NUREG-0837 Vol. 3, No.1 1
- NRC TLD Direct Radiation Monitoring Network Progress Report January-March 1983 i
i U.S. Nuclear Regulatory Commission i
NRC Region I F. Costello, T. Thompson, L. Cohen, M. Taylor ga REcoq l
l' l
5 -l
\\,..,
/
.+
i
\\
831108o471 831031 oe$7R PDR
NOTICE Availability of Reference Materials Cited in NRC Publications Most documents cited in NRC publications will be available from one of the following sources:
- 1. The NRC Public Document Room,1717 H Street, N.W.
Washington, DC 20555
- 2. The NRC/GPO Sales Program, U.S. Nuclear Regulatory Commission, Washington, DC 20555
- 3. The National Technical Information Service, Springfield, VA 22161 Although the listing that follows represents the majority of documents cited in NRC publications, it is not intended to be exhaustive.
Referenced documents available for inspection and copying for a fee from the NRC Public Docu-ment Room include NRC correspondence and internal NRC memoranda; NRC Office of Inspection and Enforcement bulletins, circulars, information notices, inspection and investigation notices; Licensee Event Reports; vendor reports and correspondence; Commission papers; and applicant and licensee documents and correspondence.
The following documents in the NUREG series are available for purchase from the NRC/GPO Sales Program; formal NRC staff and contractor reports, NRC-sponsored conference proceedings, and NRC booklets and brochures. Also available are Regulatory Guides, NRC regulations in the Code of Federal Regulations, and Nuclear Regulatory Commission Issuances.
Documents available from the National Tech :ical Information Service include NUREG series reports and technical reports prepared by other federal agencies and reports prepared by the Atomic Energy Commission, forerunner agency to the Nuclear Regulatory Commission.
Documents available from public and special technical libraries include all open literature items, such as books, journal and periodical articles, and transactions. Federal Register notices, federal and state legislation, and congressional reports can usually be obtained from these libraries.
Documents such as theses, dissertations, foreign reports and translations, and non-NRC conference proceedings are available for purchase from the organization sponsoring the publication cited.-
Single copies of NRC draft reports are available free upo'i written request to the Division of Tech-nical Information and Document Control, U.S. Nuclear Regulatory Commission, Washington, DC 20555.
Copies of industry codes and standards used in a substantive manner in the NRC regulatory process are maintained at the NRC Library. 7920 Norfolk Avenue, Bethesda, Maryland, and are available there for reference use by the public. Codes and standards are usually copyrighted and may be purchased from the originating organization or, if they are American National Standards, from the American National Standards Institute,1430 Broadway, New York, NY 10018.
GPO Printert copy pnce:..$5.50
NUREG-0837 Vol. 3, No.1 NRC TLD Direct Radiation Monitoring Network Progress Report January-March 1983 Manuscript Completed: October 1983 Date Published: October 1983 F. Costello, T. Thompson, L. Cohen, M. Taylor Region i U.S. Nuclear Regulatory Commission King of Prussia, PA 19406 f
~o,,,
e l
s. :../
l l
i o
Preface The U. S. Nuclear Regulatory Commission (NRC) Direct Radiation Monitoring Network is operated by the NRC in cooperation with participating states to provide continuous measurement of the ambient radiation levels around licensed NRC facilities, primarily power reactors. Ambient radiation levels result from naturally occurring radionuclides present in the soil, cosmic radiation con-stantly bombarding the earth from outer space, and the contribution. if any, from the monitored facilities and other man-made sources.
The Network is intended to measure radiation levels during routine facility operations and to establish background radiation levels used to assess the radiological impact of an unusual condition, such as an accident.
This report presents the radiation levels measured around all facilities in the Network for the first quarter of 1983.
A complete listing of the site facilities monitored is included.
In some instances, two power reactor facilities are monitored by the same set of dosimeters (e.g., Kewaunee and Point Beach).
All radiation measurements are made using small, passive detectors called thernoluminescent dositeters (TLDs), which provide a quantitative measurement of the radiation levels in the area in which they are placed.
Each site is monitored by arranging approximately 40 to 50 TLD stations in two concentric rings extending to about five miles from the facility. All TLD stations are outside the sita boundary of the facility.
A complete description of the program can be found in NUREG-0837, Volume 2, Number 4.
The National Bureau of Standards (NES) has been performing an independent study of the following characteristics of tne NRC dosimetry system:
energy response, angular depen-dence, temperature and humidity sensitivity, fading, light dependence, self-irradiation, and reproducibility.
NBS has also tested the response of the NRC's dosimetry system against the requirements of ANSI N545-1975 and NRC Regulatory Guide 4.13.
Details of this testing can be found in NUREG/CR-2560 and TJPEG/CR-3120.
The radiation levels are presented as gross and net exposures. The gross exp;sure includes naturally occurring background radiation, radiation levels resulting from a facility's operation, and the exposure received during trans-port and storage of the TLD.
Net exposures are obtained by subtracting an estimate of the exposure received by the dosimeter during transit from the gross exposures.
All exposures are normalized to a 90-day quarter (standard quarter) and reported in units of milliroentgens (mR).
Station numbers for which no data are reported included stations which have been deleted, stations for which the TLD was lost during the quarter, or stations for which the TLD was damaged.
When control dosimeter data are unavailable, no net exposures are calculated.
l Three sets of data are presented for each site.
The first set includes the TLD i
station number, its direction and distance from the site, the integrated gross exposure for the period, and the net exposure normalized to a 90-day quarter (standard quarter).
All measurements are listed with their respective random and total uncertainties.
l l
- ~,
The uncertainties are listed in the following format:
X S ;U x x where X = value of the result 5, = random uncertainty expressed as one standard deviation U = combined total uncerta nty The second set of data summarizes the average net exposure measured in each of the 16 standard windrose sectors around the facility, normalized to a standard
(
quarter. The third set of data summarizes the average net exposure measured at three ranges of distances from the facility, normalized to a standard quarter.
When average net exposures cannot be reported because of the unavailability of the site's control dosimeters, the average gross exposures, normalized to a standard quarter, are reported in these two sets of data. The "std. dev."
refers to the standard deviation of the measurements made in each sector and range, respectively.
This repcrt is one of a continuing series of technical reports covering the results and experiences of the operation of the NRC TLD Direct Radiation Monitoring Network, t
i i
FACILITIES MONITORED DURING FIRST QUARTER, 1983 4
I 1.
Arkansas Nuclear One 33.
Millstone 2.
Beaver Valley 34.
Monticello j
3.
Big Rock Point 35.
North Anna 4.
Browns Ferry 36.
Oconee 5.
Brunswick 37.
Oyster Creek 6.
Byron 38.
Palisades 7.
Calloway 39.
Palc Verde 8.
Calvert Cliffs 40.
Peamh Bottom 9.
Clinton 41.
Perry 10.
D. C. Cook 42.
Pilgrim 11.
Cooper 43.
Prairie Island 12.
Crystal River 44.
Quad Cities 13.
Davis-Besse 45.
Rancho Seco 14.
Diablo Canyon 46.
Robinson 15.
Dresden 47.
St. Lucie 16.
Duane Arnold 48.
Salem / Hope Creek 17.
Farley 49.
San Onofre 18.
Fermi 50.
Seabrook 19.
FitzPatrick/Nine Miie Point 51.
Sequoyah 20.
Fort Calhoun 52.
Shoreham 21.
Fort St. Vrain 53.
Summer 22.
Ginna 54.
Surry 23.
Grand Gulf 55.
Susquehanna 24.
Haddam Neck 56.
Three Mile Island 25.
Hatch 57.
Trojan 26.
Indian Point 58.
Turkey, Point 27.
Kewaunee/ Point Beach 59.
Vermont Yankee 28.
Lacrosse 60.
Washington Nuclear 2 29.
LaSalle 61.
Waterford 30.
Limerick 62.
Watts Barr 31.
Maine Yankee 63.
Yankee Rowe 32.
McGuire 64.
Zimmer 65.
Zion 4
l
ARKAll5AS T L v U I w--. i k n v i n i t ut,, s,n..,
g,r.i yh,,
n, 0 g l... h..-
..r.7.
aua ti nu a iuki u 4
WE Frci ; 0010?n R?n 11<
DAYc:
F nP T.r. l ti: ~ n-
.:: * ;-,., - - 414 rIELv i t
ry v m :;
ilPC LOCA'IGN GROSS llET EXF05URE RATE s p e. +s d. n.. t.
c c.:Tatr.i o.11 r i nn. ;. p e.+ : ci
- v p o. q n_ p ; c ~.p ',
u m:-
v i
(
<i.i:
.w :
wa
. i w si:ll.e
[dec.)
tml.)
+- Rdm; Tot.
+- Rdm; Tot.
0,0,1 4
0.4 n.6 +-
.6 ;
3.1 16.9 +-
.6 ;
3.1-e ;
e l o,. c, + -
- 3 e
i.,t v
.s i,t.1 +-
.e c4 c,. t,
-e, L.u_c a s o.
-.. i s,
.c +-
.6,
..2
- 3.. ;-
,s. e.
t-
.0 :
z.,
z.c UU.s 2
004 13 3.3 15.,T t-
.5 l 2.3 12.4 +-
.5 l 2.5 e
- 9.ea 1_9.4 +_
.s e
.s..
1 s., +-
n_a_s.
=. '.:-
~
15.9 t-
.5 l 2.4 12.6 +-
.5 l 2.6 006 37 i c.. 4 +. _
.g.
O.q 19.o. +-
.g.,
_?. o.
4
- a. n. i
- 7. c-
- e 005 60 I.2 18.1 +-
.5 l 2.7 14.6 +-
.6' 2.8
- On9, 92, 0.5 17.9 +-
.5 l
- 2. 7, 14,.4 +-
.6 ;
2,. 8 e ;
c ni. e
- c. :.
1 c.. U_ + -
e.e
, +.-
.es, e
c
.s,
c,. a.
i s.. c.
.s
+
2,.. 4_
13,.0 +-
.ea.;
V i. c 10.2, 6.0 le.9 +-
.es; 2. 3, 10.e0 +-
.6.
- i.. e, U_,11 12_2_
- 2. 1 it. 3. +-
.es;
- z.. <
4 01:
1 :;-;
/.e 14.t +-
.4 l z.z 11.4 +-
.5 ;
2.
m 014 130 4.9 14.8 +
.4 l 2.2 11.7 +-
.5 l 2.4 4;7 u c.::.:Ir oc. Wn.ieg:). T.1n. c:. I nc i c,e.
- n. l 1.
,a
..a t
.cs.,
c.es i.,, +.-
4
- a 10.4 +-
.ea, c.:
i7l
.s.
e, i <
t.c r
018 189 3.2 16.8 +-
.5 l 2.5 13.4 +-
.6 l 2.7 019 205 2.5 15.0 +-
.4 !
2.2 11.8 +-
.5 l 2.5 ac.s_
=.c le.4 +_
.e o.a 1.?. ci + -
.s e
- o.. s.
n_ m.ea 1
n_ oi
_?.; s
- a.. s_.
1.9.,,_
. s-
_?. ?
14_.7 +_
.e
,e
- 9. c_;
e i
- m _%
,m s.
044
-w x.c is.$ +-
.4, 2.0 lb.qc +-
.s ;
- 2. :)s g
+-
.4' 2.2 11.3 +-
.5 ;
2.4 M. 57.P' 023 257 2.5 14..
^ - * -'n n u~ "t"u 'v u c 'utl" T E'M'
~ ~ -
ir: cia u"k vn1 t
4 4..
e,3,.
r1 -
' +. -;
. O"
?.q
{c,.9 +_
. b"
?. Q.-
(1? e 97Q 1 _:
- 1. v. 7 4_
s.
m, s
s i
s.
.[
I~
.6,,
c.,[
t,f.,3
.es,
g-I,. "J dcD cD,
4.4 4
i~
- c.. O 1m0.,,t-
.6 t-
.es,
U_..,
z.? C b_4. +4 t i.. c.
.e
,2. 4 1 S.,0
,,. (.
c ci
< +-
.5.
U. z0 z.1..
- . c.
,t.0 +-
s,
13.6 +-
.6 ;
2.7
., 0 +-
.es; c.3 c.t c.
1r.
m
-r ' t 1.9 030 308 4.9 16.7 +-
.5 l 2.5 13.3 +-
.6 l 2.6 031 345 1.3 17.1 +-
.5 l 2.6 13.7 +-
.6 ;
2.7 032 335 4.2 14.3 +-
.4 l 2.1 11.2 +-
.5-2.4 033 110 0.3 16.7 +-
.5 l 2.5 13.3 +-
.6 ;
2.6 033 112 6.0 16.8 +-
.5,l 2.5 13.4 +-
.6 ;
2.7 tv.n. +-
.i y o.J. o o
e v.o 2
n_4. n.
- 1. 4. -[
o. a.
- 91. pJ +-
4 2
v w
041 106 17, 22.9 +-
.7 l 3.4 19.0 +-
.7 ;
3.4
!>. 4
- 11. 'c +-
.s 04?
o'i n.
- 1. '>.
- 14. 4, +-
043 U
b.2 17.4 +-
.5 ;
2.6 14.0 +-
.6 ;
2.7 545 d
5'. 5 1U.5+-
'.4 l 2.I tf'.!+.
'.$e! 2.4 v 6
,e 1
o; e44 n
a1 ig a +_
i 046 0
8.3 17.2 +-
.5 ;
2.6 13.8 +-
.6 ';
2.7 TRANSIT DOSE =
2.0
+-
.4 ; 1.5
ARKAt1SAS FOR THE PERIOD 821220-830414 TLD DIRECT RADIATION ENVIR0l1 MENTAL MONITORING RZIt1U TH (dag. )
NET AVER. EXPOSURE RATF 4 IN GROUP (mR/Std.Otr.) +-Std.Dav.
348.75-ll.25 (N) 13.7 +- 1.9 6
11.25-33.75 (NNE) 13.0 +
.9 2
33.75-56.25 (NE) 12.5 +
.1 2
56.25-78.75 (ENE) 14.8 +
.2 2
78.75-10l.25 (E) 13.2 +- 1.7 2
10l.25-123.75(ESE) 14.4 +- 2.5 5
123.75-146.25(SE)
Il.5 +
.2 2
145.25-158.75(55E) 18.0 +- 0.0 1
158.75-191.25(5) 12.8 +
.9 2
19L.25-213.75(55H) 12.0 4-
.3 2
213.75-236.25(SW) 12.5 +- 3.2 2
236.25-258.75(WSW) ll.3 +- 0.0 1
258.75-281.25(W) 14.5 +- 1.0 2
28l.25-333.75(WNW) 13.2 +
.8 2
303.75-326.25(NH) 12.9.+-
1.0 3
326.25-348.75(NNN) 12.5 +- 1.8 2
l I
1 1
DISTANCE (mi) FR0t1 THE PEACTOR NET RVER. EXPOSURE PRTE
+ IN GROUP
~
fnR/5td.0tr.) +-5td.Dev.
0-2 14.0 +- 1.3 11
, ]
2-5 12.6 +- 1.3 15 i
r
>5 13.8 +- 2.4 12 UPNIND CONTROL DATA NO DATA NO DATR
+.-
4
w#1y; p.ehl, cu u
.mi TLD DIRECT FADIATION EriVIRONMENTAL t10HITGRItiG
" P R. T iri 9 ? t ? 1 -g 9 0. 4 i. o 1 ' 1 D A."i 0 Po. p TH:
F u.. L. -
.1
.m r.
m FIELD TIME 90 DAYS i
NRC LOCATION GROSS HET EXPOSURE RATE STATION AZI!!UTH'DIii EXPOSURE uR) mR/Std 0tr.
(& c.>
t mi. -
+- Rdm; Tot.
+- Rdm; Tot.
002 6-13 15.4 +-
.5 ;
- 2. 3 N0 t1ET' DATA 004 31 12 14.9 +-
.4 l 2.2 NO NET DATA 005 55 9.4 15.2 +-
.5 l 2.3 NO HET DATA 006 60 9.5 15.0 +-
.5 !
2.3 NO NET DATA
.i
.?...
HQ. t1 1ic' DATA
- n. n. r.
. c-0 1:..? +-
c; 008 110 4.3 20.0 +-
.6 l 3.0 NO NET DATA 009 110 2.2 15.8 +-
.5 l 2.4 NO NET DATA 010 91 2.4 16.3 +-
.5 l 2.4 t10 t1ET DATA 011 77 3.7 19 S +-
.6 l 3.0 ti0 NET DATA 012 153 4.2 21.4 +-
.6 l 3.2 N0 NET DATA 013 170 4.2 18.6 +-
.6 l 2.8 NO NET DATR f
014 190 4.4 15.1 +-
.5 l 2.3 tl0 NET DATA 015 208 3.5 18.4 +-
.6 ;
2.3 110 NET DATA 016 264 5.5 18.7 +-
.6 l 2.9 NO NET DATA
- n. 4 '
_m..
c.-
19.i +-
li
. =; e
?,
un. I1'c 1 rihTA.
-.t m
018 232 2.4 19.1 +-
.6 ;
2.9 N0 tiET DATA 019 267 2.3 20.2 +-
.6 l 3.0 NO tiET DATA 020 294 3.2 13.9 +-
.4 ;
2.1 NO NET DATA 021 286 1.2 19.6 +-
.6 ;
2.9 NO NET DATA 022 220 1.3 18.5 +-
.6' 2.3 NO NET DATA 023 255 2.3 20.6 +-
.6 ;
3.1 NO NET DATA 024 209 2.1 18.6 +-
.6 l 2.3 N0 t1ET DATA 025 186 2.1 20.3 +-
.6 ;
3.0 N0 11ET DATA 026 190 2.2 18.1 +-
.5 l 2.7 tl0 NET DATA 02?
125 2
20.7 +-
.6 l 3.1 NO NET DATA 028 87 1.6 19.4 +-
.6 ;
2.9 NO NET DATA 029 59 1.5 18.7 +-
.6 l 2.8 N0 tiET DATA 030 50 1.2 21.2 +-
.6 l 3.2 t10 NET DATA 031 u0 1 9 90.8 +.
.6 ;
3.1 N0 NET DATA 1
032 325 3.5 19.0 +-
.6~;
2.9 N0 NET DATA 033 341 2.5 19.1 +-
.6 l 2.9 HO NET DATA 034 343 5.2 MISSING OR DM1RGED DOSIMETER 035 9
3.6 18.6 +-
.6-;
2.8 NO NET DATA 036 14 3.3 20.9 +-
.6 3.1 NO NET DATA
.5 ;. 2.6 G37 37 3
17.5 +-
N0 NET DATA 338 22 1.8 19.7 t-
.6 l 3.0 NO HET DATA 039 351 1.6 19.4 4-
.6 t.' 2.9 NO HET DATA l_
040.
/ 344 15.
18.7 e
.6 '. 2.3 ft0 NET DATA NO TRAr1 SIT DOSE CALCULATEMTLD CONTROL 3l11It31NG QR i
041 c _..
4344 15.
14.0 +-
24 2.1 LO NET DATA s
t a
J e*
k
=W l'
,A l. '
.,/'.
7 c.
/
m s
/
F* ~
7
+-
wy
'A
.*I f
n
. Mi '*
n 9
i l
, kW
/
~
.[
. 6
./..
. =
J
EEAVER VALLEY FOR THE PERIOD S21221-830412
.TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZU1UTH (dag.)
AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
)
~
348.75-11.25 (N) 14.2 +- 1.7 3
11.25-33,75 (NNE) 14.7 +- 2.6 3
i 33.75-56.25 (NE) 14.3 +- 2.4 3
j 56.25-78.75 (ENE) 14.2 +- 2.0 3
78.75-101.25 (E) 13.5 +- 1.7 3
10l.25-123.75 (ESE) 14.3 +- 2.4 2
123.75-146.25(SE) 16.5 +- 0.0 1
14 5.25-168. 75 ( 55 E )
17.0 +- 0.0 1
l 160.75-191.25(5) 14.3 +- 1.7 4
19t.25-2L3.75(55H) 14.7 +
.l.
2 1
i 213.75-236.25(SW) 15.0 +
.4 2
i 236.25-258.75(WSW) 16.4 +- 0.0 1
258.75-281.25 ( W )
15.1 +
.B 3
281. 2 5-303. 75 ( WNW )
13.3 +- 3.2 2
4 303.75-326.25(NW) 15.8 +- 1.0 2
326,25-348.75(NNN) 15.2 +- B.O 1
i.
I t
5 P
l DISTANCE (mi) FROM THE PEACTOR AVER. EXPOSURE RATE
+ IN GROUP (niR/5td Qtr.)
+-5t d. De v.
B-2 15.7 +
.B 9
2-5 14.8 +- 1.6 2B i
>5 12.8 +- 1.3 7
t UPHIND CONTROL DRTA 13.B +- 2.7 2
e i
BIG ROCK TLD DIRECT RADIATI0l1 ElWIRONMENTAL MONITORIl1G FOR THE PERIOD 821220-830412 114 DAYS FIELD TIME 86 DAYS tiRC l.0C ATI0ti GROSS IIET EXFOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(ai.)
+- Rdm; Tot.
+- Rdm; Tot.
001 208 4.9 19.1 +-
.6 ;
2.9 16.7 +-'
.8 ;
3.9 002 220 3.6 19.1 +-
.6 l 2.9 16.7 +-
.8 l 3.9 003 204 2.4 20.2 +-
.6 ;
3.0 17.9 +-
.8 ;
4.0 004 176 3.3 18.6 +-
.6 ;
2.8 16.2 +-
.8 l 3.8 005 161 4.6 20.3 +-
.6 l 3.0 18.0 +-
.8 l 4.0 006 133 4.7 19.4 +-
.6 l 2.9 17.1 +-
.8 ;
3.9 007 116 3.7 21.4 +-
.6 l 3.2 19.1 +-
.9~;
4.2 008 111 4.7 20.7 +-
.6 ;
3.1 18.4 +-
.9 l 4.1 009 98 4.5 19.9 +-
.6 l 3.0 17.6 +-
.8 ;
4.0 010 88/
12.
18.4 t-
.6 l 2.3 16.0 +-
.8 ;
3.8 011 83-16.
19.1 +-
.6 ;
2.9 16.7 +-
.8 ;
3.9 012 83/
16.
18.5 +-
.6 ;
2.8 16.1 +-
.8 ;
3.8 013 83/
16.
19.0 +-
.6 l 2.9 16.6 +-
.8 l 3.9 014 77 3.4 19.2 +-
.6 l 2.9 16.8 +-
.8 l 3.9 015 96 1.8 18.8 +-
.6 l 2.8 16.4 +-
.8 l 3.9 016 118 2.0 21.0 +-
.6 ;
3.1 18.7 +-
.9 ;
4.1 017 134 2.0 19.1 +-
.6 ;
2.9 16.7 +-
.8 ;
3.9 018 222 1.9 18.9 +-
.6 l 2.3 16.5 +-
.8 l 3.9 019 194 1.4 21.6 +-
.6 l 3.2 19.3 +-
.9 ;
4.2 020 179 1.5 19.8 +-
.6 l 3.0 17.4 +-
.8 l 4.0 021 153 1.1 18.8 +-
.6 l 2.3 16.4 +-
.8 l 3.9 TRAtlSIT DOSE =
3.1
+-
.5 ; 2.4
~
~
BIG ROCK FOR THE PERIOD 821220-830412 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING 1
RZIt1UTH (deg.)
NET RVER. EXPOSURE RATE
- IN GROUP (mR/Std.Otr.) t-Std.Dav.
348.75-11.25 (N)
NO DRTA+-NO DATR 0
11.25-33.75 (NNE)
NO DRTA+-NO DATR 0
33.75-56.25 (NE)
No DRTA+-NO DATR 0
56.25-78.75 (ENE) 16.B +- B.O 1
78.75-101.25 (E) 16.7 +
.B 3
]
10l.25-123.75(ESE) 18.7 +
.3 3
123.75-146.25(SE) 16.9 +
.3 2
14 5.25-158. 75 ( 55E )
17.2 +- 1.1 2
158.75-191.25(5) 15.B +
.9 2
4 19l.25-2l3.75(55H) 18.0 4-1.3 3
16.E +
.2 2
236.25-258.75(W5W)
NO DRTAt-NO DATR 0
258.75-281.25(W)
NO DATAt-NO DATR 0
28 l.25-303.75 (WNW)
NO DATAt-NO DATR 0
303.75-326.25(NH)
NO DATAt-NO DATR G
326. 25-34 8. 75 ( NfiW )
NO DATA +-NO DATA 0
t i
l DISTANCE (mi) FR0ft THE PEACTOP NET RVER. EXPOSURE RATE
+ IN GROUP (mP/5td.0tr.) +-5td.Dev.
B-2 17.3 +- 1.2 7
2-5 17.4 +
.9 10
>5 12.0 +- 2.0 1
UPNIND CONTROL DATA 16.5 +
.3 3
i i
i 1
?
. = - -.
ER,O,WN5 FERRY Tur J
- -- v.I,n t t i,xn v.,I n'.! i _m uni > i xU hih4 ht i n L n>4ui1I Tux t h1.-
t a.
t i
u e
-r
..3,--
,.,..4 4n 7..io.
rts.IU-, tricc.e coe*31 4uo ant:
r u.x int p
1 F T ELD. 'In*C A G.. U. n "o.
.-. i N,.R C LOC ATI0.il, GROSS NET EX.POSURE RATE
- -v t i n i I u.ih m I p.4 b;Ie aneDiti
..m
!= i i r. u.-. s ! n t ' m x i mn.e 5 t d. u t r.
r e
e-sq.-
tnr ci. 5e n
( di c.. )
(ai.)
+- Rdm: Tot.
un n tu
,.U. liitTE,Rdm; Tot.
+-
r1 ! 5.n. I N - -.. h4. u-v, 001 ice y
4 U-t x
,t b UK i.t i.f _0
}. 0_.
- v.e tO.q +_
.4 J
i. o.>
i i.j. 9
- 4. _
0. 9_
1 003 153 4.3 11.7 +-
.4 l
,1. 9 10.6 +-
.5 l 2.2
-4
.,4, 4 4 4
it. 1..t-
.cJ,
U. 0. _4
- c. i d.
1 t.1 t-c.:
- c.. e J.. o J.
.t 1..9 10.0 +-
.D ;
- 2. :3 12. 9, ++ -
U00 220 5
U.
cc
- +.. =
o4-4 e
e ;
je
.J c..
,.,,t-
.e c.c Ut
.J.c io.c J,
F*
u b4 "i S.1 1.1 14.J +-
.4 c.:
ct *-
4 4 e 4
ja i
n
.c.C t-
.C c.e 4
J J,
J f.iG Q O. C 7 11
,i
?. i.t i
d
- ?.7
+_
- t. i. 7 +-
.ed
?.i d
1v I
.4 1 l vv iv!
.6 n
4 4 7 9
4
{4 {j :.Y 1d "r
j *: 7 -
4
- c
.).c i'
.4 c.j ii. c I"
.C s
{g {j n 7. S 4
e 45
?.
4 i
7:
4 j
Q
.C c.4 J,
7 4
v
+
c2e
".J Y.)
t~
.4 c.1 d,
c.i
.. s
?4di1 c O
- 1. r.7
.t.J t-
.t c. :.
k r.. eJ t-J,
c.J j4 e -
4 i
.i,
a e.
6 e n
4m o 4 :-
4 11.4 4-
.e c.3 i
j-4
.. a g2,1 -
c40 c.
.d.4 +-
.4
.,0 J,
c.
r4 a,e 4
?
4 6 7 4
U 1 v.
ced 1.i iO.i t-
. at
,i c.1
.- a m ;.
,6 j
e 6
4
.1.(
t-
.J c.9 r4 6..:
47 i
4 ei. c.,
+.-
.c, c.1 t5r.c +-
.o, o.j u3n cet it i
015 2,01
-?
16 0 +...5,.a; 2.4 14.0 +-
.6 ;
2.7 m..
c4 -
i t.1 nistuiu un unc.nuta uutIu Tt,.
g r
nt n
eit 017 50
- 3. 5 14.2 +-
.4 ;
2.1 12.2 +-
.5 ;
2.4 018 51 3.5 12.6 +-
.4 l 1.9 10.5 +-
.5 ;
2.2 019 62 3.2 13.9 +-
.4 l 2.1 11.9 +-
.5 ;
2.4
.r.-
e: t-a.,
1e.c t-
. e.
c.2 1o.e +-
.eJ,
etc
.. t e
c.o 1 2
. i 6
0 J c.
nt c' 4i 11i 0'.1 it i 1
.J.4
+-
.r c. O' i
1^.i
.C
. O" d t t g,
J 5 c
i.t ? ?
f<4 1.41 17.G 4.
.J m.
C -
i 9.'.
i c. f.j +. _
.s, m.?
?
v i
v y
t)Q Qi.j
) n'
{ 4. Q.
- 4. _
4 ',
9. ~'
{ ). Q.
- 4. -
~
I d
i_v
)m.Ev m
m
-4 je..
.e c.4 e
m 4
n,
Lr,4 1.j 1
.c c
+-
J 4 13.,.:e +-
.e c.<
4.-
.J.c, t-J,
U.. e 4e c.;
- l.. r.
4 e ;
c.e 11.c t-
.J c.,a cJ o
.4
- 026, 26 1.7 16.4 +-
.5 !
2.5 14.4 +-
.6 l 2.7
- n. e. t 2;
t..
14t.1
+_
4 e
e e
.,.1
- 1. 0 1 +._
.J 9.4t
._v
- ym 1 6. m.
1
- 13. c 4-4 i 4m e
e ;
c.d 11.nc +-
.J c.,
vec OOv
.n 029 0'7 3.5 i1I5 SING OR DRi1 AGED DOSIriETER
~,
- 030,
- 0., u.
4_ -
12.5. +-
.4 ;
1.9 10,. 4. + -
.5_ ;
2.2 4e.6 +-
..3; 2.3 13.6 +-
.b ;
2.t U 'd i
- f t 3.0 J
- n. ;;
a.-
1_9 14..? +_
t-
- 9.,1 to.:
4._
.e 9.9 4
1
.4 J,
m.o" e ;
-.. J leJ.c +~
.J c.)
10,. t.
.e 7- ) )
b, J,
,c.
r, = 4 en 4
u4 de r
- 14.,.-
.4 c.c it.4 t-
.3
,3 c.e 4
J n_ve Qe c
4
,J
- .4
- 14. 1 +_
.t 9
o.4
-.1 10.1 +_
.cJ,-
m 036 68 5.6 18.3 +-
.5 l 2.7 16.3 +-
.6 ;
3.0 03_7 149 7,. 5
- 12. 9. t-
. 4. i.
- 1. 9_
10.9. +-
.5-
- 2. 3 5
. 4 c,
U _10 104
/
10.,9 +-
.3 ;
1.o c.9 +-
.4 ;
2.0 TRANSIT DOSE =
2.1
+-
3 ; 1.1 t
I
BROWris FERRY FOR THE PERIOD 821220-8304!1 TLD DIRECT RADIATI0ti EtF/IR0tii1 ENTAL l10NITORIriG RZIMUTH (dag.)
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-fl.25 (N) 12.0 +- 2.2 2
11.25-33.75 (NNE) 14.4 +- 0.0 1
33.75-56.25 (NE) 11.7 +
.8 4
56.25-78.75 (ENE) 14.4 +- 2.3 3
78.75-10L.25 (E) 12.8 +
.7 3
101.25-123.75(ESE) 13.E +-.3 2
123. 75 - 14 8. 25 ( S E )
10.2 +- 0.0 1
14 5. 25 - 158. 75 ( 55 E )
10.1 4-1.1 3
158.75-191.25(5)
NO DRTR+-NO DRTR 0
19 t. 25-2 l 3.75 ( 55H) 13.5 +
.8 2
213.75-236.25(SH) ll.3 +
.G 2
226.25-258.75(W5u) 12.3 +- 1.3 2
258.75-281.25(W) 12.5 +
.0 2
281.25-303.75(WNU) 11.8 +
.1 2
303.75-328.25(NH) 12.2 +- 0.0 1
326.25-348.75(NNN) 12.3 +- 1.2 3
l l
DISTANCE (mi) FR0t1 THE PEACTOP NET RVER.EXPOSUPE RATE
+ IN GROUP 1
f rtiR/ 5t d. Q t c. ) +-Std.Dev.
0-2 13.0 +- 1.3 9
2-5 12_1 +- 1.3 11 l
25 12.1 +- 1.8 13 I
l UPHIND CONTROL DATA 14.4 +- 3.9 2
l
ERUNSUICiC TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821220-830412 114 DAYS FIELD TIME 92 DAYS NRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.
(dsa.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 260 2.2 14.4 +-
.4 ;
2.2 10.8 + ~
6; 2.9 00?
945 3.4 13.1 +-
.4 ;
2.0 9.5 +-
6l 2.7 003 231 3.8 12.9 +-
.4 ;
1.9 9.4 +-
6l 2.7 004 210 4.9 14.8 +-
.4 ;
2.2 11.2 +-
6; 2.9 005 186 4.3 15.6 +-
.5 l 2.3 12.0 +-
7; 3.0 006 270 4.5 12.9 +-
.4 l 1.9 9.4 +-
6; 2.7 007 272 4.4 13.5 +-
.4 ;
2.0 9.9 +-
6l 2.8 008 73 1.3 16.5 +-
.5 ;
2.5 12.9 +-
7l 3.1 4
009 97 1.0 15.6 +-
.5 l 2.3 12.0 +-
7l 3.0 010 120 1.5 16.7 +-
.5-2.5 13.1 +-
7 3.1 7;
011 131 0.9 16.7 +-
.5 ;
2.5 13.1 +-
3.1 012 156 1.1 18.0 +-
.5 ;
2.7 14.4 +-
7l 3.3 013 180 1.1 15.5 +-
.5 ;
2.3 11.9 +-
6l 3.0 014 194 2.4 15.7 +-
.5 l 2.4 12.1 +-
7l 3.0 015 201 2.0 14.6 +-
.4 l 2.2 11.0 +-
6; 2.9 016 218 1.2 15.3 +-
.5 l 2.3 11.7 +-
6; 3.0 017 252 1.1 17.0 +-
.5 l 2.6 13.4 +-
7; 3.2 018 272 1.2 16.6 +-
.5 l 2.5 13.0 +-
7l 3.1 019 19 1.1 16.3 +-
.5 l 2.4 12.7 +-
7; 3.1 020 2
1.1 15.8 +-
.5 ;
2.4 12.2 +-
7; 3.0 021 288 1.3 15.2 +-
.5 ;
2.3 11.6 +-
6; 3.0 022 307 1.5 15.2 +-
.5 l 2.3 11.6 +-
6; 3.0 023 338 2.
14.7 +-
.4 ;
2.2 11.1 +-
6l 2.9 024 325 4.9 14.2 +-
.4 l 2.1 10.6 +-
6; 2.9 025 338 3.3 15.9 +-
.5 ;
2.4
.12.3 +-
7; 3.1 026 356 5.2 12.8 +-
.4 ;
1.9 9.3 +-
6; 2.7 027 30 6.4 13.7 +-
.4 ;
2.0 10.1 +-
6; 2.8 028 43 9.0 15.3 +-
.5 ;
2.3 11.7 +-
6; 3.0 029 50 8.5 13.7 +-
.4 ;
2.0 10.1 +-
6 -;
2.8 030 59 7.2 15.2 +-
.5 ;
2.3 11.6 +-
6; 3.0 031 65 6.5 15.4 +-
.5 ;
2.3 11.8 +-
6; 3.0 032 74 5.8 15.2 +-
.5 ;
2.3 11.6 +-
6l 3.0 033 88 4.1 14.0 +-
.4 l 2.1 10.4 +-
6; 2.8 034 12/
17.
14.9 +-
.4 l 2.2 11.3 +-
6; 2.9 035 16/
18.
14.0 +-
.4 ;
2.1 10.4 +-
6; 2.8 036 284 15.
16.8 +-
.5 ;
2.5 13.2 +-
7; 3.2 037 284 15.
17.0 +-
.5 ;
2.6 13.4 +--
7; 3.2 038 285 15.
15.5 +-
.5 l 2.3 11.9 +-
6; 3.0 039 287 4.6 13.8 +-
.4 l 2.1 10.2 +-
6l 2.8 040 271 0.7 16.9 +-
.5 ;
2.5 13.2 +-
7; 3.2 TRANSIT DOSE =
3.3 5 ; 2.0 t
+-
l 1
i u-
>m'-4
---Ew7w
---w--v-*-
Nr-e<---
-a=
==
---w-'
w--
-a
FRUtiSWICK FOP THE PERIOD 821220-S30412 TLD DIRECT RADI ATION E!iVIR0riMEtiTAL i10!iITORItiG RZIt1UTH (deg.)
NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-11.25 (Ni 10.7 +- 2.2 2
11.25-33.75 (NNE) 11.1 +- 1.1 4
33.75-56.25 (NE) 10.9 +- 1.1 2
56.25-78.75 (ENE) 12.0 +
.6 4
78.75-10l.25 (E) 11.2 +- 1.1 2
101.25-123.75(ESE) 13.1 +- 0.0 1
123.75-146.25(SE) 13.1 +- 0.0 1
14 5. 25-15 8. 7 5 ( 55 E )
14.4 4-0.0 1
158.75-191.25(5) ll.9 +
.1 2
19t.25-2t3.75(55H) ll.1 +.5 3
213.75-236.25(SW) 10.5 +- 1.7 2
238.25-258.75(H5H)
Il.5 +- 2.7 2
258.75-281.25(H)
It.3 +- 1.8 5
28l.25-303.75fHNH) 10.9 +- 1.0 2
303.75-326.25fNH) 11.1 +
.7 2
326.25-348.75(NNN) ll.7 +
.8 2
OISTANCE(mi) FR0t1 THE PEACTOP NET RVER.EXPOSUPE RATE
+ IN GROUP (mR/5td.0tr.) +-5td.Dev.
0-2 12.4 +
.9 16 j
2-5 10.7 +- 1.1 12
>5 10.9 +
.9 9
UPHIND CONTROL DATA 12.8 +
.8 3
l l
1 i
BRYON TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 830105-830411 97 DAYS FIELD TIME 86 DAYS WRC LOCATION GROSS NET EXPOSURE RATE l
STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.
(dea.)
(ri.)
+- Rdm; Tot.
+- Rdm; Tot.
001 10 1.1 MISSING OR DAMAGED DOSIMETER 000 93 1.0 21.6 +-
.6 ;
3.2 22.0 +-
.8 ;
3.9 003 46 1.6 18.1 +-
.5 l 2.7 18.4 +-
.7 ;
3.4 004 68 1.6 15.0 +-
.4 l 2.2 15.1 +-
.6 l 3.0 005 86 1.4 18.0 +-
.5 l 2.7 18.3 +-
.7 ;
3.4 006 112 1.3 15.5 +-
.5 l 2.3 15.6 +-
.7 l 3.1 007 133 1.4 17.2 +-
.5 l 2.6 17.4 +-
.7 l 3.3 008 175 2.2 17.4 +-
.5 l 2.6 17.6 +-
.7 ;
3.3
.6 l
.6 2.8 009 156 0.6 12.8 +-
.4 l 1.9 12.9 +-
2.9 010 183 0.5 14.0 +-
.4 l 2.1 14.1 +-
011 210 0.6 13.9 +-
.4 l 2.1 14.0 +-
.6 l 2.9 012 236 0.9 14.7 +-
.4 -
2.2 14.8 +-
.6 l 3.0 013 24r U.S 15.1 +-
.5 ;
2.3 15.3 +-
.6 l 3.1
~
014 262 0.7 13.3 +-
.4';
2.0 13.4 +-
.6 ;
2.9 015 298 0.8 14.1 +-
.4 l 2.1 14.2 +-
.6 l 2.9 016 326 1.0 11.2 +-
.3 l 1.7 11.2 +-
.6 l 2.6 017 333 1.6 11.1 +-
.3 ;
1.7 11.0 +-
.6 ;
2.6 018 23 4.0 18.9 +-
.6 l 2.8 19.2 +-
.7 l 3.5 019 17 4.1 12.2 +-
.4 ;
1.8 12.2 +-
.6 l 2.7 020 5
4.3 11.0 +-
.3 ;
1.7 11.0 +-
.6';
2.6 021 340 4.2 14.4 +-
.4 l 2.2 14.5 +-
.6 ;
3.0 022 322 4.9 13.1 +-
.4 l 2.0 13.2 +-
.6 ;
2.8 023 304 6.?
13.7 +-
.4 l 2.1 13.8 +-
.6 l 2.9 024 270 4.8 14.5 +-
.4 ;
2.2 15.0 +-
.6 l 3.0 025 244 4.6 16.0 +-
.5' 2.4 16.2 +-
.7';
3.2 026 224 4.8 13.3 +-
.4 ;
2.0 13.4 +-
.6 ;
2.9 027 213
- 5. 2 13.5 +-
.4 l 2.0 13.5 t-
.6 l 2.9 65 258 1$'
15l1+-
.5 !
2l5 15l2+-
'.$al $l5 en oaa to 7 _.
'4 -
1a t o - +_
4 eo 02n 215 13.
14.2 +-
.4 l 2.1 14.3 +-
.6 ;
3.0 031 204 4.6 10.3 +-
.3 l 1.5 10.2 +-
.5 l 2.5 032 178 4.4 14.0 +-
.4 l 2.1 14.1 +-
.6 l 2.9 033 155 3.9 14.2 +-
.4 ;
2.1 14.3 +-
.6 ;
3.0 034 138 4.6 15.3 +-
.5 l 2.3 15.4 +-
.6 ;
3.1 035 118 4.4 19.1 +-
.6 ;
2.9 19.5 +-
.7 ;
3.6 036 81 3.8 13.9 +-
.4 l 2.1 14.0 +-
.6 ;
2.9 03r (0
5.5 13.6 +-
.4 ;
2.0 13.7 +-
.6 l 2.9 t
i 038 45 4.0 10.5 +-
.3 ;
1.6 10.5 +-
.5 ;
2.5
)
039 40 6.5 14.6 +-
.4 l 2.2 14.7 +-
.6 l 3.0 040 45 15.
13.6 +-
.4l 2.0 13.7 +-
.6 ;
2.9 i
~
I 041 320 3.0 13.8 +-
.4 ;
2.1 13.9 +-
.6 ;
2.9 4 ; 1.9
~
TRANSIT DOSE =
.5 t-i
w-y--
w w,
-e
1
- BRYON FOR THE PERIOD 830105-830411 TLD DIRECT PADIATION ENVIRONMENTAL MONITORING RZ DIUTH (dag.)
NET RVER. EXPOSURE RATE 4 IN GROUP-( mR/St d. Qt 'r. ) t-Std.Dev.
i 348.75-IL.25 (N) ll.D +- D.O 1
i
!!.25-33.75 (NNE) 17.9 +' 5.1 3
j 33,75-56.25 (NE) 14.3 +- 3.3 4
56.25-78.75 (ENE) 14.4 +- 1.0 2
78.75-101.25 (E) 16.1 +- 3.1 2
10l.25-123.75(ESE) 17.5 +- 2.7 2
123.75-146.25(SE) 16.4 +- 1.4 2
145.25-168.75(55E) 13.5 +- 1.0 2
i 160.75-191.25(5) 15.3 +- 2.1 3
19l.25-2l3.75(55N) 12.5 +- 2.0 3
i I
213.75-236.25(SW) 14.1 +- 1.0 2
238.25-258.75(H5W) 15.7 +
.7 2
1 258.75-281.25(W) 14.2 +- 1.1 2
i i
28l.25-303.75(HNW) 14.2 +- B.O 1
303.75-328.25(NN) 13.0 +- 1.3 4
)
I 326.25-348.75(NNN) 12.B +- 2.4 2
I i
i l
DISTANCE (mi) FR0tt THE REACTOP NET RVER. EXPOSURE RATE
+ IN GROUP imR/5td.Qtr.) +-Std.Dev.
