,Ch.1 4 9,Ch.1 5 9,Ch.L 6 9 I '} ..e e i l 9 l C
ERPIP NO.: 4.1.14 / REY. 6 i DATE: November 16, 1981 ( D TITLE: DOSMETRY TEAM LEADER CHECKUST l.0 R ESPONSBLE INDIVIDUAL Under emergency conditions the Dosimetry Team Leader (DTL) is responsible to assure that existing procedsres, RCP 3-300 through 3-310, are appropriately implernented. Complete exposure records of persons within the protected area shall be kept by the Dosimetry Team Leader in accordance with 10CFR20. 2.0 CONDITIONS AND PREREQUISTES 2.1 As directed by the RPD. 2.2 On occurrence of a Radiological Event. 3.0 ACTIONS AND UMITATIONS Gn the Rad Chem area or ECC) 3.1 During an Alert, Ste Emergency or Ceneral Emergency have DT members report to the Operational Support Center (or as designated by the DTL) and ( implement ERPIP 4.5.1. .s . MF -NOTE-Checklists are to be used as determined by the DTL. Spaces fx initials and times are to be utilized, as necessary, to clarify the status. 3.2 Periodically establish communication with the ECC, TSC, Control Room and l ERT Leaders or Members to assure all personnel involved in emergency actions are equipped with_necessary SRDs and TLD badges in areas of high radia' tion and are monitored at appropriate intervals. i ECC, TSC, CONTROL ROOM AND ERT LEADERS / CONTACTED: 'nitials Tirne s 4.1.14-1
ERPIP 4.1.'14 Rev.8,Ch.I 3.3 Ensure an ample supply of the following equipment is operable and readily available when requested for emergency use: 3.3.1 Midwange self-reading dosimeters (0-5R) 3.3.2 TLDs EQUIPMENT AVAILABLE: / Initials Time 3.4 Record and maintain the emergency Dosimetry Issue Logs, App. B.3. Consider Ch.1 assigning Dosimetry Team members to plant (Traffic Control) Access Control Points for Dosimetry issue, recovery and documentation operations. 3.5 Accumulated doses of persons within the radiologically controlled areas are to be recorded as per RCP 3-300 series. ALL DOSES RECORDED: / initials Time J l l ln 4.1.14-2
P 1 ERP!P 4.1.14 REVIEf/ APPROVAL I REVISION CHANGE REVIEWER SIG/ SUPERVISOR POSRC PLANT SUPERINTENDENT DATE EPU SIG/DATE MTG /DATE 0 O W '*000 h$i$,o.a.h 63-126 QQboni} lchll95 a a. ] N e e I .I l + 1' t l L
ERPIP 4.1.14
- Rev. 8, Ch. t UST OF EFFECTIVE PAGES PAGE NUMBER REVISION 4.1.14-1 6
- 4. t. a s 2 3, Ch.1 s
== m- "RPIP 4.1.15 .iev. 8, Ch.1 TITLE: RADIOLOGICAL ASSESSMENT DIRECTOR CHECKLIST 1.0 RESPONSIBLE INDIVIDUAL The Radiological Assessment Director (RAD) is responsible to the Site Emergency Coordinator (SEC) for: C 1.1 Assessing, mapping and coordinating the calculations of all radiological data to accurately depict offsite radiation dose projections. 1.2 Monitoring the Plume and Ingestion Exposure Pathways to determine the appropriate protective act'ons to be implemented for the protection of the Population-at-Risk. 1.3.Determinir.g appropriate downwind locations for exposure rate and air sample surveys of the projected plume. 1.4 Dispatching the Offsite Monitoring Teams to selected downwind locations. 1.5 Assuring air sampling survey effectiveness. 1.6 Reassigning the Offsite Monitoring Teams, as necessary. 1.7 Coordinating Environmenta1 Monitoring efforts with Emergency Services Coordinator (ESC). (' 1.3 Assessing the need for ar.d the D'istribution of Radioactive Drugs (ERPIP 4.5.4) 2.0 CONDITIONS AND PREREQUISITE 3, t 2.1 Declaration of an Alert, Site Emergency or a General Emergency. 