ML20082C118

From kanterella
Jump to navigation Jump to search
Forwards Annual Summary of Changes,Tests & Experiments Performed at Aerotest Radiography & Research Reactor for Period Ending 910630. Continuing Problem Exists Re Spurious Scrams Due to Electronics Problems
ML20082C118
Person / Time
Site: Aerotest
Issue date: 07/09/1991
From: Simens H
AEROTEST OPERATIONS, INC.
To: Scarano R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
Shared Package
ML20082C123 List:
References
NUDOCS 9107180040
Download: ML20082C118 (1)


Text

_ __ _________ _ - _-__

$[+

AEROTEST OPERATIONS, INC.

3455 FOSTORIA WAY. SAN RAMON, CAUFORNIA 94583. (415) 866-1212 DES U.S. Nuclear Regulatory Commission, Region V 9 July 1991 Division of Radiation Safety and Safeguards 1450 Maria hane, Suite 210 Walnut Creek, CA 94590 Attention:

Mr Ross Scarano, Director

Subject:

Annual Summary of Changes, Tests and Experiments at Aerotest Radiography and Research Reactor (ARRR),

Docket No.

50-228, for period during 6/30/91 Dear Mr.

Scarano:

The enclosed report summarises the ARRR operations from July 1, 1990 through June 30, 1991.

This submittal complies with the requirements set forth in 10 CFR, part 50.59,

" Authorization of Changes, Tests and Experiments." Summary forms of monthly operations and unscheduled power reductions are included.

As shown in~the Summary Table of unscheduled shutdowns, there continues to be occasional spurious scrams due to electronics problems.

The root cause of these is primarily related to the fact that all of the electronics are aged non-solid state units.

Also electric power failure, including one occurrence of high water temperature caused by a loss of power to the cooling tower, mada up the bulk of remaining unplanned scrams.

All fuel elements were removed and inspected during the yerr.

One graphite element was removed from service to make room for the addition of a new fuel element.

No new or unusual problems have been noted during the year and reactor operations have remained stable with respect to safety and reliability.

Very truly yours, AEROTEST OPERATIONS, INC.

/

L L

y u

(

9107180040 910709 Hugo U( himens PDR ADOCK 05000228 Reactor Supervisor R

pga Enclosure cc:

Director of Inspection & Enforcement i

U.S.

Nuclear Regulatory Commission Washington, D.C.

20555 2.00021 g t[ 7

,t.

l I

SUBSIDI ARY oF

/ /#