B-2 15.2 +- 2.9 15 2-5 14.4 +- 2.7 17
>5 13.9 +
.5 5
i UPilIND CONTROL DRTA 14.1 +- 1.3 3
o
(
l m.
CALLAHAY TLD DIRECT RADIATION ENVIR0tiMEtiTAL EON lTORING FOR THE PERIOD 821222-830419 119 DAYS FIELD TIME 96 DAYS t1RC LOCATI0t1 GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 247 2.1 19.6 +-
.6 ;
2.9 15.3 +-~
.7 ;
3.3 002 95,9,
- 1. 4,
,17. 5. +t -.5 l 2,. 6 1,3.3 +-
.7 ;
3.1
.o.,
o.o o
o.=s 1o.q +_
t3_ U,o tot 1.0 ca.*
v v v 004 304 1.3
,19.1 +-
.6 l 2,. 9 14.8, +-
.7,;
3.3 cu.t- +-
.6, o.1 16.c +
0,. 4 00-se.. u-1.,<
--0 006 1
1.7 20.0 t-
.6 ;
3.0 15.6 +-
.7';
3.4
- n. t_4. 0 2,0.1 +-
.6 l 3.0 15.8 +-
.7 ;
3.4 007
?o
?
9-s
-e c1.ao +_
.o, q. 9_
1o.a, +_
v 00y 3
1.4 20.2 +-
.6 l 3.0 15.8 t-
.7 ;
3.4
.7 3.3 010 98 1.5 19.8 +-
.6 l 3.0 15.4 t-
.7 ;
3.3 011 121 2
19.4 +-
.6 2.9 15.1 +-
.7 ;;
3.3 019 140 2
19.7 +-
.6 l 3.0 15.4 +-
9 a 14.o +_
.v.
o. 9' o
12 0
- n. <19
,co
- =
lav L.s
<L
.D w.
e I
s -
014 183 1.7 21.0 +-
.6 l 3.1 16.6 +-
.7 l 3.5 015 188 1.7 20.3 +-
.6 l 3.0 15.9 +-
.7 ;
3.4 016 202
.7 19.4 +-
.6 l 2.9 15.1 +-
.7 ;
3.3 017 237
.?
18.2 +-
.5 l 2.7 14.0 +-
.7 ;
3.2 018 312 11 19.8 +-
.6 l 3.0 15.4 +-
.7 l 3.3 01; 000 10 20.4 t-
.6 ;
3.1 16.1 +-
.7-3.4 020 268 9
21.3 +-
.6 l 3.2 16.9 +-
.7 ;
3.5 021 247 9
00.0 +-
.6 l 3.0 15.6 +-
.7 ;
3.4 0??
??5 8
19.8 +-
.6 l 3.0 15.5 +-
.7 ;
3.4 02,3 220 P
01.9 +-
.7 l 3.3 17.4 +-
.8 ;
3.6 1._, 4v.4 +_
.ce o. s:
- 14. 1,_
.r.
e, o.9 0;4 e n_ e.
e.a c
v -
s 025 157 4
20,.0, +-
.6 l 3. 0, 15.e +-
.c ;
3.4 o.o
,i 1 o. Q. +-
7,1,
iv s
10.=
t-
.c 4 0 ~4 e
-s-a u &c, c.
2 v a h
o.
O.e J.,1 16,.e t-
.,c.,
U,c 11es 4.-,
- c. l. t
- l.U t-
.c, s
,v c
U,...gt 90 0.0 c
+-
.o ;,
1 <. c, +-
.(
o.c 029 67 3.4 20.5 +-
.6 ;
3.1 16.2 +-
.7 l 3.4 030 48 4.5 19.2 +-
.6 l 2.9 14.9 +-
.7 l 3.3 031 14 6.5 20.8 +-
.6 l 3.1 16.4 +-
.7 !
032 2
5.1 MISSING OR DAMAGED DOSIMETER 3.5 033 335 3.6 MISSING OR DAMAGED DOSIMETER 034 288 4.3 20.8 +-
.6 ;
3.1 16.4 +-
.7,
,3. 5 1c.6 +-
.c,
o.4 1...1 3t-
.e, o. u-04o 3 i u-o..z 0
v
- 036, 264, 3.2 19.4 +-
.6 l 2.9 15.1 +-
.7,;
3.3 v
e ps u, o, e,v e
.. e.
ni.o +_
.o.,
o.o
- i. o,. o, + _
. v, o.5 3
.0 c
=
v a.
,s e
a c.e.i ic.o +-
.o, o. iJ uav cru 1:.
le.o t-
.es,
n.
039 270 15 16.9 +-
.5 l 2.5 12.7 +-
.6 l 3.0 040 203 20 23.c +-
.cl 3.6 19.2 +-
.8 l 3.8 Te Hrie r.i uu.d;. _
, o.
.e c. t.,
-c
+_
r.
a,
CALLA!!AY FOR THE FERIOD 821221-830419 TLD DIFECT RADIATI0t; EtiVIRONMEr4TAL N0ri!TORItiG RZIP1UTH (dag. )
NET AVER. EXPOSURE PATE 4 IN GROUP
( mP./St d. Ot e. ) t-Std.Dev.
348.75-11.25 (N) 15.8 +- 0.0 1
11.25-33.75 t r4NE )
16.1 +-.4 2
33,75-56.25 (NE) 14.9 +- 0.0 1
56.25-78.75 (ENE) 16.5 +-.5 2
78.75-101.25 (E) 16.2 +
.9 3
101.25-123.75(ESE) 15.8 +- 1.0 2
12 3. 75-14 6. 25 ( S E )
14.7 +- 1.0 2
14 5. 25 - 158. 7 5 ( 55 E l 15.3 +-.5 2
158.75-191.25(5) 15.2 4-
.5 2
19l.25-219.75(55H/
14.5 +
.7 2
213.75-236.25(SW) 16.5 +- 1.4 2
236.25-258.75(W5H) 15.5 +- 1.2 4
258.75-281.25tu) 15.1- +- 1. 8 3
I 28l.25-303.75fkNH) 17.1 +- 1.5 3
303.75-326.25(NH) 15.3 +
.4 3
326.25-348.75(NNH) 16.2 +- 0.0 1
DISTANCE (mt) FR0f1 THE PEACTOP NET RVEP. EXPOSURE RATE
+ IN GROUP
( n.R/5t d. 0 t r. ) +-Std.Dev.
D-2 15.5 +- 1.3 14 2-5 15.8 +- 1.0 12
>5 15.9 +
.9 9
UPNIND CONTROL DATA 14.8 +- 3.7 3
CALVERT CLIFFS TLD DIRECT RADIATION ENVIR0!1 MENTAL f10NITORING FOR THE PERIOD 830105-830401 87 DAYS FIELD TIME 84 DAYS NRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.
(dec.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 275 1.5 10.7 +-
.3 ;
1.6 NO NET' DATA 003 284 1.7 10.4 +-
.3 ;
1.6 t10 NET DATR
~
9 11 9 +-
o' 1 7 510 NET DATA paa m
505 NN 5.4 MIS 5INGOR[IAbAG$i[ DOSIMETER 1
006 324 4.7 10.3 +-
.3 ;
1.5 NO NET DATA 007 324 5.5 10.5 +-
.3 l 1.6 NO NET DATA 005 256 6.1 5.2 +-
.2 l
.8 NO NET DATA 009 273 4.1 10.5 +-
.3 l 1.6 t10 NET DATA 010 253 3.7 10.7 +-
.3 ;
1.6 t10 tiET DATA 011 230 4
11.7 +-
.4 ;
1.3 t10 NET DATA 012 243 1.3 11.9 +-
.4 l 1.9 N0 tlET DATA 013 222 1.5 8.7 +-
. 3 ';
1.3 NO NET DATA 1
014 208 1.8 9.6 +-
.3';
1.4 NO NET DATA 015 176 2.4 11.4 +-
.3 l 1.7 NO NET DATA 016 160 1.5 13.1 +-
.4 l 2.0 t10 t1ET DATA 019 159 3.8 11.1 +-
.3 l 1.7 N0 IIET DATA 020 139 4.7 10.0 +-
.3 l 1.5 NO NET DATA 001 001 4
10.9 +-
.3 l 1.6 NO NET DRIA 022 187 4.7 10.7 +-
.3 ;
1.6 l10 NET DATA 023 201 8.7 11.1 +-
.3 l 1.7 N0 NET DATA 024 190 7.9 10.9 +-
.3 ;
1.6 t10 t1ET DATA 025 325 6.7 10.5 +-
.3 l 1.6 NO NET DATA 026 314 10.
10.6 +-
.3 l 1.6 NO NET DATA 027 314 10.
11.8 +-
.4 l 1.8 N0 flET DATA 028 315 10.
11.0 +-
.3 l 1.7 HO NET DATA 029 186 11.
12.3 +-
.4 l 1.3 t10 NET DATR t10 TRAt4 SIT DOSE CALCULATED (TLD CONTROLS' MISSING OP OTHERWISE NOT COMPLETE)
.l 4
1
CALVERT CLIFFS FOR THE FERIOD 530105-830401 TLD DIRECT FADIATION EW!IR0tii1 ENTAL f10HITORI!iG RZIflUTH (dag.)
AVER. EXPOSURE FATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348,75-11.25 (N)
NO DATR+-NO DATR 0
11.25-33.75 (NNE)
NO DATA +-N0 DATR 0
33.75-56.25 (NE)
NO DATA +-N0 DATR 0
56.25-78.75 (ENE)
NO DATR+-N0 DATR 0
78.75-10l.25 (E)
NO DATA +-NO DATR 0
10l.25-123.75(E5El NO DRTA+-NO DATR 0
123.75-146.25(SE) 10.3 +- 0.0 1
145.25-158.75(55E) 12.5 +- 1.5 2
158.75-191.25(5) 11.7
+.7 4
191.25-2l3.75(55H) 10.9 +
.9 3
213.75-236.25(SH) 10.5 +- 2.2 2
238.25-258.75(W5W) 9.5 +- 3.7 3
258.75-291.25(W) 11.0 +
.1 2
28l.25-303.75(WNW) 10.9 +- 0.0 1
303.75-326.25(NH) 11.0 +
.4 4
326.25-348.75(NNN)
NO DATR*-NO DATR 0
01 STANCE (mi) FROM THE REACTOP VER EXPOSUPE RR E
+ IN GROUP 0-2 11.1 +- 1.5 6
2-5 ll.2 +
.5 10 25 10.4 +- 2.6 6
UPNIND CONTROL ORTA Il.5 +
.6 3
=
1 l
CLINTON l
TLD DIRECT RADIATION ENVIRONMENTAL HONITORING i
FOR THE PERIOD 821220-830405 107 DAYS FIELD TIME 79 DAYS HRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXROSURE(mR) mR/Std.0tr.
Rdm; Tot.
+- Rdm; Tot.
(dea.)
(mi.)
t-001 352 0.6 17.9 +-
.5 ;
2.7 15.9 + '
.8 ;
3.6
.5^
2.6 14.9 +-
.7 l 3.5 002 7
0.7 17.0 +-
.6 ;;
2.8 16.9 +-
.8 l 3.7 AA2 06 0.8 18.8 +-
004 165 0.5 18.1 +-
.5 l 2.7 16.1 +-
.8 l 3.6 005 187 0.5 18.2 +-
.5 t 2.7 16.2 +-
.8';
3.7
-St6 223 0.6 18.4 +-
.6 ;
2.8 16.5 +-
.8 l 3.7 007 238 0.8 17.2 +-
.5 l 2.6 15.1 +-
.7 l 3.5 e
n.t-
- n. a. o 4.o t.o +_
.c o.y 1e.a, +_
.o 0
0 v
V i
V,
c,
009 78 1.8 18.1 +-
. 5 ";
2.7 16.1 +-
.8,;
3.6 o i [j 7$
C.f jo.o k-
.E o.7
{D'.o 4_
.oi o.7 DA.
I e V
.V V
V,
L 1 V
V,
V 3 011 104 2.?
18.0 +-
.5 l 2.7 16.0 +-
.8 l 3.6 o
e o.o 6.10
.t i ed w.o is.o +-
14..g +_
.4 e
.6 w
w V
.I V w w
013 127 3.2 18.1 +-
.5 l 2.7 16.1 +-
.8 l 3.6 014 160 2.1 17.9 +-
.5 l 2.7 15.9 +-
.8 l 3.6 015 180 3.0 18.5 +-
.6 l 2.8 16.5 +-
.8 l 3.7 016 203 3.2 17.0 +-
.5 ;
2.5 14.8 +-
.7 l 3.5 is../ +_
. R. i,
?.c 6.1. 7 09.s.
- 1.. 'i l't.'(
+_
?.i v v w
018 255 2.3 17.3 +-
.5 l 2.6 15.2 +-
.7 ;
3.5 i
j e. D"
+_
.o i o. D" (140
? ? s.
- ?
17 7i i +._
.E w.c 9
.i.
i
.v V,
V V,
V
~ h oo 1'0 +_
c 6 9
n?n on?
6l0 if.i+-
l5 !
5'4 1915 l f' + _l7 l 5.5 035 505 05
.6 i +-
.5' 022 332 0.6 17.5 +-
2.6 15.4 +-
.7 ;
3.6
.5 ;
02?
358 4.6 16.3 +-
2.4 14.0 +-
.7 ;
3.4 024 20 3.9 17.4 +-
.5 ;
2.6 15.3 +-
.7 ;
3.5 025 46 5.0 17.2 +-
.5 l 2.6 15.1 +-
.7 l 3.5 e
o4
- 0. 0 co
- s.. =v 1s..a +_
.e) woi to.D T_
7 o.no e
_w vw V
I 9
V 027 9A 4.5 16.2 +-
.5':
2.4 13.9 +-
.7 ;
3.4 nop<
tis
- s.. w?
15. a. +. _
.ea,
a o.4 t o.s. 6 + _
, 7, 0.-d V
029 128 5.1 16.6 +-
.5 !
- 2. 5, 14.4 +-
.7 l 3.4 a
n
- n. o n.
iva
=. c.-
1f.o, +_
.m 4.r 1e.q t_
,o.
o,6 0
J.
V,
Vv V,
V o +_
e t
e 6.21 170 s-. w?
11 o.c w
IV
.w
.eJ,
4e.4
+_
7 o.e 10 i,
V J m v i
(177
?i-Ad.7 i.
.o i, o. D" w.t s.
j.I.-
} r. 85 14.4 +- 1.0 11 UPNIND CONTROL DRTA 16.3 +- 3.0 3
I D.C.C00K
'TLD DIRECT RADIATI0tl ENVIRONMENTAL MONITORIllG FOR THE PERIOD 821221-830412 113 DAYS FIELD TIME 88 DAYS NRC LOCATI0tl GROSS tlET EXPOSURE RATE STATION AZIMUTH /DIST EXPO 5URE(mR) mR/Std.Qtr.
l l
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 54~
1.7 19.0 t-
.6 ;
2.9 NO NET' DATA i
002 67 1.3 19.9 +-
.6 l 3.0 110 NET DATA 003 89 1.1 19.9 +-
.6 l 3.0 N0 llET DATA 004 58 0.7 19.3 +-
.6 l 2.9 N0 llET DATA 005 19 2.3 21.3 +-
.6 l 3.2 t10 flET DATA i
006 111 1.6 20.6 +-
.6 l 3.1 t10 NET DATA 007 135
'5 21.2 +-
.6 ;
3.2 N0 ilET DATA 008 158 1.4 20.1 +-
.6 l 3.0 N0 flET DATA 009 171 1.9 19.0 +-
.6 l 2.3 h0 llET DATA 010 199 1.5 20.1 +-
.6 l 3.0 t10 IIET DATA 4
011 195 3.9 20.9 +-
.6 l 3.1 N0 tlET DATA i
010' 0'00 6.6 22.1 +-
.7 l 3.3 NO HET DATA 013 179 3.9 23.0 +-
.7 ;
3.4 l10 t1ET DATA 014 151 4.4 22.8 +-
.7 l 3.4 t10 tlET DATA 015 130 4.6 24.3 +-
.7 l 3.6 N0 flET DATA i
016 110 3.7 21.2 +-
.6 l 3.2 N0 flET DATA 017 88 3.6 21.2 +-
.6 ;
3.2 110 tlET DATA 018 67 3.9 20.2 +-
.6 l 3.0 110 ilET DATA 019 24 3.8 14.9 +-
.4 ;
2.2 t10 NET DATA 020 43 3.3 22.3 t-
.7 l 3.4 t10 llET DATA 021 26 9.9 23.6 +-
.7 ;
3.5 tl0 flET DATA 00' 121 18.
19.8 +-
.6 l 3.0 N0 tlET DATA 022 121 15.
21.2 +-
.6 l 3.2 110 llET DATA 024 121 18.
23.2 t-
.7 3.5 N0 tiET DATA t10 TRANEIT DOSE CALCULATED (TLD C0 tite 0LS; MISSING OR OTHERUISE NOT COMPLETE i
{
1 1
I t
- =---.
i D.C. COOK l
FOR THE PERIOD 821221-830412 i
f TLD DIRECT RADIATION ENVIRONMENTAL MONITORING i
RZIMUTH (dag.)
AVER. EXPOSURE RATE
- IN GROUP 1
l (mR/Std.Otr.) t-Std.Dev.
348.75-11.25 (N)
NO DRTA+-NO DATR 0
l 11.25-33.75 (NNE) 15.8 +- 3.6 3
33.75-56.25 (NE) 16.6 +- 2.1 2
i 56.25-78.75 (ENE) 15.7 +
.4 3
78.75-10l.25 (E) 16.3 +
.7 2
1 l
10l.25-123.75(ESE) 16.8 +
.3 2
123.75-146.25(SE) 18.1 +- 1.7 2
- j 145.25-158.75(55E) 17.1 +- 1.5 2
i l
150.75-191.25(5) 15.7 +- 2.3 2
l 191.25-213. 75 ( 55 N 1 15.7 +
.8 3
l 213.75-236.25tSW)
NO DATA &-NO DATR 0
i 236,25-258.75(WSW)
NO DATRt-NO DATR 0
l i
258.75-201.25(W)
NO DATRt-NO DATR 0
l 281.25-303.75(HNW)
NO DRTAt-NO DATR 0
l 303.75-326.25(NN)
NO DRTAt-NO DATA 0
326.25-348.75(NNN)
NO DRTA+-NO DATA 0
l DISTANCE (mi) FR0t1 THE REACTOR RVER.EXPOEURE RATE
+ IN GROUP (mR/5td.Qtr.) + -5t d. De v.
l 0-2 15.8 +
.8 9
2-5 16.9 +- 2.0 19 l
>5 18.2 +
.8 2
UPNIND CONTROL DATA 17.0 +- 1.3 3
.. ~. -
COOPER TLD DIRECT RADIATI0t1 ENVIRONMENTAL MONITORING 4
FOR THE PERIOD 821220-830419 121 DAYS FIELD TIME 91 DAYS i
I NRC LOCATI0li GROSS 11ET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
( m i..)
+- Rdm; Tot.
+- Rdm; Tot.
001 363 2.4 16.9 +-
.5 ;
2.5 t10 NET ~ DATA 002 6
3.5 23.4 +-
.7 ;
3.5 t10 NET DATA 003 18 2.7 22.3 +-
.7 l 3.3 N0 t1ET DATA 004 16 3.2 22.1 +-
.7 l 3.3 t10 NET DATA i
005 47 1.9 22.4 +-
.7 ;
3.4 t10 tiET DATA 006 40 3.6 22.4 +-
.7 ;
3.4 N0 flET DATA 007 75 2.7 22.2 +-
.7 l 3.3 t10 t1ET DATA 008 55 2.5 22.4 +-
.7 l 3.4 t10 NET DATA 009 80 2.1 23.1 +-
.7 l 3.5 t10 NET DATA 010 98 3.7 23.5 +-
.71 3.5 t10 NET DATA 011 118 2.3 23.7 +-
.7 l 3.6 t10 tlET DATA 012 109 4.6 MISSIllG OR DAMAGED DOSIMETER 013 141 3.0 23.0 +-
.7 ;
3.5 NO NET DATA 014 126 5.6 21.6 +-
.6l 3.2 NO NET DATA 015 159 2.7 24.8 +-
.7 ;
3.7 NO NET DATA 016 167 4.9 24.1 +-
.7 ;
3.6 NO NET DATA 017 205 0.3 23.9 +-
.7 ;
3.5 t10 llET DATA 3.3 NO NET DATH Ole 186 4
14.0 +-
Oli
?13 3.0 21.9 +-
.7 i 3.3 t10 flET DATA 020 195 4.9 24.1 +-
.7 ;
3.6 N0 NET DATA 021 222 2.0 23.8 +-
.7';
3.5 NO NET DATA 022 215 5.7 23.5 +-
.7 l 3.5 N0 t1ET DAlR 023 256 1.5 23.3 +-
.7 ;
3.5 t10 t1ET DATA 024 238 5.2 23.3 +-
.7 ;
3.5 t10 llET DATA 025 276 2.2 21.9 +-
.7 l 3.3 N0 flET DATA 026 260 3.8 23.1 +-
.7 i 3.5 t10 tlET DATA 027 301 1.3 23.6 +-
.7 ;
3.5 t10 llET DATA 1
028 286 4.5 23.0 +-
.7 ;
3.4 NO NET DATA 029 324 2.8 23.1 +-
.7 l 3.5 t10 t1ET DATA 030 333 3.7 20.6 +-
.6 ;
3.1
!10 flET DATA 031 343 2.6 22.4 +-
.7 l 3.4 t10 tlET DATA 032 333 3.7 21.2 +-
.6 ;
3.2 N0 flET DATA 033 215 1.0 21.1 +-
.6 ;
3.2 t10 t1ET DATA 034 173 IS.
MISSIt1G OR DAMAGED DOSINETER 035 333 23.
22.4 +-
.7 ;
3.4 N0 flET DATA 036 210 19, 23.5 t-
.7 ;
3.5 110 ilET DATA 037 64 7.0 24.5 +-
.7 ;
3.7 t10 11ET DATA 038 329 9.0 22.0 +-
.7 l 3.3 t10-NET DATA 039 276 10.
21.5 +-
.6 ;
3.2 t10 llET DATA 040 300 2.5 23.0 +-
.7 ;
3.4 t10 NET DATA 042 93 3.5 21.2 +-
.6 ;
3.2 NO NET DATA l
043 270 2.2 23.7 +-
.7 3.5 t10 llET DATA 110 TRANSIT DOSE CALCULATED (TLD CONTROLS; MISSING OR OTHERNISE t10T COMPLE l
l l
COOPER FOR THE PERIOD 821220-330419 TLD DIRECT RADI ATION ENVIR0tii1Et1TAL l10!1ITORING i
RZIflUTH (dag. )
AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qte.) t-Std.Dev.
348.75-!l.25 (N) 15.0 +- 3.4 2
11.25-33.75
( N tie )
16.5 +
.1 2
33.75-56.25
( tJE )
16.6
+.D 3
56.25-78.75 (ENE) 17.3 +- 1.2 2
78.75-!OL.25 (E) 16.8 +
.9 3
l 10l.25-123.75(E5E) 17.6 +- 0.0 1
123,75-146.25(SE) 16.6 +
.7 2
145.25-150.75(55E) 10.2 +.3 2
150.75-191.25(5) 17.1 4-0.0 1
191.25-2l3.75(55H) 17.3 +
.9 3
213.75-236.25(SW) 17.0 4-1.1 3
236.25-258.75tu5u) 17.3 +- 0.0 2
258.75-281.25(W) 16.8 +
.7 4
281. 25-3 03. 7 5 ( UNH )
17.2 +.3 3
j 303.75-326.25(NH) 17.1 +- 0.0 1
1 326,25-348.75(NNH) 16.0 +
.6 4
1 DISTANCE (mi) FPON THE PEACTOP RVER.EXPOSUPE RATE
+ IN GROUP fn,P/5td 0tr.) +-5td.Dev.
0-2 17.1 +
.8 6
l 2-5 16.7 +- 1.1 26
>5 16.9 +
.9 6
UPHINO CONTROL DATA 17.1 +
.6 2
CRYSTAL RIVER TLD DIRECT RADIATIOt1 EllVIRONt1 ENTAL M0t1ITORING FOR THE PERIOD 821217-830415 120 DAYS FIELD TIME 111 DAYS llRC LOCATI0f4 GROSS NET EXPOSURE RATE STATION AZIfiUTH/DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
006 61-4.2
- 13. 7 +--
.4 ;
2.1 NO NET ~ DATA 007 50 3.8 14.3 +-
.4 ;
2.1 N0 tiET DATA 008 20 5.?
14.7 +-
.4 l 2.2 N0 tiET DATA 009 6
5.4 15.6 +-
.5 ;
2.3 NO NET DATA 4
010 348 5.0 16.0 +-
.5 ;
2.4 N0 llET DATA 011 334 4.8 15.7 +-
.5 l 2.4 NO NET DATA 012 318 4.8 14.2 +-
.4 l 2.1 NO NET DATA 013 79 3.8 14.7 +-
.4 l 2.2 t10 NET DATA
(
014 95 4.1 15.2 +-
.5 l 2.3 t10 11ET DATA 015 89 1.3 15.8 +-
.5 l 2.4 t10 NET DATA 016 113 5.0 13.6 +-
.4';
2.0 fl0 t1ET DATA 017 133 5.5 14.0 +-
.4 ;
2.1 110 flET DATA 018 74 8.1 14.5 +-
.4 l 2.2 t10 11ET DATA 019 127 7.6 15.1 +-
.5 ;
2.3 t10 NET DATA 020 150 12.
14.9 +-
.4' 2.2 fl0 NET DATA 021 159 13.
15.4 +-
.5 l 2.3 t10 llET DATA 022 150 20.
13.5 +-
.4 ;
2.0 NO NET DATA 023 150 20.
12.7 +-
.4 l 1.9 N0 t1ET DATA 024 150 20.
13.6 +-
.4 l 2.0 N0 flET DATA 025 56 6.1 15.5 +-
.5 ;
2.3 NO NET DATA 026 357 5.2 16.0 +-
.5 ;
2.4 t10 11ET DATA 027 90/
13.
13.7 +-
.4 ;
2.0 N0 tiET DATA 028 140 4.5 14.9 +-
.4 l 2.2 t10 NET DATA
.5 ; 2.2 i
TRANSIT DOSE =
.2
+-
l
(
1:F'iiTAL PIVEF FOP THE FEPIOD
?!21 N 30415 TLD DIFEi:T PrHI AI'uh P. !!Fim1ENT AL NONITOFitM FiZlfil_lili Llug.!
f 4 E 'I t'tV E R E Xl'OC.ljPC let til 4 ] fi GP Qlli' LmP/6td.Qtr. 3 t-- ti t al Dev.
340.?5-11.2') t ri )
12.9 +-.2 2
11.25-33.?S I rit4E i 12.1 +- U.0 1
31 ?5-5t 23 t rJ E >
l2.2 +-
.?
2 D b,.' 5 - ? u. 7 3 il flE )
I 1. ti +-
.3 2
?8.75-101.2*) IE1 12.t +-.?
4 10l.13 - 12 3. 75 6 f !iE )
11.2 +- U.0 1
12 3. 73 - 14 6. J5 t 'iE )
12.0 +-.5 3
11G. 25 - 1b0. 75 I SSL )
12.1 4-
.3 2
15 0. ? S - l'J 1. M I S )
fl0 D H I R 6 -rJO 11H Til 0
l'3 L.23-213. 75 i SbH )
tJO UHTFl*-tJO UHill 0
?l).?S-2 %.dSIGH) fl0 DATA +-tJ0 DAin 0
236 25 -250. ?'i ( L4!illi t10 UFtTttt---t10 IFti f t u
250 75 -2 01. J S i ll a tJU UllTAt -rJO DATit u
20t 25-303.75 i lirJ LJ )
tJO D ATtit -f10 DAT fi 0
103 7')-326. 25 i rJH )
IL,G t- 0.0 1
326.23-340.75 t tirJH i 1 3. 0 -+ -.1 2
01SitirJCC t m i ) FP0 r1 THC pet 1CTOP tlc T ItVER. E WPUSljF'E PH IC
+ I f1 t'.R0'JP W4Md)t r. ) + -S t,ttdlin,,,
0-2 12.9 t- 0.0 1
2 -- 5 12.0 t-
.7 9
55 12.2 +-.G 10 UP64ItlO C0flTP0L Ult TO 10.9 +- 4 3
DAVIS BESSE TLD DIRECT RADIATION ENVIROt1 MENTAL MONITORING FOR THE PERIOD 831221-830426 127 DAYS FIELD TIME 102 DAYS NRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dec.)
(mi.)
+- Rda; Tot.
+- Rdm Tot.
001 50' O.6 20.0 +-
.6 ;
3.0 NO NET; DATA 002 86 0.9 25.8 +-
.8 ;
3.9 t10 t1ET DATA 003 116 1.4 22.4 +-
.7 l 3.4 NO HET DATA j
004 172 0.8 25.8 +-
.8 l 3.9 t10 flET DATA 005 200 1.5 27.1 +-
.8 l 4.1 NO NET DATA 006 226 1.0
?7.6 +-
.8 l 4.1 t10 NET DATA 007 249 1.5 26.8 +-
.8 ;
4.0 t10 NET DATA 008 267 1.8 27.7 +-
.8 l 4.1 N0 flET DATA 004 0'85 1.5 25.1 +-
.8 l 3.8 N0 t1ET DATA 010 306 1.5 22.2 +-
.7 ;
3.3 N0 i1ET DATA 011 344 0.9 MISSIllG OR DAMAGED DOSIMETER 012 142 4.5 26.9 +-
.8 ;
4.0 NO NET DATA 013 158 4.0 25.6 +-
.8' 3.3 NO NET DATA 014 180 3.8 22.5 +-
.7 l 3.4 N0 flET DATA 015 207 4.8 25.5 +-
.8 ;
3.3 fl0 flET DATA 016 225 4.5 26.5 +-
.8 ;
4.0 N0 flET DATA 017 254 2.7 28.8 +-
.9 ;
4.3 NO NET DATA 018 269 3.0 25.7 +-
.8l 3.9 NO NET DATA 019 295 5.3 30.9 +-
.9 ;
4.5 t10 flET DATA 02n
?5 0.5 20.3 +-
.6 l 3.0 t10 NET DATA 021 132 9.7 26.7 +-
.8 ;
4.0 N0 ilET DATA 022 210 6.5 20.7 +-
.6 ;
3.1 N0 flET DATR t10 TRANSIT DGSE. CALCULATED (TLD CONTROLS ~MISSIt1G OR OTHERWISE t10T COMPLETE)
I I
e
,-g.
DAVIS BESSE FOR THE PERIOD 831221-230426 TLD DIRECT RADIATION EtiVIRONi1Et1TAL fiONITORING RZD1UTH (dag.)
AVER. EXPO 5URE FATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-It.25 (N)
NO DATA +-NO DATR 0
11.25-33.75 (NNE) 14.4 +- 0.0 1
33,75-56.25 (NE) 14.2 +- 0.0 1
t 56.25-78.75 (ENE)
NO DRTA+-NO DATA 0
78.75-101.25 (E) 18.3 +- 0.0 1
10l. 25-12 3.75 (ESE) 15.9 +- D.0 1
12 3. 75 - 14 6. 25 ( S E )
19.0 +- 0.0 1
14 5. 25-16 8. 75 ( 55E )
18.1 +- B.0 1
150.75-191.25(5) 17.1 +- 1.7 2
191.25-2l3.75(55N) 18.5 +
.B 2
213.75-236.25(SW) 19.1 +
.E 2
236.25-258.75(W5W) 19.7 +- 1.0 2
250.75-281.25(W) 18.9 +- 1.0 2
281.25-303.75(UNU) 19.9 +- 2.9 2
303.75-328.25(NH) 15.7 +- 2.0 1
326.25-348.75(NNN)
NO DATA +-NO DATR 0
DISTANCE (mt) FROM THE REACTOP RVER. EXPOSURE RATE
+ IN GROUP
( n.R/ 5 t d. Q t r. ) + -5t d. De v.
Q-2 17.4 +- 2.0 11 2-5 18.3 +- 1.3 7
>5 21.9 +- B.O 1
UPNIND CONTROL DATA 16.8 +- 3.0 2
DIABLO CAtlYOH TLD DIRECT RADIATION Et1VIR0tiMEt1TAL N0t1ITORING FOR THE PERIOD 821222-830420 120 DAYS FIELD TIME 90 DAYS t1RC LOCATIO!i GROSS tlET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.
i (dec.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
t 001 125 1.0 25.3 +-
.8 ;
3.3 20.4 +-' 1.0 ;
4.6 002 119 4.2 23.3 +-
.7 ;
3.5 18.4 +-
.9 ;
4.4 1
003 107 6.9 22.4 +-
.7 ;
3.4 17.5 +-
.9 ;
4.3 004 109 11.
MISSIllG OR DAMAGED DOSIMETER 005 113 14.
23.8 +-
.7 ;
3.6 18.9 +-
.9 ;
4.5 i
006 68 9.6 22.3 +-
.7 l 3.3 17.3 +-
.9 '
4.3 1
007 359 11.
20.2 +-
.6 l 3.0 15.3 +-
.9 ;
4.0 008 359 6.6 19.5 +-
.6 l 2.9 14.5 +-
.8 l 3.9 009 339 4.7 17.9 +-
.5 l 2.7 13.0 +-
.8 l 3.8 011 332 1.3 18.6 +-
.6 l 2.3 13.7 +-
.8 l 3.9 012 37 21, 23.6 +-
.7 l 3.5 18.7 +-
.9 l 4.4 013 37 21.
22.5 +-
.7 l 3.4 17.6 +-
.9 ;
4.3 014 37 21.
24.2 +-
.7 l 3.6 19.3 +-
1.0 l i
018 162 9.3 MISSI!1G OR DAMAGED DOSIMETER 4.5 TRANSIT DOSE =
4.9
+-
.6 ; 2.7
,1 a
e i
i i
i
)
I 1
)
i f
DIABLO CANYON FOR THE PERIOD 821222-830420 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIt1UTH (dag.)
NET RVER. EXPOSURE RATE
- IN GROUP (mR/Std.Otc.) t-Std.Dev.
348.75-ll.25 (N) 14.9 +
.5 2
11.25-33.75 (NNE)
NO DRTA+-NO DATR 0
33.75-56.25 INE)
NO DRTA+-NO DATR 0
i 56.25-78.75 (ENE)
- 17. 3 +- 0. 0 1
78.75-101.25 (E)
NO DRTA+-NO DATR 0
10l.25-123.75(ESE) 18.2 +
.7 3
123.75-146.25(SE) 20.4 +- 0.0 1
14 5.25-168. 75 ( 55 E )
NO DRTR&-N0 DRTR 0
160.75-191.25(5)
NO DRTR&-NO DRTR 0
19 L.25-213.75 (55N)
NO DRTR&-NO DRTR 0
213.75-236.25(SW)
NO DRTA&-NO DATR 0
236.25-250.75(W5W)
NO DATAt-NO DATR 0
258.75-281.25(W)
NO DATAt-NO DATR 0
281.25-303. 75 ( W NW )
NO DATAt-NO DATR 0
303.75-326.25(NN)
NO DRTAt-NO DATR 0
326,25-348.75(NNH) 13.3 +
.5 2
DISTRNCE(mi) FR0t1 THE REACTOR NET RVER. EXPOSURE RRTE
+ IN GROUP
)
inP/5td.Qtr.) +-5td.Dev.
B-2 17.0 +- 4.7 2
2-5 15.7 +- 3.8 2
>5 16.7 +- 1.8 5
UPHIND CONTROL DATA 18.5 +
.9 3
DRESDEN TLD DIRECT RADIATI0ti ENVIROHf1Et1TAL f10HITORING FOR THE PERIOD 821221-830405 106 DAYS FIELD TIiiE 78 DAYS t1RC LOCATION GROSS tiET EXPOSURE RATE STATION AZIfiUTH/DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.>
+- Rdm; Tot.
+- Rdm; Tot.
001 70' 4.2 19.9 +-
.6 ;
3.0 tIO NET' DATA 002 92 3.9 18.3 +-
.5 l 2.7 N0 tiET DATA 003 119 3.2 18.9 +-
.6 l 2.8 HO NET DATA 004 134 1.3 17.0 +-
.5 l 2.6 NO HET DATA 005 115 1.5 17.6 +-
.5 ;
2.6 N0 t1ET DATA 006 180 1.9 18.7 +-
.6 l 2.3 fl0 I1ET DATA 007 179 0.5 19.4 +-
.6 l 2.9 N0 !1ET DATA 008 166 0.7 16.7 +-
.5 ;
2.5 NO NET DATA 009 205 0.5 18.3 +-
.5 ;
2.7 fl0 ilET DATA 010 224 0.7 23.3 +-
.7 l 3.5 NO NET DATA 011 250 0.9 19.0 +-
.6 l 2.9 NO NET DATA Oli 063 1.6 19.6 +-
.6 l 2.9 N0 llET DATR 4
013 180 4.0 17.5 +-
.5 l 2.6 110 t1ET DATA 014 158 4.5 111SSING OR DAf1 AGED DOS!!1ETER 015 137 4.2 20.5 +-
.6 ;
3.1 t10 NET DATA 016 134 8.4 17.7 +-
.5';
2.7 N0 llET DATA 017 189 7.4 19.6 +-
.6 ;
2.9 N0 NET DATA 018 203 4.1 15.5 +-
.6 l 2.8 ti0 NET DATA 019 231 3.2 19.2 +-
.6 l 2.9 110 NET DATA 020 244 6.4 15.5 +-
.5 l 2.3 t10 NET DATA 021 258 8.6 18.4 +-
.6 ;
2.3 110 t1ET DATA 022 269 4.4 15.9 +-
.5 ;
2.4 t10 IIET DATA 023 295 3.3 19.5 +-
.6 ;
2.9 HO NET DATA 024 311 3.9 17.6 +-
.5 ;
2.6 t10 NET DATA 025 340 4.7 21.5 +-
.6 l 3.2 t10 t1ET DATA 026 7
4.4 17.4 +-
.5 l 2.6 N0 t1ET DATA 027 1
2.0 20.1 +-
.6 l 3.0 t10 NET DATA 028 327 1.7 24.6 +-
.7 l 3.7
!10 t1ET DATA 029 318 1.4 20.2 +-
.6 l 3.0 t10 NET DATA 030 301 1.9 MISSING CR DAf1 AGED DOSIl1ETER 031 30 1.5 20.8 +-
.6 ;
3.1 110 t1ET DATA 032 48 1.9 21.6 +-
.6 ;
3.2 NO NET DATA 033 76 1.4 22.3 F-
.7 ;
3.3 t10 NET DATA 034 90 1.4 16.6 +-
.5 ;
2.5 N0 tlET DATA 035 26 4.5 19.4 +-
.6 ;
2.9 t10 tlET DATA 036 42 3.6 18.9 +-
.6 l 2.8 HO NET IJATA 037 52/
11.
21.3 +-
.6 ;
3.2 N0 ilET DATA 035 274 23.
18.9 +-
.6 ;
2.8 t10 I1ET DATA 039 274 23.
18.5 +-
.6 ;
2.8 N0 tlET DATA 040 275 24.
20.8 +-
.6 3.1 t10 NET DATA t10 TRANSIT DOSE CALCULATED (TLD C0tlTROLS;lilSSING OR OTHEPHISE 110T C0l1PLETE I
DRESDEN FOR THE PERIOD S21221-830405 1
TLD DIRECT RADIATION ENVIRONMENTAL MONITORING u
i RZ D1UTH (deg. )
AVER. EXPOSURE RATE
$ IN GROUP
's (mR/Std.Qtr.) t-Std.Dev.
?
348.75-11.25 (N) 15.9 +- 1.6 2
f 11.25-33.75 (NNE) 17.1 +
.B 2
33.75-56.25 (NE) 17.5 +- 1.3 3
- l l
56.25-78.75 (ENE) 17.9 +- 1.5 2
78.75-!Ol.25 (E) 14.8 +- 1.0 2
/
10l.25-123.75(ESE) 15.5 +
.B 2
123.79-146.25(5E) 15.8 +- 1.6 3
146.25-158.75(55E) 14.1 +- B.O 1
168.75-191.25(5) 16.0 4-.8 4
19l.25-2t3.75(55H) 15.5 +
.1 2
213.75-236.25(SH) 10.0 +- 2.5 2
236.25-258.75(P5W) 15.0 +- 1.6 3
258.75-281.25(U) 15.1 +- 2.2 2
281.25-303.75(WNW) 16.6 +- 0.0 1
l 303.75-328.25(NH) 18.0 +- 1.8 2
e 326,25-348.75(NNN) 19.5 +- 1.9 2
i
~
DISTANCE (mi) FROM THE REACTOR RVER. EXPOSURE RATE
+ IN GROUP t
(mR/5td.Qtr.) + -5t d. De v.
B-2 16.7 t-2.0 16 2-5 15.9 +- 1.2 14
>5 15.7 +- 1.8 5
)
UPNIND CONTROL ORTA 16.5 +- 1.0 3
c;.
6 h
4
.3 J
M
.v.w,-,.e
--g.
-sp-e
~-
m n
,g-%
e
,z.
~
-e s
~
DUANE ARNOLD TLD DIRECT RADIATIO!! ENVIR6HMEllTAL N9NIf0 RING
- 1 f
FOR THE PERIOD 821221-830411 112 -LP.Y$
< v FIELD TIME 92 DAYS
/
'f i
ilRC LOCATION GROSS,
1, t1ETENPOSURE' RATE ST9 TION AZIMUTH /DIST EXPOSURE (mRf' mR/ S t d. 0.i r, '
(dea.)
(mi.)
+- Rdm; Tot.
+- Rda; Tot.
s 001 163 9.7 21.4 +-
.3:1 3.2
- 19. 0..+ -~
.8 ;
3.7 002 170 6.2 23.8 '-
.7-3.6 21.4 +-
.8 t 4.0 003 180 3.5..
19.1 +-
.Fl 2.9 16.7 +-'
.7 l 3.4 004 216 2.4 "
~15.3 Us
.51 2.3 13.0 +-
.6 ;
2.9 005 201 2.5' -
MISSIRe OR DAMAGED DOSIMETER
~
006 213 1.0 20.3 +-
.6 ;
3.0 17.9 --
.7 ;
3.5 e
.o o.o
. n. +
90.7 +_
.[
O4 on..?
'e a
9.49
..a. n.7 V q V V 1.
ww 1
q w
w 7 i
'd.9 n
4
- i n n
..1 P-n 67q 4
c4 10,.4.
.D
- 4. 3 -
AD e,f
,000 die
- 1. es t"
V t
a e
e
.4.D o.1 14 e
.I g
,a. n. o oon
- 1. n.