2.2 Suspicion or recognition of an uncontrolled release of radi'oactive material (A Ch.1 Radiological Event). 2.3 As directed by the SEC. 3.0 ACTIONS AND LIMITATIONS Gn Emergency Contro1 Center) -NOTE-Checklists are to be used as determined by the RAD. Spaces for initials and times are to be utilized for initial actions as necessary to help clarify the status. Appropriate repetitive actions and information is to be recorded on EMERGENCY ACTIONS FORM, (App. B.3). Ch.1 3.1 Announce to the other emergency workers your name and that you are the RAD. Announced: / Initials Time t 4.1.15-1 I ________.___.____________________________b
ERPIP 4.1.13 Rev. 8, Ch.1 if ~ I i 3.2 Receive briefing from SEC on existing plant or site conditions, record the l Emergency Action Level classification below (11 classified). Briefing Received: / EAL Classification: Initials Time 3.3 Implement appropriate sections of ERPIP 3.1, Radiologica1 Event, and/or ERPIP Ch. r1 4.4, Assessment Actions, as necessary. ERPIP 3.1 or ERPIP 4.4 Initiated: (circle one) / Initials Time l 3.4 Obtain wind direction data from the Control Room strip chart and estimate wind direction ud average band width as recorded over the last 15 to 60 minutes. l Average Band Width (In degrees): %d Direction From: Wind Data Recorded: / Initials Time 3.5 Obtain from RPD the following plant or onsite dose rate and air sampling survey results to estimate radiciodine released from plant for offsite dose pmjections. l Location Time of Dose Rate Charcoal Ag Z,eolite Particulate l Area Sample (h) (R/h) Air Sample Air Sample Air Sample 3 3 3 l (uC1/cm ) (uC1/cm ) (uC1/cm ) l l ^ 1 4.1.15-2 ,r
~' ERPIP 4.1.19 Rev.3,Ch.1 3.6 When conditions dictate ensure that Offsite Monitoring Team (OFMT) l members have been activated and assembled in the Assembly Area (Operationa1 Support Center, if Site or Genera 1 Emergency). Offsite Monitoring Team Members Assembled: / e Initials Time -NOTE-1. For a Radiological Event involving airborne releases the Offsite Monitoring Teams must be activated. The Off::ite Menit: ring Team wi11 receive the highest oriority of the ERTs for activation, manning and being dispatched. 2 For a Radiological event actually or potentially involving a release to the environment, RAD is to notify the Environmenta15ervices Coordinator (ESC)(See Appendix A.2 for phone number). Ch.1 ESC Notifled / Initials Time 3.7 Brief OFMT members on the following (as appropriate): ( -NOTE-Briefing may be performed by RPD. Anti C4 Respiratory Requirements Areas to Check Plant Conditions Expected Exposure Rates Planned Stay Time / Total Dose Precautions Emergency Personnel Radiation E' xposures (ERPIP 4.6.1) i Proper Desimetry I Procedures to be Used:, lI Other (Specific Information list here ) 1 11 I i i I l Offsite Team Members Briefed: / initials Time -NOTE-l i Ensure each team member is equipped with the appropriate I equipment. 4.1.15-3
ERPIP 4.1.15 Rev.8,Ch.I l s 3.3 If the nature of gaseous release Indicates the potential for significant levels of Iodine (greater than 40 MPC-h of exposure), consider Immediate administration of radioprotective drugs to all OFMT members prior to field dspatching in accordance with ERPIP 4.5.4.1,11 adequate respiratory 5 protection devices are not available. 3.9 Initiate ERPIP 4.3.1 and dispatch at least one OFMT to survey affected EPI j sectors and zones in accordance with ERPIP 4.3.1. ERPIP 4.3.1 Initiated and OFMT Dispatched: / Initials Time -NOTE-Document an OFMT data received on EXhEIT 4.1.15-A, RAD O.