1l. a. 4 -
.s.
o. =J V
e wvC g
w 010 328
,1. 5 18.4 +-
.6 l 2.8 16.0 +-
.7 l 3.3 All 3tL .1.0 19.3 +-
.6' 2.9 16.9 --
.7 l 3.4
- e e
^ m.x
- 1.. w>
io.4 +_
.D 9. a_
1 -[. a. + _
o.4
.to d.-
.I g
V s
g w
w 7
013 -
237 0.5 18.4_+-
.6 l
- 2. 8 -
16.0 +-
.7 l 3.3
_014 259 3.9 18.0 +-
.5 ;
2.7 15.6 9-
.7 l-3.2 015 272 5.0 MISSING OR DAMAGED DOSIMETER'
~
l a,. 5, +-
.6 ;
2.8 16.2 4 -
3.3 285
-.0 18 016,'
u it,.n t-
.c, d.d
,8 a,c.c.
4.3 n
.c +-
.D 2
s.i ;
ett c.
q 018-340 4.5
" 16.T +-
.5 t 2.4 13.9 v-
.6 l 3l0 ~
019
~291
- 15. ~
- 18.2 +-
.5 l
- 2. 7, 15l9 +-
.7,
- 3. 3, 4
e
- o.. e r en.
- o e,
tv. c 2_
.s.
o.t tea.n +_
.c vs s
w 021 291 15.
- 17. 0' +-
.'5,;
2.5 1.4. 6 ' + -
.c ;
3.1 022 358 6!1 17.2 +.-
.5le2,.6 IJ.8 +-
.7 ;
3,.1
- e w
c
. e
.a 1c.o, t_
.D,, e.o, n e o.-
7 9.a e. o r2
..e y
- e..
024 28 3.0 18.6 +-
.6, 2.8 16.12 +-
.-7 t
3.3 025 29
- 3. 5-17.4 +-
.5 ; -2.6 15.0,+-'
.7 !.'3.2 "
026 64 3.8 17.9 +-
.5 l 2.7 15.5'42
.? :
3.2 027 50 1.9 15.1 +-
.5 l 2.3 1248 +-
.6 l 2.9
.17.6 +-
.5 ;
2.6 15.3 +-
.7 ;,3.2 028 72 2.3 7 f
029 91 3.0 15.8 +-
.5 l 2.4 13.5 +-
.6 l 03.0 030 93 1.8 18.7 +-
.6 ;
2.8 16.3 +m
.7 ;
3.3' 031~
113 2.0 19.5 +-
.6 ;
2,9 -
I'T.i +
,.7 ;
3.4
. 5 ' ' 2. 4 ~
- 13. 9' +-
.6 l 3.0 030 141 1.6 16.2 +-
15 1.5 14.8. +-
. 4 i. '~ 2 J2 12 5. +-
.,6
,2. 9
- 033, t,r,3 6 -
s U,04 c
1..<.
1D.D t-
.es; c.o 14.s +-
.c ;
V.1 035 153 4.2 16.2 +-
.5 l 2.4 13.9 +-
.6 ;
3.0 036
.135 4.1 16.9 +-
.5 l 2.5 -
T4.6 +-
7l
-3.1 2.7
- 15. 6 +- f e. 7' ;
3.2 037 lif
'4. 6 17.9 +-
.5 ; ??.8 g
.6 l 16.2 +-f
.7 ;
3.3 OSS 123 5.1 18.6 +-
039 132 7.0 MI:lIf1G OR DRNRUED DOSIMETER
'040
. 139 7.6 21.1 +-
.E ;
3.2
-18.7 +-
.8 ;
3.6
~
'7?ANSIT' DOSE =
2.0
+-
.4 ; 1.9
~
M k
/
8
/
=
e*
p j
p-f t
4 f,
a W
_/
- I l
'y g
, e 9
f.
T'
DURtiE ARtiOLD FOR THE PERIOD S21221-830411 TLD DIRECT RALI ATID" EtWIR0!ii1EliTAL l10HITORItiG RZU1UTH (dog.)
NET AVER. EXPOSURE PATE 4 IN GROUP (mR/Std.Otr.) t-Std.Dev.
348.75-It.25 (N) 14.9 +- 2.1 3
11.25-33.75 (NNE) 16.2 +- D.0 1
33.75-56.25 tNE) 13.9 +- 1.6 2
)
56.25-78.75 (ENE) 15.4 +.2 2
78.75-10l.25 (E) 14.9 +- 2.0 2
10l.25-123.75(ESE) 16.3 +
.8 4
123.75-146.25(SE) 15.7 +- 2.6 3
14 6. 25 - 150. 75 ( 55 E )
15.2 4-3.4 3
168.75-191.25(5) 17.5 4-3.5 3
19 t. 25-2 l 3.75 ( 55H) 17.9 4- 0.0 1
213.75-236.25(SH) 13.0 4- 0.0 1
236.25-258.75(W5W) 16.1 +- 3.0 2
258.75-281.25(W) 15.8 +
.3 2
28l.25-303.75(WNW) 15.4 +- 1.1 2
303.75-326.25(NN) 16.2 +
.2 2
326.25-348.75(NNN) 15.4 +- 2.2 2
DISTANCE (mi) FROM THE PEACTOP NET RVER.EXPOSUPE RATE
+ IN GROUP (mP/5td.0tr.) + -St d. De v,
D-2 15.8 +- 2.1 14 2-5 15.0 +- 1.2 15
>5 18.0 +- 2.5 5
UPNIND CONTROL DRTA 15.3 +
.6 3
W
FARLEY TLD DIRECT RADIATI0t1 Et1VIR0t1 MENTAL MONITORING FOR THE PERIOD 821221-830414 115 DAYS FIELD TIME 94 DAYS NRC LOC.^4T I0t1 GROSS NET EXPOSIAE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0.,.
(dec.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 268 14.
20.5 +-
.6 ;
3.1 15.9 +-'
.8 ;
3.6 002 252 7.8 18.8 +-
.6 l 2.8 14.2 +-
.7 ;
3.4 003 217 6.1 00.5 +-
.6 ;
3.1 15.9 +-
.8 l 3.6 004 155 5.7 22.3 +-
.7 ;
3.3 17.6 +-
.8 ;
3.8 005 170 5.1 20.1 +-
.6 l 3.0 15.5 +-
.8 l 3.6 006 197 4.5 18.9 +-
.6 ;
2.3 14.4 +-
.7' 3.4 007 191 2.4 22.3 +-
.7 l 3.3 17.6 +-
.8 l 3.8 4
008 200 1.?
20.4 +-
.6 ;
3.1 15.8 +-
.8 l 3.6 009 220 1.2 19.2 +-
.6 l 2.9 14.6 +-
.7 l 3.5 010 254
.9 19.2 +-
.61 2.9 14.7 +-
.7l 3.5 011 300
.9 20.1 +-
.6 ;
3.0 15.5 +-
.8 ;
3.6 012 319 1.1 21.6 +-
.6 ;
3.2 17.0 +-
.8 l 3.7 013 338 1 i 00.0 +-
.6 l 3.0 15.4 +-
.8 ;
3.6 014 256 1?
00.9 +-
.6 ;
3.1 16.2 +-
.8 l 3.7 015 16 1.3 26.7 +-
.8 l 4.0 21.9 +-
.9 l 4.4 016 264 1.6 20.9 t-
.6 ;
3.1 16.2 +-
.8 l
?.?
017 253 3.5 22.0 +-
.7 l 3.3 17.3 +-
.8 ;
3.8 0'A 033 3.2 20.6 +-
.6 l 3.1 16.0 +-
.8 3.6 010
?67 4.5 22.7 +-
.7 ;
3.4 18.0 +-
.8 ;
3.9 020 295 3.8 23.3 +-
.7 l 3.5 18.6 +-
.8 l 3.9
.8~
3.6 021 315 44 90.3 +-
.6 ;
3.0 15.7 +-
.7 ;
022 332 4.3 19.5 +-
.6 ;
2.9 15.0 +-
3.5
.7 ;
3.2 023 251 4.5 17.1 +-
.5 :
2.6 12.6 +-
.8 ;;
3.5 024 32 5.3 19.8 +-
.6 ;
3.0 15.2 +-
025 54 6.2 17.3 +-
.5 l 2.6 12.9 +-
.7 l 3.2 026 64 5.5 19.4 t-
.6 l 2.9 14.8 +-
.7 l 3.5 027 88 4.7 18.9 +-
.6 l 2.8 14.4 +-
.7 l 3.4 028 124 5.1 19.5 +-
.6 l 2.9 14.9 +-
.7 ;
3.5 029 153 4.1 18.9 +-
.6 ;
2.8 14.3 +-
.7 ;
3.4 030 142 3.6 18.0 +-
.5 ;
2.7 13.5 +-
.7 ;
3.3 031 130 3
17.1 +-
.5 ;
2.6 12.6 +-
.7 ;
3.2 032 110 2.8 17.6 +-
.5 ;
2.6 13.1 +-
.7 l 3.3 n_ a_ s_
rR.
0.<
10.? +-
.=s '
?.7
- 13. Ps +-
. 'c ',
'4 034 58 2.2 MISSING OR DAMAGED DOSIMETER v.
v 035 34 2.4 MISSING OR DAMAGED DOSIMETER 036 19 2.7 21.8 +-
.7 ;
3.3 17.1 +-
.8 ;
3.8 037 284 10 22.3 +-
.7 l 3.3 17.6 +-
.8~;
3.8 038 289 15.
MISSING OR DAMAGED DOSIMETER 039 293 15.
16.4 +-
.5 ;
2.5 12.0 +-
.7 ;
3.1
.5 ; 2.2 TRANSIT DOSE =
3.9 k
)
FARLEY FOR THE PERIOD 821221-930414 TLD DIRECT RADIATI0t1 E!NIR0tlNEt1TAL f10!1ITORIt1G RZIttuTH (dag.)
NET AVER. EXPOSURE RATE
- IN GROUP (mP/Std.Qte.) t-Std.Dev.
348.75-11.25 (N)
NO DRTA+-NO DATR 0
11.25-33,75 (NNE) 18.1 +- 3.4 3
33.75-56.25 (NE) 12.9 +- 0.0 1
56.25-78.75 (ENE) 14.3 +
.7 2
78.75-10t.25 (E) 14.4 +- 0.0 1
10l.25-123.75(E5E) 13.1 +- 0.0 1
123.75-146.25(SE) 13.7 +- 1.2 3
145.25-160.75(55E) 15.0 +- 2.3 2
158.75-191.25(5) 16.5 +- 1.5 2
191.25-213. 75 ( 55 H )
15.1 +- 1.0 2
213.75-236.25(SW) 15.5 +
.B 3
238.25-258.75(H5W) 15.0 +- 1.8 5
258.75-201.25(H) 16.7 +- 1.1 3
28l.25-303.75(HNU) 17.1 +- 2.2 2
303.75-326.25(NN) 16.3 +
.9 2
326.25-348.75(NNN) 15.2 +
.3 2
DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP (mR/5td.0tr.)
+-5t d. De v.
B-2 16.4 +- 2.2 9
2-5 15.3 +- 2.0 16 1
>5 15.2 +- 1.3 9
UPNIND CONTROL DATA 14.8 +- 4.0 2
FERMI TLD DIRECT RADIATION ENVIRONMENTAL HONITORING FOR THE PERIOD 821221-830414 115 DAYS i
FIELD TINE 59 DAYS J
i NRt LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 38' 2.1 17.6 +-
.5 ;
2.6 17.4 + ~ 1.0 ;
4.8 002 22 2.3 20.0 +-
.6 ;
3.0 21.1 +-
1.1 ;
5.3 003 350 1.8 21.3 +-
.6 ;
3.2 23.2 +-
1.1 l 5.5 004 345 1.9 17.8 +-
.5 l 2.7 17.7 +-
1.0 l 4.8 005 346 1.4 18.8 +-
.6 l 2.8 19.3 +-
1.0 l 5.0 2
l 006 310 1.3 18.3 +-
.5 ;
2.7 18.6 +-
1.0 l 4.9 007 298 1.4 19.1 +-
.6 l 2.9 19.8 +-
1.0 l 5.1 008 277 1.6 18.6 +-
.6 l 2.3 19.0 +-
1.0 l 5.0 009 238 1.0 19.9 +-
.6 l 3.0 20.9 +-
1.1 l 5.2 010 225 1.5 18.1 +-
.5 ;
2.7 18.2 +-
1.0 ;
4.9 011 193 0.8 18.2 +-
.5 ;
2.7 18.3 +-
1.0 ;
4.9 012 183 0.9 19.0 +-
.6 t 2.9 19.6 +-
1.0 ;
5.1 013 175 0.8 17.9 +-
.5 l 2.7 17.9 +-
1.0 ;
4.8 2.8 19.4 +-
1.0 ;
5.0
.6' 014
?60 1.7 18.9 +-
.6 ;;
2.9 20.6 +-
1.1 ;
5.2 015 245 2.5 19.6 +-
016 236 5.0 19.3 +-
.6 l 2.9 20.0 +-
1.1 l 5.1 017 225 6.8 17.8 +-
.5 l 2.7 17.7 +-
1.0 l 4.8 018 250 7.8 17.4 +-
.5 l 2.6 17.1 +-
1.0 ;
4.8 i
019 277 6.0 18.4 +-
.6';
- 2...
18.7 +-
1.0 ;
4.9 020 29r c.0 22.0 +-
.i l 3.3 24.1 +-
1.2 l 5.7 021 320 3.8 19.1 +-
.6 ;
2.9 19.7 +-
1.0 ;
5.1 022 340 4.7 19.2 +-
.6 l 2.9 19.9 +-
1.0 ;
5.1 023 358 4.3 22.2 +-
.7 ;
3.3 24.4 +-
1.2 l 5.7 024 23 5.0 20.6 +-
.6 ;
3.1 22.0 +-
1.1 l 5.4 025 25 7.0 18.0 +-
.5 ;
2.7 18.0 +-
1.0 l 4.9 026 0
7.0 18.5 +-
.6 l 2.8 18.9 +-
1.0 l 5.0 027 342 8.0 18.9 +-
.6 l 2.8 19.4 +-
1.0 ;
5.0 028 320 9.5 18.4 +-
.6 l 2.8 18.7 +-
1.0 ;
5.0 029 290 11.
18.1 +-
.5 l 2.7 18.3 +-
1.0 ;
4.9 030 270 10.
MISSING OR DAf1 AGED DOSIMETER 031 945 10.
18.2 +-
.5 ;
2.7 18.4 +-
1.0 ;
4.9 j
032 220 10.
19.6 +-
.6 l 2.9 20.5 +-
1.1 ;
5.2 033 270 15.
18.1 +-
.5 l 2.7 18.2 +-
1.0 ;
4.9 034 270 15.
18.3 +-
.5 l 2.7 18.5 +-
1.0 ;
4.9 035 290 16.
17.9 +-
.5 l 2.7 17.9 +-
1.0 ;
4.8 036 350 0.8 18.1 +-
.5 l 2.7 18.2 +-
1.0 ;
4.9 037 330 0.7 18.9 +-
.6 ;
2.8 19.4 +-
1.0 l 5.0 038 310 0.7 21.5 +-
.6 ;
3.2 23.5 +-
1.1 l 5.6 039 23/
10.
18.3 +-
.5 ;
2.7 18.6 +-
1.0 l 4.9 040 0
9.0 18.0 +-
.5 ;
2.7 18.0 +-
1.0 l 4.9 041 348 9.0 20.4 +-
.6 ;
3.1 21.7 +-
1.1 ;
5.3 TRANSIT DOSE =
6.1
+-
.4, 1.7 i
)
FERMI F0F THE FERIOD S21221-810414 TLD DIRECT RADI ATION EtP/IRONMENTAL MONITORING RZIt1UTH (deg.)
NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-ll.25 (N) 2 0. 5 +- 3. 0 5
11.25-33.75 (NNE) 19.9 +- 1.9 4
33.75-56.25 (NE)
!?.4 +- 0.0 1
56.25-78.75 (ENE)
NO DRTA+-NO DATR 0
78.75-10l.25 (E)
NO DATA +-NO DATA 0
10l.25-123.75(ESE)
NO DRTA+-NO DATR 0
123,75-146.25(SE)
NO DATA +-NO DATR 0
145.25-158.75(55E)
NO DRTR&-NO DRTR 0
158.75-191.25(5) 18.8 4-1.2 2
19 L.25-213.75 (55N) 18.3 +- 0.0 1
213.75-236.25(SW) 19.1 4-1.3 4
238.25-258.75(W5H) 19.3
-t-1.8 4
258.75-281.25(H) 19.0 +-
.4 3
28l.25-303.75(WNH) 20.7 +- 3.0 3
303.75-328.25(NN) 2 0.1 +- 2. 3 4
326.25-348.75(NNN) 19.6 +- 1.3 6
c DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP (nR/5td.Qtr.)
+-5t d. De v.
0-2 19.5 +- 1.7 15 2-5 20.7 +- 2.0 8
>5 19.2 +- 1.8 14 UPNIND CONTROL DATA 18.2 +
.3 3
FITZPATRICK/l11HE Hl.
TLD DIRECT RADI ATIO!1 E!1VIR0tiMEllTAL N0t11TORIt1G FOR THE PERIOD 821221-830412 113 DAYS FIELD TIME 90 DAYS llRC LOCATI0l1 GROSS t1ET EXPOSURE RATE STATI0t1 AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 230 6.9 18.6 +-
.6 ;
2.3 14.5 +-~
.8 ;
3.6 002 184 14 19.8 +-
.6 l 3.0 15.7 +-
.8 l 3.7 003 122 8.4 17.8 +-
.5 ;
2.7 13.6 +-
.7 l 3.5
.6 2.8 14.6 +-
.8 l 3.6
.6 l 004 76 10.
18.8 +-
2.9 15.2 +-
.8 ;
3.7 005 91 6.8 19.3 +-
006 112 4.3 19.0 +-
.6 l 2.9 14.9 +-
.8~;
3.6 007 138 4.3 18.3 +-
.5 ;
2.7 14.1 +-
.8 l 3.5 OOS 152 3.6 18.7 +-
.6 ;
2.3 14.5 +-
.8 l 3.6 009 183 3.9 19.4 +-
.6 ;
2.9 15.2 +-
.8 ;
3.7 010 205 4.5 19.3 +-
.6 ;
2.9 15.1 +-
.8 ;
- 3. 7 011 220 4.4 19.5 +-
.6 l 2.9 15.4 +-
.8 ;
3.7 012 230 6.1 20.1 +-
.6 l 3.0 15.9 +-
.8 ;
3.8 013 245 1.8 19.4 +-
.6 l 2.9 15.2 +-
.8 l 3.7 014 223 1.5 MISSING OR DAMAGED DOSIMETER 015 204 0
'0.4 +-
.6 ;
3.1 16.2 +-
.8 ;
3.8 016 181 1.3 19.8 +-
.6';
3.0 15.7 +-
.8 ;
3.7 017 157 1.9 19.9 +-
.6 l 3.0 15.7 +-
.8 l 3.7 018 137 1.i 19.6 +-
.6 l 2.9 15.4 +-
.8 l 3.7 019 115 1.2 19.2 +-
.6 ;
2.9 15.0 +-
.8 l 3.6 020 92 1.1 19.6 +-
.6 l 2.9 15.5 +-
.8 ;
3.7 021 229 19.
18.6 +-
.6 l 2.3 14.4 +-
.8 ;
3.6 022 229 19.
19.5 +-
.6 ;
2.9 15.3 +-
.8' 3.7 023 229 19.
19.7 +-
.6 ;
2.9 15.5 +-
.8 ;
3.7 024 196 8
18.1 +-
.5 ;
2.7 14.0 +-
.8';
3.5 025 168 7.2 19.0 +-
.6 ;
2.9 14.9 +-
.8 l 3.6 026 152
.6 20.6 +-
.6 ;
3.1 16.4 +-
.8 l 3.8 TRAtiSIT DOEE =
4.1
+-
.5 ; 2.2
~
1
)
i FITZPATRICK/NINE MI.
FOR THE PERIOD 821221-830412 1
i TLD DIRECT RADIATION ENVIRONMENTAL MONITORING t
j RZINUTH (dag.)
NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Cte.) t-Std.Dev.
4 348.75-11.25 (N)
NO DRTA+-NO DATR 0
i i
11.25-33.75 (NNE)
NO DRTA+-NO DATR 0
33.75-56.25 (NE)
NO DRTA+-NO DATR 0
56.25-78.75 (ENE) 14.6 +- D.0 1
4 i
78.75-10l.25 (E) 15.3 +
.2 2
i i
101.25-123.75(ESE) 14.5 +
.8 3
123.75-146.25(SE) 14.8 +
.9 2
l l
14 6.25-168. 75 ( 55E )
15.1 4-
.9 4
160.75-191.25(5) 15.5 4-
.3 3
1 l
19t.25-213.75(55N) 15.1 4-1.1 3
15.3 4-
.7 3
4 236.25-258.75(WSW) 15.2 +- 0.0 1
I 258.75-381.25(W)
NO DATA +-NO DATR 0
i e
28 l.25-303.75 (WNW)
NO DRTAt-NO DATR 0
'l 303.75-326.25 (NN )
NO D AT At-NO DATR 0
i 1
326.25-348.75(NNN)
NO DRTR+-NO DATR 0
1
.I I
I t
i DISTANCE (mi) FR0t1 THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP tmR/5td Qtr.) + -5t d. De v,
0-2 15.7 +
.5 8
i
]
2-5 14.9 +
.5 8
>5 14.8 +
.B 8
UPHIND CONTROL DRTA 15.1 +
.6 3
FT. CALHOUN TLD DIRECT RADIATI0t1 E11VIR0t1 MENTAL MONITORING FOR THE PERIOD 821221-830422 123 DAYS FIELD TIME 100 DAYS t1RC LOCATION GROSS HET EXPOSURE RATE STATI0rl AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 358 2.0 22.5 +-
.7 3.4 N0 t1ET' DATA 002 351 4.6 23.2 +-
.7-3.5 t10 t1ET DATA 003 30 25 20.7 +-
.6 l 3.1 N0 t1ET DATA 004 27 4.6 22.5 +-
.7 l 3.4 t10 t1ET DATA 005 53 1.9 21.8 +-
.7 l 3.3 t10 t1ET DATA 006 37 3.9 23.2 +-
.7 l 3.5 N0 tiET DATA 007 76 2.3 23.9 +-
.7 l 3.6 t10 f1ET DATA 008 54 5.2 24.2 +-
.7 l 3.5 N0 t1ET DATA 009 10d 2.3 20.6 *-
.6 l 3.1 NO NET DATA i
010 88 5.6 21.7 +-
.7 l 3.3 t10 NET DATA 011 l ')-)
??
?4.0 +-
.7 ;
3.6 NO NET DATA 012 105 5.7 22.4 +-
.7 ;
3.4 N0 NET DATA 013 145 1.9 24.7 +-
.7 l 3.7 N0 llET DATA 014 128 5.5 24.6 +-
.7 l 3.7 t10 t1ET DATA 015 157 1.9 24.0 +-
.7*
3.6 NO NET DATA 016 150 4.9 23.6 +-
.7 ;
3.5 110 t1ET DATA 017 173 0.5 24.5 +-
.7 ;
3.7 N0 11ET DATA 018 173 5.3 24.8 +-
.7 ;
3.7 t10 NET DATA 019 212 2.5 23.9 +-
.7 l 3.6 t10 tiET DATA 020 20j 5.}
2j.2+-
.7 l 3.j t10 t1ET DATA chi zod z.e 43.9 +-
s.
N0 t1ET DATA 022 224 4.6 22.9 +-
.7 3.4 t10 NET DATA 023 239 0.6 24.6 +-
.7 ;
3.7 t10 NET DATA 024 243 6.9 MISSIt1G OR DAMAGED DOSIMETER 025 269 3.3 24.6 +-
.7 3.7 t10 t1ET DATA 026 262 5.9 25.2 +-
.8 l 3.8 t10 t1ET DATA 1
027 288 2.8 MISSING OR DAMAGED DOSIMETER 028 292 5.0 23.3 +-
.7 ;
3.5 N0 t1ET DATA 029 311 2.4 23.4 +-
.7 l 3.5 NO HET DATA 030 310 5.5 24.7 +-
.7 l 3.7 N0 t1ET DATA 031 340 2.3 21.2 +-
.6 l 3.2 t10 i1ET DATA 0??
'38 5.3 21.9 t-
.7 ;
3.3 t10 NET DATA 033 182 0.5 21.4 +-
.6 ;
3.2 N0 t1ET DATA 035 127 2.2 21.4 +-
.6 l 3.2 t10 t1ET DATA
.5' 2.6 N0 NET DATA 039 150 5.0 17.6 +-
.7 ;
3.5 t10 NET DATA 040 73 9.5 23.1 +-
.7 ;;
3.3 N0 t1ET DATA 043 29 8.0 21.9 +-
l 044 65 3.5 21.6 +-
.6 ;
3.2 t10 NET DATA 045 182 4.2 24.2 +-
.7 l 3.6 N0 t1ET DATA 047 298 4.5 23.7 +-
.7 l 3.6 N0 t1ET DATA 048 13 14.
21.3 +-
.6 l 3.2 NO HET DATA 049 207 19.
MISSING OR DAMAGED DOSIMETER ti0 TRANSIT DOSE CALCULATED (TLD CONTROLS MISSING OR OTHERWISE t10T COMPLETE) l
FT. CALHOUN FOR THE PERIOD 821221-830422 TLD DIRECT RADIATICN ENVIRONMENTAL MONITORING i
RZIfluTH (deg.)
AVER. EXPOSURE PATE
- IN GROUP (mP/Std.Otr.) +-Std.Dev.
348.75-ll.25 (N) 16.7 +
.4 2
11.25-33.75 (NNE) 15.9 +
.7 3
33.75-56.25 (NE) 16.5 +
.7 2
56.25-78.75 (ENE) 17.D +
.9 4
78.75-10l.25 (E) 15.5 +.6 2
101.25-123.75(ESE) 17.D +
.8 2
123.75-146.25(SE) 17.2 +- 1.4 3
145.25-168.75(55E) 15.9 +- 2.5 3
168.75-191.25(5) 17.3 +- 1.2 4
19 t. 2 5-2 l 3. 7 5 ( 5 5 H.'
17.5 +
.2 2
213.75-236.25fSN) 17.1 4-
.5 2
236.25-258.75tH5W) 18.0 +- 0.0 1
258 75-281.25(H) 18.2 +
.3 2
28l.25-303.75(WNH) 17.2 +
.2 2
303.75-326.25(NN) 17.6 +
.7 2
326.25-348.75(NNN) 15.8 +
.4 2
l OISTANCE(mi) FR0ft THE PEACTOP!
RVER.EXPOSUPE RATE
+ IN GROUP (mP/5td.0tr.) +-Sid.Dev.
0-2 17.1 +- 1.0 8
2-5 16.5 +- 1.3 19
>5 17.2 +- 1.0 11 UPHIND CONTROL ORTA 16.4 +- 1.2 2
l i
I
./
FT. ST. VRAIN TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821221-830412 113 DAYS FIELD TIME 94 DAYS HRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (raR) raR/St d. 0t r.
(dea.)
( ra i. )
+- Rdra; Tot.
+- Rdra; Tot.
001 8
0.8 37.7 +-
1.1 ;
5.6 33.3 +-
1.3 ;
6.1 002 2
3.3 37.2 +-
1.1 ;
5.6 32.9 +-
1.2 l 6.0
~
003 29 2.6 38.3 +-
1.1 ;
5.7 33.9 +-
1.3 l 6.1 004 17 5.4 40.1 +-
1.2 l 6.0 35.6 +-
1.3 l 6.4 005 54 2.1 36.1 +-
1.1 l 5.4 31.8 +-
1.2 l 5.9 006 48 4.8 36.7 +-
1.1 l 5.5 32.4 +-
1.2 ;
5.9 007 76 2.6 38.2 +-
1.1 l 5.7 33.8 +-
1.3 l 6.1 008 58 4.2 MISSING OR DRl1 AGED DOSIMETER 009 100 1.5 39.2 +-
1.2 ;
5.9 34.8 +-
1.3 ;
6.3 010 87 4.5 35.1 +-
1.11 5.3 30.8 +-
1.2 l 5.7 011 118 1.6 41.6 +-
1.2 l 6.2 37.0 +-
1.3 ;
6.6 012 104 3.0 37.9 +-
1.1 l 5.7 33.5 +-
1.3 l 6.1 013 143 1.6 32.9 +-
1.0 l 4.9 28.7 +-
1.1 ;
5.5 014 128 4.5 37.3 +-
1.1 l 5.6 32.9 +-
1.2 l 6.0 015 168 2.3 34.6 +-
1.0 ;
5.2 30.4 +-
1.2 ;
5.7 1.2 '
6.0 016 148 4.6 37.2 +-
1.1 ;
5.6 32.8 +-
1.3 ;;
6.5 017 182 0.8 41.5 +-
1.2 ;
6.2 36.9 +-
018 175 4.8 36.6 +-
1.1 l 5.5 32.3 +-
1.2 l 5.9 019 210 0.9 MISSING OR DRfiAGED DOSIMETER 020 20n
?.9 41.5 +-
1.2 ;
6.2 37.0 +-
1.3 ;
6.6 021 234
- 1. ::
38.3 +-
1.1 l 5.7 33.9 +-
1.3 l 6.1 022 216 3.3 33.0 +-
1.0 l 5.0 28.8 +-
1.1 l 5.5 023 254 2.5 34.2 +-
1.0 l 5.1 30.0 +-
1.2 l 5.6 024 244 3.S 35.2 +-
1.1 ;
5.3 30.9 +-
1.2 l 5.7 025 278 1.5 34.6 +-
1.0 ';
5.2 30.3 +-
1.2 ;
5.7 026 263 5.4 33.3 +-
1.0 ;
5.0 29.1 +-
1.1 ;
5.5 02i 297 1.7 36.4 +-
1.1 l 5.5 32.0 +-
1.2 ;
5.9 02A 084 5.6 27.5 +-
.8 ;
4.1 23.5 +-
1.0 ;
4.8 029 317 0.9 37.8 +-
1.1 ;
5.7 33.4 +-
1.3 l 6.1 030 305 4.2 36.2 +-
1.1 !
5.4 31.9 +-
1.2 l 5.9 a
VV.i +_
1.i e e. ;1 oo.I. +_
i.d D.4 oo 4
- n. o t ooo 4.T d
VV 1
9 A
V JVV 1
q 03?
22n 5.0 35.0 +-
1.0 l 5.?
00.7 +-
1.2 ;
5.7 033 267 6.5 39.9 +-
1.2 l 6.0 35.4 +-
1.3 l 6.3 034 130 3.7 34.1 +-
1.0 l 5.1 29.9 +-
1.2 l 5.6 035 270 0.1 34.2 +-
1.0 '.
5.1 29.9 +-
1.2 l 5.6 e.o 04.o 40 6 D.3 n.oo 04e
- J.1; q.nU.,i +_
i.o g d V V
V -
4 V q wV V4d w
a 039 10 6.0 38.5 +-
1.2 ;
5.8 34.1 +-
1.3 l 6.2 040 63 6.0 34.2 +-
1.0 ;
5.1 30.0 +-
1.2 l 5.6 041 165 12.
40.4 +-
1.2 l 6.1 35.9 +-
1.3 l 6.4 049 048 13.
45.2 +-
1.4 ';
6.3 40.5 +-
1.4 l 7.0 1
045 198 11.
38.0 +-
1.1 ;
5.7 33.6 +-
1.3 l 6.1 046 39 16.
36.1 +-
1.1 l 5.4 31.8 +-
1.2 ;
5.8 047 357 17.
31.2 +-
.9 l 4.7 27.1 +-
1.1 ;
5.2 048 171 18.
37.8 +-
1.1 l 5.7 33.4 +-
1.3 ;
6.1
- n. 4. 9 ocg
- n.. s-ao.ed +_
i.o a e.a ed.n. +_
1.o b.o TRANSIT DOSE =
2.9
+-
.7 ; 2.8
'1 V
s V
V y V
vv vs w
N.
FT. ST. VRAlli F0F THE PERIOD 821221-830412 l
TLD DIRECT RADIATI0t1 EtiVIR0fiMENTAL MONITORItiG 1
RZIfluTH (dag.)
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
i 348.75-1l.25 (N) 33.4 +-.5 3
11.25-33.75 (NNE) 34.7 +- 1.2 2
33.75-56.25 (NE) 32.0 +
.3 3
56.25-78.75 (ENE) 3l.9 +- 2.7 2
l 78.75-10l.25 (E) 32.8 +- 2.8 2
101.25-123.75(ESE) 35.2 +- 2.5 2
123,75-146.25(SE) 3 0. 5 +- 2.2 3
14 6.25-166. 75 ( 55E )
33.0 +- 2.8 3
l 168.75-191.25(5) 34.5 +- 3.3 2
19l.25-2l3.75tSSH) 35.3 4-2.4 2
213.75-236.25(SW' 31.3 +- 3.6 2
236.25-258.75(WSH) 33.8 +- 5.8 3
258.75-281. 25 ( H )
3l.2 +- 2.9 4
28 l.25-303.75 (WNW) 27.8 +- E.O 2
i 303.75-326.25 (id H )
32.6 t-1.0 2
326.25-348.75(NNH) 32.9 +- 1.9 3
DISTANCE (mi) FR0t1 THE REACTOR NET AVER. EXPOSURE RATE
+ I N GR OUP (mR/5td.Qtr.) + -5t d. De v.
i 0-2 33.1 +- 2.7 11 2-5 32.0 +- 1.9 1B
>5 33.1 +- 4.4 11 UPHIND CONTROL DATA 3l.9 +- 4.2 3
GIllllA TLD DIPECT RADIATI0ti ENVIR0tlMENTAL N0!11TORIllG FORTH$ PERIOD 821221-830425 126 DAYS FIELD TIME 106 DAYS tlRC LOCATION GROSS HET EXPOSURE RATE STATI0l! AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(deg.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 95-1.7 17.7 +-
.5 ;
2.6 13.3 + '
.6 ;
2.9 002 108 1.1 17.2 +-
.5 l 2.6 12.9 +-
.6 ;
2.8 003 142 1.7 17.7 +-
.5 l 2.6 13.3 +-
.6 l 2.9 004 154 1.5 MISSING OR DAMAGED DOSIMETER 005 174 1.4 18.1 +-
.5 ;
2.7 13.7 +-
.6 ;
2.9 n.ng 919 1.
1 o +-
.s e o.7 t o..s. + -
.o, o. o, e
.v
- i 007 244
.9 16.0 +-
.5 l 2.4 11.9 +-
.6 l 2.7 008 230
.6 19.5 +-
.6 ;
2.9 14.9 +-
.6 l 3.1 010 266 1.5 18.5 +-
.6 l 2.3 14.0 +-
.6 l 3.0 011 264 4.6 19.2 +-
.6 l 2.9 14.7 +-
.6 l 3.0 l
o. :s 11..* +-
- 6. '
?.4
- n. i. o
- 94. e.I
.;. s 1 -[. 7 +-
.d p
e.
V w
s 1
w w
013 235 4.2 19.2 +-
.6 ;
2.9 14.? +-
.6 l 3.0 014 200 3.8 16.3 +-
.5 ;
2.4 12.2 +-
.6 l 2.8 e,
o.i o
4 e
n4e
.t,r v o.4 to.o +-
.c, o.a is..o +-
y e
iu s
v e
016 160 3.7 16.4 +-
.5 l 2.5 12.2 +-
.6 l 2.8 017 134 3.5 17.3 +-
.5 l 2.6 13.0 +-
.6 l 2.8 018 115 4.3 20.0 +-
.6 l 3.0 15.3 +-
.7 ;
3.1 019 88 4
18.6 +-
.6 l 2.9 14,.,1 + -
.6 l 3.0 d.J 4.) i~
.D e,
e, e..
3-
~
.ed
.D.ed cm D.1 ba d 's I
d.o 021 123 7.6 17.2 +-
.5 l 2.6 12.9 +-
.6 ;
2.8 022 105 12.
18.6 +-
.6 l 2.8 14.1 +-
.6 ;
3.0 i
023 151 11.
16.3 +-
.5 l
- 2. 4 12.2 +-
.6 ;
2.8 024 212 13.
21.8 +-
.7 l 3.3 16.9 +-
.7 l 3.3 025 223 13.
18.9 +-
.6 l 2.8 14.4 t-
.6 l 3.0 o
e n
no; 949 is.
o n. 4. +. -
.ge s.1 te.g +-
.c, a.o c
wn.
V s 027 254 14.
19.8 +-
.6 l 3.0 15.2 +-
.c ;
3.1 028 234 6.9 18.9 +-
.6 l 2.8 14.4 +-
.6 l 3.0 029 185
.3 18.9 +-
.6';
2.3 14.4 +-
.6 l 3.0 030 264 14 17.4 +-
.5 l 2.6 13.1 +-
.6 ;
2.9 TRAtlSIT DOSE =
1.9
+-
.o ; z.1 1
I
)
GIllNA FOR THE PERIOD 821221-830425 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIrluTH (dag. )
NET RVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std Dev.
348.75-ll.25 LN)
NO DRTA+-NO DATR 0
11.25-33.75 (NNE)
No DRTA+-NO DATR 0
33.75-56.25 (NE)
NO DATA +-NO DATR 0
56.25-78.75 (ENE)
NO DATA +-NO DATR 0
78.75-10l.25 (E) 13.3 +
.9 3
10l.25-123.75(ESE) 13.8 +- 1.1 4
123.75-146.25(SE) 13.2 +
.2 2
14 5.25-158. 75 ( 55 E )
12.2 4-
.D 2
158.75-191.25(5) 14.1 +-.8 3
19t.25-2l3.75(55N) 14.2 +- 2.4 3
213.75-236.25(SH) 14.5 +
.2 4
236.25-250.75(W5W) 12.6 +- 1.0 2
258.75-291.25(W) 14.3 +
.5 2
29 l.25-303.75 (WNW)
NO DRTAt-N0 DATR 0
303.75-326.25(NN)
NO DATAt-NO DATR 0
326,25-348.75(NNN)
NO DATA +-NO DATA 0
OISTANCE(mi) FR0t1 THE REACTOP NET RVER. EXPOSURE RATE
+ IN GROUP (mR/5td.Qtr.) + -5t d. De v.
l 2-2 13.6 +
.9
-9 i
2-5 13.9 +- 1.2 9
>5 13.9 +- 1.6 7
UPHIND CONTROL ORTA 14.6 +- 1.3 3
GRAllD GULF TLD DIRECT RADI ATI0t1 Ell';/IR0tiMEt1TAL MONITORIliG FOR THE PERIOD 821221-830411 112 DAYS FIELD TIME 91 DAYS l1RC LOCATI0ti GR05S t1ET EXPOSURE RATE STATI0t1 AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.
(dea.)
( m i. '>
+- Rda; Tot.
+- Rdm; Tot.
002 351 1.6 13.2 +-
.4 ;
2.0 11.7 + '
.5 ;
2.3 003 20 1.5 15.5 +-
.5 ;
2.3 14.0 +-
.5 l 2.6 004 51 2.3 14.1 +-
.4 l 2.1 12.6 +-
.5 l 2.4 005 68 2.7 16.5 +-
.5 l 2.5 14.9 +-
.6 ;
2.7 006 47 4.1 14.0 +-
.4 l 2.1 12.5 +-
.5 ;
2.4 007 68 4.9 16.6 +-
.5 l 2.5 15.0 +-
.6 l 2.8 008 91 3.2 16.5 +-
.5 l 2.5 15.0 +-
.6 l 2.7 009 81 1.0 14.7 +-
.4 l 2.2 13.2 +-
.5';
2.5 010 109 0.6 UISSING OR DAMAGED DOSIMETER 011 139 0.8 17.0 +-
. 5 -;
2.5 15.4 +-
.6 ;
2.8 012 155 1.6 15.2 +-
.5 l 2.3 13.7 +-
.5~;
2.6 013 207 1.9 15.6 +-
.5 l
- 2. 3 14.1 +-
.5 l 2.6 014 247 1.5 11.7 +-
.4 ;
1.3 10.3 +-
.4 l 2.1 015 130 4.2 15.3 +-
.5 l 2.3 13.8 +-
.5 l 2.6 016 122 4.8 15.7 +-
.5 l 2.4 14.2 +-
.5 l 2.6 e
o-e e
,3 to.D i
.ed g idd
- 0 15'.1 +_
.d q
c.J
- n. t,
c.D AV
.I J.s c'.1 I '. c'
+-
. "s ',
'. 4' 14,*7 4'. s; l 'v. 7,
+-
0.10 c
c v
019 224 6.8 15.3 +-
.5 l 2.3 13.8 +-
.5 l 2.6 020 172 3.6 13.9 +-
.4 l 2.1 12.4 +-
.5 l 2.4 021 291 12.
14.2 +-
.4 l 2.1 12.7 +-
.5 l 2.4 022 332 8.0 16.5 +-
.5 ;
2.5 15.0 +-
.6 l 2.7
~
023 310 7.9 7.5 +-
.2 l 1.1 6.1 +-
.4 ;
1.7 024 281 7.0 13.8 +-
.4 l 2.1 12.3 t-
.5 l 2.4 e
- p. _ s.
_941
- 4.. :.
14.
7, +-
.,4 9. _>
10 9 +-
.e o.ea a
a 026 248 9.5 14.6 +-
.4 l 2.2 13.1 +-
.5,;
2.5 1
6._7,
_? q o to.
1.1.. e +-
4
- 9.. a.
19.a.,_
.e 9.4 e
a,
029 090 0.9 14.8 +-
.4 l 2.2 13.3 +-
.5*
2.5 030 67 51 12.0 +-
.4 l 1.3 10.5 +-
.5 l 2.2 031 67 51 11.8 +-
.4 l 1.3 10.3 t-
.5 ;
2.1 032 67 51 11.2 +-
.3';
1.t v.8 +-
.4 l 2.1 4.E
,15.3 +-
.o ;
z.3 13.8 +-
.5 l 2.6 03j,I,t D_j06 In.nti 0t =
1.:
t-i.s l
GRR!1D GULF FOR THE PERIOD 821221-S30411 TLD DIRECT RADIATION ENVIRD4ME!FAL MONITORING RZIr1UTH (dag.)
NET AVER. EXPO 5URE RATE 4 IN GROUP (mP/Std.Qtr.) t-Std.Dev.
348.75-ll.25 (N) ll.7 +- 0.0 1
11.25-33.75 (NNE) 14.0 +- 0.0 1
33.75-56.25 (NE) 12.5 +
.1 2
56.25-78.75 (ENE) 15.D +-.1 2
78.75-10l.25 (E) 13.8 +- 1.0 3
10l.25-123.75(E3Ei 14.2 +- 0.0 1
123.75-146.25(SE) 14.3 +- 1.0 3
14 5.25-159. 75 ( 55E s 12.2 4-0.0 1
150.75-191.25(5) 13.D +-.9 2
19 l. 25-2 l3.75 ( 55N )
13.9 4-
.2 2
213. 75 -23 6. 25 ( S N 's 13.8 +- 0.0 1
236.25-258.75(W5H)
Il.B +- 1_4 3
258.75-281.25(W) 12.3 +- 0.0 1
28l.25-303.75(UNU) 12.9 +
.3 2
303.75-328.25(NH';
6.1 +- 0.0 1
326.25-348.75(HNH) 15.D +- 0.0 1
DISTANCE (mi) FR0t1 THE PEACTOP NET RVER. EXPOSURE RATE
+ IN GROUP (nR/5td.0tr.)
+-5t d. De v.
0-2 13.2 +- 1.6 8
2-5 13.8 +- 1.1 11 i
>5 12.3 +- 2.7 8
UPHIND CONTROL ORTA 10.2 +
.4 3
1 1
HRDDAM NECK TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821222-830422 122 DAYS FIELD TIME 98 DAYS NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rda; Tot.
+- Rdm; Tot.
002 17-2.6 15.1 +-
.5 ;
2.3 12.3 + '
.5 ;
2.3 003 45 1.9 13.1 t-
.4 ;
2.0 10.4 +-
.4 l 2.1 004 6<
z.?
14.7 t-
.4 l 2.2 11.9 +-
.5';
2.3 005 93 1.6 13.1 t-
.4 l 2.0 10.4 +-
.4 l 2.1 006 115 2.3 12.5 t-
.4 ;
1.9 9.9 +-
.4 ;
2.0 007 143 1.9 14.1 +-
.4 l 2.1 11.3 +-
.5 l 2.2 008 165
.?
MISSING OR DAMAGED DOSIMETER
~
009 174 1.3 14.9 +-
.4 ;
2.2 12.1 +-
.5 ;
2.3 010 195
.7 13.7 +-
.4 l 2.0 11.0 +-
.5 l 2.2 012 241
.8 MISSING OR DAMAGED DOSIMETER
~
01.1
?63
.8 13.5 t-
.4 ;
2.0 10.8 +-
.4 ;
2.2 014 290 1.9 14.9 +-
.4 l 2.2 12.1 +-
.5 l 2.3 015 311 1.5 13.2 +-
.4 l 2.0 10.6 +-
.4 ;
2.1 016 341 1.2 14.2 +-
.4 ;
2.1 11.5 +-
.5 l 2.2 a
- a. t.
.a o_
is.s_,-
.s,
?.0 1?.?i +-
.c o.4 2
c t4
+-
.4 9.1 11.4 +-
5,
.4.9 o.?
- n. t R.
9 := 0 0.=
019 269 3
12.5 +-
.4 l 1.9 9.9 +-
.4 ;
2.0 020 66 30 13.9 +-
.4 l 2.1 11.2 +-
.5 l 2.2 021 91 2.3 14.6 +-
.4 l 2.2 11.8 +-
.5 ;
2.3 022 112 3.2 14.1 +-
.4 t 2.1 11.4 +-
.5 ;
2.2 023 137 2.9 13.1 +-
.4 l 2.0 10.4 +-
.4 l 2.1 02:
155 7.1 16.9 +-
.5 l 2.5 13.9 +-
.5 ;
2.6 025 175 5.7 13.5 +-
.4 ;
2.0 10.8 +-
.4 ;
2.2 026 196 2.5 13.2 +-
.4 ;
2.0 10.5 t-
.4 ;
2.1 027 225 1.1 14.3 +-
.4 l 2.1 11.5 +-
.5 l 2,2 0_rw.
250
- 3.,. 5
- 12. 7, +-
.4 l
,1. 9, 10.1 +-
.4 ;
2 1, 28 te o*U eo 44.t t-
.c, o.-
el.1 +-
.c ;
4. t.
030 286 3.2 13.8 +-
.4 ;
2.1 11.1 +-
.5 l 2.2 031 322 2.7 13.8 t-
.4 l 2.1 11.1 +-
.5 ;
2.2 032 327 2.9 16.1 +-
.5 l 2.4 13.2 +-
.5 ;
2.5 033 359 6.4 17.9 +-
.5~;
2.7 14.9 +-
.6 ;
2.7 035 54 10.
14.5 +-
.4 l 2.2 11.7 +-
.5 ;
2.3 036 72 8.8 16.2 +-
.5 l 2.4 13.3 +-
.5 l 2.5 037 149 6.8 13.2 +-
.4 l 2.0 10.5 +-
.4 ;
2.1 038 158 5.9 13.1 +-
.4 ;
2.0 10.4 +-
.4 ;
2.1 039 267 8.8 13.8 +-
.4 ;
2.1 11.1 +-
.5 j 2.2 040 303 9.1 17.3 +-
.5 ;
2.6 14.3 +-
.5 ;
2.6 041 313 9.6 14.7 +-
.4 ;
2.2 11.9 +-
.5 l 2.3 042 320 13.
14.6 +-
.4 l 2.2 11.8 +-
.5 l 2.3 043 324 18 13.9 +-
.4 l 2.1 11.2 +-
.5 ;
2.2 044 328 15 14.4 +-
.4 ;
2.2 11.7 +-
.5 ;
2.3 l
045 343 18 14.7 +-
.4 ;
2.2 11.9 +-
.5 ;
2.3 046 144 5
14.3 +-
.4 ;
2.1 11.6 +-
.5 ;
2.3 047 330 20 14.3 +-
.4 ;
2.1 11.5 +-
.5 ;
2.2 048 330 20 16.9 +-
.5 ;
2.5 13.9 +-
.5 l 2.6 049 340 20 15.9 +-
.5 l 2.4
.13.0 +-
.5 ;
2.4
.3 ; 1.2
~
TRANSIT DOSE =
1.7
+-
HADDAf1 NECK FOR THE PERIOD 821222-830422 TLD DIRECT RADIATI0t1 EllVIR0tir1ElliAL f10NITORItiG RZIt1U TH (dag.)
f4ET AVER. EXPO 5URE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-ll.25 (N) 13.8 +- 1.6 2
11.25-33.75 (NNE) 12.3 +- 0.0 1
33.75-56.25
( t4 E )
ll.1 +
.9 2
56.25-78.75 (ENE) 12.1 +- 1.1 3
78.7F-10l.25 'El 11.1 +- 1.0 2
10l.25-123.75(ESE) 10.6 +- 1.1 2
123,75-146.25(SE) 11.1 +
.6 3
14 6.25-166.75 ( 55 E )
11.5 +- 2.0 3
166.75-191.25(5) 11.1 +
.9 2
191.25-213.75(55N) 10.7 +
.3 2
213.75-236.25(SW) ll.5 +
.1 2
236.25-258.75(W5W) 10.1 +- 2.0 1
258.75-281.25(W) 10.6 +
.B 3
281.25-303.75(WNW) 12.5 +- 1.6 3
333.75-328.25(NH) 11.3 +
.6 5
326.25-348.75(NNN) 13.9 +- 4.1 5
DISTAt4CE( m i ) FR0t1 THE REACTOR NET RVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.)
+-5t d. De v.
B-2 11.2 +
.6 19 1
2-5 11.3 +- 1.0 16
>5 12.7 +- 2.7 15 UPNIND CONTROL DRTA 12.B +- 1.2 3
HATCH TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821221-830425 126 DAYS FIELD TIME 95 DAYS NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(m1.)
+- Rdm; Tot.
+- Rda; Tot.
1-iD.o +-
99 o.4 11.o +-'
7 o.4
- 0. 0.1
- 1. 4. 0 o g.
w s
w V
I q
W w
w
^ 5 4.-
77 14.
4.- +-
.4.
'?. _?
1A. 1 +-
. 'I,'
'.3 A. A. w?
o as w
4 e
n
.n o.
t.d o.o +-
.c o.c U 45 Se4 4.e
--eV WV4 s
l.
- e..+-
.4 v
004 336 2.9 19.8 t-
.6 l 3.0 14.7 +-
.8 l 3.8 e
4 4
e
?.?
o. R. +-
7 o.o
- a. n. s ooo 4.c 14.D +-
vbs
.4 q
w s
I q
V w v
w 006 297 5.6 15.8 +-
.5 l 2.4 10.9 +-
.7 l 3.4 e
o e
- a. n. I 94
- 14. 7 +-
4 o.w o.o +-
. 'c o.o w4 w.
v a
I g
w s
g V V 008 49 2.0 14.8 +-
.4 l 2.2 10.0 +-
.7 l 3.3 009 49/
10.
15.9 +-
. 5 -l 2.4 11.1 +-
.7 l 3.4 010 28 4.8 16.2 +-
.5 l 2.4 11.3 +-
.7 l 3.4 011 67 5.0 21.1 +-
.6 l 3.2 15.9 +-
.8 l 3.9 012 50 5.1 18.7 +-
.6 l 2.8 13.7 +-
.8 l 3.6 013 353 2.0 15.2 +-
.5 l 2.3 10.3 +-
.7 ;
3.3 014 341 1.6 15.8 +-
.5';
2.4 11.0 +-
.7 ;
3.4 015 147 10.
14.0 +-
.4 l 2.1 9.3 +-
.7 l 3.2 14 d
e e
o. _o o.c +-
7 q.o a.t c 909 Lq.a
. 4. 4. + -
.4 s
_Vw s
w s
w 017 205 1.6 19.7 +-
.6 l 3.0 14.7 +-
.8 l 3.8 o
U.7 +-
7 o.1 A.IR 1G?
- 4.. ?
10.*
t-4
?.7 f
i I
g J
v
<w s V g
w s
4 5 A
i Q q 9
i a 4 et-4Q j o*r 4n 4 -
jn0.0 t-
.4
- 1. :*.s V.o t-
.c, o.
i 020 165 4.6 14.1 +-
.4 l 2.1 9.3 +-
.7 l 3.2 021 135 4.4
- 20. 5. +-
. 6. l.
3.1 15.4. +-
.8 l 38 Uzz
- 120, 4.1 20.9 +-
.D 3.1 15.0 +-
.8 ;
4
.s. 9 4
e
- n. o :.
i n. i
- 2.. 7 14. a. ++ -
- 4..
o9-in..i +-
7 o. q.
ww i
g w.
I q
J e
n ? ?.
lo?
li.
l4.a. +-
.4 g
d d *
?.1 Qs.o +-
7 o.o w
I q
V w
s-
-v v
w 7 i Uts 114 1 *:
tC
.C S.S 180.7 +-
.c
- C 4
5.Q it.
is.t t-s c 3 c
eV 026 142 1.8 15.1 +-
.5 ;
2.3 10.3 +-
.7 l 3.3 027 157 2:2 19.3 +-
.6 l 2.9 14.3 +-
.8 l 3.7 028 171 0.9 19.6 +-
.6 ;
2.9 14.5 +-
.8 l 3.7 029 253 1.0 19.8 +-
.6 l 3.0 14.7 +-
.8 l 3.8 030 270 1.0 19.1 +-
.6 i 2.9 14.1 +-
.8 ;
- 3. 7, I
ami oco it to q +-
ce 6
'.p eY !5l4 655 5$5 4l$
15l5+-
'5 !
$la 11.I+-
14 o +-
o 4
nio 94o
- 4.. a 14.c +-
.4 e o. w?
o.o +-
.[
o.o 4
-e
-J w
V s
v g
w s
V g
V w 034 216 4.1 13.5 +-
. 4 ~;
2.0 8.8 +-
.7 l 3.2 035 234 11.
20.5 +-
.6 l 3.1 15.4 +-
.8 ;
3.8 w
'?
1 4. 4' +-
."c '
- n. e.c 1 p..o i n..
14..? +-
.4
~
w.
V.?
o
+
037 177 10.
13.4 +-
.4 ;
2.0 8.6 +-
.7,;
3.1 s
w l
038 323 12.
15.9 +-
.5 ;
2.4 11.0 +-
.7 l 3.4 A..?.mQ
??1 l 'v.
1 "s. R. + -
5 ',
?
w. 4' 11.A. +-
7
- 1. 4 3.4 17.2 +-
.9,;
4.0 v-040 323 12.
22.4 +-
.7 l
~
TRANSIT DOSE =
4.2
+-
.6 ; 2.6
t HATCH FOR THE PERIOD 821221-330425 TLD DIRECT RADI ATION EtWIR0 tit 1 ENTAL l10!1ITORING RZIt1UTH (dag.)
NET AVER. EXPOSURE RATE
- IN GPOUP (mR/Std.Qtr.) t-Std.Dev.
348.75-ll.25 (N) 9.7 +
.B 3
11.25-33.75 (NNE) 10.8 +- 1.0 2
33.75-56.25 (NE) 11.8 +- 1.9 3
56.25-78.75 (ENE) 15.9 +- 0.0 1
78.75-10l.25 (E)
NO DRTA+-NO DATR 0
10l.25-123.75(ESE)
IL.5 +- 3.0 4
123.75-146.25(SE) 12.8 +- 3.6 2
14 6.25-168. 75 ( 55E )
10.9 4-2.9 3
168.75-191.25(5) 10.2 4-2.9 4
19L.25-2l3.75(55H) ll.7 4-4.2 2
213.75-236.25(SH) 11.3 +- 3.6 3
236.25-258.75(W5W) 12.3 +- 3.4 2
258.75-201.25(W) 12.5 +- 2.1 2
28 l.25-303.75 ( HNH) 12.6 +- 2.3 2
303.75-326.25(NH)
S.8 t-0.0 1
326.25-348.75(NNN) 12.3 +- 2.1 3
I DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP (mR/5td.Qtr.) +-5t d. De v.
B-2 12.3 +- 2.2 19 2-5 ll.4 +- 2.8 16 h
>5 10.9 +- 2.0 11 UPNIND CONTROL ORTA 13.1 +- 3.6 3
It1DI At1 POIt1T TLD DIRECT RADIATI0ti EtiVIR0tiMEt1TAL MONITORIt4G FOR THE PERIOD 821221-830422 123 DAYS FIELD TIME 91 DAYS tlRC LOCATI0tl GROSS t1ET EXPOSURE RATE STATI0t1 AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 52' 1.4 20.3 +-
.6 ;
3.0 16.2 + '
.8 ;
3.7 002 53 1
20.7 +-
.6 i 3.1 16.6 +-
.8 ;
3.7 003 61 1.5 MISSIt4G OR DAMAGED DOSIMETER
~
004 89 1.2 20.3 +-
.6 ;
3.0 16.3 +-
.8 ;
3.7 005 107
.9 19.6 +-
.6 ;
2.9 15.6 +-
.8 ;
3.6 006 90
.5 19.5 +-
.6 ;
2.9 15.5 +-
.8-3.6 007 133
.5 17.5 +-
.5 l 2.6 13.4 +-
.7 ;
3.3 008 158
.8 19.2 +-
.6 l 2.9 15.2 +-
.7 l 3.5 009 188 1.2 19.1 +-
.6 l 2.9 15.1 +-
.7 i 3.5 010 206
.9 18.4 +-
.6 l 2.8 14.4 +-
.7 ;
3.4 011 170 1.1 t11SSIllG OR DAMAGED DOSIMETER 012 155 2.3 13.1 +-
.4 ;
2.0 9.1 +-
.6 ;
2.9 013 136 3.2 19.5 +-
.6 l 2.9 15.4 +-
.8 l 3.6 014 107 3.1 17.2 +-
.5 ;
2.6 13.2 +-
.7 ;
3.3
.7 3.4 015 94 3.8 17.9 +-
.5 l 2.7 13.8 +-
.8 ;;
3.6 016 140' "7
19.7 +-
.6 l 3.0 15.7 +-
017 148 6. =-
C'0.5 +-
.6 i 3.1 16.4 +-
.8 ;
3.7 018 147 9.1 19.8 +-
.6-3.0 15.8 +-
.8 ;
3.6 019 137 11.
21.9 +-
.7 ;
3.3 17.8 +-
.8 ;
3.9 020 129 11.
20.8 +-
.6 ;
3.1 16.8 +-
.8 l 3.7 021 84 8.7 20.0 +-
.6 t 3.0 16.0 +-
.8 l 3.6 022 74 7.5 19.6 +-
.6-2.9 15.6 +-
.8 ;
3.6 023 5
92 MISSI!1GORDAf1RGEDDOSIMETER 024 5
92 19.7 +-
.6 ;
3.0 15.7 +-
.8 ;
3.6 025 65 4.1 17.5 +-
.5 ;
2.6 13.4 +-
.7 ;
3.3 3.0 16.1 +-
.8 ;
3.7
.6' 026 40 4
20.2 +-
.6 ;
2.9 15.4 +-
.3 ;
3.6 027 25 5.3 19.4 +-
.6 ;;
2.8 14.8 +-
.7 ;
3.5 028 24 2.9 18.9 +-
029 22 2.1 19.5 +-
.6 ;
2.9 15.4 +-
.8 ;
3.6 030 8
1.9 22.1 +-
.7 i 3.3 18.0 +-
.8 ;
3.9 031 356 5
19.5 +-
.6 ;
2.9 15.5 +-
.8 i 3.6 032 330 3.7 20.0 +-
.6 ;
3.0 16.0 +-
.8 ;
3.6 033 338 4.7 20.7 +-
.6 ;
3.1 16.7 +-
.8 ;
3.7 034 354 7
20.7 +-
.6 ;
3.1 16.7 +-
.8 ;
3.7 035 297 4.4 20.1 +-
.6 l 3.0 16.0 +-
.8 ;
3.6 036 309 3.6 14.2 +-
.4 t 2.1 10.2 +-
.6 ;
3.0 037 350 1.1 18.2 +-
.5 ;
2.7 14.2 +-
.7 ;
3.4 038 337 0
0'0.7 +-
.6 ;
3.1 16.6 +-
.8 ;
3.7 039 315 1
17.8 +-
.5 ;
2.7 13.8 +-
.7 ;
3.4 040 294 1.1 18.3 +-
.5 ;
2.7 14.3 +-
.7 ;
3.4 041 274 1.1 21.0 +-
.6 ;
3.2 17.0 +-
.8 ;
3.8 040' 0'48 1.5 MISSIt1G OR DAMAGED DOSIMETER 043 263 2.8 22.7 +-
.7 ;
3.4 18.6 +-
.8 ;
4.0 044 5
92.
19.6 +-
.6 ;
2.9 15.5 +-
.8 ;
3.6 045 227 2.4 20.1 +-
.6 ;
3.0 16.0 +-
.8 ;
3.6 046 209 3.2 19.2 +-
.6 ;
2.9 15.1.+-
.7 ;
3.5 047 218 5.3 18.5 +-
.6 ;
2.8 14.5 +-
.7 ;
3.5 048 201 4.6 18.5 +-
.6 ;
2.8 14.4 +-
.7 ;
3.4 049 187 5.2 19.0 +-
.6 ;
2.8 14.9 +-
.7 ;
3.5 050 171 7.1 18.7 +-
.6 ;
2.8 14.7 +-
.7 ;
3.5 TRf4NSIT DOSE =
3.9
+-
.5 ; 2.1
INDIAN POINT FOR THE PERIOD 821221-830422 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIt1UTH (dag.)
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Otr.) t-Std.Dev.
348.75-ll.25 (N) 15.9 +- 1.3 6
11.25-33.75 (NNE) 15.2 +
.3 3
33.75-56.25 (NE) 16.3 +
.3 3
56.25-78.75 (ENE) 14.5 +- 1.5 2
78.75-101.25 (E) 15.4 +- 1.1 4
10l.25-123.75(ESE) 14.4 +- 1.7 2
123.75-146.25(SE) 15.8 +- 1.6 5
14 6.25-168. 75 ( 55 E )
14.1 +- 3.4 4
168.75-191.25(5) 14.9 +
.2 3
19L.25-2L3.75(55H) 14.7 +
.4 3
213.75-236.25(SW) 15.3 +- 1.1 2
238.25-259.75(W5W)
NO DRTAt-NO DATR 2
258.75-281.25(W) 17.8 +- 1.2 2
291.25-303.75(WNW) 15.2 +- 1.2 2
303,75-328.25(NN) 12.0 +- 2.8 2
326.25-348.75(NNW) 16.4 +
.4 3
DISTANCE (mi) FR0t1 THE REACTOR NET RVER. EXPOSURE RATE 4 IN GROUP
.j
( mR/5t d. Q t c. )
+-St d. De v.
B-2 15.5 +- 1.3 15 2-5 14.7 +- 2.3 17
>5 15.B +
.9 14 UPNIND CONTROL ORTA NO DATA NO DATR
1 KEUAUNEE/PT. BEACH TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821221-830414 115 DAYS FIELD TIME 93 DAYS HRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdro; Tot.
001 189 8.1 21.8 +-
.7 ;
3.3 19.7 +-'
.9 ;
4.1
- n. a. o lo.r
.n
>1.o +-
.D 5,
o.?
i c.-. w- +-
.o e,
4.1 L
w I
V V
V 003 163 4.9 20.6 +-
.6 l 3.1 18.6 +-
.8 l 4.0
- n. n. a.
1 o.9 e.2 09..e.
t-7 o. a.
on. 9 +-
.o e,
4.?
e s,
a.
w w
a av v w ww 005 210 3.2 19.9 +-
.6 ;
3.0 17.9 +-
.8 l 3.9
- a. n.
??o o.7 0 9. b' +-
7 6,
o.4 on. 5. +-
.c, 4. 0' i
v w
w w
www v i ww i
'4w v.7 on..o +-
.ci o. f.j 10.ao +-
.o
. f.t 40 f.i f.j 7, c
s c
a.
v,
a v
v,
On 1 o O?.6 +.-
7
?4 O f.1. ea +-
4, 4'. ?
i 4
-?
- o. f.t o a
v ww w
w on i
of.1 +-
Q i 4.o
^
Co.o,-
[3 f.tQ 10 n.
i.Vo C
.I o..I C
.e V
e v
6 010 158 1.9 1,9.6 +-
.6,l 2.9 17.5 +-
.8 l 3.9
- 4. e nne n
4 n.
.,n
,1 ell coJ 1.1 44 0 t-
.c 0.t cc.b t-
.0 14 0' + -
.o ',
4'.1
- n. '1 -
?59
- 1. 4 01.1. +-
.b 0. 0'-
O f.t. 0 +-
Q '
~
?
5 19.2 +- 1.4 7
UPHIND CONTROL ORTA 18.5 +
.9 3
LACROSSE TLD DlRECT RADIATIOt1 ENVIRONMENTAL MONITORING FOR THE PERIOD 821221-830412 113 DAYS FIELD TIME 82 DAYS tiRC LOCATION GROSS HET EXFOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 57 20.
12.6 +-
.4 ;
1.9 11.4 +-~
.6 ;
3.1 002 5/
20.
13.1 +-
.4 l 2.0 11.9 +-
.7 l 3.1 003 3/
20.
14.1 +-
.4 ;
2.1 13.0 +-
.7 l 3.3 004 343 3.8 13.8 +-
.4 l 2.1 12.7 +-
.7 l 3.2 005 313 3.8 18.7 +-
.6 l 2.8 18.1 +-
.8 ;
3.8 006 291 3.0 14.5 +-
.4 l 2.2 13.5 +-
.7 l 3.3 007 261 4.8 14.0 +-
.4 l 2.1 13.0 +-
.7 l 3.2 008 249 30 11.7 +-
.3 l 1.7 10.4 +-
.6 l 3.0 nG9
?14 5.0 13.1 +-
.4';
2.0 12.0 +-
.7 l 3.1 010 171 9.8 12.0 +-
.4 l 1.8 10.7 +-
.6 l 3.0 011 176 5.1 12.9 +-
.4 l 1.9 11.7 +-
.6 l 3.1 012 165 4.9 10.9 +-
.3 ;
1.6 9.6 +-
.6 l 2.9 013 138 3.5 13.6 +-
.4 l 2.0 12.5 +-
.7';
3.2 014 114 4.2 10.8 +-
.3 l 1.6 9.5 +-
.6 l 2.9 015 97 3.9 13.1 +-
.4 l 2.0 12.0 +-
.7 l 3.1 016 94 3.0 11.6 +-
.3 ;
1.7 10.3 +-
.6 ;
3.0 017 105 2.0 14.1 +-
.4 l 2.1 13.0 +-
.7 l 3.3 018 52 1.5 13.0 +-
.4 l 2.0 11.9 +-
.7 l 3.1 019 16 1.5 12.7 +-
.4 l 1.9 11.5 +-
.6 l 3.1 020 1
1.0 13.4 +-
.4 ;
2.0 12.3 +-
. 7 ';
3.2 021 358 0.5 15.3 +-
.5 l 2.3 14.3 +-
.7 ;
3.4 022 180 0.6 13.9 +-
.4 l 2.1 12.9 +-
.7 l 3.2 023 134 1.7 14.9 +-
.4 ;
2.2 13.9 +-
.7 l 3.3 024 58 0.6 14.8 +-
.4';
2.2 13.8 +-
.7 ;
3.3 025 59 3.1 14.1 +-
.4 l 2.1 13.0 +-
.7 l 3.3
)
026 16 1.5 13.0 +-
.4 l 2.0 11.9 +-
.7 l 3.1 027 26 5.1 12.8 +-
.4 l 1.9 11.6 +-
.6 l 3.1 028 20 c.0 13.1 +-
.4 l 2.0 11.9 +-
.7 ;
3.1 029 4
4.8 13.6 t-
.4 l 2.0 12.5 +-
.7 l 3.2 TRAt1 SIT DOSE =
2.2
+-
.4 ; 2.1 l
i 1
LACROSSE FOR THE PERIOD 821221-830412 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dsg.)
NET AVER. EXPOSURE RATE t IN GROUP (mR/Std.Otr.) t-Std.Dev.
348.75-Il.25 (N) 13.1 +- 1.1 3
11.25-33.75 (NNE) 11.7 +
.2 4
33,75-56.25 (NE)
It.9 +- 0.0 1
56.25-78.75 (ENE) 13.4 +
.5 2
78.75-101.25 (E)
It.1 +- 1.2 2
10l.25-123.75(ESE) 11.2 +- 2.5 2
123.75-146.25(SE) 13.2 +- 1.0 2
145 25-150.75(55E) 9.5 4- 0.0 1
150.75-191.25(S) 11.8 +- 1.1 3
191.25-2t3.75(55N)
NO DRTR+-NO DRTR 0
a 213.75-236.25(SW) 12.0 +- 0.0 1
238.25-258.75(USW) 10.4 +- B.O 1
258.75-281.25fu) 13.0 +- 0.0 1
281.25-303.75tWNW) 13.5 +- 2.0 1
303.75-328.25(NN) 18.1 +- 0.0 1
326.25-348.75(NNN) 12.7 +- 0.0 1
DISTRNCE(mi) FROM THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP (mR/Std.Qtr.) +-5t d. De v.
0-2 12.B +- 1.0 9
2-5 12.2 +- 2.2 13 i
>5 ll.5 +
.5 4
i UPHIND CONTROL DATA 12.1 +
.8
'S i
LA SALLE TLD DIRECT RADI ATI0li EN'/IRONMEllTAL M0!lITORIllG FOR THE FERIOD 821222-830411 111 DAYS FIELD TIME 84 DAYS tlRC LOCATION GROSS tlE', EXPOSURE RATE STATI0ll RZIMUTH/DIST EXPOSURE (mR) mR/Std.0tr.
16.0 + ; Tot.
+- Rdm (dea.)
(mi.)
+- Rdm; Tot.
.8 ;
3.9 001 302 10.
18.6 +-
.6 ;
2.8 002 335 4.8 22.7 +-
.7 l 3.4 20.4 +-
.9 ;
4.4 003 343 5.8 13.6 4-
.4 l 2.0 10.6 +-
.7 ;
3.3 004 38 5.5 17.0 +-
.5 l 2.5 14.2 +-
.8 ;
3.?
005 39 4.3 17.4 +-
.5 l 2.6 14.7 +-
.8 l 3.7 006 27 3.8 21.0 +-
.6 l 3.1 18.5 +-
.9 ;
4.2 00r c55 4.1 21.7 +-
.6 l 3.2 19.3 +-
.9 ;
4.2 008 304 4.6 20.6 +-
.6 l 3.1 18.1 +-
.9 l 4.1 009 292 3.9 21.4 +-
.6 ;
3.2 18.9 +-
.9 l 4.2 010 276 3.7 19.0 +-
.6 l 2.9 16.4 +-
.8 l 3.9 011 245 4.0 21.0 +-
.6 ;
3.2 18.6 +-
.9 l 4.2 010'
~? 0")
12.
18.9 +-
.6 l 2.8 16.3 +-
.8 ;
3.9 013 212 18.
MISSIllG OR DAf1 AGED DOSIMETER 014 212 18.
MISSItlG OR DAMAGED DOSIMETER 016 215 4.4 MISSING OR DA!1 AGED DOSIMETER 4.3 015 212 18.
21.7 +-
.7 ;
3.3 19.3 +-
.9 ;
Olr z04 4.0
?2.7 +-
.7 ;
3.4 20.3 +-
.9 ;
4.4 018 173 4.3 20.4 +-
.6 l 3.1 17.9 +-
.9 l 4.1 019 174 6.4 19.5 +-
.6 l 2.9 16.9 +-
.8 l 4.0 020 158 4.9 18.9 +-
.6 ;
2.8 16.3 +-
.8 l 3.9 021 125 4.2 22.3 +-
.7 l 3.3 20.0 +-
.9 l 4.3 022 114 3.8 21.6 +-
.6 l 3.2 19.2 +-
.9 l 4.2 023 97 4.5 20.8 +-
.6*
3.1 18.3 +-
.9 ;
4.1 024 72 4.7 23.9 +-
.7 l 3.6 21.6 +-
.9 l
- 1. 5 025 41 2.0 18.7 +-
.6 l 2.8 16.1 +-
.8 ;
3.9 026 13 1.3 0'1.2 +-
.6 l 3.2 18.8 +-
.9 ;
4.2 027 358 1.5 22.6 +-
.7 l 3.4 20.2 +-
.9 l 4.4 028 336 1.6 19.8 +-
.6 l 3.0 17.3 +-
.8' 4.0
.8 ;;
4.0 029 310 2.3 19.4 t-
.6 ;
2.9 16.8 +-
.9' 030 301 2.0 23.5 +-
.7 ;
3.5 21.3 +-
4.5
.9 ;;
4.2 031 271 1.7 21.1 +-
.6 ;
3.2 18.6 +-
030 0'51 1.8 MISSIllG OR DAf1 AGED DOSIMETER 033 227 2.4
?0.7 +-
.6 ;
3.1 18.3 +-
.9 ;
4.1 034 204 1.7 21.6 +-
.6 ;
3.2 19.2 +-
.9 l 4.2
.9' 4.2 035 171 1.6 21.4 +-
.6 l 3.2 18.9 +-
.9 ;
036 153 1.S 20.3 +-
.6 l 3.0 17.8 +-
4.1
.9 ;;
037 139 2.1 22.4 +-
.7 l
- 3. 4 20.1 +-
4.3 038 111 1.5 19.0 +-
.6 l 2.8 16.4 +-
.8 ;
3.9 n39 271 0.6 21.2 t-
.6 l 3.2 18.7 +-
.9 ~;
4.2 TRA!iSIT DOSE =
3.7
+-
.5 ; 2.3
LA SALLE FOR THE PERIOD 821222-830411 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dag.)
NET AVER. EXPOSURE RATE
$ IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-ll.25 (N) 19.8 +
.7 2
11.25-33,75 (NNE) 18.7 +
.2 2
33.75-56.25 (NE) 15.0 +- 1.0 3
3 56.25-78.75 (ENE) 21.8 +- 0.0 1
78.75-10l.25 (E) 18.3 +- 0.0 1
101.25-123.75(ESE) 17.8 +- 2.0 2
123.75-146.25(SE) 2 0. 0 +
.1 2
14 5.25-158. 75 ( 55E J 17.1 +- 1.1 2
168.75-191.25(5) 17.9 +- 1.0 3
19 l. 25-2 l 3.75 ( 55N )
19.8 +
.8 2
213.75-236.25(SN) 17.3 4-1.4 2
236.25-258.75(W5W) 18.6 +- B.O 1
250.75-281.25(W) 17.9 +- 1.3 3
281.25-303.75(WNW) 18.7 +- 2.8 3
303.75-326.25(NN) 17.5 +
.9 2
326.25-348.75(NNN) 16.1 +- 5.0 3
OISTANCE(mi) FROM THE REACTOR NET RVER. EXPOSURE RHTE
+ I N GRO UP (mR/5td.Qtr.) +-5t d. De v.
B-2 18.5 +- 1.5 11 2-5 18.5 +- 1.7 18
>5 14.9 +- 2.5 5
UPHIND CONTROL ORTA 19.3 +- 0.0 1
i o
LIMERICK TLD DIRECT RADIATION elf /IRONMEt1TAL MONITORIllG FOR THE PERIOD 830110-830418 99 DAYS FIELD TIME 94 DAYS IIRC LOCATION GROSS WET EXPOSURE RATE STATI0tl AZIMUTH /DIST EXPOSURE (mR) kR/Std.Qtr.
+- Rdm; Tot.
(dea.)
Ou i. )
+- Rdm: Tot.
002 131 17.
MISSI!1G OR DAMAGED DDSIMETER
~
003 88 3.7 18.8 t-
.6 ;
2.8 t10 NET EATA 004 52 3.2 16.8 +-
.5 l 2.5 NO HET DATA 005 23 3.5 16.3 +-
. 5 i - 2. 4 N0 tlET DATA 006 8
4.6 21.0 +-
.6 }
3.2 t10 llET DATA 007 340 7.1 15.1 +-
.5 ;
2.3 N0 llET DATA 008 330 3.6 19.3 +-
.6 t 2.9 t10 NET DATA 009 313 3.3 19.7 +-
.6 l 2.9 N0 NET DATA 010 291 4.8 19.8 +-
.6 l 3.0
!I0 NET DATA 011 303 2.9 19.0 +-
.6 l 2.9 H0 NET DATA 012 314 1.6 15.5 +-
.5 t 2.3 HO'HET DATR 013 352 1.7 18.8 +-
.6 ;
2.8 liG NET DATA 014 339 1.3 15.8 +-
.5 ;
2.4 tl0 tlET DATA 015 47 1.8 16.8 +-
.5 l 2.5 N0 tlET DATA '
016 71 2.7 18.9 +-
.6 l 2.3 t!0 tiET DATA 017 1?
.4 15.8 +-
.5 !
2.4 N0 llET DATA 018 286
.5 15.7 +-
.5';
2.4 N0 tlET DATA 019 276
.6 16.5 +-
.5 ;
2.5 110 iET DATA 020 245
.9 19.8 +-
.6 t 3.0 N0 t1ET DATA 021 224 1
19.4 +-
.6 l 2.9 N0 tlET DATA 022 202 1.:
16.6 +-
.5 l 2.5 ti0 NET DATA 025 172 1.6 16.4 +-
.5';
2.5 N0 t1ET DATA 024 150 1.7 12.2 +-
.4 ;
2.1 N0 t1ET DATA 025 132 1.2 19.7 + -
.6 ;
2.9 N0 tlET DATA 026 120 1.0 46.6 +-
.5 ;
2.5 NO HET IATA 027 160 1
15.6 +-
.5 !
2.3 N0 t1ET DATR 028 91 1
19.9 +-
.6 l 3.0 H0 SET DATA 029 67
.7 16.6 +-
.5 l 2.5 110 MET DATA 030 146 3.4
.18.1 +-
.5';
2.7 trj HET DATA 031 158 2.8 20.4 +-
.6 l 3.1 1,0 11ET DATA 033 184 4.3 14.9 4-
.4 l 2.?
'i0 NET DATA 034 201 3.9 15.5 +-
.5~;
2.3 NO NET DATA 2.8 H0 llET DATA
.6' 035 22d 3.1 18.8 +-
.~5 ;; 2.4 N0 llET DATA 036 245 4.2 15.8 +-
037 266 3.9 16.4 +-
.d l 2.5 ti0 tlET DATA 038 290 15 19.4 +-
'. 6 l 2.9 H0 t1ET DATA 039 290 15 19.1 +-
,.6';
2.9 t10 llET DATA 040 290 15 18.? + -
.5 l 2.7 H0 flET DATA 2.5 t10 t1ET DATA
.5' 16.8 +-
.6 ;
041 128 2.9 H0 tlET DATR 042 111 4.4 19.3 +-
tl0 TRANSIT DOSE CALCULATED (TLD, CONTROLS'HISSIhG OP OTH;ERWISE NOT COMPLETE) e
_l 4
l' I_
l l 'i,
' L.,
4
-)
. d d
)
s e
I e
. t
LH1ERICK FOR THE PERIOD 830110-530418 TLD DIRECT RADI ATION EtiVIR0!i!1E! ITAL t10!ilTOPING RZIrluTH (dag.)
RVER. EXPOSURE RATE t IN GROUP (mR/Std.Otr.) t-Std.Dev.
348,75-ll.25 (N) 18.1 +- 1.4 2
11.25-33.75 (NNE) 14.5 +
.3 2
33.75-56.25 (NE) 15.3 +
.D 2
1 56.25-78.75 (ENE) 16.1 +- 1.5 2
78.75-101.25 (E) 17.5 +
.7 2
10l.25-123.75(ESE) 16.3 +- 1.8 2
123.75-146.25fSE) 16.5 +- 1.3 3
14 5.25-168. 75 ( 55 E s 15.2 +- 2.9 3
168.75-191.25(5) 14.2 4-1.0 2
191.25-2L3.75(55H) 14.6 4-
.7 2
213.75-236.25(SW) 17.3 +
.4 2
236.25-258.75tHSH) 16.2 +- 2.6 2
258.75-281.25(H) 14.9 +
.1 2
28l.25-303.75(HNH) 16.5 +- 2.0 3
303.75-326.25(NH) 16.0 +- 2.7 d
326.25-348.75(NNN) 15.2 +- 2.0 3
DISTANCE (mi) FR0t1 THE REACTOR RVER.EXPOSUPE RATE
+ IN GROUP (nR/5td.Qtr.) +-5td.Dev.
0-2 15.5 +- 1.6 17 2-5 16.4 +- 1.7 17
>5 15.4 +- 2.4 2
UPHIND CONTROL DATA 17.1 +-.6 3
MAltlE VANKEE TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821222-830413 113 DAYS FIELD TIME 93 DAYS NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dsa.)
(mi.)
+- Rdm: Tot.
+- Rdm; Tot.
002 6~
1.4 MISSING OR DAMAGE,D DOSIMETER
~
G *io oo 1.e o, o +-
.D o.o to.o A-o.,
e.o b'V
- V 1
3 casa c
AV V 3
. V 004 44 1.8 MISSING OR DAMAGED DOSIMETER
~
J V V
005 116
.5 21.3 +-
.6 :
3.2 18,.3 +-
8; 3.8 6, e,
,1 Ir.,c +-
. u.,c +.-
.o.,
000 1t0 1
0.
0.
c 007 185 1.6 20.2 +-
.6 ;
3.0 17.2 +-
8l 3.6 008 195 2.3 19.5 +-
.6 l 2.9 16.5 +-
8l 3.6 009 209 3.A 00.3 +-
.6 ;
3.0 17.4 +-
8l 3.7 010 310 1.7 19.6 +-
.6 l 2.9 16.6 +-
8l 3.6 011 290 1.8 21.0 +-
.6 l 3.1 18.0 +-
8l 3.<
- n. i o_
0r9 i,
91.t +-
.e
,e o. _o i s.. o +. -
- a. e 2.vo v
. 7, 3.4 v
013 256 1.9 18.3 +-
.5 ;
2.7 15.4 +-
8; j
014 232 2.5 21.1 +-
. 6 -l 3.2 18.1 +-
3.7 n.is
???.
- s.. '
$ a,. es +-
.c, 9.a 16_. 5_ + -
o e
- 6 v. o'
?
1 016 246 4.4 21.1 +-
.6 l 3.2 18.1 +-
8; 3.7 01?
250 6.6 25.4 +-
.8 l 3.8 22.3 +-
9l 4.3 018 268 47 22.6 +-
.7 ;
3.4 19.5 +-
8l 3.9 4,-
no.
4
- a
.4
,6
,e Uis ca 4.4 1a.,o t-
.c, c.;
16.4 +-
c,
o.s 020 305 4.7 20.4 +-
.6 ;
3.1 17.5 +-
8l 3.7 6
n_ o i on_ n_
9o w..e +-
.D 9.1 17.e +-
o,.
o. -[
on d v
I d
. V V
-a v
w.
s 022 332 2.7 MISSING OR DAMAGED DOSIMETER 0??
On 3.9 21.8 +-
.7 ;
3.3 18.8 +-
8; 3.8 024 23 3
21.5 +-
.6 l 3.2 18.5 +-
8l 3.8 025 42 4.7 21.2 +-
.6 l 3.2 18.2 +-
8l 3.8 n_. ? c cn.
led 21.o +-
.D
,6 o.o 1U.w9 9 +-
o,e ao v
v m
V o's v.V
- e 8
,e n_ o,,
co
- i. c.
oi.n_ +-
.c, o.o to.a_ +-
o. 'c v
u v
s 028 63 16.
19.4 +-
.6 ;
2.9 16.5 +-
3.5 029 64 2.1 MISS, LNG OR DAMAGED DOSIMETER.
U :. 0.-
04
- 1. _;
It.o t-
.s a,
9. o-14.4 t-t e,
o.o
+r
,A g
A A
c 031 115 1.6 20.0 +-
.6 l 3.0 17.1 +-
8l 3.6 032 135 2
20.4 +-
.6 l 3.1 17.4 +-
8l 3.7 033 66 3.5 20.0 +-
.6 l 3.0 17.0 +-
8l 3.6 2,o.6 +-
.6 l 3.2 18.6 +-
8l 3.8 034 97, 4.9 1
e v.o t o. a.
- 4. -
qe o.q pssa i1co 4.v x
0 c c. ps,
o s
. u,
v.
036 140 4.9 22.3 +-
.7 l 3.3 19.3 +-
8; 3.9 037 151 6
22.6 +-
.7 l 3.4 19.6 +-
8; 3.9 l
038 152 4.2 22.1 +-
.7 ;
3.3 19.1 +-
8; 3.9 039 172 4.4 93,.0 +-
.7 l 3.4 19.9 +-
8l 4,. 0 1q e,.s 4-o,i o. Q, V 464 I vo-c.,.4 gc.es +-
. 'r 4-e o 4 TRANSIT DOSE =
2.4
+-
.5 ; 2.2 v.4
. v ~
i l
f1AlliE YAliKEE FOP THE PERIOD 821222-830413 TLD DIRECT RADI ATIO!i EtiVIR0tiMEliTAL f10tiiTORI!!G RZINUTH (dsg.)
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Ctr.) t-Std.Dev.
348,75-11.25 (N)
NO DATG+-N0 DATR 0
11.25-33.75 (NNES 18.5 +
.2 3
33,75-56.25 (NE) 18.2 +- 0.0 1
56.25-78.75 (ENE) 17.0 +- 0.0 1
78.75-101.25 (E) 16.5 +- 2.9 2
10l.25-123.75(ESE) 18.1 +- 1.0 3
123.75-146.25(SE) 18.4 +- 1.3 2
146.25-168.75(55E) 19.D +
.9 4
168.75-191.25(5) 18.6 +- 1.9 2
19l.25-2l3.75(55W) 17.0 4-
.6 2
213.75-236.25(SW) 17.3 +- 1.1 2
236.25-258.75(H5H) 18.6 +- 3.4 3
258.75-281.25(H) 19.1 +
.7 2
281. 25-3 03. 75 ( HNW) 17.3 +
.8 3
303.75-326.25(NH) 17.1 +.6 2
326.25-348.75(NNH)
NO DRTA+-NO DATR 0
DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP
( n,R/ 5t d. Q t r. )
+-St d. De v.
0-2 17.2 +- 1.3 11 2-5 18.2 +- 1.0 17
>5 19.5 +- 2.3 4
UPHIND CONTROL DATA 17.6 +- 1.0 3
MCGUIRE TLD DIRECT RADI ATION EtWIRONMENTAL MONITORIllG FOR THE PERIOD 821221-830401 102 DAYS FIELD TIME 86 DAYS HRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMOTH/DIST EXPO 5URE(mR) mR/Std.0tr.
(dea.)
(mi.>
+- Rdm; Tot.
+- Rda; Tot.