-r su r-MONITORING FORM. 3.10 When release is directed over the Bay towards Dorchester County (within the 10 mile EPI), request the SEC to provide helicopter assistance from the BG&E dispatcher (use the radlotelephone, frequency 153.605 mhz, and Call 51gn KVD 793). -NOTE-i. If company helicopter Is unavailable request a helicopter by contacting the Calvert County Emergency Communication Control Center (See Appendx A.2 for Phone No.). Ch.1 3.10.1 Mave thehelicopter directed to land at a preselegted appropriate landng point at or near "the site and at a specified time to pick up OFMT members for aerial monitoring. i Locatiom Estimated Time of Arrival (ETAh He!Icopter Landing Location and ETA 5pecified: / Initials Time - -NOTE-The helicopter should report to hellpad near Visitor's Center if radation levels permit. The helicopter may be considered for monitoring radological releases from the plant when ground vehicles are unable to accomplish the task. Helicopters should be used minimally for near ground surveys (because of reduced accuracy) ~ f unless accessibility by other vehicles is restricted. Minimum l 4.1.15, H l
~ ERP!P NO.: 4.1 15 / REV. 5 DATE: November 11, 1981 elevation should be 100 f eet above ground level. See ERPIP 4.2.1 for communication to and from helicopter. 3.10.2 Determine location of required ofIsite aerial surveys. Locations: Locations Determined: / Initials Time -NCTE-Describe locations to be surveyed in terms of elevation (in feet) above ground level ard specific distance from the site (in miles). 3.10.3 Brief an additiona10ffsite Monitoring Team (OFMT) of the helicopter landing location, the time, and on present plume conditior.s. Additional Survey Team Briefed: / Initials Time 3.10.4-Direct the OFMT to obtain an Emergency Monitoring Kit (Mobile), {, rkdio suitable for use from helicopter (special radio), and.to meet the helicopter, establish radio contact with the ECC and initiate survey. 3.10.5 Brief team on required survey locations. Helicopter Survey Team Briefed and Dispatched: I Initials Time -NOTE-Required surveys should be (as a minimum):
- 1) Cross-plume measurement to establish plume centerline and plume width.
- 2) Dorchester County (Westem populated section within the 10 mile EPZ).
l
- 3) Perform ERP!P 4.4.1 Procedure 3.4 every 15 mir.utes when plant l
main vent monitor is off scale or inoperable and release is directed through main vent. i
- 4) Specific points defined by RAD.-
3.11 Log all data received from all OFMTs on EXHIBIT 4.1.15-A, R AD OFFSITE MONITORING FORM, and keep SEC posted on specific dose rates. Indicate additional SEC Notifications on EXHIBIT 4.1.15-A. ~ 4.1.13-5 i
ERP_IP 4.1.15 Rev. 8, Ch.1 m I -NOTE-Plot field measurement data and projected doses, as calculated, for determination of the projected versus actual dose correlation and for revision of projections. 3.12 Determine the offsite projected exposure durations by obtainmg expected radiological release times from the Control Room for continuous radiation j release and notify *he SEC. Daza Recorded on EMERGENCY ACTIONS FORM, (App. B.3) and the SEC Ch.1 Notifled: / Imr.aAs Time 3.13 Have Environmental Services Coordinator (ESC) provide confirmatory offsite data (e.g. Environmental TLDs, etc.) to the RAD at intervals determined by projected dose rate estimates and offsite exposure duration estimates which exceed 100 mrem dose. Record an data on EMERGENCY ACTIONS FORM. Ch.1 ESC Contacted: / Initials Time -NOTE-1. The Environmental TLDs should be replaced by the ESC and processed ) at four hour Intervals, when necessary (see ERPIP 4.3.2), and the confirmatory ooses provided to the RAD. T1.D data should be required from specific Sectors / Zones within the plume exposure pathway as a priority over other areas. 