001 97-0.5 18.0 +-
.5 ;
2.7 13.3 + ' 1.2 ;
5.1 002 323 1.6 19.1 +-
.6 l 2.9 14.5 +-
1.2 l 5.2 003 336 1.7 23.7 +-
.7 l 3.6 19.3 +-
1.3 l 5.7 004 303 2.9 20.8 +-
.6 l 3.1 16.3 +-
1.2 l 5.4 005 321 3.9 16.6 +-
.5 l 2.5 11.9 +-
1.1 l 5.0 006 334
- 3. ?
18.5 +-
.6 l 2.3 13.8 +-
1.2l 5.2 Our
- 352, 3,. 5 16,.0 +-
.5 l 2.4 1.3 +-
1.,1 ;
5.0 1,4 a
e.,3
- 3
..c +-
1.c i
L1u c..
zer c.e ly.4 +-
.6, s-c.
009 273 1.9 18.6 +-
.6' 2.3 14.0 +-
1.2 l 5.2 010 244 1.7 15.7 +-
.5 l 2.4 11.0 +-
1.1 l 4.9 011 225 2.1 15.6 +-
.5 l 2.3 10.8 +-
1.1 l 4.9 01?
012 3.6 20.3 +-
.6 l 3.0 15.8 +-
1.2 ;
5.3 014 z53 i.,<
zu.6 +-
.6 ;
3.1 1D.1 +-
1.2,
- 5. 5, o.3 17 7 +-
1.0 39 74 99 4
0_9.o 4-n.1.2 V
i, 5.,
015 261 4.2 15.6 +-
.5 l 2.3 10.8 +-
1.1 l 4.9 016 288 4.i 23.5 t-
.7 ;
3.5 19.1 +-
1.3 l 5.7 O!?
288 16.
MISSING OR DAMAGED DOSIMETER
~
1.'
" D' AlVo
~0' 1'. 'J C' w?. o + -
7 o. 4' lo.1 +-
LVI V -
i q
w U s L
V.
5 0,19 2S6 16,.
21.4 +-
.6 ';
3.2 16,.9 +-
1.2 l 5.4
,33
, +-
y -
c..
1r.c +.-
1.,
e.ess Utu cVV 1<.
et.:
v 3 c,
001 904 10.
14.4 t-
.4 l 2.2 9.6 +-
1.1 l 4.8 00?
?39 9.5 19.9 +-
.6 l 3.0 15.4 +-
1.2 l 5.3 I
02?
115 4.9 MISSItiG OR DAMAGED DOSIMETER
~
024 132 4.9 16.9 +-
.5 ;
2.5 12.2 +-
1.1 ;
5.0 025 156 4.0 16.7 +-
.5 l 2.5 12.0 +-
1.1 ;
5.0 026 1 75 1.7 13.5 +-
.4 l 2.0 8.7 +-
1.1 l 4.8 027 198 4.3 21.0 +-
.6 l 3.1 16.5 +-
1.2 l 5.4 028 169 12, 16.5 +-
.5 l 2.5 11.8 +-
1.1 l 5.0 029 155 12.
14.9 t-
.4 ;
2.2 10.1 +-
1.1 ;
4.9 030 146 13.
18.3 +-
.5 ;
2.7 13.7 +-
1.2 ;
5.2 031 143 1.9 MISSING OR DAMAGED DOSIMETER 032 155 1.3 18.8 +-
.6 ;
2.3 14.2 +-
1.2 ;
5.2 033 178 1.6 17.7 +-
.5 ;
2.6 13.0 +-
1.2 ;
5.1 034 108 2.0 15.9 +-
.5 l 2.4 11.1 +-
1.1 ;
5.0
~
035 93 2.2 17.3 +-
.5';
2.6 12.6 +-
1.1 l 5.1 036 68 2.5 18.5 +-
.6 l 2.3 13.9 +-
1.2 ;
5.2 037 82 4.7 16.3 +-
.5 ;
2.4 11.6 +-
1.1 ;
5.0 038 64 4.9 18.8 +-
.6 l 2.3 14.2 +-
1.2 l 5.2 039 42 5.0 MISSING OR DAMAGED DOSIMETER
~
041 42 2.0 MISSING OR DAMAGED DOSIMETER
~
5.3 040 26 4.3 19.5 +-
.6 ;
2.9 14.9 +-
1.2 ;
049 01 1.6 18.0 +-
.5 ;
2.7 13.3 +-
1.2 '
5.1 043 8
2.6 19.0 +-
.6 ;
2.8 14.4 +-
1.2 ;
5.2 044 37/
13, 24.8 +-
.7 l 3.7 20.4 +-
1.3 ;
5.8 045 78/
18, 28.7 +-
.9 ;
4.3 24.6 +-
1.4 l 6.2 046 94/
18.
21.5 +-
.6 l 3.2 17.0 +-
1.2 l 5.5 TRANSIT DOSE =
5.2
+-
1.0 ; 4.1
~
1
\\
i 1
MCGUIRE FOR THE PERIOD 821211-830401 TLD DIPECT RADIATION ENVIRONMENTAL MONITORING RZIt1UTH (dag.)
NET AVER. EXPOSURE RATE 4 IN GROUP q
(mR/Std.Ctr.) t-Std.Dev.
J 348.75-It.25 (N) 12.8 +- 2.2 2
i 11.25-33.75 (NNE) 14.1 +- 1.1 2
33.75-56.25 (NE) 20.4 +- 0.0 1
56.25-78.75 (ENE) 17.5 +- B.1 3
78.75-10l.25 (E) 13.6 +- 2.4 4
1 101.25-123.75(ESE) ll.1 +- 0.0 1
1 123.75-146.25(SE) 13.D +- 1.0 2
I 14 5.25-158.75 t 55E )
12.1 4-2.0 3
158.75-191.25(5) ll.2 4-2.2 3
191.25-2t3.75(55H) 13.9 4-3.8 3
213.75-236.25(SH) 15.4 +- 4.0 3
236.25-258.75(HSH) 14.1 +- 2.8 3
258.75-281.25(W) 12.4 +- 2.2 2
28 t.25-303.75 (HNW) 18.7 +- 2.2 3
303.75-326.25(NH) 13.2 +- 1.9 2
t 326,25-348.75(NNN) 16.6 +- 3.9 2
i DISTANCE (mi) FR0ft THE REACTOR NET RVER. EXPOSURE RATE
+ - I N GR OUP (nR/Std 0tr.)
+-5t d. De v.
B-2 13.9 +- 2.3 la i
j 2-5 13.7 +- 2.7 20 l
>5 15.E +- 4.9 9
UPNIND CONTROL ORTA 17.6 +- 1.0 2
l
~, _.. _. _
MILLST0!lE TLD DIRECT RADIATI0li ENVIRONMENTAL MONITORING FOR THE PERIOD 821222-830420 120 DAYS FIELD TIME 100 DAYS t1RC LOCATI0t1 GROSS tlET EXPOSURE RATE STATIO!i RZIMUTH/DIST EXPOSURE (mR) mR/Std.Qtr.
(dec.)
(mi.)
+- Rdm; Tot.
+- Roa; Tot.
001 0-1 14.9 +-
.4 ;
2.2 110 NET' DATA 000' c'4 1.3 13.3 +-
.4 l 2.0 N0 flET DATA 003 47 1.5 15.1 +-
.5 l 2.3 NO HET DATA 004 60 1.7 13.1 +-
.4 ;
2.0 NO NET DATA 005 85 1.3 15.5 +-
.5';
2.3 NO HET DATA 006 110 1.8 15.9 +-
.5 ;
2.4 N0 tiET DATA 007 67 5.3 16.0 +-
.5 ;
2.4 N0 flET DATA 008 49 5.3 15.9 +-
.5 l 2.4 N0 11ET DATA 009 84 5.2 14.7 +-
.4 l 2.2 NO NET DATA 011 232 2.5 14.7 +-
.4 ;
2.2 N0 tiET DATA 012 256 2.4 15.7 +-
.5 t 2.4 NO NET DATA 013 274 2.2 15.4 +-
.5 l 2.3 N0 llET DATA 014 295 1.9 14.6 +-
.4 i 2.2 NO NET DATA 015 315 1.5 13.3 +-
.4 ;
2.0 NO NET DATA 016 339 1.2 16.7 +-
.5 l 2.5 NO NET DATA 017 353 3.5 17.1 +-
.5l 2.6 N0 i1ET DATA 018 24 3.5 15.2 +-
.5 ;
2.3 110 11ET DATA 019 33 3
16.0 +-
.5 t 2.4 t10 NET DATA 020 82 4
14.0 +-
.4 i 2.1 NO NET DATA 022 59 3.7 11.2 +-
.3 l 1.7 NO NET DATA 028 257 5.8 17.4 +-
.5 l 2.6 N0 llET DATA 029 272 3.7 17.2 +-
.5 ;
2.6 N0 llET DATA 030 295 3.5 16.3 +-
.5 ;
2.4 NO NET DATA 031 317 3.6 15.5 +-
.5 l 2.3 NO NET DATA 032 327 4.3 16.8 +-
.5 ;
2.5 NO !1ET DATA 033 41 4.7 15.8 +-
.5 l 2.4 t10 NET DATA 034 54 5.5 15.4 +-
.5 l 2.3 l10 NET DATA 037 354 6.8 15.7 +-
.5~;
2.4 NO NET DATA 039 1
5.7 16.0 +-
.5 l 2.4 110 NET DATA 040 278 8.7 13.7 +-
.4 ;
2.0 NO NET DATA 041 34 11.
21.1 +-
.6 ;
3.2 NO NET DATA 042 84 8
16.5 +-
.5 ;
2.5 l10 NET DATA
~
046 41
.6 14.3 +-
.4 ;
2.1 NO NET DATA 048 4
40 19.8 +-
.6 ;
3.0 t10 11ET DATA 049 4
40 18.8 +-
.6';
2.3 N0 flET DATA NO TRANSIT DOSE CALCULATED (TLD C0t1TROLS'MISSIt1G OR OTHERWISE NOT COMPLETE) 4 r-
MILLSTONE FOR THE PERIOD 821222-330420 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (deg.)
AVER. EXPOSURE RATE
$ IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-11.25 (N) ll.9 +
.7 4
11.25-33.75 (NNE) 11.1 +- 1.1 3
33.75-56.25 (NE) 12.2 +- 1.8 6
56.25-78.75 (ENE) 10.1 +- 1.8 3
78.75-101.25 (E) 11.4 +
.8 4
101.25-123.75(ESE)
It.9 +- 0.0 1
123.75-146.25(SE)
NO DRTR+-NO DATR 0
14 5.25-150. 75 ( 55 E )
NO DRTR&-NO DRTR 0
159.75-191.25(5)
NO DRTR&-NO DRTR 0
191.25-213.75 ( 55 N )
NO DRTR&-NO DATR 0
213.75-236.25(SW) 11.0 4-B.O 1
236.25-258.75(W5u) 12.4 +
.9 2
258.75-281.25(W) 11.6.+-
1.3 3
28l.25-303.75(WNW) 11.6 +
.9 2
l 303.75-326.25(NH) 10.B +- 1.1 2
326.25-348.75(NNN) 12.5 +
.0 2
DISTANCE (mi) FROM THE REACTOR RVER. EXPOSURE RATE
+ IN GROUP (mP/5td.0tr.)
+-5t d. De v,
0-2 11.B +
.9 la 2-5 11.6 +- 1.2 13 l
r
>5 12.2 +- 1.5 10 i
f UPNIND CONTROL DATA 14.4 +
.5 2
M0tiTICELLO TLD DIRECT RADIATION EtlVIR0t1 MENTAL MONITORING FOR THE PERIOD 821221-830411 112 DAYS FIELD TIME 92 DAYS tlRC LOCATI0t1 GROSS HET EXPOSURE RATE STATI0t4 AZIMUTH /DIST EXFOSURE(mR) mR/Std.Qtr.
(dec.)
(mi.)
+- Rda; Tot.
F-Rdm; Tot.
001 133 3.6 20.4 +-
.6 ;
3.1 16.8 +-~
.8 ;
3.9 002 163 4.6 21.5 +-
.6 ;
3.2 18.0 +-
.9 ;
4.0 003 183 4.1 20.8 +-
.6';
3.1 17.2 +-
.8 l 4.0 004 206 4.3 20.7 *-
.6 ;
3.1 17.2 +-
.8 l 3.9 005 230 4.2 21.0 +-
.6 ;
3.2 17.5 +-
.9 l 4.0 006 253 4.6 22.0 +-
.7 l 3.3 18.4 +-
.9 ;
4.1 007 269 4.4 20.4 +-
.6';
3.1 16.9 +-
.8 l 3.9 008 286 4.0 22.2 +-
.7 l 3.3 18.6 +-
.9 l 4.1 009 274 1.9 20.0 +-
.6 l 3.0 16.4 +-
.8 l 3.9 010 244 1.3 19.6 +-
.6 l 2.9 16.1 +-
.8 l 3.8 011 226 0.9 20.1 +-
.6 l 3.0 16.6 +-
.8 ;
3.9 012 18,1 1.8 20.1 +-
.6 l 3.0 16.6 +-
.8 l 3.9 n e c
- a 1
1
, +_
.oi o. a,
- n. i w:
10vf i. :I o n_.,!
+_
.bq
).
1.C v
L 014 155 1.0 20.4 +-
.6';
3.1 16.9 +-
.8 l 3.9 015 208 0.5 20.6 +-
.6 l 3.1 17.1 +-
.8 ;
3.9 016 284 2.0 20.4 +-
.6 ;
3.1 16.9 +-
.8 l 3.9 017 113 1.6 13.8 +-
.4 ;
2.1 10.4 +-
.7 l 3.2 l
018 85 1.1 19.7 t-
.6 ;
3.0 16.2 +-
.8 l 3.8 019 63 1.2 19.6 +-
.6 ;
2.9 16.1 +-
.8 ;
3.8 020 37 1.7 20.2 +-
.6 ;
3.0 16.7 +-
.8 ;
3.9 021 23 0.8 20.4 +-
.6 ;
3.1 16.9 +-
.8 l 3.9 022 35,4 0.7 20.1. +.-
.6 l 3.0
- 16. 5 +-
.8 '.;
3.9
- r....
U +0 JJ0 U..0 20.-.4 t-
.b d.1 16.8 t-
.8 ;
d.y E
a o
n?4 C f_i:
- 1.. e 1 Q<. 5. +. -
6_ a
?. Q, i " f_t +_
.o o.v 15.
v,
v
-4 v
m 025 339 4.1 20.< +-
.b 3.1 17.2 +-
.8 ;
3.9 026 320 4.6 14.3. +-
.4 ;
2.1 10.9 +-
.c ;
- 3. 3, i
o t
.e..
4 =
n n.o 14.9 +-
.n v.c
., u.,
ase 4.;
- 3. o. 4 +-
.6 c s o
029 17 3.7 19.6 +-
.6 l 2.9 16.1 +-
.8 ;,
3.8
.8' 3.7 029 50 4.0 18.9 +-
.6 ;
2.3 15.4 +-
.8 ;
030 77 3.6 20.8 +-
.6 l 3.1 17.2 +-
4.0 n.ot ils s:. o.8 lo.a. +*-
.c e 1.ss +-
.oe o.o w.2
?
)
v q v V v
w s
w q
e 032 90 4.6 21.0 +-
.6 l 3.1 17.4 +-
.9';
4.0 033 3 0'd 15.
20.0 +-
.6 l 3.3 16.4 +-
.8 l 3.9 034 323 15.
20.0 +-
.6 l 3.0 16.4 +-
.8 l 3.9 035 323 15.
19.4 +-
.6';
2.9 15.9 +-
.8 l 3.8 TRellSIT DOSE =
3.1
+-
.6 ; 2.6
~
MONTICELLO FOR THE PERIOD 821221-530411 TLD DIRECT RADIATION ENVIR0!iMENTAL MONITORI!1G RZIt1UTH (dag.)
NET AVER. EXPOSUPE RATE 4 IN GROUP (mP/Std.Otr.) t-Std.Dev.
348.75-ll.25 (N) 15.7 +- 1.2 2
11.25-33.75 (f4NE) 16.5 +-.6 2
33.75-56.25 (NE) 16.0 +
.9 2
56.25-78.75 (ENE) 16.7 +
.8 2
78.75-10l.25 (E) 16.B +
.9 2
101.25-123.75(ESE) 12.9 +- 3.6 2
123.75-146.25(SE) 17.0 +
.2 2
145.25-150.75(55E) 17.4 4-
.8 2
160.75-191.25l5) 15.9 +
.4 2
191. 2 5-2 l 3. 75 ( 55 H )
17.1 4-
.1 2
213.75-236.25(SW) 17.0 4-
.6 2
236.25-258.75(H5H) 17.2 +- 1.6 2
258.75-281.25(H) 16.7 +
.3 2
28l.25-303.75(HNH) 17.7 +- 1.2 2
303.75-326.25(NH) 13.4 +- 3.6 2
326.25-348.75(NNH) 17.0 +
.2 2
DISTANCE (mi) FROM THE PEACTOR NET RVER. EXPOSURE PATE
+ IN GROUP imR/5td.Otr.) + -St d. De v.
2-2 16.2 +- 1.6 16 2-5 16.6 +- 1.8 16
>5 NO DATA +-NO DATR D
UPHIND CONTROL DATA 16.3 +
.3 3
NORTH AtlllA TLD DIRECT RADIATI0fl EtWIRONMENTAL MONITORING FOR THE PERIOD 821222-830414 114 DAYS FIELD TIME 92 DAYS NRC -
LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 243 1.8 24.9 +-
.7 ;
3.7 20.8 +-~
.9 ;
4.3 002 263 1.6 22.1 +-
.7 ;
3.3 18.1 +-
.8 l 3.9 003 296 1
21.7 +-
.7 l 3.3 17.7 +-
.8 ;
3.9 004 311 1.3 26.3 +-
.8 ;
3.9 22.2 +-
.9 ;
4.4 005 329 1.3 23.0 +-
.7 ;
3.5 19.0 +-
.9 l 4.0 006 231 3.9 23.7 +-
.7 l 3.6 19.7 +-
.9 ;
4.1 007 224 1.7 23.6 +-
.7 ;
3.5 19.5 +-
.9 ;
4.1 008 210 1.6 22.1 +-
.7 ;
3.3 18.1 +-
.8 ;
3.9 009 181 1.4 20.2 +-
.6 l 3.0 16.2 +-
.8 3.7 1.0 ;
010 155 1.'
28.0 +-
.8 l 4.2 23.8 +-
4.7
.8 ;
011 136 1.6 22.4 +-
.7 l 3.4 18.3 +-
4.0 01?
163 3.5 22.4 +-
.7~;
3.4 18.4 +-
.8 ;
4.0 013 190 3.3 21.4 +-
.6 l 3.2 17.4 +-
.8 ;
3.8 014 205 4.9 22.4 +-
.7 ;
3.4 18.3 +-
.8 ;
4.0 015 140 4.?
?3.1 +-
.7';
3.5 19.0 +-
.9';
4.0 016 113 4.c 96.3 +-
.8 ;
3.9 22.2 +-
.9 ;
4.4 017 93 3.3 19.6 +-
.6 ;
2.9 15.6 +-
.8 ;
3.6 018 64 4.1 22.4 +-
.7 l 3.4 18.3 +-
.8 ;
4.0 019 78 2.7 31.0 +-
.9';
4.7 26.8 +-
- 1. 0 ~;
5.1 020 97 1.9 22.7 +-
.7';
3.4 18.6 +-
.8';
4.0 021 105 1.7 20.5 +-
.6 l 3.1 16.5 +-
.8' 3.7
.8 ;
022 60 2.4 20.7 +-
.6 l 3.1 16.7 +-
3.8 023 37 1.4 22.8 +-
.7 l 3.4 18.7 +-
.8 l 4.0 024 16 1.6 25.2 +-
.8 l 3.8 21.1 +-
.9 l 4.3 025 48 3.5 18.6 +-
.6 ;
2.8 14.6 +-
.8 ;
3.5 026 17 3.7 22.8 +-
.7';
3.4 18.8 +-
.8 ;
4.0 027 3
4.8 22.0 +-
.7 j 3.3 18.0 +-
.8 ;
3.9 028 348 4
22.2 +-
.7 ;
3.3 18.2 +-
.8 l 3.9 029 2
1.9 19.9 +-
.6 l 3.0 15.9 +-
.8 ;
3.7 030 284 5
20.8 +-
.6 ;
3.1 16.8 +-
.8 ;
3.8 031 310 4.7 23.8 +-
.7 ;
3.6 19.7 +-
.9-4.1 032 273 4.9 19.4 +-
.6 l 2.9 15.5 +-
.8 l 3.6 033 257 5.1 21.9 +-
.7~
3.3 17.9 +-
.8 ;
3.9
.7 ;;
034 242 7.1 22.3 +-
3.3 18.2 +-
.8 l 4.0 035 255 11.
20.4 +-
.6 ;
3.1 16.4 +-
.8 ;
3.7 036 248 15.
21.7 +-
.6 ;
3.2 17.7 +-
.8 ;
3.9 037 247 17.
19.7 +-
.6 ;
3.0 15.8 +-
.8 ;
3.6 038 244 19.
18.2 +-
.5 ;
2.7 14.2 +-
.7 ;
3.5 TRANSIT DOSE =
3.6
+-
.5 ; 2.3 1
l
NORTH ANNA FOR THE PERIOD 821222-830414 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dog. )
NET AVER. EXPOSURE RATE 4 IN GROUP (mP/Std.Qtr.) t-Std.Dev.
348.75-11.25 (N) 17.0 +- 1.5 2
11.25-33.75 (NNE) 20.0 +- 1.7 2
2 33.75-56.25 (NE) 16.7 +- 2.9 2
56.25-78.75 (ENE) 20.6 +- 5.4 3
f 78.75-101.25 (E) 17.1 +- 2.1 2
i 10l.25-123.75(EEE) 19.3 +- 4.0 2
123.75-148.25(SE) 18.7 +
.5 2
l 14 5.25-168. 75 ( 55E) 2l.1 4-3.8 2
168.75-191.25(5) 16.8'+
.8 2
191.25-2t3.75(55N) 18.2 4-
.2 2
213.75-236.25(SH) 19.6 4-
.1 2
238.25-258.75(W5W) 18.3 +- 1.8 4
258.75-201.25(H) 18.8.+-
1.9 2
281.25-303. 75 ( WNW )
17.3 +
.6 2
303.75-328.25(NN) 20.9 +- 1.7 2
326.25-348.75(NNN) 18.6 +
.6 2
DISTANCE (mi) FR0t1 THE REACTOR NET RVER. EXPOSURE RATE 4 IN GROUP l
(mR/Std Qtr.) +-5td.Dev.
2-2 19.B +- 2.2 15 2-5 18.5 +- 2.8 17
>5 17.5 +- 1.0 3
i UPNIND CONTROL DRTA 15.9 +- 1.7 3
OC0tlEE TLD DIRECT RADIATION ENVIRONMENTAL M0llITORING FOR THE PERIOD 821222-830426 126 DAYS FIELD TIME 85 DAYS tlRC LOCATI0li GROSS NET EXPOSURE RATE STATI0tl AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
19.3 + ; Tot.
+- Rdm (dea.)
(mi.)
+- Rdm; Tot.
1.0 ;
5.0 001 158 7.5 26.1 +-
.8 ;
3.9 002 133 4.9 28.9 +-
.9 l 4.3 22.2 +-
1.1 l 5.4 003 119 4.3 26.5 +-
.8 l 4.0 19.7 +-
1.1 l 5.1 004 84 4.7 27.8 +-
.8 l 4.2 21.1 +-
1.1 l 5.2 005 65 4.0 20.9 +-
.6 l 3.1 13.8 +-
.9 l 4.3 4
006 52 1.8 26.7 +-
.8 l 4.0 19.9 +-
1.1 ;
5.1 007 29 1 5 26.6 +-
.8 l 4.0 19.9 +-
1.1 ;
5.1 008 33 1.4 21.0 +-
.6 l 3.1 13.9 +-
.9 l 4.4 009 52 1.8 23.7 +-
.7 l 3.6 16.8 +-
1.0 ';
4.7 010 66 1.2 21.2 +-
.6 l 3.2 14.1 +-
.9 l 4.4 011 107 1.9 22.5 +-
.7 l 3.4 15.5 +-
1.0 ;
4.5 012 87 1.0 22.1 +-
.7 l 3.3 15.0 +-
.9 ;
4.5 013 142 0.7 25.1 +-
.8 l 3.8 18.2 +-
1.0 l 4.9 014 166 0.7 MISSING OR DAMAGED DOSIMETER 015 226 1.7 25.4 +-
.8 ;
3.8 18.6 +-
1.0 ;
4.9 016 207 1.4 24.2 +-
.7.!
3.6 17.3 +-
1.0 l 4.8 017 182 2.2 21.6 +-
.6 l 3.2 14.5 +-
.9 ;
4.4 018 186 3.8 MISSING OR DAMAGED DOSIMETER 019 155 4.1 MISSIllG OR DAMAGED DOSIMETER 020 203 S.4 21.9 +-
.7 ;
3.3 14.8 +-
.9 ;
4.5 021 210 4.6 26.0 +-
.8 l 3.9 19.2 +-
1.0 l 5.0 022 227 4.8 22.4 +-
.7 l 3.4 15.4 +-
1.0 '
4.5 1.0 ;
023 240 3.6 23.5 +-
.7';
3.5 16.6 +-
4.7 024 268 3.6 26.5 +-
.8 ;
4.0 19.7 +-
1.1 ;
5.1 025 257 1.?
20.4 +-
.6 ;
3.1 13.2 +-
.9 ;
4.3 026 293 3.6 22.9 +-
.7 ;
3.4 15.9 +-
1.0 l 4.6 027 311 3.5 24.3 +-
.7 ;
3.6 17.4 +-
1.0 ;
4.8 028 288 2.0 24.8 +-
.7 l 3.7 17.9 +-
1.0 ;
4.8 029 275 1.8 24.5 +-
.7 l 3.7 17.6 +-
1.0 l 4.8 030 321 1 ?
02.4 +-
.7 l 3.4 15.4 +-
1.0 l 4.5 031 344 2.0 91.2 +-
.6 l 3.2 14.1 +-
.9 ;
4.4 032 336 3.7 29.6 +-
.9 l 4.4 23.0 +-
1.1 ;
5.5 033 358 4.5 24.7 +-
.7l 3.7 17.8 +-
1.0 ;
4.8 034 256 9.4 29.2 +-
.9~;
4.4 22.6 +-
1.1 ;
5.4 035 149 21, 20.6 +-
.6 ;
3.1 13.5 +-
.9 l 4.3 i
036 126 8.2 26.8 +-
.8 ;
4.0 20.1 +-
1.1 l 5.1 037 96 9.7 26.5 +-
.8' 4.0 19.7 +-
1.1 ;
5.1 040 29/
15.
MISSINGORDRI1AGEDDOSIMETER TRAtlSIT D05E =
7.9
+-
.6 ; 2.7 l
l I
ww w
~
=_.
OC0llEE FOR THE PERIOD 821222-830426 I
i TLD DIRECT RADI ATIO!! EllVIR0!1ME!1TPL M0!IITORI!1G RZIMUTH (dag.)
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Otr.) t-Std.Dev.
i l
348,75-1L.25 (N)
- 17. 8 +- 0.0 1
11.25-33,75 (NNE)
- 16. 9 +- 4. 2 2
l 33.75-56.25 (NE) 18.3 +- 2.2 2
56.25-78.75 (ENE) 13.9 +
.2 2
78.75-!OL.25 (E)
- 18. 6 +- 3. 2 3
4 101.25-123.75(ESE) 17.6 +- 3.0 2
12 3. 75-14 6. 25 ( S E )
2 0. 2 +- 2. 0 3
j 14 5.25-168. 75 ( 5 5 E )
15.4 4-4.1 2
168.75-191.25(5) 14.5 4- 0.0 1
131.25-213.75(55N) 17.1 4-2.2 3
i 213.75-236.25(SH) 17.0 4-2.2 2
238.25-258.75(HSW)
- 17. 5 +- 4. 7 3
l 258.75-281.25(W) 18.6 +- 1.5 2
i.
28l.25-303.75(HNW)
- 18. 9 +- 1. 4 2
j 303.75-328.25(NH)
- 16. 4 +- 1. 4 2
l 326.25-348.75(NNH) 18.6 +- S.3 2
i l
l 1
DISTANCE (mi) FR0t1 THE PEACTOP NET RVER. EXPOSURE RATE
+ IN GROUP l
(mR/5td.Qtr.) + -St d. De v.
B-2 16.3 +- 2.1 14 2-5
- 18. 3
-e-2. 8 14
>5
- 18. 3 +- 3.4 6
UPNIND CONTROL DRTA NO DATA NO DATA
0YETER. CREEK l
TLbDIRECTRADIATIONENVIR0tiMENTALMONITORING t
FOR THE PERIOD 821222-830412 112 DAYS FIELD TIME 92 DAYS I
l NRC LOCATION GROSS tlET EXPOSURE RATE i
STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
12.0 + ; Tot.
+- Rdm i
(dea.)
(mi.)
+- Rdm; Tot.
I 001 141
.5 14.2 +-
4; 2.1 5.;
2.4 00?
120
.9 16.2 +-
5; 2.4 14.0 +-
6; 2.7 003 105 1.5 14.9 +-
4; 2.2 12.7 +-
5; 2.5 004 127 1.5 15.4 +-
5l 2.3 13.3 +-
5 2.6 5.;;
2.6 t
005 137 1.3 15.5 +-
5; 2.3 13.4 +-
2 006 158 1.2 14.4 +-
4; 2.2 12.2 +--.. 5l 2.4 007 176 2.2 15.1 +-
5; 2.3 13.0 +-
5l 2.5 i
008 179 1.6 13.9 +-
4; 2.1 11.7 +-
5l 2.4 009 159 2.8 13.5 +-
4l 2.0 11.4 +-
5l 2.3 010 187 8.4 15.5 +-
5l 2.3 13.4 +-
5l 2.6 011 173 4.4 14.4 +-
4l 2.2 12.3 +-
5; 2.5 012 196 4.2 MISSING OR DAf1 AGED DOSIMETER 013 198 8.6 14.3 +-
4; 2.1 12.2 +-
5; 2.4 014 185 10.
15.7 +-
5; 2.3 13.5 +-
5; 2.6 015 171 10.
12.9 +-
4' 1.9 10.8 +-
5l 1
016 154 8.2 MISSINGORDAllAGEDDOSIMETER 2.3 i
017 126 6.3 14.8 +-
4; 2.2 12.6 +-
5; 2.5 018 220 4.6 13.9 +-
4; 2.1 11.8 +-
5; 2.4 i
019 231 5.3 15.9 +-
5; 2.4 13.7 +-
5; 2.6 020 211 1.6 13.3 +-
4; 2.0 11.2 +-
5; 2.3 022 258 1.5 14.2 +-
4; 2.1 12.1 +-
5; 2.4 023 271 1.2 14.4 +-
4; 2.2 12.3 +-
5; 2.5 024 297 1.3 13.4 +-
4l 2.0 11.3 +-
5; 2.3 i
i 025 318 1.5 12.7 +-
4; 1.9 10.6 +-
5; 2.2 026 341 3.2 14.0 +-
4 2.
11.9 +-
5; 2.4 5;
2.3 13.3 +-
5l 2.6 027 330 4.6 15.4 +-
028 358 3.2 13.4 +-
4; 2.0 11.2 +-
5 2.3 5 ;;
029 4
1.8 14.6 +-
4j 2.2 12.4 +-
2.5 030 19
.8 12.3 +-
4; 1.8 10.2 +-
5 ;' 2.2 l
031 69 1.4 13.2 +-
4; 2.0 11.1 +-
5; 2.3 1
032 78 2.5 11.6 +-
3; 1.7 9.5 +-
4; 2.1 033 85 2.2 11.9 +-
4; 1.8 9.8 +-
5; 2.1 034 38 1.7 14.6 +-
4' 2.2 12.5 +-
5; 2.5 035 24 1.9 MISSINGORDAllAGEDDOSIMETER 036 50 3
13.9 +-
4; 2.1 11.7 +-
5; 2.4 037 46 4.8 12.8 +-
4; 1.9 10.7 +-
5; 2.3 038 27 4
13.5 +-
4; 2.0 11.4 +-
5; 2.3 039 12 8.9 12.2 +-
4; 1.8 10.1 +-
5; 2.2 040 10 8.7 13.5 +-
4; 2.0 11.4 +-
5; 2.3 041 3
9.9 13.6 +-
4 l' 2.0 11.4 +-
5; 2.3 042 38 10.
MISSING OR DAf1 AGED DOSIMETER 043 46 9.1 14.2 +-
4; 2.1 12.1 +-
5; 2.4 044 73 6.5 12.5 +-
4; 1.9 10.4 +-
5; 2.2 045 79 6
15.5 +-
5; 2.3 13.3 +-
5; 2.6 046 278 20.
14.5 +-
4; 2.2 12.4 +-
5; 2.5 047 278 20.
15.2 +-
5; 2.3 13.0 +-
5; 2.6 TRANSIT D05E =
1.9
+-
.5 ; 1.3
4
.+,-m m+-
,,----.-w,e-v.--
.,e, ~.-
-,-e-v-w a,
-e-++-
-+--~,w--+
e---
OYSTER CREEK FOR THE PERIOD 821221-930412 TLD DIRECT RADI ATI0ii ENVIR0lif1EllTR!. f10NITORIriG RZDIUTH (dag.)
NET AVER. EXPOSURE PATE t IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348,75-11.25 (N)
Il.S +
.5 4
11.25-33,75 (NNE) 10.6 +
.7 3
33.75-56.25 (NE) ll.8 +
.8 4
56,25-78.75 (ENE) 10.3 +
.8 3
78.75-10l.25 (E) ll.B +- 2.5 2
10l.25-123.75(E5E) 13.4 +
.8 2
123,75-146.25(SE) 12.8 +
.S 4
145.25-168.75(55E) ll.8 +-.6 2
158.75-191.25(5) 12.4 +- 1.1 5
191. 25-2 l 3. 75 ( 55 H )
ll.7 +
.7 2
213,75-236.25(SW) 12.7 +- 1.3 2
238.25-258.75(H5Hi 12.1 +- 0.0 1
258.75-281.25(W) 12.3.t- 0.0 1
28l.25-303.75(WNH)
Il.3 +- 0.0 1
303.75-326.25(NH) 10.6 +- 0.0 1
326.25-348.75(NNH) 12.6 +- 1.0 2
DISTANCE (mi) FROM THE PERCTOP NET RVER.EXPOSUPE RATE
+ IN GROUP (mR/5td,0tr.) +-5t d. De v.
0-2 12.1 +- 1.0 16 2-5 ll.5 +- 1.1 12
>5 12.1 +- 1.3 12 UPHIND CONTROL ORTA 12.7 +
.4 2
Po'ISADES I DIRECT RADIATI0tl ENVIRONMENTAL MONITORIllG F
THE PERIOD 821122-S30412 112 DAYS F.cLD TIME 87 DAYS tlRC LOCATI0li GROSS 11ET EXPOSURE RATE STATI0tl AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 195 4.9 19.1 +-
.6 ;
2.9 110 t4ET' DATA 002 173 4.6 20.5 +-
.6 l 3.1 NO HET DATA 003 156 3.9 19.5 +-
.6 l 2.9 l10 t1ET DATA 004 132 4.6 18.8 +-
.6 l 2.3 110 flET DATA 005 118 3.3 23.3 +-
.7 l 3.5 N0 llET DATA x;
- x 2: Y :
t10 NET DATA 1 o
$ a :' + -
6' 9
ne:c
- i. s?
NU ti T Dn..A t
i U U,-
.30 ze it.e +-
.5, c.]
008
_r8 1.6 18.4 +-
.6 l 2.3 110 flET DATA 00!
200 0.9 20.0 +-
.6 l 3.0 N0 flET DATA 010 24 1.A
?A.4 +-
.6 l 3.1
!i0 NET DATA 011 107 1.6 20.1 +-
.6 l 3.0 t10 NET DATA 012 90 1.5 19.7 +-
.6 l 2.9 t10 NET DATA 013 65
'7 19.7 +-
.6 l 3.0 t10 t1ET DATA 014 51 1.9 19.4 +-
.6';
2.9 tl0 NET DATA 015 74 3.7 20.1 +-
.6 ;
3.0 N0 tlET DATA 016 90 3.6 18.5 +-
.6 l 2.3 NO NET DATA 017 98/
10.
18.0 +-
.5 l 2.7 fl0 tiET DATA 018 47 4.5 19.7 +-
.6 l 3.0 t10 tlET DATA 019 23 1.5 21.2 +-
.6 l 3.2 t10 f1ET DATA 020 32 4.8 21.4 +-
.6 ;
3.2 NO NET DATA 021 29 7.0 19.5 +-
.6 l 2.9 N0 t1ET DATA 022 99<
15.
19.9 +-
.6 l 3.0 NO NET DATA 023 98-18.
20.5 +-
.6 l 3.1 110 NET DATA 024 98/
15.
21.3 +-
.6~
3.2 NO NET DATR fl0 TRANSIT DOSE CALCULATED (TLD CONTROLS;MISSI!!G OR OTHERNISE ll0T COMPLET l
PALISADES FOR THE PERIOD 821222-830412 TLD DIRECT RADIATIGH ENVIRONMENTAL MONITORING RZIttuTH (dag. )
AVER. EXPOSURE RATE 4 IN GROUP (mP/Std.Otr.) t-Std.Dev.
4 J
348,75-ll.25 (N)
NO DATA +-NO DATR 0
11.25-33,75 (NNE) 16.6 +
.B 3
33.75-56.25 (NE) 15.7 +
.2 2
56.25-78.75 (ENE) 16.0 +
.2 2
78.75-101.25 (E) 15.0 +
.7 3
101.25-123.75(ESE) 17.4 +- 1.8 2
123.75-146.25(SE) 15.8 +
.9 2
1 145.25-168.75(55E) 15.3 4-
.1 2
168.75-191.25(5) 15.5 4-1.2 2
191. 25-2 L 3.75 (55N) 14.9 4-1.4 3
213.75-236.25(SW)
NO DATA &-NO DATR 0
4 238.25-258.75(USW)
No DATRe-NO DATR 0
258.75-281.25(H)
No DRTAt-N0 DATR 0
28 l.25-303. 75 ( WNH )
NO DATAt-NO DATA 0
303.75-326.25(NN)
NO DRTRt-NO DATR 0
326.25-348.75(NNN)
NO DRTA+-NO DATR 0
j i
l DISTANCE (mi) FROM THE PEACTOP ER EXPOSUP.E RR E 4 IN GROUP 0-2 15.B +
.7 9
L l
2-5 15.9 +- 1.4 1B l'
>5 15.1 +
.9 2
UPNIND CONTROL ORTA 16.5 +
.6 3
PALO VERDE TLD DIRECT RADIATI0t1 ENVIR0t1MEtITAL M0t1ITORING FOR THE PERIOD 821222-830411 111 DAYS FIELD TIME 89 DAYS ilRC LOCATI0t1 GROSS t1ET EXPOSURE RATE STATI0t1 AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(ai.)
+- Edm; Tot.
+- Rdm; Tot.
001 74 23.
19.2 +-
.6 ;
2.9 18.7 +-~
.7 ;
3.6 002 92 21.
19.8 +-
.6 l 3.0 19.3 +-
.8 ;
3.7 003 89 15.
19.6 +-
.6 ;
2.9 19.1 +-
7; 3.7 004 103 11.
19.8 +-
.6 l 3.0 19.3 +-
.8 ;
3.7 005 140 7.4 21.1 +-
.6 l 3.2 20.5 +-
.8 l 3.8 006 142 3.1 20.4 +-
.6 ;
3.1 19.9 +-
.8 l 3.8 007 162 2.6 19.9 +-
.6 ;
3.0 19.3 +-
.8 l 3.7 008 168 2.6 19.8 +-
.6 ;
3.0 19.2 +-
.7 ;
3.7 009 193 2.6 22.4 +-
.7 ;
3.4 21.9 +-
.8 ;
4.0 010 215 3.1 21.7 +-
.7';
3.3 21.2 +-
.8 ;
3.9 011 200 1.7 21.8 +-
.7 l 3.3 21.2 +-
.8 l 3.9 012 214 1.0 20.5 +-
. 6.';
3.1 20.0 +-
.8 ;
3.8 013 242 0.7 22.9 +-
.7 l 3.4 22.4 +-
.8 ;
4.1 014 263 0.6 21.3 +-
.6 ;
3.2 20.8 +-
.8 ;
3.9 015 295 0.6 19.8 +-
.6 ;
3.0 19.3 +-
.8 ;
3.7 016 325 1.0 90.5 +-
.6 l 3.1 20.0 +-
.8 l 3.8 01<
a47 1.3 21.2 +-
.6 l 3.2 20.7 +-
.8 l 3.9 018 0
2.4 21.1 +-
.6 ;
3.2 20.6 +-
.8 l 3.8 019 18 1.5 20.1 +-
.6 ;
3.0 19.5 +-
.8 ;
3.7 020 37 2.0 19.9 +-
.6 ;
3.0 19.3 +-
.8 ;
3.7 021 58 2.3 22.1 +-
.7 ;
3.3 21.5 +-
.8 ;
4.0 022 75 2.9 22.0 +-
7l 3.3 21.4 +-
.8 ;
4.0 023 93 4.4 22.0 +-
.7 ;
3.3 21.5 +-
.8 ;
4.0 024 101 3.3 20.4 +-
.6 ;
3.1 19.9 +-
.8 ;
3.8 025 346 2.9 20.8 +-
.6 ;
3.1 20.2 +-
.8 ;
3.8 026 334 4.3 23.6 +-
.7 ;
3.5 23.1 +-
.8 ;
4.2 027 333 7.9 22.4 +-
.7 ;
3.4 21.9 +-
.8 ;
4.0 028 0
7.0 23.4 +-
.7 ;
3.5 22.9 +-
.8 ;
4.1 029 9
4.2 MISSItlG OR Daf1 AGED DOSIMETER 030 27 3.6 23.4 +-
.7 ;
3.5 22.9 +-
.8 ;
4.1 031 49 3.5 24.1 +-
.7 ;
3.6 23.6 +-
.9 4.2 1.0 ;;
4.9 1
032 120 3.:
28.9 +-
.9' 4.3 28.5 +-
4 ; 2.1 TRAtlSIT DOSE =
.7
+-
.,-g.
m
i FALO VERDE FOR THE PERIOD 821222-830411 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING i
RZD1UTH (dag.)
NET AVER. EXPOSURE RATE
- IN GROUP l
(mR/Std.Qtr.) +-Std,Dev.
4 i
348.75-11.25 (N) 21.7 +- 1.6 2
j 11.25-33.75 (NNE) 21.2 +- 2.4 2
l 33.75-56.25 (NE) 21.4 +- 3.0 2
56.25-78.75 (ENE) 21.5 +
.1 2
78.75-101.25 (E) 20.7 +- 1.1 2
i 101.25-123.75(ESE) 23.9 +- 6.5 2
i 123.75-146.25(SE) 20.2 +
.5 2
14 5. 25-16 8. 75 ( 55 E )
19.3 +
.1 2
i j
168.75-191.25(5)
NO DRTR+-NO DRTR 0
191.25-213.75(55H) 21.5 +
.5 2
l 213.75-236.25(SW) 20.5 +
.9 2
l 236.25-250.75(W5W) 22.4 +- B.O 1
3 258.75-201.25(W) 20.8 +- B.O 1
- i 28t.25-303.75(HNW)
- 19. 3 +- B. O 1
303.75-326.25(NH) 20.0 +- B.O 1
326.25-348.75(NNN) 21.5 +- 1.3 4
DISTHNCE(mt) FR0tt THE REACTOP NET.RVER.EXPOSUPE RRTE
+ IN GROUP (mP/5td.Qtr.) + -5 t d. De v,
B-2 20.3 +- 1.0 9
l 2-5 2l.S +- 2.3 15 l
l
>5 2l.2 +- 1.6 4
l UPNIND CONTROL DRTR 19.0 +
.3 3
PEACH BOTTOM TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821230-830419 111 DAYS FIELD TIME 92 DAYS NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.