2. If Radiologically advisable and with the cooperation of ESC, Instruct CFMTL to have his members collect and replace Environmental TLD's ( at designated Environmental Radiation Monitoring Sample Points. - (See Exhibits 4.1.25 - C and D)." Collec ed TLD's are to be delivered to CETS Mobile Unit for processing. 3.14 When directed by the SEC, communicate directly with the Calvert County EOC and report projected offsite dose Information to therr (Follow-Up Commtmications). i -NOTE - After EOC has notifled the plant that Division of Radiation Control (DRC) has been activated, follow-up communications will be provided t 4.1.15-6 I i
ERPIP 4.1.15 Rev. 8, Ch. I to the 10 mi EPZ Counties, MEMCDA EOC and DRC. Ch.1 Dose Information Reported To Calvert EOC and Communication Recorded on EMERGENCY ACTIONS FORM, (App. B.3) Ch.1 / Initials Time -NOTE-Obtain confirmatory dose and exposure rate data throughout su3cient areas in the plume'secter/:enes o re-evaluate plume characteristics and actual doses received in area. Include SRDs, TLDs, field surveys, trends, etc. Document data on EMERGENCY Ch.1 ACTIONS FORM, and EXHIBIT E1.15-A, as appropriate. 3.15 Implement ERPIP Appendix C.1, C.2, and C.3, assessment goals for Immediate Response, as necessary to obtain: a more accurate assessment of severity; of the quantitles, balances and major release pathways associated with various plant conditions; of dispersion of fission products in the environment; and on dose projection including the back-calculation of the fission product source based on fleid measured exposure rates or air concentrations. .-(~
- ERPIP Appendix C.1, C.2, and C.3 Implemented (circle as appropriate):
/ Initials Time 3.16 Advise the SEC on the habitability of the ECC (or Alt ECC) and actions to be taken with non-CCNPP personnel working on the area. Should the. area be 0.5 mR/hr actual or projected, Individuals without personnel dosimetry should be dismissed, asked to return to normal off-site work locations, or, If habitable, move to the "other" emergency control center. 3.17 Advise the SEC on recommended protective actions to the population-at-risk (ERPIP 4.4.8 and 4.5.6). Protective Action: None Recommended i Recommended d Location (Sector / Zone): Action: l 1 4 i / Initials Time c 'i J 4.1.15-7 .J
l ERPIP NO.: 4.1.15 / REV.2 DATE: September 1,1981 s EXHIBIT 4.1.15-A RAD OFFSITE MONITORING FORM C Date: Name: INITIALS / TIME TEAM LEADER /NO. LOCATION EXPOSURE SEC NOTIFIED ( ) RATE ( (Shielded) l l l l l ( i l l I i l 1 l 4.1.15-3
A ERP!P 4.1.15 REVIEW /ArPROVAL j hEVISION CHANGE REVIEWER SIG/ SUPERVISOR POSRC PLANT SUPERINTENDENT DAT* EPU SIC /DATE MTG /DATE A hl-_!0'8*85 hh,4. g.<h $3-12$ '3RQ Jjjo) & I 0 } ) a / / 4 4 4 4 e r e. ,. _ -.. ~ -, ,w-
~ l ERPIP 4.1.15 R.ev. 8, Ch.1 UST OF EFFECRVE PAGES PAGE NUMBER REVISION - 4.1.15-1 8, Ch.1 C 4.1.15-2 8, Ch.1 4.1.15 8,Ch.1 4.1.15-4 3,Ch.1 4.1.15-5 5 4.1.15-6 8, Ch.1 l 4.1.15-7 s, ch.1 l 4.1. u-, 2 i 7 t e e e i i i i m me-}}