(dec.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 329 10.
16.5 +-
.5 ;
2.5 15.2 + '
.6 ;
3.0 002 31 10.
17.1 +-
.5 l 2.6 15.7 +-
.6 l 3.0 003 22 4.7 17.9 +-
.5 l 2.7 16.5 +-
.6 l 3.1 004 4
5 16.6 +-
.5 l 2.5 15.2 +-
.6 ;
3.0 005 345 4.1 15.4 +-
.5 ;
2.3 14.0 +-
.6 l 2.8 006 9
2.2 15.9 +-
.5 ;
2.4 14.6 +-
.6 l 2.9 e
tV.o +-
se 2
- a. n. 7 oo
-.s w.7 ig.a. +-
w.9 9
.i.
e I
-w w
V
.w q
w 008 5,5 2,. 9 17,.,1 + -
.5 l 2,. 6 15.7 +-
.6 ;
3.1 e
U s.-
003 4s c
le.e +-
.es ;
c.3 1.4 +.-
.D 3
010 63 1.7 18.6 +-
.6 l 2.3 17.2 +-
.7~;
3.2 011 97 2
16.9 +-
.5 l 2.5 15.5 +-
.6 l 3.0 012 107 2.3
- 13. 2 +-
.4 l 2.0 11.9 +-
.5 ;
2.6 O N c. '-
IQ.Cs t-
.D c.o
{j 1 #.0 rc 14.O t-
.4 SS C.
A S
t i
V v
014 86 4.6 17.4 +-
.5 l 2.6 16.0 +-
.6 ;,
3.1
~
015 110 4.3 18.2 +-
.5 ;
2.7 16.8 +-
.7 ;
3.2 016 130 4.7 10.7 +-
.3 l 1.6 9.5 +-
.5 ;
2.3 017 158 9
16.9 +-
.5 l 2.5 15.5 +-
.6 l 3.0 018 163 4.6 16.8 +-
.5 l 2.5 15.4 +-
.6 ;
3.0 019 184 3.9 17.1 +-
.5 l 2.6 15.7 +-
.6 l 3.0 020 203 4.9 17.7 +-
.5 l 2.7 16.3 +-
.6 l 3.1 021 197 1.3 15.5 +-
.5 l 2.3 14.2 +-
.6 ;
2.9 n_ L?
ico 1.7 to.i +-
.e e,
o.7 1 D. 7,
+_
.c, o.o e
V i
v V
- i V w 023 190 1.S 19.1 +-
.6 l 2.9 17.7 +-
.7 ;
3.3 e
n.94 999 1.a 17 c +-
.esq O.c 1D.9 +_
.D o,1 w
www v
iev w V w
g V
e e
nos 94 i v. c, + -
.e 9. =v in.Vo +-
.D o. a.-
c V q w
V q
V ww9 i.i a
ws w
0 i
d i
?A
?fQ 1.v 10 0 +-
. D" 9.?
17f.4
- 4. -
7 o.o wv wVv 4
AV V g
w 9 I
q V V i
i g
V (j #87 oCC j
{$. 6d 4
. D" 9.O 17.i i-7 o.Sc a.6 g
L V Ai A
.it LWV 028 323 1.8 16.9 +-
.5 l 2.5 15.5 +-
.6 l 3.0 029 286 3.6 21.4 +-
.6 l 3.2 19.9 +-
.7 ;
3.6 030 264 4
19.5 +-
.6 l 2.9 18.0 +-
.7 ;
3.3 9,3.,z.
19.3, +-
.6 l 2,. 9, 17,. 8. +-
.7,l 3,. 3 03,1 262
.9 1,r.., + -
.c
. q.-ec 1D.U, t-V.,1 0.3:
.D c.D s.
o.,
- n. :e
..4
- 14. ps +-
4 gVV cas 7.a 1nc.c t-
.D g
2 c.
u 034 319 4.9 16.1 +-
.5 ;
2.4 14.8 +-
.6 ;
2.9 035 151
.7 15.7 +-
.5~;
2.4 14.4 +-
.6 l 2.9 036 148 16.
13.4 +-
.4 ;
2.0 12.1 +-
.5 ;
2.6 037 148 16.
MISSING OR DAMAGED DOSIMETER A38 148 16.
MISSING OR DAMAGED DOSIMETER TRANSIT DOSE =
1.0
+-
.4 ; 1.8 i
i
PEACH BOTT0ii FOR THE PERIOD 821230-830419 TLL LIRE 0T F ALI ATIO!4 EtiVIR0!inEtiTAL !10tilTORI!!G RZIflu TH (dag.)
NET AVER. EXPOSURE PATE
- IN GROUP (mR/Std.Otr.) t-Std.Dev.
348.75-It.25 (N) 14.9 +
.4 2
11.25-33.75 (NNE) 16.4 +-.6 3
33.75-56.25 (NE) 15.6 +-.2 2
56.25-78.75 (ENE) 15.3 +- 2.6 2
78.75-10l.25 (E) 15.8 +
.3 2
10l.25-123.75(ESE) 14.4 +- 3.5 2
123.75-146.25(SE?
9.5 +- 0.0 1
145.25-168.75(55El 15.1 +
.6 3
158.75-191.25(5) 15.7 +- 1.0 3
191.25-213. 75 ( 55 H )
15.3 +- 1.5 2
213.75-236.25(SH')
14.4 +- 2.5 2
236 25-258.75(H5W) 15.6 t-
.5 2
258.75-281.25(H) 17.7 +-.4 3
28l.25-303.75(HNH) 18.5 +- 2.0 2
303.75-326.25(NH) 15.1 +
.5 2
326,25-348.75(NNH) 14.6 +
.8 2
DISTANCE (mi) FROM THE PEACTOP NET RVER.EXPOSUPE RATE
+ IN GROUP
( n>P/ 5t d. 0 t r. ) +-Std.Dev.
D-2 16.2 +- 1.1 11 2-5 15.3 +- 2.2 19
>5 15.4 +- 1.8 5
UPNIND CONTROL DATA 12.1 +- 0.0 1
PERRY TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 830103-930418 104 DAYS FIELD TIME 69 DAYS HRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.
(dec.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 72 5.0 15.4 +-
.5 ;
2.3 10.6 + '
.8 ;
4.0 003 88 5.5 15.8 +-
.5 l 2.4 11.1 +-
.8 l 4.0 004 112 6.0 18.1 +-
.5 l 2.7 14.1 +-
.9 l 4.4 005 130 4.0 MISSING OR DAf1 AGED DOSIMETER 006 155 5.0 22.4 +-
.7 ;
3.4 19.7 +-
1.0 ;
5.1 007 178 5.2 17.0 +-
.5 l 2.5 12.6 +-
.9 l 4.2 008 205 4.6 16.6 +-
.5 ;
2.5 12.1 +-
.8 l 4.2 009 220 5.2 15.5 +-
.5 l 2.3 10.7 +-
.8 ;
4.0 010 225 7.4 17.0 +-
.5 l 2.6 12.7 +-
.9 l 4.0 011 240 5.8 17.6 +-
.5 l 2.6 13.4 +-
.9 l 4.3 012 225 19.
15.7 +-
.5 l 2.3 10.9 +-
.8 l 4.0 013 225 19.
14.3 +-
.4 l 2.1 9.2 +-
.8';
3.8 014 212 12.
19.4 +-
.6 l 2.9 15.8 +-
.9 l 4.6 015 248 1.4 15.1 +-
.5 ;
2.3 10.2 +-
.8 l 3.9 016 225 0.8 15.1 +-
.5 ;
2.3 10.2 +-
.8 ;
3.9 017 On5 n.7 14.4 +-
.4 ;
2.2 9.2 +-
.8 ;
3.8 018 180 0.8 14.8 +-
.4 ;
2.2 9.8 +-
.8 l 3.9 019 152 1.8 15.3 +-
.5 l 2.3 10.5 +-
.8 l 4.0 020 123 1.6 14.5 +-
.4 l 2.2 9.4 +-
.8 l 3.9 021 105 1.4 15.1 +-
.5 l 2.3 10.2 +-
.8 l 3.9 000 A5 1.2 16.3 +-
.5 ;
2.4 11.8 +-
.8 ;
4.1 023 65 1.4 15.6 +-
.5 l 2.3 10.9 +-
.8 ;
4.0 024 40 0.6 15.3 +-
.5 l 2.3 10.4 +-
.8 l 4.0 025 40 0.6 15.0 +-
.4 l 2.2 10.0 +-
.8 ;
3.9 026 189 0.8 15.0 +-
.5 l 2.3 10.1 +-
.8 l 3.9 027 175 2.5 15.1 +-
.5 l 2.3 10.2 +-
.R l 3.9
.4 ; 2.0 TRANSIT DOSE =
?.3 t-i
PERRY FOR THE PERIOD 830105-830418 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING i
RZIMUTH (dag. )
NET AVER. EXPOSUPE RATE
- IN GROUP (mR/Std.Otr.) t-Std.Dev.
1 348.75-ll.25 (N)
NO DRTA+-NO DATR 0
11.25-33.75 (NNE)
NO DATA +-NO DATR 0
33.75-56.25 (NE) 10.2 +
.3 2
56.25-78.75 (ENE) 10.7 +
.2 2
78.75-101.25 (E) 11.4 +
.5 2
i
^
10l.25-123.75(ESE)
It.2 +- 2.5 3
123. 75-14 6. 25 ( S E )
NO DRTA+-NO DATR 0
14 5.25-159. 75 ( 55E )
15.1 4-5.5 2
ISO.75-191.25(5) 10.7 +- 1.3 4
19t.25-2l3.75(55N) 10.7 +- 2.0 2
213.75-236.25(SW)
Il.2 +- 1.3 9
i 23 6.25-258. 75 (145 W )
Il.B +- 2.3 2
25 8.75-201.25 ( U)
NO DRTRt-NO DATR 0
28 L.25-303.75 (64NW)
NO DRTAt-NO DATR 0
303.75-326.25(NH)
NO DRTRt-N0 DATR 0
326.25-348.75(NNN)
NO DRTR+-NO DATR 0
l DISTANCE (mi) F ROM THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP (mR/5td.Qtr.) +-5t d. De v.
l B-2 10.2 +
.7 11 2-5 12.5 t-4.1 5
>5 12.4 +-- 1. 3 6
UPHIND CONTROL DATA 12.0 +- 3.4 3
PILGRIM TLD DIRECT RADIATI0tl ENVIRONMEllTAL MONITORIliG FOR THE PERIOD 821229-830420 113 DAYS FIELD TIME 100 DAYS tlRC LOCATI0t1 GROSS tlET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(deo.)
Ou i. )
+- Rdm; Tot.
+- Rdm; Tot.
001 288
.1 54.0 +-
1.6 ;
8.1 46.1 +-' 1.5 ;
7.5 002 310
.2 17.4 +-
.5 ;
2.6 13.2 +-
.6 ;
2.9 005 289
.7 17.3 +-
.5 ;
2.6 13.1 +-
.6 l 2.9 006 261 1.7 14.6 +-
.4 2.2 10.6 +-
.6 l 2.6
.5 ;
007 270
.5 17.6 +-
2.6 13.3 +-
.6 ;
2.9 008 247
.3 16.5 +-
.5 l 2.5 12.3 +-
.6 l 2.8 009 224
.3 15.9 +-
.5 l 2.4 11.8 +-
.6 ;
2.7 010 205
.3 25.3 +-
.8 l 3.3 20.3 +-
.8 ;
3.8 012 159
.4 19.2 +-
.6 l 2.9 14.8 +-
.7 l 3.1 013 146
.7 13.7 t-
.4 l 2.0 9.8 +-
.6 l 2.5 014 155 1
14.7 +-
.4 l 2.2 10.8 +-
.6 l 2.6 016 136 1.3 15.3 +-
.5 l 2.3 11.3 +-
.6~;
2.7 018 212
.8 18.0 +-
.5 ;
2.7 13.7 +-
.6 l 3.0 019 232 1
12.7 +-
.4' 1.9 8.9 +-
.5 l 2.4 021 256 1.6 14.6 +-
.4 l 2.2 10.6 +-
.6 ;
2.6 022 130 2.5 14.6 +-
.4 l 2.2 10.6 +-
.6 l 2.6 023 146 3.4 12.5 +-
.4 l 1.9 8.8 +-
.5 l 2.4 025 168 1.5 13.5 t-
.4 l 2.0 9.6 +-
.5 l 2.5 026 180 1.3 12.5 +-
.4 l 1.9 8.7 +-
.5 l 2.4 027 231 1.8 13.7 +-
.4l 2.0 9.8 +-
.6 ;
2.5 030 153 2.2 14.6 +-
.4 ;
2.2 1U.6 +-
.t 2.6 031 179 2.5 13.6 +-
.4 ;
2.0 9.7 +-
.5 l 2.5 032 217 2.6 12.8 +-
.4 ;
1.9 9.0 +-
.5 l 2.4 03:
234 2.5 13.8 +-
.4 l 2.1 10.0 +-
.6 l 2.5 037 264 4.2 15.6 +-
.5 l 2.3 11.5 +-
.6 l 2.7 038 152 3.5 MISSIllG OR DAf1 AGED DOSIMETER 039 155 5.3 11.3 +-
.3 ;
1.c r.< +-
.5 ;
2.3 040 272 4.6 13.8 +-
.4 l 2.1 9.9 +-
.6 ;
2.5 042 281 4.6 13.0 +-
.4 l 1.9 9.2 +-
.5 ;
2.4 043 291 5.6 15.1 +-
.5 ;
2.3 11.1 +-
.6 t 2.7 047 301 26.
15.3 t-
.5 ;
2.3 11.3 +-
.6 l 2.7 048 301 26.
14.9 +-
.4 ;
2.2 10.9 +-
.6 l 2.6 049 301 26.
14.4 +-
.4 ;
2.2 10.4 +-
.6 l 2.6 TRANSIT DOSE =
2.7
+-
.5 ; 1.9
~
~
Cot 1HENTS:
STATION l I5 ON LICENSEE PROPERTY (PILGRIN OVERLOOK RRER).
ACCEBB I5 CONTROLLED I
i
PILGRIM FOR THE PERIOD 821229-830420 i
TLD DIRECT RADIATION ENVIR0!iMENTAL MONITORING RZIMUTH (deg.)
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Otr.) t-Std.Dev.
348.75-11.25 (N)
NO DRTA+-NO DATR 0
11.25-33.75 (NNE)
NO DATA +-NO DATR 0
l 33.75-56.25 (NE)
NO DATA +-NO DATR 0
56.25-78.75 (ENE)
NO DATA +-N0 DATA 0
78.75-10l.25 (E)
NO DATA +-NO DATR 0
2 10l.25-123.75(ESE)
NO DRTA+-NO DATR 0
123.75-146.25(SE) 10.1 +- 1.1 4
i 145.25-158.75(55E)
- 10. 7 +- 2. 5 5
,i j
158.75-191.25(5) 9.2 +
.7 2
19 t.25-213.75 (55W) 17.0 +- 4.7 2
213.75-236.25(SN) 9.9 +- 1.2 5
238.25-258.75(uSW)
Il.5 +- 1.2 2
250.75-281.25(u) 10.9 +- 1.6 5
281.25-303.75(uNH) 23.5 +- 19.7 3
303.75-328.25(NH) 13.2 +- 2.0 1
326.25-348.75(NNN)
No DATA +-NO DATR 0
l DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE 4 IN GROUP j
(mR/Std Qtr.)
+-5t d. De v.
B-2 13.8 +- B.5 1B 2-5
- 9. 9 +
. 9 9
>5 9.4 +- 2.5 2
UPNIND CONTROL DATA 10.9 +
.4 3
PRAIRTE ISLAND TLD DIRECT RADIATION ENVIRONMENTAL MONITORIt1G FOR THE PERIOD 821222-830412 112 DAYS FlELD TIME 90 DAYS HRC LOCATION GROSS HET EXPOSURE nniE STATION AZIMUTH /DIST EXPOSURE >:mR) mR/Std.0tr.
(dea.)
Oli. )
+- Rdm; Tot.
+- Rdm; Tot.
001 312 17.
21.7 +-
6; 3.2 18.5 +-~
.9 ;
4.1 002 310 15.
,19.9 +-
6l 3.A 16.8 +-
.8 l 3.9 aV.
-e 6
004 308 5.5 MISSING OR DAf1 AGED DOSIMETER 4.a c_.o t_
o, o.i 1 -(. i +_
.no.
n_ n. o
.o 1 a.
te.
V V
005 297 4.1 17.8 +-
5; 2.7 14.7 +-
.8 ;
3.6 006 287 1.3 19.4 +-
6l 2.3 16.2 +-
.8 l 3.8 007 313 0.8 18.9 +-
6l 2.3 15.7 +-
.8 l 3.7 008 244 0.5 19.7 +-
6l 2.9 16.5 +-
.8 l 3.8
. - e e
n_ n_ o.
lo.,w a_. e-91.mo +._
o, o. _9 t o. w> +-
.o,
- 4. n.
w v
V 010 155 0.5 20.5 +-
6; 3.1 17.3 +-
.8 l 3.9 011 129 1.6 18.4 +-
6l 2.8 15.2 +-
.8 l 3.7 012 153 1.4 19.2 +-
6; 2.9 16.0 +-
.8 ;
3.8 019:
?17 0.6 18.7 +-
6l 2.8 15.6 +-
.8 l 3.7 014 178 0.8 19.8 +-
6; 3.0 16.7 +-
.8';
3.8 015 272 1.9 19.0 t-6; 2.8 15.8 +-
.8 l 3.8 016 262 4.6 19.8 +-
6; 3.0 16.6 +-
.8';
3.8 017 250 4.3 20.4 +-
6; 3.1 17.3 +-
.8 l 3.9 018 225 4.1 18.8 +-
6l 2.8 15.6 +-
.8 l 3.7 019 233 6.7 17.6 +-
5l 2.6 14.5 +-
.8 l 3.6 020 200 4.9 20.7 +-
6; 3.1 17.5 +-
.8 l 3.9 n?!
187 4.7 21.0 +-
6; 3.2 17.9 +-
.8 ;
4.0 1
It.t- +-
.no; 4
-i n -
it n,
10 4.4 1q - +-
o, o.0 n.on o
te.o -
.o i, 3.o ch o.V i M.j 4.7 t o. ej +-
df o
n n.ot Ad V T_
V V
1 e
. V,
L LV 024 13,1 6.6 19.8 +-
6l 3.0 16.7 +-
.8 ;
3.8 n. =s lno.e +-
.o
,u Ur=s 11, 4.y it.no +-
n s -
c.
n.eos c
. o,
V 026 88 1.9 19.2 +-
6l 2.9 16.1 +-
.8 l 3.8 027 69 1.8 19.6 +-
6; 2.9 16.4 +-
.8 ;
3.8 028 47 1.6 18.7 +-
6l 2.8 15.6 +-
.8 ;
3.7 029 19 1.5 19.7 +-
6l 3.0 16.6 +-
.8 l 3.8 030 356 1.9 18.7 +-
6; 2.8 15.5 +-
.8 ;
3.7 031 346 2.4 19.3 +-
6l 2.9 16.1 +-
.8 ;
3.8 032 340 3.8 21.3 +-
6l 3.2 18.1 +-
.9 l 4.0 033 8
4.6 20.6 +-
6l 3.1 17.4 +-
.8 l 3.9 no--.
17 4. :,
?3.ea +-
7a o. =s o n...a +. _
.o, n.o e
e v
035 45 11 00.4 +-
6; 3.1 17.2 +-
.8 l 3.9 036 48 4.7 19.3 +-
6l 2.9 16.1 +-
.8 l 3.8 4 a
-a w.o 1D.s +_
.oe o.o no c1 4.w to.i +_
D o
e v
V 9 V V vl v
v l
038 86 4.9 20.1 +-
6l 3.0 17.0 +-
.8 ;
3.9 039 107 9.1 16.4 +-
5l 2.5 13.3 +-
.8~;
3.5 040 til 3.7 19.4 +-
6l 2.9 16.2 +-
.8 l 3.8 TRANSIT LOSE =
3.1
+-
.6 ; 2.4 n.
- - ~
PRRIRIE ISLAND 4
FOR THE PERIOD 821222-930412 i
TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dag.)
NET AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qir.) t-Std.Dev.
4 I
348.75-ll.25 (N) 16.5 +- 1.3 2
I l
11.25-33.75 (NNE) 18.4 +- 2.7 2
33,75-56.25 (NE) 16.3 +
.8 3
56.25-78.75 (ENE) 16.5 +
.1 2
78.75-10L.25 (E) 16.5 +
.6 2
10l.25-123.75(ESE) 14.4 +- 1.6 3
123.75-146.25(SE) 15.9 +-.7 3
14 5.25-158. 75 l 55 E )
15.5 +
.7 3
158.75-191.25(5) 17.3 4-
.8 2
I 13l.25-213.75(55N) 17.8 +
.5 2
213.75-236.25(SW) 15.2 +
.7 3
236.25-258.75(W5W) 16.9 +
.5 2
258.75-281.25(W) 16.2 +
.B 2
281.25-303.75(WNU) 15.4 +- 1.1 2
303.75-328.25(NH) 15.7 +- 0.0 1
4 326.25-348.75(NNN) 17.1 +- 1.4 2
i l
DISTANCE (mt) FROM THE. REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP
( niR/ St d. Q t r. ) +-5td.Dev.
(
B-2 16.2 +
.8 15 l
2-5 16.7 +- 1.5 17
>5 15.4 +--1.9 4
UPNIND CONTROL ORTA 17.6 +
.5 3
1
I f
QUAD CITIES TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821222-830405 105 DAYS FIELD TIME 78 DAYS HRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
00,1 7-0.7 14,.6 +-
.4 ;
2.2 11 6 + '
.8 ;
3.5 n e
.o r.c +-
.e n -
n_gt 1,r 3.
3 n
t.o
- 14. t. +-
.o.
.2. v d,
003 45 1.7 16.2 +-
.5 l 2.4 13.4 +-
.8 l 3.7 004 65 1.1 17.5 +-
.5 l 2.6 15.0 +-
.8 l 3.9 005 90 0.8 16.3 +-
.5 l 2.4 13.6 +-
.8 l 3.7 006 136 1.1 17.1 +-
.5 l 2.6 14.5 +-
.8-3.8 007 175 1.8 18.7 +-
.6 l 2.8 16.4 t-
.9 ;
4.1 A. A_ R_
157 0.s to.a +.-
6 o..a.
i s_. 5_ + -
4, 4'.1 vi v
w 009 186 3.1 17.5 +-
.5 l 2.6 15.0 +-
.8 l 3.9 010 188 7.7 13.4 +-
.6 l 2.8 16.0 +-
.9 l 4.0 011 156 4.2 14.5 +-
.4 l 2.2 11.5 +-
.8~;
3.5 012 142 4.8 17.6 +-
.5 ;
2.6 15.0 +-
.8 ;
3.9
+-
o '
1 0 0 l ' 4 +-
' =
l'Id f.5 lb 0 +-
.5 !
I'.I 1*5l2+-
.5 !
5.'7 A10 I
1 01 015 86 2.8 19.2 +-
.6 l 2.9 16.9 +-
.9 l 4.1 016 62 4.4 18.4 +-
.6 l 2.8 16.0 +-
.9' 4.0 017 48 6.1 18.0 +-
.5 l 2.7 15.5 +-
.8 l 3.9 018 39 8.8 18.3 +-
.5 l 2.7 15.8 +-
.8 l 4.0 019 36 4.7 17.0 +-
.5';
2.5 14.3 +-
.0 l 3.8 020 16 4.3 13.4 +-
.4 l 2.0 10.2 +-
.7 l 3.4 021 358 4.2 18.1 +-
.5 l 2.T 15.7 +-
.8 l 4.0-1 022 336 4.1 18.4 +-
.6 l 2.8 16.0 +-
.9 l 4.0 023 337 5.7 18.5 +-
.6 l 2.3 16.1 +-
.9 l 4.0 024 317 4.4 17.7 +-
.5 l 2.7 15.2 +-
.8 ;
3.9 025 295 4.1 16.6 +-
.5 ;
2.5 13.9 +-
.8 ;
3.8 026 282 6.9 15.7 +-
.5';
2.3 12.8 +-
.8 l 3.6 027 265 4.3 16.7 +-
.5 l 2.5 14.0 +-
.8 l 3.8 028 253 4.0 16.7 +-
.5 l 2.5 14.0 t-
.8 l 3.8 ic.o +_
o a e
n_o; a.cc o.o 17.o +_
.s, o. :1 o.o d V
.V V
e we Vv w
v 6
6-w 030 335 1.9 15.2 +-
.5 ;
2.7 15.7 +-
.8 l 4.0 1
2.6 18.8 +-
.6 ;
2.8 16.4 +-
.9 l 4.1 031 3,o. 7 c.e 11.o +_
.o e,
i..,
i.c.
+_
y e
- a. t.2 a
o 4
c 3.1 s
c s
- v 033 266 2.0 19.0 +-
.6 ';
2.8 16.6 +-
.9 ;
034 248 2.2 MISSING OR DAMAGED D03IMETER 4.1 or o,o n g ig v +_
1, o +_
o.
o, e.
=
p$55 Ibd b4 1N
+-
.$ ! I'I ib5 +-
'.5 !
5.9 037 194 8.3 MISSING OR DAf1 AGED D0?INETER
~
17.o y_
.Cd y
w.
} '[
R.Q 4_
Q g.Q (joo
))4 4.[
4 4
af V J Y
.V V
s w
.4 2.2 11.7 +-
.8 ;
3.5 039 301 15, 14.7 +-
.5 ;;
2.5 14.0 t-
.8 l 3.8 040 301 15.
16.7 +-
041 301 15.
18.8 t-
.6 ;
2.8 16.4 +-
.9 l 4.1 TRANSIT DOSE =
4.5
+-
.5 ; 2.1 4
1
~
~
k,
QUAD CITIES FOP THE FERIOD 821222-930405 TLD DIEECT RADI AIION ENVIPONt1 ENTAL f:0NITORItiG RZIrluTH (dag.)
NET AVER. EXFOSURE PATE 4 IN GROUP (mR/Std.Ctr.) t-Std.Dev.
348.75-il.25 (N) 14.2 +- 2.3 3
11.25-33.75 (NNE) 12.4 +- 3.1 2
33.75-56.25 (NE) 14.8 +- 1.1 4
56.25-78.75 (ENE) 15.5 +
.7 2
78.75-10l.25 (E) 15.2 +- 2.3 2
10l.25-123.75(ESE) 13.4
+.4 2
123.75-146.25(SE) 14.7 +
.4 2
14 6. 25-16 8. 7 5 ( 55E )
14.0 4-3.5 2
168.75-191.25(5) 15.8 4-
.7 3
19l.25-2l3.75(55H) 14.8 +- 0.0 1
213.75-236.25(SW) 14.5 +- 1.1 2
236.25-258.75(W5W) 14.0 +- 0.0 1
258.75-201.25(W) 15.3 +- 1.9 2
28l.25-303.75(WNW)
Il.5 +- 3.3 3
303.75-328.25(NH) 15.8 +
.9 2
326,25-348,75(NNN) 15.9 +
.2 3
DISTANCE (mi) FR0t1 THE REACTOP NET RVER.EXPOSUPE RATE
+ IN GROUP f r P/5td. 0t r. ) +-5td.Dev.
D-2 14.6 +- 1.6 11 2-5 14.2 +- 2.2 20
>5 15.2 +- 1.4 5
UPHIND CONTROL DATA 14.0 +- 2.4 3
I
i RAtlCHO SECO TLD DIRECT RADIATI0tl EtiVIR0tlHEllTAL MONITORIllG l
FOR THE PERIOD 821222-830527 157 DAYS FIELD TIME 92 DAYS tlRC LOCATI0tl GROSS tlET EXPOSURE RATE STATI0tl AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
j (dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 280 16.
31.8 +-
1.0 ;
4.8 21.5 + ~ 1.3 ;
6.1 002 239 12.
32.6 +-
1.0 l 4.9 22.3 +-
1.3 ;
6.2 003 213 16, 24.0 +-
.7 !
3.6 13.9 +-
1.1 ;
5.3 004 149 9.9 35.1 t-1.1 ;
5.3 24.7 +-
1.3 ;
6.5 005 108 8.2 36.6 +-
1.1 ;
5.5 26.2 +-
1.4 ;
6.6 006 86 10.
30.7 +-
.9 l 4.6 20.4 +-
1.2 ;
6.0 007 83 9.7 28.6 +-
.9 ;
4.3 18.3 +-
1.2 ;
5.7 008 3r c.1 32.0 +-
1.0 ;
4.8 21.7 +-
1.3 ;
6.1 009 65 0.8 32.0 +-
1.0 ;
4.8 21.7 +-
1.3 ;
6.1 010 43 0.c 31.3 +-
.9 ;
4.7 21.0 +-
1.3l 6.0 011 92 0.?
10.0 +-
.9 ;
4.5 19.7 +-
1.2 ;
5.9 012 131 1.6 29.6 +-
.9 ;
4.4 19.3 +-
1.2 l 9.8 013 358 0.6 33.2 +-
1.0 l 5.0 22.8 +-
1.3 ;
6.2 014 323 0.7 30.2 +-
.9 ;
4.5 19.9 +-
1.2 ;
5.9 015 151 0.7 29.5 +-
.9 ;
4.4 19.3 +-
1.2 ;
5.8 016 219 0.9 30.1 +-
.9 l 4.5 19.8 +-
1.2 l 5.9 017 245 1.5 MISSING OR DAf1 AGED DOSIMETER
.9 4.5 19.9 +-
1.2 ;
5.9 018 254 2.3 30.2 +-
1.0 ;;
5.2 24.6 +-
1.3 ;
6.5 019 323 7.0 35.0 +-
020 309 6.3 31.5 +-
.9 ;
4.7 21.2 +-
1.3 ;
6.1 1.0l
.9 4.7 21.2 +-
1.3 ;
6.1 021 279 5.7 31.5 +-
4.9 21.6 +-
1.3 l 6.1 022 244 6.4 31.9 +-
.9 4.7 21.1 +-
1.3 ;
6.0 023 217 4.6 31.4 +-
1.0 ;;
4.9 22.2 +-
1.3 ;
6.2 024 350 11.
32.5 +-
025 318 17.
32.4 +-
1.0 ;
4.9 22.1 +-
1.3 ;
6.2 026 311 22.
32.2 +-
1.0 l 4.8 21.9 +-
1.3 ;
6.1 027 306 27, 32.0 +-
1.0 l 4.3 21.7 +-
1.3 ;
6.1 028 306 27.
30.7 +-
.9 l 4.6 20.4 +-
1.2 ;
6.0 029 306 27.
30.6 +-
.9 l 4.6 20.3 +-
1.2 ;
6.0 030 306 27.
MISSIllG OR DAMAGED DOSIMETER TRAtlSIT DOSE =
9.8
+-
9 ; 4.0 i
W
RANCHO SEC0 FOR THE PERIOD 821222-830527 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIt tuTH (dag.)
NET AVER. EXPOSURE RATE
- IN GMOUP (mR/Std.Otr.) t-Std.Dev.
348.75-ll.25 (N) 22.5 +
.4 2
11.25-33.75 (NNE)
NO DRTA+-NO DATR 0
33.75-56.25 (NE) 2l.3 +
.5 2
56.25-78.75 (ENE) 2l.7 +- 0.0 1
78.75-10l.25 (E) 19.5 +- 1.1 3
10l.25-123.75(ESE) 26.2 +- B.O 1
123. 75 - 14 6. 25 ( S E.1 19.3 +- 0.0 1
14 5.25-168. 75 ( 55 E )
22.0 +- 3.8 2
168.75-191.25(5)
NO DATR&-NO DRTR 0
19 t. 25-2 l 3.75 ( 55N) 13.9 +- B.O 1
213.75-236.25(SW)
- 20. 4 +
. 9 2
i 236.25-258.75(W5H) 2l.3 +- 1.2 3
258.75-281.25(H) 21.2 +- B.O 1
28t.25-303.75(UNH) 2l.5 +- 2.0 1
j 303.75-326.25(NH) 2l.6 +- 1.9 5
326.25-348.75(NNN)
NO DRTA+-NO DATR 0
DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE 4 IN GROUP (mR/5td.Qtr.)
+-5t d. De v.
0-2
- 20. 4 +- 1. 3 8
2-5 20.5 +
.B 2
>5 21.5 +- 2.9 15 UPNIND CONTROL ORTA 2l.3 +
.8 3
i RCEINSON TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821223-830418 117 DAYS FIELD TIME 92 DAYS NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(daa.)
(ni.)
+- Rda; Tot.
+- Rdm; Tot.
001 191 0.2 17.0 +-
.5 ;
2.5 15.1 +-'
.7 ;
3.3 002 151 1.9 21.2 +-
.6 l 3.2 19.3 +-
.8 l 3.8 003 134 2.0 22.2 +-
.7 l 3.3 20.3 +-
.8 ;
004 119 1.9 MISSING OR DAMAGED DOSIMETER 3.9 4
005 89 2.1 22.8 +-
.7 ;
3.4 20.8 +-
.8 ;
3.9 006 65 1.0 20.9 +-
.6 :
3.1' 19.0 +-
.8l 3.7 007 46 1.8 21.7 +-
.7 l 3.3 19.8 +-
.8 ;
3.8 008 27 1.3 MISSING OR DAMAGED DOSIMETER 009 22 3.5 MISSING OR DAMAGID DOSIMETER 010 0
5.0 21.6 +-
.6 ;
- 3. 2 19.7 +-
.8 ;
3.8 011 51 4.8 23.5 +-
.7 l 3.5 21.5 +-
.8 l 4.0 012 67 4.1 19.4 +-
.6 l 2.3 17.5 +-
.7 l 3.5 013 87 4.5 17.7 +-
.5 ;
2.7 15.8 +-
.7 ;
3.3 i
014 109 5.n
?0.8 +-
.6 ;
3.1 18.9 +-
.8 l 3.7 I
015 118 4.8 19.5 +-
.6 ;
2.9 17.6 +-
.7 ;
3.5 016 138 5.3 14.1 +-
.4 l 2.1 12.3 +-
.6 l 2.9 017 115 17.
19.8 +-
.6 l 3.0 17.9 +-
.7 l 3.6 018 199 12, 20.6 +-
.6 l 3.1 18.7 +-
.8 l 3.7 019 208 4.9 23.3 +-
.7 ;
3.5 21.3 +-
.8 l 4.0 020 225 4.0 23.2 +-
.7 l 3.5 21.2 +-
.8';
4.0 021 178
- 4. 6, 18.9 +-
.6 l 2.8 17.0 +-
.7,l 3.5 4,0
-e e
cJ L L i c,i 2
c..e +-
.D o.a.
t -[. 2<
i_
.(
q 3.D v
s.t 6
V g
V v
023 181 2.3 20.2 +-
.6 l 3.0 18.2 +-
.7 l 3.6 024 194 2.0 20.8 +-
.6 ;
3.1 18.8 +-
.8 ;
3.7 025 228 2.1 20.5 t-
.6 ;
3.1 18.5 +-
.8 ;
3.7 026 245 1.5 13.9 +-
.4 l 2.1 12.1 +-
.6 l 2.9 027 273 1.8 19.2 +-
.6 ;
2.9 17.3 +-
.7 l 3.5 028 287 2.0 18.0 +-
.5 ;
2.7 16.1 +-
.7 ;
3.4 029 311 1.6 19.9 +-
.6 l 3.0 18.0 +-
.7 ;
3.6 030 334 1.9 MISSING OR DAMAGED DOSIMETER 031 353 1.8 MISSING OR DAMAGED D9SIMETER 032 333 4.0 20.2 +-
.6 ;
3.0 18.3 +-
.7 ;
3.6 033 318 4.7 21.6 +-
.6 l 3.2 19.7 +-
.8 ;
3.8 034 310 6.9 20.0 +-
.6 l 3.0 18.0 +-
.7 ;
3.6 035 295 4.0 23.6 +-
.7 l 3.5 21.6 +-
.8 ;
4.1 036 269 4.8 20.2 +-
.6 ;
3.0 18.2 +-
.7 l 3.6 037 252 4.c 0' 1. 4 + -
.6 l 3.2 19.5 +-
.8 ;
3.8 038 274 10.
18.4 +-
.6 l 2.8 16.5 +-
.7 ;
3.4 039 286 15, 19.2 +-
.6 l 2.9 17.3 +-
.7 l 3.5 040 289 16.
19.1 +-
.6 ;
2.9 17.2 +-
.7 l 3.5 l
041 291 17.
18.8 +-
.6 l 2.8 16.9 +-
.7 ;
3.5
.5 ; 2.1 TRANSIT DOSE =
1.5
+-
\\
ROBIll50tl FOR THE PERIOD 821223-830418 TLD DIRECT RADIATIO!i ENVIRONMENTAL MONITORING RZD1UTH (dag.)
NET RVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-ll.25 (N) 19.7 +- 0.0 1
11.25-33.75 (NNE)
NO DRTA+-NO DATR 0
33.75-56.25 (NE) 20.6 +- 1.2 2
56.25-78.75 (ENE) 18.2 +- 1.1 2
78 75-10l.25 (E) 18.3 +- 3.5 2
10l.25-123.75(ESE) 18.1 +
.7 3
123.75-146.25(SE) 16.3 +- 5.6 2
145.25-168.75(55E) 18.5 +- 1 0 2
168.75-191.25(5) 15.8 +- 1.5 3
19l.25-2l3.75(55H) 19.5 +- 1.5 3
213.75-236.25(SH) 19.9 +- 1.9 2
238.25-258.75(HSW) 15.8 +- 5.2 2
258.75-281.25(u) 17.4 +
.9 3
28l.25-303.75(UNW) 18.9 +- 3.9 2
(
303.75-326.25(NHi 18.6 +
.9 3
326.25-349.75(NNN) 18.3 +- 0.0 1
DISTANCE (mi) FROM THE PEACTOR NET RVER. EXPOSURE RATE
+ I N GRO UP (mR/5td.0tr.)
+-5t d. De v.
B-2 17.6 +- 2.5 la 2-5 19.1 +- 1.7 18
>5 16.7 +- 2.6 5
UPHIND CONTROL DATA 17.1 +
.2 3
ST.LUCIE TLD DIRECT RADIATIO!1 ENVIRONMEllTAL MONITORIt1G FOR THE PERIOD 821217-530415 120 DAYS FIELD TIME 102 DAYS tlRC LOCATI0t1 GROSS tiET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
t10 NET; Tot.
+- Rdm DATA 001 20' O.3 13.2 +-
.4 ;
2.0 002 45 0.2 13.7 +-
.4 l 2.0 fl0 NET DATA 003 67 0.2 16.3 +-
.5 ;
2.4 fl0 t1ET DATA 004 92 0.3 15.1 +-
.5 l 2.3 N0 i1ET DATA 005 115 0.4 14.3 +-
.4 l 2.1 t10 NET DATA 006 143 1.1 12.4 +-
.4 l 1.9 t10 flET DATA 007 150 2.0 13.3 +-
.4 l 2.0 N0 t1ET DATA 008 154 4.7 15.8 +-
.5 ;
2.4 N0 i1ET DATA 009 15' 0' ?
14.3 +-
.4 ;
2.1 N0 f1ET DATA 010 152 22.
9.6 +-
.3 l 1.4 t10 llET DATA 011 152 22.
15.3 +-
.5 l 2.3 N0 t1ET DATA 012 168 14.
14.8 +-
.4 ;
2.2 t10 t1ET DATA
)
013 185 10.
14.1 +-
.4 ;
2.1 NO NET DATA 014 183 11.
17.6 +-
.5l 2.5 N0 tlET DATA 015 170 8.0 15.4 +-
.5 ;
2.3 t10 NET DATA 016 196 7.0 15.3 +-
.5 ;
2.3 l10 NET DATA 017 229 7.9 13.6 +-
.4 l 2.0 N0 t4ET DATA 018 250 6.6 12.5 +-
.4 ;
1.9 N0 i1ET DATA 019 247 4.8 14.2 +-
.4 l 2.1 NO NET DATA 020 229 5.0 14.9 +-
.4 ;
2.2 N0 IIET DATA 021 208 3.8 MISSIllG OR DAMAGED DOSIMETER 022 187 3.8 14.9 +-
.4 ;
2.2 t10 t1ET DATA 023 203 2.6 14.1 +-
.4 ;
2.1 N0 11ET DATA 024 245 1.9 12.8 +-
.4 l 1.9 N0 t1ET DATA 025 280 20 14.2 +-
.4 l 2.1 t10 llET DATA 026 299 3.1 14.7 +-
.4 ;
2.2 NO NET DATA 027 305 3.8 13.8 +-
.4 l 2.1 NO NET DATA 028 276 4.0 13.8 +-
.4 l 2.1 N0 tiET DATA 024 0'43 5.8 14.2 +-
.4 l 2.1 N0 tiET DATA 030 316 7.7 14.4 +-
.4 l 2.2 t10 NET DATA 032 300 10.
14.6 +-
.4 ;
2.2 N0 flET DATA 033 322 8.7 16.7 +-
.5 l 2.5 NO NET DATA 034 339 8.8 14.3 +-
.4 ;
2.1 NO NET DATA 035 342 2.9 12.7 +-
.4 ;
1.9 N0 flET DATA 036 346 1.9 14.4 +-
.4 l 2.2 NO NET DATA 037 353 1.0 14.4 +-
.4 l 2.2 NO NET DATA 038 226 2.0 13.4 +-
.4 l 2.0 NO NET 6ATR 110 TRA!151T DOSE CALCULATED (TLD C0!1TROLS' MISSING OR OTHERWISE NOT COMPLETE)
1 ST.LUCIE FOP THE PERIOD 821217-530415 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZD1UTH (dag. )
AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Otr.) t-Std.Dev.
348.75-1L.25 (N) 10.8 +- 0.0 1
11.25-33.75 (NNE) 9.9 +- 0.0 1
33.75-56.25 (NE) 10.2 +- 0.0 1
56.25-78.75 (ENE) 12.2 +- 0.0 1
78.75-10l.25 (E) ll.3 +- 0.0 1
10l.25-123.75 ( ESE) 10.7 +- 0.0 1
123,75-146.25(SE) 9.3 +- 0.0 1
14 5.25-168. 7 5 ( 55E )
ll.D 4-
.9 3
168.75-191.25(5) ll.6 +- 1.1 4
19 L.25-213.75 ( 55H )
11.D +
.6 2
213.75-236.25(SW) 10.5 +
.6 3
238.25-258.75(usu) 9.8 +
.7 3
258.75-281.25(W) 10.5 +
.2 2
28L.25-303.75(WNW) 10.9 +
.2 3
303.75-326.25(NH) ll.2 +- 1.1 3
326.25-348.75(NNH) 10.3 +
.7 9
DISTANCE (mi) FROM THE REACTOP RVER. EXPOSURE RATE
+ IN GROUP
( niR/ 5t d. 0 t r. ) + -St d. De v.
B-2 10.4 +
.8 11 2-5 10.7 +
.6 la
>5 11.1 +- 1.0 12 LPHIND CONTROL ORTA 9.8 +- 2.3 3
I
SALEM TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821222-830412 112 DAYS FIELD TIME 92 DRYS NRC
.0 CATION GROSS NET EXPOSURE RATE STATION Fl.MUTH/DIST EXPOSURE (mR) mR/Std.0tr.
( n a. )
(m1.)
+- Rdm: Tot.
+- Rdm; Tot.
002 79~
3.4 16.2 +-
.5 ;
2.4 13.6 +-
.7 ;
3.2 003 72 3.6 14.5 +-
.4 l 2.2 12.0 +-
.7 l 3.0 004 58 4.2 14.5 +-
.4 l 2.2 12.0 +-
.7 l 3.0 005 54 4.9 15.4 +-
.5 l 2.3 12.9 +-
.7';
3.1 006 68 S.6 14.5 +-
.4 l 2,. 2 12.0 +-
.7 l 3.0 n
e o..
e a
J -
.e
-.4 i0.5.
- n. n.,I 4 n.
=.l. ;1 1D.0 4
J a d q 1
.I q
008 116 11.
16.7 +-
.5 l 2.5 14.2 +-
.7 l 3.3 e
o e
v..-
44 0 o.J to.7 +-
7 9.1
- n. i n-R.
=. p te.n +-
.ed q
- 1 I
q v
011 15 8.1 14.7 +-
.4 l 2.2 12.2 +-
.7 l 3.0 010 94 8.6 14.5 +-
.4 ;
2.2 12.0 +-
.7 l 3.0
' n.
- n. i a.
n'O O.
l n'. 'c +-
4 ',
0.0 10.0 +-
7, a.
014 90 6.7 16.3 +-
.5 l 2.4 13.8 +-
.7 l 3.2 015 105 6.4 15.4 +-
.5 l 2.3 12.8 +-
.7 l 3.1 022 266 4.7 MISSING OR DRMAGED DOSIMETER
^
0.0
. =. >
- 0.0 T R A N O T. T.D0.0C
=
+-
COMt1ENTS:
THIS STATION TLD EXCHRNGE IS DIVIDED EETHEEN THE STATES OF N.J. AND DEL. STRTION 1-l6 (N.J.).5TRTION 17-50 (DEL.)
SALEM FOR THE PERIOD 821222-830412 TLD DIRECT RADIATI0ti ENVIRONMENTAL MONITORING RZIMUTH (deg.)
tJET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Otr.) t-Std.Dev.
348.75-11.25 ( to 12.7 +- 0.0 1
11.25-33,75 (NNE) 12.1 +
.1 2
33,75-56.25 (NE) 12.9 +
.8 3
56.25-78.75 (EtJE) 12.0 +- 0.0 3
78.75-10L.25 (E) 13.7 +
.1 2
101.25-123.75(ESE) 13.5 +
.9 2
123.75-146.25(SE)
NO DRTR+-NO DATR 0
14 5.25-168. 75 ( 55E )
NO DATR+-tJO DRTR 0
168.75-191.25(5)
NO DRTR+-NO DRTR 0
191.25-213.75(55H)
NO DRTR+-NO DRTR 0
213.75-236.25(SW) tJO IIRTA+-N0 DATA 0
236. 25-25 8. 75 ( tJ 5l1)
NO DATRt-tJO DATR 0
258.75-281.25(10 NO DATAt-NO DATR 0
281. 25-3 03. 75 (l4N61)
NO DRTAt-NO DATR 0
303.75-326.25(NH)
NO DATAt-NO DATR 0
326.25-348. 75 ( NtJ W )
NO DATR+-NO DATA 0
i DISTANCE (mi) FROM THE REACTOP NET RVER. EXPOSURE RATE
+ IN GROUP (mR/5td.0tr.) +-5td.Dev.
0-2 NO DRTRt-NO DATR G
2-5 12.E +
.B 4
>5 12.B +
.B 9
UPNIND CONTROL DATA NO DATA NO DATR
SALEll TLD DIRECT RADIATION ENVIRONMENTAL MONITORIt1G FOR THE PERIOD 821222-830412 112 DAYS FIELD TIME 92 DAYS IIRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
+- Rdm; DATA Tot.
(dea.)
(mi.)
+- Rdm; Tot.
017 33I 4.2 17.6 +-
.5 ;
2.6 N0 flET 018 320 3.8 16.0 +-
.5 l 2.4 l10 tiET DATA 019 299 3.4 19.5 +-
.6 l 2.9 l10 tlET DATA 021 276 3.6 20.3 +-
.6 ;
3.0 N0 flET DATA 000 066 4.7 illSSING OR DAMAGED DOSIMETER 023 257 4.4 19.3 +-
.6 ;
2.9 NO NET DATA 024 240 4.4 19.1 +-
.6 l 2.9 ti0 NET DATA 025 217 4.9 15.6 +-
.5 l 2.3 N0 I4ET DATA 026 204 3.9 18.9 +-
.6 ;
2.3 NO NET DATA 027 188 4.2 19.0 +-
.6 l 2.8 t10 NET DATA 028 319 20 21.5 +-
.6 l 3.2 N0 t1ET DATA 029 265 6.7 18.4 +-
.6 l 2,3 t10 NET DATA 030 350 12.
19.1 +-
.6 l 2.9 N0 flET DATA 031 0
in 00.6 +-
.6 l 3.1 N0 I1ET DATA 032 338 8.1 14.2 +-
.4 l 2.1 N0 tiET DATA 033 265 9.5 18.9 +-
.6 ;
2.8 NO NET DATA 034 270 13.
18.8 +-
.6 l 2.8 N0 flET DATA t10 TRANSIT DOSE CALCULATED (TLD C0t1TROLS'f1ISSIllG OR OTHERWISE NOT COMPLETE)
COMMENTS:
THIS STATI0rJ TLD EXCHRflGE IS DIVIDED BETHEEtJ THE STATES OF N.J.
AND DEL. STRTION 1-l6 (N.J.).5TATION 17-50 (DEL.)
f SALEM F0F THE PERIOD 821222-83041c TLD DIRECT RADIATION EtIVIRONMENTAL MONITORING l
RZIMUTH (dag.)
AVER. EXPOSURE PATE
- IN GROUP (mR/Std.Ote.) t-Std.Dev.
348.75-1L.25 (N)
NO DRTA+-NO DATR 0
11.25-33.75 (NNE)
NO DATA +-NO DATR 0
33.75-56.25 (NE)
NO DRTA+-NO DATR 0
56.25-78.75 (ENE)
NO DATA +-NO DATR 0
78.75-101.25 (E)
NO DATA +-NO DATR 0
10l.25-123.75(ESE)
NO DATR+-NO DATR 0
123.75-146.25(SE)
NO DRTA+-NO DATR 0
14 6.25-168. 75 ( 55 E )
NO DRTR&-NO DRTR 0
168.75-191.25(5) 15.2 +- 0.0 1
19t.25-213.75(55H) 15.1 +- 0.0 1
213.75-236.25tSW) 12.5 +- 0.0 1
238.25-258.75(W5W) 15.4 +
.1 2
258.75-281.25(W) 15.3 +
.7 4
28l.25-303.75(WNW) 15.6 +- 0.0 1
303.75-328.25(NH) 12.B +- 0.0 1
326,25-348.75(NNN) 12.8 +- 1.9 2
DISTRNCE(mi) FROM THE REACTOP RVER. EXPOSURE RATE
+ IN GROUP (mR/Std.Qtr.)
+-5t d. De v.
j 0-2 NO DRTRt-NO DATR G
2-5 14.7 +- 1.3 9
>5 14.1 +- 1.8 4
UPNIND CONTROL DATA 16.4 +- 1.0 3
SAN ONOFRE TLD DIRECT RAD 73 TION ENVIRONMENTAL MONITORING FOR THE PERIOD 821222-830512 142 DAYS FIELD TIME 95 DAYS HRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 346 35.
37.6 +-
1.1 ;
5.6 28.6 + ' 1.3 ;
6.3 002 346 35, 37.8 +-
1.1 l 5.7 28.8 +-
1.3 l 6.4 003 346 35.
39.5 +-
1.2 l 5.9 30.4 +-
1.4 l 6.6 004 327 11.
31.0 +-
.9 ;
4.7 22.4 +-
1.2 l 5.6 005 303 14.
36.1 +-
1.1 l 5.4 27.2 +-
1.3 l 6.2 006 307 10, 33.3 +-
1.0 l 5.0 24.6 +-
1.2 l 5.8 007 318 6.3 35.1 +-
1.1 l 5.3 26.2 +-
1.3 l 6.1 008 322 5.1 35.4 +-
1.1 l 5.3 26.5 +-
1.3l 6.1 009 311 3.3 MISSING OR DAMAGED DOSIMETER 010 331 3.3 MISSING OR DAMAGED DOSIMETER 011 300 2.5 35.0 +-
1.0 ;
5.2 26.1 +-
1.3 ;
6.0 010 085 0.5 MISSING OR DAMAGED DOSIMETER 013 3?A
?.4 31.6 +-
.9 ;
4.7 22.9 +-
1.2 ;
5.6 014 320 1.7 34.0 +-
1.0 l 5.1 25.2 +-
1.2 l 5.9 015 333 1.2 34.9 +-
1.0 l 5.2 26.0 +-
1.3 l 6.0 016 30 1.9 35.8 +-
1.1 l 5.4 26.9 +-
1.3 ;
6.1
- 017, 8
1.3 31.0 +-
.9 l 4.7 22.4 +-
1.2 l 5.6 i.o 3,
e.=
o. ;4 S e. o. +_
i.o e e.y c;.e 4._
o og n_io c
q o
v g
33 v
Oly 55 2.1 Os.3 +-
1.1,
o.3 2e.5 +-
1.3 ;
e.1 020 77 4.1 29.6 +-
.9 l 4.4 21.1 +-
1.1 ;
5.4 021 87 4.7 37.0 +-
1.1 l 5.6 28.1 +-
1.3 l 6.3 022 25 3.4 34.4 +-
1.0 l 5.2 25.6 +-
1.2 l 6.0 023 357 3.5 MISSING OR DAMAGED DOSIMETER
~
024 25 0.4 32.7 +-
1.0 ;
4.9 23.9 +-
1.2 ;
5.8 025 81 0.4 34.0 +-
1.0 ;
5.1 25.2 +-
1.2 l 5.9
- 026, 1,26 2.1 32.3 +-
1,.0 l 4.8 23.6 +-
1.2,l 5.7 n -
n..
..p i
..4 3
.o-vu o.o 30.3 +-
e.c c4.e +-
1.c,
e.n Uncr sU so 028 99 8.9 32.5 +-
1.0,
4.9 23.8 +-
1.2 l 5.8 029 135 11.
30.2 +-
.9 l 4.5 21.6 +-
1.2 l 5.5 030 12A
?.0 29.7 +-
.9 l 4.5 21.2 +-
1.1l 5.4 031 128 3.7 28.5 +-
.9 ;
4.3 20.0 +-
1.1 ;
5.3 032 14A
??.
MISSING OR DAMAGED DOSIMETER 033 120 26.
MISSING OR DAMAGED DOSIMETER TRANSIT DOSE =
7.4
+-
.8 ; 3.6 I
l
SAN ONOFRE FOR THE PERIOD 821222-830512 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dag. )
NET AVER. EXPO 5URE RATE
$ IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-11.25 (N) 22.4 +- 0.0 1
11.25-33.75 (NNE) 25.5 +- 1.5 3
33.75-56.25 (NE) 28.0 +- 2.2 2
56.25-78.75 (ENE) 21.1 +- 0.0 1
78.75-101.25 (E) 25.7 +- 2.2 3
101.25-123.75(ESE)
NO DRTA+-NO DATR 0
123.75-146.25(SE) 22.2 +- 1.9 5
14 5.25-150. 75 ( 55E )
NO DRTR&-NO DRTR 0
150.75-191.25(5)
NO DRTR&-NO DRTR 0
191. 25-2 l 3.75 ( 55 N )
NO DRTR&-NO DRTR O
213.75-236.25(SN)
NO DATA &-NO DATR 0
236.25-258.75(WSH)
NO DATAt-NO DATR G
258.75-281.25(W)
NO DRTAt-NO DATR G
281.25-303.75(uNW) 28.1 +- B.O 1
303.75-328.25(NN) 25.4 +- 1.5 6
326.25-348.75(NNN) 24.2 +- 2.6 2
i DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP (mR/5td.Qtr.) +-5t d. De v.
B-2 24.4 +- 2.0 7
2-5 24.B +- 3.2 9
>5 24.5 +- 2.0 8
UPNIND CONTROL ORTA 29.3 +- 1.0 3
1 SERER 00K TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821221-830412 113 DAYS FIELD TIME 100 DAYS i
i NRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
l (dea.)
(mi.)
+- Rdm: Tot.
+- Rdm; Tot.
001 157
.7 23.2 +-
.7 ;
3.5 20.2 +-'
.8 ;
3.7 002 179
.7 21.7 +-
.7 l 3.3 18.9 +-
.7 ;
3.5 003 199
.7 MISSING OR DAMAGED DOSIMETER 004
???
9 21.0 +-
.6 ;
3.1 18.2 +-
.7 ;
3.5 005 244 1.2 19.1 +-
.6 l 2.9 16.5 +-
.7 ;
3.3 006 293 1
17.7 +-
.5 l 2.7 15.3 +-
.7 ;
3.1 00r cr5
.5 17.9 +-
.5 l 2.7 15.4 +-
.7 ;
3.1 008 317 2.8 19.4 +-
.6 ;
2.9 16.8 +-
.7 ;
3.3 009 331 1.6 19.5 +-
.6 l 2.9 16.9 +-
.7 ;
3.3 010 358 1.9 19.3 +-
.6 l 2.9 16.7 +-
.7 ;
3.3 011 On
?.6 16.9 +-
.5 ;
2.5 14.5 +-
.6 ;
3.0 012 50 2.1 16.4 +-
.5 ;
2.5 14.0 +-
.6 ;
3.0 013 82 1.7 1^.4 +-
.6 l 2.8 15.9 +-
.7 ;
3.2 014 43 4.1 18.8 +-
.6 l 2.3 16.2 +-
.7 ;
3.2 015 0
4 17.9 +-
.5 l 2.7 15.4 +-
.7 l 3.1 18.6 +-
.6 ;
2.3 16.1 +-
.7 l 3.2 016 20
,12.-.
~
7.
S 5 S.Y 1 D". 7
.I q
. =,. =,
47.4, i~
j.-
.D d -
i O.O 0[
did
[.d q
Olc 092 3.9 18.3 +-
.5 l 2.7 15.8 +-
.7 l 3.2 019 269 9.9 22.2 +-
.7' 3.3 19.3 +-
.7 l 3.6 020 253 4.2 MISSING OR DAMAGED DOSIMETER 021 232 4.7 19.3 +-
.6 ;
2.9 16.7 +-
.7 ;
3.3 022 213 6.1 20.8 +-
.6~;
3.1 18.0 +-
.7 l 3.4 zu,., +-
.t-2,. 8 16,.3 +-
.7,l 3.2 18.9 +-
.6' 023 189 6,. 6 a.0 1c.s +-
.i
,6 0.4 e
e, t,
l e. -
c. :,
c t
025 177 41 OA.6 +-
.6, 3.1 17.8 +-
.7 l 3.4 026 159 4
21.1 +-
.6 l 3.2 18.3 +-
.7 l 3.5 027 138 2.4 20.8 +-
.6 l 3.1 18.0 +-
.7 l 3.4 00 '. +.-
q' v'. 1 l '[. 'e
.,1'
'.4
- 0. _? ?
117
- 4. 4
+-
,.I v,
v i
g v
U00 to
.1 cc.z +-
.c ;,
4.s 6
n -
1q..,, o +-
.t 2.t 4
031 336 5.4 MISSING OR DAMAGED DOSIMETER 032 237 18.
22.4 +-
.7 ;
3.4 19.4 +-
.8 ;
3.6 033 237 18, 21.8 +-
.7 ;
3.3 18.9 +-
.7 l 3.6 034 237 18.
23.2 +-
.7 l 3.5 20.2 +-
.8 l 3.7 TRANSIT D05E =
.7
+-
.5 ; 2.2 l
l
\\
SERER 00K FOR THE PERIOD 821221-830412 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dag.)
NET RVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-11.25 (N) 16.1 +
.9 2
11.25-33.75 (NNE) 15.3 +- 1.1 2
33.75-56.25 (NE) 15.1 +- 1.5 2
56.25-78.75 (ENE) 19.3 +- 0.0 1
78.75-!OL.25 (E) 15.9 +- 0.0 1
101.25-123.75(ESE) 17.9 +- 0.0 1
123.75-146.25(SE) 18.D +- 0.0 1
14 5.25-168. 75 ( 55 E )
18.5 4-1.4 3
168.75-191.25(5) 17.7 4-1.3 3
19t.25-213.75(55H) 18.B 4- 0.0 1
213.75-236.25(SW) 17.4 4-1.1 2
236.25-258.75(W5W) 18.5 +- 0.0 1
258.75-281.25(H) 17.4 +- 2.8 2
281.25-303.75(WNW) 15.5 +
.4 2
303.75-328.25(NN) 18.8 +
.2 2
326.25-348.75(NNN) 16.9 +- 0.0 1
DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.)
+-5t d. De v.
l 0-2
!?.1 +- 1.7 9
2-5 16.7 +- 1.6 12
>5 17.3 +- 1.2 6
UPHIND CONTROL DRTA 19.5 +
.6 3
SEQUOYAH TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821222-830425 125 DAYS FIriD T.MP C A. M.. Y O.
uw
.- v ww NRC LOCATION GROBS NET EXPOSURE RATE STATION AZIMUTH /DI5T EXPOSUREOaR) rnR/St d. 0t r.
(dec.)
Ga i. )
+- Rda;iot.
+- Rdm; Tot.
001 218 11.
22.8 +-
.7 ;
3.4 16.8 + ~
.8 ;
4.0 o.e c.o to.o. +_
o.
nno onb ie.
io.b.
.c e,
+-
v w
=V v v v
v v
6, 9.<
17 7 +-
4
- 4. 1 20
- v.o nn?
ons
+-
av [.
.a 1
1
--v ws-004 194 2.0 20.4 +-
.6' 3.1 14.6 +-
.8 ;
3.7
- e. *
- ee e
t n e n(4 bt 9 v. m. 7.u t t h4 m T mi",tn U. U gs 1 e.1 1
+4 h4 7. d e. h:u* u+ e nn 006 153 1.5 20.2 +-
.6 ;
3.0 14.4 +-
.8 ;
3.7 007 139 1.9 20.0 +-
.6 l 3.0 14.3 +-
.8 l 3.7 008 115 1.8 20.9 +-
.6 l 3.1 15.1 +-
.8 l 3.8 e
v.s
- .7 t o. c, + -
.o e e n nJ.s 04
- i.. c la.2 +-
v4 v
v v
.d g
w I
w s
V,
s 010 66 1.3 20.5 +-
.6 l 3.1 14.7 +-
.8 ;
3.7 01,1 45, 1.0 21.9 +-
.,7 l
3,. 3 16.0 +-
.8 ;
3.9 n e 4
e4 -
Ic.U +-
.s, 4.1 dc.ic
,4 c. n.
m.U +.-
.r o.o V
1 e
q.q ig.a +-
.q,
ni.
o.g
- .i
- . :, o,-
ww.w
.I 3.9 21.1 +.-
.6 l 3.2 15 3 +-
.8 l 3. 8, s.9 014 1
4.~,
0..0 14.c +-
.o,
4 e
.c 4.0 l y. y.
+-
.t 010 s.<
o,:
10.o 4._
.oi v.q o
i.-
, e ps + b ge A. o.
ol.? t
.i,
v s v
v,
va c
a
's.e
- o. t. : +-
.c e 9.9 i s. 'I' +-
.o e o. Q.-
f41. '6 Qn 1 V v
w V,
v s
018 111 34 21.0 +-
.6' 3.2 15.2 +-
.8 l 3.8 1e.4 +-
.e;
.t-r.
4 c.
.,,n 4.0 Oly laa c.-
-1.c
+-
s. c, 0
u.7 to.s +-
.q e,
o. =-
e n
qa.4 to.
+.-
.eJ
- =
n.on iso i
w s
021 184 4.6 19.0 +-
.6 ;,
2.8 13 3 +-
.8 ;
3.6 v
.v
.U ;,
d.t n. y.
i.s.t +-
.>.4.
10.
3 y. *4 +-
.e ;
U2 c
e e
1e.o +_
.o o. a, c o e.
,4a
,4. o.-
03.c +-
.c, o. :=
a.
1 c.
v.
v sV V,
v 004 041 4.5 19.7 +-
.6 l 3.0 14.0 +-
.8 l 3.7 ne ose o.a sq.c +-
.c e,
o.o lo.o +-
.o e,
o.e v
w v
w V
v d
-wv ws w
s As v
n ;
l,.eo a +-
.o; c.o i.,nc.o +-
.o,
v.e
.)
U.., e-c40 1.e0
.,4,,
s c
027 266 1.2 19.7 +-
.6 l 2.9 13.9 +-
.8 l 3.6 028 291 1.2 19.6 +-
.6 l 2.9 13.9 +-
.8 l 3.6 nmo one t. w:
in.a t-
.g e,
2. %8 14.1 +.-
.oe o.7
-4 4
-we v-s s
v V y v i 030 330 0.5 20.7 +-
.6 ;
3.1 14.9 +-
.8 ;
3.8 031 339 1.8 20.8 +-
.6 l 3.1 15.0 +-
.8 l 3.8 00 555 4.9 19.3 +-
.6-
- 2. 9, 13.6 +-
.8 l 3.6 w
V J.
e e,
o.i o.e t
,i,
o,1 v.;
10 2 +_
.4 4
naq 094 v,
v
,4 v
v s
-vv i s, s + -
.o,e 035 2,77 5.6 MISSING OR DAdAGED DOSIMETER
~
o.5
^1f
- 4. 4 19.: +-
9e w.7 n;4 d
w.s V
.v w
s g
-v nec co o.:
to.c +-
.D o.o to.o +-
.o.,
o.e n
v d vv LVu v V V v 1 2 w
n ;
n en 4
. r.
-.. Ui,
c.7 ic.4 t-
,o,
e.eg j.. e,.d U t~
.i 4
Is.,. -
.. l. o, 4.4 c. e.
i,
(
u,i e d l H L U.e.K u n d e..- e v.nutu 90 IMeve,.titk
- v. n s 4.
..w ty, n
3 Udx 039 290 18 21.4 +-
.6 ;
3.2 15.6 +-
.8 ;
3.8 040 289 18 19.0 +-
.6 l 2.9 13.3 +-
.8 l 3.6 041 318 6.1 21.3 +-
.6 ;
3.2 15.4 +-
.8l 3.8
. 5.
4..A
+-
P =
iP,ANCIT.W~ow w -
v
v.-
SEQUOYAH FOR THE PERIOD 821222-830425 TLD DIRECT RADIATION ENVIRONi1EllTAL MONITORING RZD1UTH (dag. )
tJET AVER. EXPOSURE RATE 4 ItJ GPOUP (mR/Std.Qtr.) t-Std.Dev.
348.75-1L.25 ( tJ )
15.D +- 1.9 2
11.25-33.75
( tJ N E )
16.6 +- 1.9 2
33.75-56.25 (NE) 15.1 +- 1.3 2
56.25-78.75 (ENE) 15.3 +
.8 2
78.75-10L.25 (E) 14.2 +- 2.2 2
10l.25-123.75(ESE) 15.1 +
.1 2
123.75-146.25(SE) 14.8 +
.8 2
145.25-158.75(55E) 13.5 +- 1.4 2
158.75-191.25tS?
13.3 4- 0.0 1
19t.25-2l3.75(55H) 15.1 4-2.5 3
213.75-236.25 ( SH )
14.9 +- 1.9 4
236.25-258.75(H5H) 13.4 +
.8 2
259.75-281.25(H) 13.2 +- 1.1 2
281.25-303. 75 ( u tJ H )
13.4 +
.7 2
303.75-326.25(NH) 14.0 +- 1.5 3
326. 25-34 8. 75 ( NtJH )
12.8 +- 3.7 3
l DISTANCE (mi) FP0t1 THE REACTOP NET RVER.EXPOSUPE RATE
+ If4 GROUP
( n.R/ 5td. 0 t r. ) +-5td.Dev.
0-2 14.5 +- 1.3 15 2-5 14.2 +- 2.1 17
>5 14.7 +- 1.8 4
UPNItJD CONTROL ORTA 14.4 +- 1.6 2
4 SHOREHAM TLD DTRECT RADIATION Et1VIRONMENTAL MONITORING FOR THE PERIOD 821222-830422 122 DAYS FIELD TIME 89 DAYS NRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(deo.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 262 10 14.8 +-
.4 ;
2.2 t10 NET' DATA 002 268 4.4 15.7 +-
.5 ;
2.3 N0 NET DATA 003 256 3.2 MISSIllG OR DAMAGED DOSIMETER 004 268 2.1 MISSING OR DAMAGED DOSIMETER 005 243 1.7 17.2 +-
.5 ;
2.6 t10 NET DATA 007 136 1.5 13.8 +-
.4 l 2.1 NO NET DATA 008 116 0.9 19.6 +-
.6 ;
2.9 NO NET DATA 009 910 0.8 15.4 +-
.5 l 2.3 NO NET DATA 010 730 0.7 MISSING OR DAMAGED DOSIMETER 011 62.
0.7 15.3 +-
.5 ;
2.3 NO NET DATA 012 75 1.6 15.7 +-
.5 l 2.4 NO HET DATA 013 88 2.1 15.8 +-
.5 ;
2.4 NO NET DATA 014 119 4.6 15.7 +-
.5 l 2.4 NO NET DATA 015 110 10.
15.9 +-
.5l 2.4 NO NET DATA 016 138 14.
15.3 +-
.5 ;
2.3 NO NET DATA 017 162 11.
15.3 +-
.5 l 2.3 N0 t1ET DATA 018 170 11.
15.5 +-
.5 l 2.3 NO NET DATA l
l 019 189 5.1 15.5 +-
.5 ;
2.3 N0 flET DATA 021 163 2.5 15.2 +-
.5 l 2.3 NO NET DATA 022 149 1.5 MISSIt1G OR DAMAGED DOSIMETER 023 177 1.3 MISSING OR DAMAGED DOSIMETER 024 196 1.2 16.0 +-
.5 ;
2.4 N0 tiET DATA 025 217 1.5 15.6 +-
.5 l 2.3 NO NET DATA 026 215 4.6 13.9 +-
.4 ;
2.1 110 NET DATA 027 205 4.2 15.6 +-
.5 ;
2.3 NO HET DATA 028 233 11 15.8 +-
.5 l 2.4 NO NET DATA 029 224 12.
MISSING OR DAMAGED DOSIMETER 030 20?
14.
15.5 +-
.5 ;
2.3 NO NET DATA 031 210 15.
MISSING OR DAMAGED DOSIMETER 019 910 15.
15.4 +-
.5 ;
2.3 NO NET DATA 033 210 15.
16.1 +-
.5 l 2.4 NO NET DATA 034 27
.2 15.9 +-
.5 ;
2.4 NO NET DATA 035 50
.3 16.6 +-
.5 l 2.5 N0 IIET DATA t10 TRANSIT DOSE CALCULATED (TLD CONTROLS lMISSIt1G OR 036 133 3.9 17.3 +-
.5 2.6 N0 11ET DATA
SHOREHAM FOR THE PERIOD 821222-830422 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RIIMUTH (deg.)
AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
l 348.75-11.25 (N) 11.3 +- 0.0 1
11.25-33,75 (NNE)
Il.7 +- 0.0 1
33.75-56.25
( N E.)
12.2 +- 0.0 1
56.25-78.75 (ENE) 11.4 +.2 2
I 78.75-10l.25 (E) 11.7 +- 0.0 1
10l.25-123.75(E5E) 12.6 +- 1.6 3
123.75-148.25(SE) ll.4 +- 1.3 3
14 5. 25-15 8. 75 ( 55E )
ll.2 4-
.1 2
158.75-191.25 f 5) 11.1 +- 0.0 2
19L.25-2l3.75(55N) 11.6 +
.2 3
213.75-236.25(SW) ll.1 4-
.8 9
238.25-258.75(H5W) 12.7 +- 0.0 1
4 258.75-281.25(H) ll.2 +
.5 2
28l.25-303.75(HNW)
NO DATAt-N0 DATA 0
303.75-328.25(NN)
NO DRTRt-NO DATR 0
i j
326.25-348.75(NNN)
NO DRTA+-NO DATR 0
l' OISTANCE(mi) FR0t1 THE REACTOR RVER. EXPOSURE RATE
+ IN GROUP tmR/5td.Qtr.) + -5t d. De v.
l B-2 11.9 +- 1.1 10 2-5 11.5 +
.7 7
>5
!!.4 +
.3 8
UPNIND CONTROL ORTA ll.6.+
.4 2
- - ~... - -
i SUMMER TLD DIRECT RADIATI0li EllVIRONMENTAL MONITORIt1G FOR THE PERIOD 821223-830419 118 DAYS FIELD TIME 89 DAYS tlRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (niR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 199 3.7 28.5 +-
.9 ;
4.3 N0 tlET' DATA 002 111 1.0 27.4 +-
.8 l 4.1 ti0 NET DATA 003 340 4.1 28.6 +-
.9 l 4.3 NO NET DATA 004 192 9.3 27.0 +-
.8 l 4.1 NO HET DATA 005 72 1.8 29.6 +-
.9 l 4.4 NO HET DATA 006 54 1.R 06.5 +-
.8 l 4.0 t10 NET DATA 007 46 3.0 33.0 +-
1.0 l 5.0 NO NET DATA 008 31 3.0 34.2 +-
1.0 ;
5.1 N0 flET DATA 009 13 3.9 31.3 +-
.9 l 4.7 110 NET DATA 010 7
4.0 MISSING OR DAMAGED DOSIMETER 011 349 4.3 30.1 +-
.9 ;
4.5 NO NET DATA 012 323 5.0 28.7 +-
.9 l 4.3 NO NET DATA 013 333 3.0 MISSIllG OR DAMAGED DOSIMETER 014 255 2.8 31.5 +-
.9 ;
4.7 NO NET DATA 015 308 5.6 29.4 +-
.9 l 4.4 t10 tiET DATA 016 64 3.5 29.4 +-
.9 l 4.4 N0 llET DATA 017 98 3.1 27.6 +-
.8 l 4.1 N0 llET DATA 018 114 3.5 27.9 +-
.8 l 4.2 NO NET DATA
.8' 4.0 NO NET DATA 019 132 2.0 26.5 +-
.7 ;;
3.3 NO NET DATA 020 152 4.5 21.7 +-
021 133 4.1 21.2 +-
.6 ;
3.2 NO NET DATA 022 157 2.4 23.7 +-
.7 l 3.5 t10 NET DATA 023 173 2.4 25.8 +-
.8 ;
3.9 N0 llET DATA 024 185 3.9 24.3 +-
.7l 3.6 N0 flET DATA 025 210 3.3 23.7 +-
.7 ;
3.6 NO NET DATA 026 217 3.0 23.5 +-
.7 l 3.5 t10 NET DATA 027 231 3.1 22.7 +-
.7 l 3.4 NO NET DATA 028 267 2.7 27.9 +-
.8 ;
4.2 NO NET DATA 029 276 3.4 28.8 +-
.9 l 4.3 NO HET DATA 030 293 3.S 21.5 +-
.6 l 3.2 NO NET DATA 031 244 3.6 24.4 +-
.7 ;
3.7 HO NET DATA 032 247 6.2 25.8 +-
.8 ;
3.9 N0 ilET DATA 033 218 9.0 25.1 +-
.8 l 3.8 NO NET DATA 034 192 9.3 24.3 +-
.7 l 3.6 N0 llET DATA 035 184 14.
21.2 +-
.6 l 3.2 NO NET DATA 036 183 14.
19.8 +-
.6 l 3.0 N0 llET DATA 037 182 14.
19.0 +-
.6 l 2.9 NO NET DATA 038 148 20.
30.7 +-
.9 l 4.6 N0 flET DATA 039 140 25.
27.1 +-
.8 ;
4.1 N0 t1ET DATA 040 135 23.
27.8 +-
.8 l 4.2 NO NET DATA fl0 TRANSIT DOSE CALCULATED (TLD CONTROLS ~ MISSING OP OTHERWISE tiOT COMPLETE) l
SUMMER FOR THE PERIOD 821223-830419 TLD DIRECT RADIATION E!WIRONMENTAL MONITORING RZIt1UTH (deg.)
AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-ll.25 (N) 23.0 +- 0.0 1
11.25-33.75 (NNE) 24.9 +- 1.6 2
33.75-56.25 (NE) 22.7 +- 3.5 2
56.25-78.75 (ENE) 22.5 +-.1 2
78.75-101.25 (E) 21.1 +- 0.0 1
10l.25-123.75(ESE) 21.1 +
.3 2
123.75-146.25(SE) 19.5 +- 2.3 4
14 5. 25 - 150. 75 ( 55 E )
19.3 +- 3.5 3
150.75-191.25(5) 19.1 +
.8 2
191.25-2l3.75(55H) 19.7 +- 1.7 4
213.75-236.25tSW) 10.1 4-
.9 3
238.25-258.75tH5H) 20.7 +- 2.9 3
258.75-281.25(H) 21.6 +
.5 2
28l.25-303.75(HNH) 18.4 +- 0. 0 1
303.75-328.25(NH) 22.1 +-
.4 2
326.25-348.75(NNN) 21.8 +- 0.0 1
1 i
l 1
DISTANCE (mi) FR0t1 THE PEACTOP RVER. EXPOSURE RATE 4 IN GROUP (mR/5td.Qtr.) +-5td.Dev.
B-2 2l.0 +- 1.1 4
2-5 20.5 +- 2.9 23
>5 20.7 +- 1.6 8
UPNIND CONTROL ORTA 15.2 +
.8 3
SURRY TLD DIRECT RADI AT,IO,N ENV,L,R,ONMENTAL.un.,,O,NITORING I
M
.H r-x I O D. e. l z. -..z -os 411 11.-0 to rug i t t
Ve FIELD TIME 92 DAYS HRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Gtr.
+- Rdm; Tot.
+- Rdm T (dec.)
(mi.)
MI.,IJ,b U D..,
n.,.- D v.,.s.,16.7 + ; ot.
00,1
- 119, 1, 8, 18.5 +
.6 ;
2.3 7;
3.3 dd K
nd ut udid T t Oc, t l e..y it t t eU-3 l e- >
I,.
h,I d.,-.Nu-n v-,n,.L D nU.,1M,-rE, 1
u nd t
-o.
ei r t.
004 162 16.
16.2 +-
.5 ;
2.4 14.5 +-
.6 ;
3.0
- n. o:V
,c-e.,1 in.4 +_
.D 9.2 l 'I. ?, +-
7 '
- e
'v. 4 J
lVD V
4e e
8 I 7.
7 i S
3 p
i n *:
lna e.1 1A0.a t-
.e, c.o l o# c +-
0.0
- u. A.-
- uo ey 007 202 2.2 16.2 +-
.5 ;
2.4 14.5 +-
6l 3.0 008 105 1.6 20.8 +-
.6,l 3.1 19.0 +-
7l 3.6 n,
02 9 e4. *4 +-
oe o.o
.i,
.,< i
-- y inets
- u. -.
cc.o t-L,e -
.c V
w
. v,
V v
'.1. 7 +-
o i, o. Q<
h 6 :
4 I. b
- t.1 co.b t-
.(
o.J 0164 E
i
. v c
' q-w4.4 +-
Q i (11 1 1?'D U'4 i
?c.o +-
.oe 9. Q, 0
- 4..,
ww V
V,
v
. s e
.,n o,
c V. o, c_
4.c vi:
1-n
.n.. c n e.,v, o
s..-
cV T-
.u 0.<
013 126 1.2 18.7 +-
.6, 2.3 16.9 +-
7l 3.3 w
. 6' 0'. 4, 7'
'4
,.1 4. 0'. N...
D... h. n.. L - -...,,.i 'f. 9 + -
f.i14 1.,'s 10 0. 0.
+-
w v.
.ww w
nIde1 u uk n
-tv vuoin,titx 3..,
c 1 e.
n 4.0 1
0.1 s.c
.,e 1e.1 +.-
- 1.,8 jt.no +-
.es, c.;
111 r-s 017 126 2.0 15.7 +-
.5 l 2.4 14.0 +-
6l 3.0
.7 7.
i n*in 3.j i "t. no +-
.Ca, c.-
1 o.".1 + -
r r
e.j 0 ce o.c e
w.7 i f. c.t +-
7.
V,. 9 o
- n. i c.
iog V.1 17 7 +-
.e d,
.ws 1
i I
s
. I w
s 1.no lu.,c t-o ;,
c.e w-m
./ x e 0.e 134.s t-021 270 4.1 21.9 +-
.7 l 3.;
?n.1 +-
8l 3.7 w.1.c +-
. c,e 9 >
i n. o: +-
a
,e 97 pJo:
10;
.t o.
9 v
v.
. v v
i v
w 0 2.,.
l h4 S j j n4 S -
7 0. 0" cc.Cs +-
o.
4. {_j S
?s
- A 4
r**
14.0 T-c,
i A
c c -
o. {.j o.4 4 7 i
$ {J. S 4
.D o.E
- l # 4
( {l h" 4.Q 5t 4
b l
V V
. I V V s
025 90 5.2 18.9 +-
.6 l 2.3 17.2 t-cl 3.4
- 4.. i o '. 4. + -
7
- e. o.7 99.D +-
o e poc co
=*. i w3 I
V i ww
. v,
swv s
~
A i C..
d i. D" +~
7 0.4 i. I
. o,
S3 I,
S A S-9 S
7 37 aS U.h hil 1) d o 029 41/
3.0 20.6 +-
.6 ;
3.1 18.8 +-
7l 3.6 b t ;.c
. c3 e.o on..o +-
.D 9.$
- 14. f.t +-
? e 4
9. D" z
V v w
V v
4 s
. I v
- 1. V.-m
&3 17.1 +.-
.ea, 9.V i s_. 4. + -
7 e
.o. 9 e
- n. a s.
4.6 15.2 +-
.5 l
. i.
w s
i s
1.0
- 2. 3, 13.5 +-
6l 2.9 03,1 e
7 e no
- c..o n
- o le.1 +-
. =V
,g.g c
.:.V V
- w. I ic.o i-q.o v
-J s
V w.o oJ V 4
.I. 4 IV.v
.c.
to o +-
47.i
+-
7.
o.4 4
h" S o o.*
4 Lf A
. I V
V,
V 034 303 6.4 17.5 +-
.5';
2.6 15.0 +-
c; 3.2 JV VMV v.0 l '[. 7 +-
5' 0'. 7
- 1. D'. A. + -
7
- 0.0 00=J 5'O J
1 s
u i
. I A
q S y
v a V4s 14, je.Cs +-
. e" i,
.o i o". o& t-7 o.o S n U^e.-
o A r.
7 iv 037 340 15, 15.7 +-
.5 l 2.4 14.fi +-
6';
3.0 n.eo s2 a.
lea.
14.
7,
+-
.,e e, :.o s.q.i+-
ge
> c, v
w w.
039 153 1.9 MISSING OR DAI1 AGED DOSIMETER 040 144 2.1 18.6 +-
.6 ;
2.3 16.8 +-
7; 3.3
.4 ; 2.0 TRANSIT DOSE =
1.3
+-
l
l SURRY FOR THE FERIOL S21223-830411 TLD DIRECT RAII ATION EWIRON!1 ENTAL T10NITORING RZIrluTH (dag.)
fJET AVER. EXPOSUPE PATE 4 IN GROUP (mP/Std.Qtr.) t-Std.Dev.
348.75-11.25 ( tJ )
16.0 +- 2.8 3
11.25-33,75 (fJNE) 20.7 +- 0.0 1
33.75-56.25
( tJ E )
18.8 +- 0.0 1
56.25-78.75 (ENE) 22.6 +- 0.0 1
78.75-10l.25 (E) 17.2 +- 0.0 1
101.25-123.75(ESE) 19.4 +- 2.4 4
123.75-146.25(SE) 18.7
+- 3.5 11 14 5.25-158. 75 ( 55E )
15.1 4-2.2 2
158.75-191.25(5) 15.7 +- 0.0 1
19 t. 25-2 l 3. 75 ( 55H) 14.5 +- 0.0 1
213.75-236.25(SW)
NO DATA +-N0 DATR 0
238.25-258.75(W5Wi 18.1 t-0.0 1
258.75-281.25(W) 20.1 +- 0.0 1
281.25-303.75(WNW) 10.7 +- 0.0 1
303.75-326. 25 ( t4H )
18.4 +-.9 2
326. 25-34 8. 7 5 ( fJtJ H )
16.2 +
.2 2
l DISTRtJCE ( m i ) FR0t1 THE PEACTOP NET RVER. EXPOSURE RATE
+ If4 GR'UP 0
(mP/5td.0tr.) +-5td.Dev.
0-2 19.7 +- 3.6 8
2-5 16.1 +- 2.8 la
>5 17.8 +- 2.5 15 UPHIt4D CONTROL ORTA 14.6 +- 1.9 3
SUSOUEHANNA TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821230-830419 111 DAYS FIELD TIME 92 DAYS NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.:
+- Rdm; Tot.
+- Rdm; Tot.
001 19~
1.4 15.6 +-
.5 ;
2.3 13.5 +-'
.5 ;
2.6 w. a.
1.s.g +._
.e
- . g_
6 e 6 c,.
d,
w l e. 7, +-
.d
- n. n. _o o
t.4 d
003 333 1.7 15.1 +-
.5 l 2.3 13.1 +-
.5 ;
2.5 1'.7
+-
. 4'
'C.?
1?.D +-
5
'q 0'. 4
~
n.a4 a.lA 1. 'I 64 1 g
s w
s w
-s A
005 28?
1.7 16.7 +-
.5 l 2.5 14.6 +-
.6 l 2.7 9.1 i s.. e +_
.s e
?. g.
e e
- n. a. v 07.0 i a is.b +_
c d
i s
q w
4.w As
.s g
w w
_s b
)
d w.0 10
- 14.. [ +=
.4b
)..)
{).7 +-
.Cd q
89 (j k.j 7 w.i s
4 v
1 g
w w
.I 008 217
?
18.5 +-
.6 l 2.8 16.4 +-
.6 l 2.9 009 200 1.4 16.7 +-
.5 l 2.5 14.6 +-
.6 l 2.7 010
,175 1.2 15.7 +-
.5 l 2.3 13.6 +-
.5 ;
2.6 e
n.t n.4 1o.no +-
.ed,
,d e e
.e.y t-
.d e.1 4e n_11 c4V c
c V
d
= e 2_
g e,
2.c
+c.,+_
9.,4 4 4. w,
.v go. :.-
e s_ :.
- c.. e iv V g
4 w
m
_w 2.7 16.0 +-
.6 l 2.9 013 274 3.4 18.2 +-
.5 l
?.e) 14..q +-
- 5. i O.7 c: a v. c.
1 D". 4. + -
A.14 9_0c w
w g
w i
.V g
4 -
vv 015 2
3.8 16.0 +-
.5 ;
2.4 13.9 +-
.5 l 2.6 016 334 4.1 15.5 +-
.5 ;
2.3 13.4 +-
.5 ;
2.5 017 312 4.4 15.6 +-
.5 ;
2.3 13.5 +-
.5';
2.6 018 32 4.9 16.7 +-
.5 l 2.5 14.6 +-
.6 ;
2.7 019 45 9.9 15.7 +-
.5' 2.4 13.6 +-
.5 l 2.6 4
a
- a 2.o tv.o +_
.e 0.0 15.
+_
.D n.o nosJ c=
v si V
v q C
v C q
C V Vd
-w 021 44 3.1 19.0 +-
.6 l 2.8 16.8 +-
.6 l 3.0
!>w.0 103.o +_
.s i C; e d
i
- 14.. A +-
.4 g
fi ? ?
- 4. 7 7 ~
{ 4.. Q +-
4 9.7 t?.Q 4_
e i 7C w.d w
w V s
q I
v sww
~
i fj ~> q
>E 1
w.d
-ww wv is_
s g
w w
aw s
.d q
L i,
4
.5 i, 2.de un c<
- 1.,*
lo.e +-
.e c.o 1n0.4 t-r.4 67 e
d d,
025 108 1.4 15.1 +-
. 5 ~;
2.3 13.0 +-
.5 l 2.5 4
44 e e o.c n.oc to, t.=
tc.o,_
.se o.i wv 6VI a
V 6v V
s q
44.o +_
.d g
C V C
027 152 1.5 16.9 +-
.5 ;
2.5 14.8 +-
.6 l 2.7 028 108 3.7 17.6 +-
.5 l 2.6 15.5 +-
.6 ;
2.8 029 102 4.3 17.4 +-
.5 ;
2.6 15.3 +-
.6 ;
2.8 030 140 4.3 16.4 +-
.5-2.5 14.3 +-
.5l 2.7 031 162 3.4 16.5 +-
.5 l 2.5 14.4 +-
.6 ;
2.7
-e 4e.p t_
.D 0. -[
e e 4li.1._
o. o-p'o o 4:c o.d 1_l q
C
.V q
C
.sw li v J
te c;
oo OU 255
[. 4 i5.
ls a! 5l$
ih.9+_3+-l3 l I 5 9-nc:c:
199
- i tv e +_
+-
035 134 12.
15.3 +-
.5 l 2.3 13.2 +-
.5 ;
2.5 036 114 13.
18.1 +-
.5 ;
2.7 16.0 +-
.6 l 2.9 0,37,,
,. 150 15.
16.2 +-
.5 ;
2.4 14.1 +-
.5 l 2.6 inn.
- 1. 2
,.Ndli vyst =
- 1...0 t-l l
t
i SUSQUEHANNA FOR THE PERIOD 821230-830419 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIMUTH (dag. )
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Otr.) t-Std.Dev.
j 348.75-fl.25 (N) 13.8 +
.2 2
11.25-33.73 (NNE) 14.1 +
.8 2
l 33.75-56.25 (NE) 14.4 +- 2.1 3
56.25-78.75 (ENE) 14.0 +- 1.7 2
78.75-101.25 (E) 13.4 +- D.0 1
101.25-123.75(ESE) 14.6 +- 1.4 3
4 123,75-146.25(SE) 14.3 +
.D 2
14 5.25-158. 75 ( 55 E )
14.5 +
.2 2
158.75-191.25(5) 14.3 4-1.0 2
f 19t.25-213.75(55W) 14.9 4-
.4 2
213.75-236.25(SH) 14.8 4-2.2 2
a 236.25-258.75(H5H) 13.5 +
.8 3
258.7E-281.25(H) 14.8 +- 1.8 2
281.25-303. 7 5 ( HN H )
14.5 +
.2 2
303.75-328.25(NN) 13.1 +
.7 2
326,25-348.75(NNH) 13.3 +
.3 2
i DISTANCE (mi) FR0t1 THE REACTOP NET RVER. EXPOSURE RATE 4 IN GROUP
( n.R/ 5td. Q t r. )
+-5t d. De v.
I B-2 13.7 +- 1.0 16 l
2-5 14.7 +- 1.0 16 1
\\
>5 13.7 +
.1 2
UPNIND CONTROL DATA 14.4 +- 1.4 3
THREE MILE ISLAND TLD DIRECT RADIATION ENVIRONMENTAL HONITORING FOR THE PERIOD 821230-830425 117 DAYS FIELD TIME 93 DAYS NRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSUREOnR) mR/Std.Qtr.
(dea.)
(mi.:
+- Rda; Tot.
+- Rdm; Tot.
001 95' 5.9 12.9 +-
.4 ;
1.9 8.0 +-~
.6 ;
2.8 002 101 3.9 18.0 +-
.5 l 2.7 12.9 +-
.7 l 3.3 003 100 0 7 17.6 +-
.5 l 2.6 12.5 +-
.7 ;
3.3 004 163 1.8 13.6 +-
.4';
2.0 8.7 +-
.6 ;
2.9 005 161 2.2 MISSING OR DAMAGED DOSIMETER
~
006 150 1
13.4 +-
.4 ;
2.0 8.5 +-
.6 ;
2.8 007 136
.6 16.9 +-
.5 l 2.5 11.8 +-
.7 l 3.2 OOS 83
.4 12.5 +-
.4 l 1.9 7.6 +-
.6 l 2.7 009 60
.5 15.5 +-
.5 ;
2.3 10.5 +-
.7 ;
3.1 010 1
1.7 11.4 +-
.3 l 1.7 6.5 +-
.6 ;
2.6 011 25
.9 16.9 +-
.5 l 2.5 11.9 +-
.7 ;
3.2 012 46 2.8 12.8 +-
.4 ;
1.9
- 7. 8, +-
.6 l 2.8
.c ;,
0.4 o.-
Ule 1q lo.9 +.-
.o ;
z.o it.:
T-o 014 358 2.5 11.5 +-
.3 ;
1.7 6.6 +-
.6 l 2.7 016 0
3.1 14.5 +-
.4 ;
2.2 9.5 +-
.6 ;
2.9 018 349 3.5 11.5 +-
.3 ;
1.7 6.6 +-
.6 ;
2.6 019 343 3.2 16.7 +-
.5 l 2.5 11.6 +-
.7~;
3.2 020 318 5
16.0 +-
.5 l 2.4 11.0 +-
.7 l 3.1 021 348 1.3 15.6 +-
.5 ;
2.3 10.6 +-
.7 ;
3.1 022 1r s.!
12.3 +-
.4 ;
--1.3 7.4 +-
.,6
,2. 7 i i.ea +-
.(
0.0 ls.eaa-
.ea c.o Ly m b *4 c.0 t
eo 024 44 3.6 16.8 +-
.5,;
2.5 11.7 +-
.7,;
3.2 034 267 2.3 17.5 +-
.5';
2.6 12.4 +-
.7 l 3.3 035 299 1.8 18.4 +-
.6 l 2.8 13.3 +-
.7 l 3.4 036 267 1 0 10.1 +-
.3 ;
1.5 5.3 +-
.6 l 2.5 037 256 1.4 15.7 +-
.5 ;
2.3 10.7 +-
.7 ;
3.1 038 225 1.9 17.0 +-
.5 l 2.6 12.0 +-
.7 ;
3.2 039 200 2.1 14.9 +-
.4 ;
2.2 9.9 +-
.6 ;
3.0 040 204 2.5 14.8 +-
.4 l 2.2 9.8 +-
.6 ;
3.0
.is I. s-e e,
- o.. o-o..o +_
.D s.a.
a s4?
oeo o
14..o +-
.4 2
g 043 268 "9
91.4 +-
.6 ;
3.2 16.2 +-
.8 l 3.7 044 263 4.7 16.1 +-
.5 l 2.4 11.0 +-
.7 ;
3.1 046 177 3
12.4 +-
.4';
1.9 7.5 +-
.6 ;
2.7 047 177 5.7 18.5 +-
.6 l 2.3 13.4 +-
.7 ;
3.4 a
- o. -
100 o.
17 1 +-
. e, '.
- o..
19.i. +-
a 99 TRANSIT DOSE =
4.6
+-
.5 ; 2.1
.c,
n-s 1
-_ =.
THREE MILE ISLAND FOR THE PERIOD 821230-830425 I
i TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZIt1UTH (dag.)
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Ote.) t-Std.Dev.
4 348.75-11.25 (N) 7.3 +- 1.5 4
11.25-33.75 (NNE) 10.4 +- 2.6 3
33.75-56.25 (NE) 9.8 +- 2.7 2
l 56.25-78.75 (ENE) 10.5 +
.0 2
78.75-101.25 (E) 9.5 +- 3.0 3
1 10l.25-123.75(ESE) 12.5 +- 0.0 1
i 123.75-146.25(SE) 11.8 +- 0.0 1
i 2
14 6.25-168.75 ( 55 E )
8.6 +
.1 2
1 168.75-191.25(5) ll.0 +- 3.1 3
19t.25-213.75(55N)
- 9. 9 +
.1 2
213.75-236.25(SW) 12.0 +- 2.0 1
236.25-258.75(W5W)
NO DATAt-NO DATR G
258.75-281.25(W) 12.4 +- 2.8 4
28l.25-303.75(WNW)
NO DATAt-NO DATR 0
303.75-328.25(NH) 11.0 +- 2.0 1
326.25-348. 75 ( N r!N )
11.1 +
.B 2
i s
DISTRNCE(mi) FR0tt THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP (mR/5td.Qtr.) +-Std.Dev.
B-2 9.8 +- 2.B 9
2-5 9.9 +- 2.1 15
>5 11.9 +- 2.8 6
UPNIND CONTROL DATA
- 9. 7 +- 4.1 3
^
4 3
y
---+-w
-,--,y----
3 E t-
+ - - - - - - -,
,,m 4
_7
TROJAN TLD DTRECT RADIATION ENVIRONMENTAL MONITORING FOR THE FERIOD 821222-830414 114 DAYS FIELD TIME 89 DAYS 1
HRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot, t
001 340 0.6 17.3 +-
.5 ;
2.6 12.5 + '
.9 4.0
.9 ;;
002 334 1.5 19.2 +-
.6 ;
2.9 14.4 +-
4.2 l
003 340 1.7 16.5 +-
.5 ;
2.5 11.7 +-
.9 ;
3.9 004 328 3.9 19.2 +-
.6 l 2.9 14.4 +-
.9 4.2
.9 ;;
i 005 308 4.6 19.2 +-
.6 ;
2.9 14.4 +-
4.2 006 312 4.5 14.3 +-
.4 l 2.1 9.5 +-
.8 3.7 1.0 ;
007 267 4.6 21.8 +-
.7 ;
3.3 17.0 +-
4.5 008 274
.3.8 22.8 +-
.7 ;
3.4 18.0 +-
1.0 l 4.6 009 279 1.7 14.4 +-
.4 ;
2.2 9.6 +-
.8 ;
3.7 010 263 2.0 20.6 +-
.6 ;
3.1 15.8 +-
.9 ;
4.3 011 245 1.6 20.6 +-
.6 ;
3.1 15.9 +-
.9 4.3
.9 ;
012 223 1.9 90.4 +-
.6 :
3.1 15.6 +-
4.3 013 196 1.1 19.4 +-
.6 ;
2.9 14.6 +-
.9 4.2
.9 ;
014 180 1.2 19.3 +-
.6 ;
3.0 15.0 +-
4.2
.9 ;;
015 165 1.7 17.6 +-
.5 ;
2.6 12.8 +-
4.0 016 212 3.9 20.1 +-
.6 ;
'3. 0 15.3 +-
.9 ;
4.3 1
017 230 3.5 20.1 +-
.6 ;
3.0 15.3 +-
.9 4.3 018 162 9.3 19.6 +-
.6 ;
2.9 14.8 +-
.9 ;
4.2 019 172 5.0 20.8 +-
.6 l 3.1 16.1 +-
.9 ;
4.4 020 334 5.8 18.0 +-
.5' 2.7 13.2 +-
.9 ;
4.1
.6 ;;
021 345 5.5 18.7 +-
2.8 13.9 +-
.9 ;
4.1 022 356 5.5 16.9 +-
.5 ;
2.5 12.1 +-
.9 ;
4.0 023 8
3.9 17.2 +-
.5 ;
2.6 12.4 +-
.9 ;- 4.0 024
-15 3.7 17.4 +-
.5 ;
2.6 12.6-+-
.9 ;
4.0 i
025 27 1.9 17.2 +-
.5 ;
2.6 12.4 +--
.9 ;
4.0 026 37 2.1 19.3 +-
.6 ;
2.9 14.5 +-
.9 ;
4.2 027 60 2.9 20.0 +-
.6 ;
3.0 15.2 +-
.9 l 4.3 028 55 4.5 13.2 +-
.4 ;
2.0 8.4 +-
.8 ;
3.6 029 69 1.6 19.4 +-
.6 ;
- 2. 9
- s. 14.6 +-
.9 ;
4.2 030 83 3.9 15.9 +-
.5 ;
2.4 11.1 +-
.9 l 3.9 031 93 2.7 20.0 +-
.6 ;
3.0 15.2 +-
.9 ;
4.3 032 119 2.2 20.3 +-
.6 ;
3.0 15.5 +-
.9 ;
4.3 033 106 5.3 17.9 +-
.5 ;
2.7 13.1 +-
.9 ;
4.1 034 134 2.5 16.,7 +-
.5 ;
2.5 11.9 +-
.9 ;
3.9 035 14s 4.<
le.c t-
.a ;
2.0 11.9 +-
.9 ;
3.9 036 270 17.
21.0 + '
.6 ;
3.1 16.2 +-
.9 4.4 1.0 ;
3 i
037 270 17.
23.1 +-
.7 ;
3.5 18.3 +-
4.6 18.3 +
1.0 ;
035 270 17.
23.1 +-
.7 ;
3.5 4.6
^ TRANSIT DOSE =
4.9
+-
. 7 ; 3.0 I
l l
-w
-m w
m--e-W
TROJAN FOR THE PERIOD 821222-830414 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING AZDIUTH (deg.)
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Otr.) t-Std.Dev.
348.75-1L.25 (N) 12.3 +
.2 2
11.25-33.75 (NNE) 12.5 +
.1 2
33.75-56.25 (NE)
It.4 +- 4.3 2
56.25-78.75 (ENE) 14.9 +
.4 2
78.75-101.25 (E) 13.1 +- 2.9 2
10l.25-123.75(ESE) 14.3 +- 1.7 2
123.75-146.25(SE) ll.9 +
.D 2
145.25-158.75(55E) 13.8 +- 1.4 2
158.75-191.25(5) 15.5 +
.8 2
19L.25-2l3.75(55N) 15.0 +
.5 2
213.75-23G.25(SW) 15.5 +
.2 2
238.25-258.75(H5W) 15.9 +- 0.0 1
258.75-281.25(N) 15.1 +- 3.8 4
28l.25-303.75(HNW)
NO DRTAt-NO DATR 0
303.75-328.25(NN)
It.9 +- 3.5 2
326,25-348.75(NNN) 13.3 +- 1.1 6
~
DISTANCE (mi) FROH THE REACTOP NET hiER EXPOSURE RATE 4 IN GROUP (mR/5td,0tr.) + -St d. De v.
B-2 13.7 +- 1.9 12 2-5 13.B +- 2.8 18
>5 13.4 +- 1.0 5
UPNIND CONTROL DRTA 17.8 +- 1.2 13
TURKEY POINT TLD DIRECT RADIATI0t1 EtiVIR0t1 MENTAL MONITORIl1G FOR THE PERIOD 821217-830415 120 DAYS FIELD TIME 102 DAYS flRC LOCATI0ti GROSS tlET EXPOSURE RATE STATI0a AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rda; Tot.
+- Rdm; Tot.
001 310 1.3 9.7 +-
.3 ;
1.4 7.2 + '
.5 ;
2.2 002 292 2.4 14.5 +-
.4*
2.2 11.4 +-
.6 ;
2.6 003 340 1.9 9.1 +-
.3 ;
1.4 6.7 +-
.5 l 2.2 004 354 2.0 9.5 +-
.3 l 1.4 7.1 +-
.5 l 2.2 005 314 3.8 13.6 +-
.4 ;
2.0 10.6 +-
.5 ;
2.6 006 331 4.2 12.9 +-
.4 l 1.9 10.0 +-
.5 ;
2.5 007 291 5.4 10.3 +-
.3~;
1.5 7.7 +-
.5 l 2.3 008 263 5.1 13.3 +-
.4 l 2.0 10.4 +-
.5 t 2.5 009 242 5.7 MISSING OR DAMAGED DOSIMETER
~
01A
?94 6.2 MISSING OR DAMAGED DOSIMETER 011 220 6.2 14.5 +-
. 4 l-2.2 11.4 +-
.6 ;
2.6 019 913 6.9 14.6 +-
.4 ;
2.2 11.5 +-
.6 l 2.7 013 199 10.
14.3 +-
.4 l 2.1 11.2 +-
.6 ;
2.6 014 190 10.
13.5 +-
.4 l 2.0 10.5 +-
.5 l 2.5 015 180 10.
14.7 +-
.4 ;
2.2 11.6 +-
.6 ;
2.7 016 171 10.
14.1 +-
.4 l 2.1 11.1 +-
.6 !
2.6 017 165 9.0 14.0 +-
.4 ;
2.1 11.0 +-
.6 ;
2.6
~
018 203 16.
13.8 +-
.4 ;
2.1 10.8 +-
.6 ;
2.6 019 203 16.
13.5 +-
.4 ;
2.0 10.5 +-
.5 ;
2.5 020 203 16.
15.5 +-
.5 l 2.3 12.3 +-
.6 l 2.7 021 268 8.7 12.8 +-
.4 l 1.9 9.9 +-
.5 l 2.5 022 256 8.0 MISSING OR DAMAGED DOSIMETER 023 275 9.0 14.6 +-
.4 ;
2.2 11.5 +-
.6 ;
2.6 024 285 9.0 15.0 +-
.4 ;
2.2 11.8 +-
.6 l 2.7 025 293 8.7 16.3 +-
.5 i 2.4 13.0 +-
.6 l 2.8 026 301 S.4 MISSING OR DAMAGED DOSIMETER
~
027 311 8.3 14.4 +-
.4 ;
2.2 11.3 +-
.6 ;
2.6 028 327 8.2 15.4 +-
.5 ;
2.3 12.2 +-
.6 l 2.7 029 339 9.3 10.4 +-
.3 ;
1.6 7.8 +-
.5 ;
2.3 l
030 350 8.7 15.3 +-
.5 ;
2.3 12.1 +-
.6 ;
2.7 031 359 9.9 15.2 +-
.5 ;
2.3 12.0 +-
.6 l 2.7 032 2/
18.
15.8 +-
.5 t 2.4 12.5 +-
.6 ;
2.8 033 12/
21.
15.6 +-
.5 ;
2.3 12.4 +-
.6 l 2.7 034 18/
24.
15.8 +-
.5 l 2.4 12.5 +-
.6 ;
2.8 035 28/
22.
13.5 +-
.4 ;
2.0 10.5 +-
.5 ;
2.5 036 15 0.3 13.3 +-
.4 ;
2.0 10.4 +-
.5 l 2.5 037 228 0.5 14.3 +-
.4 l 2.1 11.2 +-
.6 ;
2.6
.5 ; 2.1 TRANSIT DOSE =
1.5 t-t I
l
TURKEY POIllT FOR THE PERIOD 821217-330415 TLD DIRECT RADIATION ENVIR0tiMENTAL MONITORIl1G RZIMUTH (dag.)
NET RVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-11.25 (N) 10.9 +- 2.6 4
11.25-33.75 (NNE) 11.5 +- 1.2 4
33.75-56.25 (NE)
NO DRTR+-NO DATR 0
56.25-78.75 (ENE)
NO DRTA+-NO DATR 0
78.75-10l.25 (E)
NO DATR+-NO DATR 0
101.25-123.75(ESE)
NO DATA &-NO DATR 0
1 123.75-146.25(SE)
NO DATA +-NO DATR 0
i 14 6.25-168. 75 ( 55E )
11.0 4-B.O 1
169.75-191.25(5) 11.1 4-
.5 3
19 l. 25-2 l 3.75 (55H) ll.1 4-
.2 2
213.?S-236.25(SW) ll.3 +
.2 2
236.25-258.75(USW)
NO DATRt-NO DATR 0
i 250.75-201.25(W) 10.5 +
.8 3
28l.25-303.75(HNH) ll.B t-2.3 4
303.75-326.25(NH) 9.7 +- 2.2 3
326.25-348.75(NNH) 9.2 +- 2.4 4
i l
DISTRNCE(mi) FROM THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP (mR/5td Qtr.)
+-5t d. De v.
B-2 0.5 +- 2.1 5
2-5 10.7 +
.7 3
>5 ll.2 +- 1.4 22 i
UPNIND CONTROL ORTA ll.2 +- 1.0 3
_~
VERMONT YANKEE I
TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821223-830527 156 DAYS FIELD TIME 96 DAYS NRC LOCATION GROSS HET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Gtr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
002 158 1
33.3 +-
1.0 ;
5.0 22.6 + ~ 1.2 ;
5.6 1.1;;
i 003 184 1.3 33.3 +-
1.0 l 5.0 22.7 +-
1.2 5.6 004 201 1.4 32.8 +-
1.0 ;
4.9 22.2 +-
5.5 i
005 220 1.6 32.1 +-
1.0 ;
4.8 21.5 +-
1.1 ;
5.4 006 157 3.4 33.2 +-
1.0 ;
5.0 22.5 +-
1.2 i 5.5 007 189 4.9 31.6 +-
.9 ;
4.7 21.0 +-
1.1 l 5.4
.9 4.6 20.2 +-
1.1 ;
5.3 008 201 13, 30.7 +-
1.0 ;
3 4.8 21.7 +-
1.1 ;
5.4 1
009 208 5.8 32.3 +-
1.0 ;;
5.0 22.8 +-
1.2 ;
5.6 010 232 3.7 33.5 +-
011 277 2.9 32.0 +-
1.0 l 4.8 21.4 +-
1.1 ;
5.4 i
012 292 1.4 32.8 +-
1.0 l 4.9 22.2 +-
1.1 l 5.5 013 314 1.4 32.1 +-
1.0 l 4.8 21.5 +-
1.1 ;
5.4 014 310 4.2 32.6 +-
1.0 l 4.9 22.0 +-
1.1 ;
5.5 015 299 4.3 31.0 +-
.9 l 4.7 20.5 +-
1.1l 5.3 016 270 4.5 30.9 +-
.9 l 4.6 20.4 +-
1.1 ;
5.3 1
017 331 5
32.7 +-
1.0 l 4.9 22.1 +-
1.1 ;
5.5
]
018 290 18.
31.7 +-
.9 l 4.7 21.1 +-
1.1 ;
5.4 019 290 18.
32.3 +-
1.0 l 4.8 21.7 +-
1.1 l 5.4 i
020 290 18.
32.3 +-
1.0 ;
4.8 21.7 +-
1.1 ;
5.4 021 359 3.2 32.3 +-
1.0 ;
4.8 21.7 +-
1.1 ;
5.4 023 334 2.2 31.8 +-
1.0 ;
4.8 21.2 +-
1.1 ;
5.4 024 4
.9 33.9 +-
1.0 l 5.1 23.2 +-
1.2 ;
5.6 025 30 1
30.9 +-
.9 t 4.6 20.4 +-
1.1 ;
5.3 i
026 72 1.5 34.8 +-
1.0 ;
5.2 24.1 +-
1.2 l 5.7
~
027 44
.7 31.4 +-
.9 l 4.7 20.8 +-
1.1 ;
5.3 028 39 2.8 35.6 +-
1.1 l 5.3 24.8 +-
1.2 ;
5.8 029 25 3.8 32.8 +-
1.0 l 4.9 22.2 +-
1.1 ;
5.5 030 72 2.7 36.4 +-
1.1 l 5.5 25.5 +-
1.2 ;
5.9 031 85 2
32.4 +-
1.0 ;
4.9 21.8 +-
1.1 l 5.5 032 111 1.8 33.1 +-
1.0 l 5.0 22.5 +-
1.2 l 5.5 033 134 4
31.8 +-
1.0 ;
4.8 21.2 +-
1.1 ;
5.4 034 151 6
30.8 +-
.9 ;
4.6 20.3 +-
1.1 ;
5.3 035 til 4.3 33.5 +-
1.0 ;
5.0 22.9 +-
1.2 ;
5.6 1.0 '
1 036 92 4.7 34.6'+-
5.2 23.9 +-
1.2 ;
5.7
.9 ;;
4.6 20.3 +-
1.1 l 5.3 037 50 15 30.8 +-
039 222
.3 30.9 +-
.9 4.6 20.4 +-
1.1 l 5.3 1.0 ;
TRANSIT DOSE =
9.1
+-
.7 ; 3.2 4.8 21.3 +-
1.1 ;
5.4 040 250 3
31.8 +-
)
I I
l l
l
VERMONT YANKEE FOR THE PERIOD 821223-830527 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING l
RZD1UTH (dag. )
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-It.25 (N) 22.5 +- 1.0 2
11.25-33.75 (NNE) 2l.3 +- 1.3 2
33,75-56.25 (NE) 20.3 +- 0.0 1
i 56.25-78.75 (ENE) 25.5 +- 0.0 1
78.75-10L.25 (E) 22.9 +- 1.5 2
10l.25-123.75(ESE) 22.7 +
.3 2
123.75-146.25(SE)
St.2 +- 0.0 1
14 5.25-158. 75 ( 55E )
El.8 4-1.3 3
168.75-191.25(5) 2l.8 4-1.2 2
19t.25-2l3.75(55N) 2l.4 +- 1.0 3
213.75-236.25(SW) 2l.S 4-1.2 3
236.25-258.75(H5H) 2l.3 +- 0.0 1
258.75-281.25(H) 20.9 +
.7 2
28L.25-303.75(HNH) 2l.4 +
.6 5
303.75-328.25(NN) 2l.8 +
.4 2
326,25-348.75(NNN) 2l.7 +
.6 2
DISTANCE ( m i ) FR0t1 THE PEACTOR NET RVER. EXPOSURE RATE
+ IN GROUP (mR/5td.Qtr.) +-5td.Dev.
0-2 2l.9 +
.9 11 2-5 22.0 +- 1.3 16
>5 2l.B +
.7 7
UPNIND CONTROL DATA 23.2 +- 2.1 3
.=
=
14ASHINGT0tl NUCLEAR 2 7LD DIRECT RADlATION EllVIRONMENTAL MONITORING FOR THE PERIOD 821222-830412 112 DAYS i
FIELD TIME 87 DAYS llRC LOCATI0t1 GROSS llET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(deg.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 174 12.
22.0 +-
.7 ;
3.3 16.9 +-
.9 ;
4.1 t
002 163 11.
20.5 +-
.6 ;
3.1 15.4 +-
.8 ;
3.9 003 161 9.0 20.4 +-
.6 ;
3.1 15.3 +-
.8 ;
3.9 1
.7 3.5 18.0 +-
.9 ;
4.2 004 152 5.0 23.0 +-
.6 ;
3.0 14.9 +-
.8 ;
3.8 005 195 2.0 20.0 +-
.5 ;;
2.6 12.4 +-
.8 ;
3.6 006 220 1.5 17.7 +-
1 007 92 3.0 20.3 +-
.6 ;
3.0 15.2 +-
.8 ;
3.9 008 155 1.0 16.8 +-
.5 ;
2.5 11.5 +-
.7 ;
3.5 009 130 0.5 20.4 +-
.6 ;
3.1 15.3 +-
.8 ;
3.9 010 70 0.5 17.7 +-
.5 ;
2.6 12.4 +-
.8 ;
3.6 011 25 0.8 20.5 +-
.6 ;
3.1 15.4 +-
.8 ;
3.9 012 315 0.5 18.1 +-
. 5 ;. 2.7 12.9 +-
.8 ;
3.6 013 290 0.5 20.3 +-
.6 ;
3.0 15.2 +-
.8 ;
3.9 1
014 270 0.5 19.8 +-
.6 ;
3.0 14.7 +-
.8 ;
3.8 015 245 1.8 MISSIllG OR DAMAGED DOSIMETER 016 285 3.0 18.0 +-
.5 ;
2.7 12.8 +-
.8 ;
3.6 j
017 240 4.0 20.3 +-
.6 ;
3.0 15.2 +-
.8 ;
3.9 018 198 7.0 16.5 +-
.5 ;
2.5 11.3 +-
.7 ;
3.4 019 173 8.5 21.8 +-
.7 ;
3.3 16.7 +-
.9 ;
4.1
.6 3.1 15.6 +-
.8 ;
3.9 020 150 20.
20.7 +-
.5 ;;
2.7 12.8 +-
.8 ;
3.6 021 114 7.0 18.0 +-
022 120 8.0 20.3 +-
.6 ;
3.0 15.1 +-
.8 ;
3.9 023 134 6.0 20.5 +-
.6*
3.1 15.4 +-
.8 ;
- 3. 9.
024 110 4.0 MISSIllGORDAllAGEDDOSIMETER 025 85 5.0 17.9 +-
.5 ;
2.7 12.7 +-
.8 ;
3.6 026 65 5.0 19.2 +-
.6 ;
2.9 14.0 +-
.8 ;
3.7 j
027 53 4.0 20.1 +-
.6 ;
3.0 15.0 +-
.8 ;
3.9
~
028 44 8.0 17.5 +-
.5 l 2.6 12.3 +-
.8 ;
3.5 029 33 10.
18.0 +-
.5 ;
2.7 12.8 +-
.8 ;
3.6 030 8
9.5 18.6 +-
.6 ;
2.8 13.4 +-
.8 ;
3.7 031 215 15.
16.6 +-
.5 ;
2.5 11.4 +-
.7 ;
3.4 l
TRAtlSIT DOSE =
5.6
+-
.5 ; 2.2
WASHDIGTON NUCLEAR 2 FOR THE PERIOD 821222-830412 TLD DIRECT RADIATION ENVIRONt1 ENTAL MONITORING RZIMUTH (dag. )
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dav.
348.75-ll.25 (N) 13.4 +- 0.0 1
11.25-33.75 (NNE) 14.1 +- 1.8 2
33.75-56.25 (NE) 13.6 +- 1.9 2
!6.25-78.75 (ENE) 13.2 +- 1.1 2
78.75-101.25 (E) 13.9 +- 1.8 2
101.25-123.75(ESE) 14.0 +- 1.6 2
123.75-146.25(SE) 15.3 +
.1 2
14 5.25-160. 75 ( 55E )
15.2 +- 2.3 5
160.75-191.25(5) 16.7 +- B.O 1
191.25-2l3.75(55N) 13.1 +- 2.6 2
213.75-236.25(SW) 12.4 +- B.O 1
236.25-250.75(WSW) 15.2 +- 2.0 1
258.75-201.25 ( W )
14.7-+- 2.0 1
28L.25-303.75(WNW) 14.0 +- 1.7 2
303.75-326.25(NH) 12.9 +- 2.0 1
326,25-348.75(NNN)
NO DATA +-NO DATR 0
1 DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP (mR/5td.Qtr.) +-5t d. De v.
B-2 13.8 +- 1.5 9
2-5 14.7 +- 1.8 7
>5 14.2 +- 1.7 11 UPNIND CONTROL DRTA 14.1 +- 3.9 2
)
WATERFORD TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821223-830425 124 DAYS FIELD TIME 97 DAYS NRC LOCATION GROS 5 NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.Qtr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 10I 0.4 20.3 +-
.6 ;
3.0 12.2 + ~
.8 ;
3.7 002 116 1.1 MISSING OR DAMAGED DOSIMETER
~
003 132 1.3 17.6 +-
.5 ;
2.6 9.7 +-
.7 ;
3.4 004 160 1.8 20.8 +-
.6 l 3.1 12.7 +-
.8 ;
3.7 005 183 1.4 19.2 +-
.6' 2.9 11.2 +-
.7 l 3.6 wl.n. +-
. D" o.1 i?.o +-
.o e o.?
9*
e
- n. a. s.
000 10 q
v Aw V V g V I
-w 6
w e
o.o e,
o.s o. t.i +-
9 e
- a. n. '<
oog 1.w is.a +-
.a 4
V V 008 248 1.2
?n.? +-
.6 ;
3.1 12.6 +-
.8,;
3.7 ww.
w 9s i o 17 +-
se oe o o +-
7 e o
056 I!!
U5 II.2+-
.3 !
E.$
E.3+-
l7 !
i.o nao 4
011 315 4.4 18.0 +-
.5 l 2.7 10.1 +-
.7 ;
3.4 012 328 4.1 18.1 +-
.5 l 2.7 10.1 +-
.7 ;
3.4
)
013 309 0.8 16.3 +-
.5 ;
2.4 8.5 +-
.7 l 3.3 014 273 04 00.4 +-
.6 l 3.1 12.3 +-
.8 l 3.7 015 292 0.8 21.4 +-
.6 l 3.2 13.3 +-
.8 l 3.8 016 335 0.5 19.1 +-
.6 l 2.9 11.1 +-
.7 l 3.5 017 120 4.3 14.3 +-
.4 ;
2.1 6.6 +-
.7 )
3.1
~
018 145 3.5 MISSING OR DAMAGED DOSIMETER 019 153 81 00.0 +-
.6 ;
3.0 12.0 +-
.8 ;
3.6 020 133 8.1 16.6 +-
.5 ;
2.5 8.8 +-
.7) 3.3 021 11e e.c 15.6 +-
.5 ;
2.3 7.8 +-
.7 ;
3.2 022 95 4.3 19.9 +-
.6 l 3.0 11.8 +-
.8,l 3.6 e
le.oaa t-
.e a,
r.ca t-
.1 a.c L3,0 o c-
,6 a
c.
cV e.
024 66 4.2 20.3 +-
.6 l 3.0 12.2 +-
.8,;
3.7 3,. 5 19.8 +-
.6 l 3,. 0 1,1.8 +-
.8,i 3.6 025 3r e
o o.o l=a.=
t-
.ea, c.o m
,o L,e o-c o.o c.,+-
.c s
V V a
- n. o,l o s. s.'
4. a.-
1D.o +-
.e o.4 o.e +_
e 4
e 4
o.o w
V V -
a q a
W V
.I q
a W s 028 335 5.0 19.9 +-
.6 l 3.0 11.9 +-
.8 l 3.6 029 6
2.8 13.9 +-
.4 l 2.1 6.2 +-
.6' 3.0 030 336 1.1 18.5 +-
.6 l 2.8 10.6 +-
.7 l 3.5 031 15 0.8 18.2 +-
.5 l 2.7 10.3 +-
.7';
3.5 032 40 0.8 15.0 +-
.5 l 2.3 7.3 +-
.7 l 3.1 033 69 1.1 20.3 +-
.6' 3.0 12.2 +-
.8 l 3.7 w..o +-
.D o.e 19.1 +,
.oe 27
- e on
- n. a. 4 999 4=
IV.
w q
J W w
V q v I
-sw e,
9.6 a.<
t-
.i-e, o4 f.il. s.
0 0' ?
77 17.6 +-
.eJ w
V s
n e
e
.o. o ocs.
91.
, lea.4 +-
.e 9.o i.c,-
n.x;c a,
w V w
x, TknHdl,i Du,;tt
.6 ; z.a,
,1 t-
=
r.
c l
(
WATERFORD FOR THE PERIOD 821223-830425 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZDIUTH (dag.)
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-il.25 (N) 8.4 +- 2.2 3
11.25-33.75 (NNE) 9. 0 +- 1.8 2
33.75-56.25 (NE) 9.5 +- 3.1 2
56.25-78.75 (ENE) 12.2 +- 0.0 2
78.75-10l.25 (E) 10.5 +- 2.6 3
10l.25-123.75(ESE) 7.2 +
.9 2
123.75-146.25(SE) 9.2 +
..~
2 145.25-158.75(55E) 12.3 +
.5 2
158.75-191.25(5) 10.3 4-1.3 2
19l.25-213.75(55N) 12.8 4- 0.0 1
213.75-236.2S(SW) 9.0 +- 0.0 1
236.25-258.75(W5W) 12.6 +- 0.0 1
258.75-281.25(W) 10.6 +- 2.4 2
28l.25-303.75(WNW) 13.3 +- 0.0 1
303.75-328.25(NH) 9.3 +- 1.1 2
326.25-348.75(NNH) 11.D +
.9 3
OISTANCE(mi) FROM THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP
( niR/ 5td. Qt r. ) + -5t d. De v.
B-2 10.9 +- 1.8 16 2-5 9.5 +- 2.2 12
>5 9.5 +- 2.2 3
UPNIND CONTROL ORTA 9.8 +- 2.2 3
WATTS BAR TLD DIREC.T RADIATION EtWIRONMENTAL MONITORING FOR THE PERIOD 821222-830425 125 DAYS FIELD TIME 98 DAYS NRC LOCATION GROSS tlET EXPOSURE RATE l
STATION AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
16.5 + ; Tot.
+- Rdm 001 337 0.9 22.6 +-
.7 ;
3.4
.8 ;
3.8 002 314 2.1 23.4 +-
.7 ;
3.5 17.3 +-
.8 l 3.9 003 297 1.9 23.1 +-
.7 ;
3.5 17.1 +-
.8 ;
3.9 004 272 2.0 20.7 +-
.6 ;
3.1 14.8 +-
.8 ;
3.6 005 251 1.9 24.5 +-
.7 l 3.7 18.3 +-
.8 ;
4.0 006 235 1.3 25.5 +-
.8 l 3.8 19.3 +-
.9 ;
4.1 i
007 230 3.8 24.7 +-
.7 ;
3.7 18.5 +-
.9 l 4.0 008 208 3.6 23.7 +-
.7 l 3.6 17.6 +-
.8 ;
3.9 009 249 4.2 21.4 +-
.6 p 3.2 15.5 +-
.8 ;
3.7 010 266 3.1 22.5 +-
.7 ;
3.4 16.5 +-
.8 ;
3.8 1
011 289 3.3 19.1 +-
.6 ;
2.9 13.4 +-
.7 ;
3.4 I
012 310 4.7 MISSING OR DAMAGED DOSIMETER 013 337 3.6 20.2 +-
.6 ;
3.0 14.4 +-
.8 ;
3.5 014 330 7.0 21.3 +-
.6 l 3.2 15.4 +-
.8 l 3.7 015 350 4.7 23.2 +-
.7 l 3.5 17.1 +-
.8~
3.9 i
.8 ;
016 7
1.1 24.1 +-
.7 l 3.6 17.9 +-
4.0 017 23 1.6 19.2 +-
.6 l 2.9 13.4 +-
.7 ;
3.4 018 41 2.3 21.9 +-
.7 ;
3.3 15.9 +-
.8 ;
3.7 019 69 1.3 23.7 +-
.7 ;
3.5 17.6 +-
.8 ;
3.9 020 89 1.2 26.4 +-
.8 ;
4.0 20.0 +-
.9 l 4.2 021 114 1.1 21.0 +-
.6 ;
3.1 15.1 +-
.8 l 3.6 022 141 1.0 25.6 +-
.8 ;
3.8 19.4 +-
.9 l 4.2 023 163 1.1 28.2 r-
.8 l 4.2 21.7 +-
.9 ;
4.5 024 187 1.1 22.7 +-
.7 l 3.4 16.7 +-
.8 ;
3.8 025 203 1.2 23.7 +-
.7l 3.6 17.6 +-
.8 ;
3.9 026 184 5.9 22.4 +-
.7 ;
3.4 16.4 +-
.8 ;
3.8 027 176 4.5 19.7 +-
.6; 2.9 13.9 +-
.7 ;
3.5 028 161 3.5 21.7 +-
.7 ;
3.3 15.8 +-
.8 l 3.7 029 144 3.0 21.1 +-
.6 l 3.2 15.2 +-
.8 l 3.6 030 117 3.1 20.9 +-
.6 ;
3.1 15.0 +-
.8 ;
3.6 031 97 4.0 21.2 +-
.6 ;
3.2 15.3 +-
.8 ;
3.6 032 76 4.1 19.0 +-
.6 ;
2.8 13.2 +-
.7 ;
3.4 033 32 4.1 21.2 +-
.6 ;
3.2 15.3 +-
.8 ;
3.7 034 36 4.7 19.7 +-
.6 l 2.9 13.9 +-
.7 ;
3.5 035 338 18, 20.4 +-
.6 l 3.1 14.6 +--
.8 ;
3.6 036 338 18.
15.8 +-
.5 ;
2.4 10.3 +-
.7 ;
3.1 037 338 18.
22.2 +-
.7 ;
3.3 16.2 +-
.8 ;
3.8
.6 ; 2.4
~
TRANSIT DOSE =
4.5
+-
WATTS BAR FOR THE PERIOD 821222-830425 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZINUTH (dag.)
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dev.
1 348.75-11.25 (N) 17.5 +
.8 2
11.25-33,75 (NNE) 14.4 +- 1.3 2
t 33.75-56.25 (NE) 14.9 +- 1.4 2
56.25-78.75 (ENE) 15.4 +- 3.1 2
78.75-10l.25 (E) 17.7 +- 3.4 2
101.25-123.75(ESE) 15.0 +
.1 2
123.75-146.25(SE) 17.3 +- 2.9 2
145.25-168.75(55E) 18.8 +- 4.2 2
168.75-191.25(5) 15.7 4-1.5 3
19 l.25-213.75 ( 55H) 17.5 +- 8.0 2
P13.75-236.25fSW) 10.9 +
.5 2
I 238.25-258.75(WSW) 1E 9 +- 2.0 2
i 258.75-201. 25 ( W )
- 15. 7 +-
1.2 2
1 28 l. 25-3 03. 75 ( WNW )
15.2 +- 2.6 2
303.75-326.25(NH) 17.3 +- 9.0 1
326.25-348.75(NNN) 15.4 +- 1.1 3
1 DISTANCE (mi) FROM THE REACTOR NET RVER. EXPOSURE RATE
+ IN GROUP (mR/Std.Qtc.)
+-5t d. De v.
9-2 17.5 +- 2.2 14 2-5 15.5 +- 1.5 17
>5 15.9 +
.7 2
UPNIND CONTROL ORTA 13.7 +- 3.1 3
m.
YAllKEE ROME TLD DIRECT RADI ATI0tl ENVIR0!lMEt1TAL MONITORIllG FOR THE PERIOD 821223-830418 117 DAYS FIELD TIME 97 DAYS tiRC LOCATI0tl GROSS tlET EXPOSURE RATE STATI0t1 AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.)
+- Rdm; Tot.
+- Rdm; Tot.
001 0-
.8 20.3 +-
.6 ;
3.0 fl0 flET~ DATA 005 85 2.2 13.0 +-
.4';
1.9 N0 NET DATA 006 118 2.6 MISSIrlG OR DAf1 AGED DOSIMETER 007 137 2.1 14.1 +-
.4 ;
2.1 NO NET DATA 008 153 1.7 13.5 +-
.4*
2.0 fl0 i1ET DATA 009 176 1.1 13.1 +-
.4 ;
2.0 N0 flET DATA 010 203
.5 13.3 +-
.4 ;
2.0 t10 11ET DATA 011 219
.6 13.1 +-
.4 l 2.0 N0 flET DATA 012 239 1.1 17.3 +-
.5 ;
2.6 N0 IIET DATA 013 272 1.8 13.0 +-
.4 ;
2.0 NO NET DATA 014 292 1.3 13.8 +-
.4 ;
2.1 NO NET DATA
~
015 315 1.6 13.4 +-
.4 ;
2.0 N0 hET DATA 016 348 1.4 13.6 +-
.4 ;
2.0 t10 flET DATA 017 358 2.8 12.2
.4 ;
1.8 t10 llEi DATA 018 21 2.8 11.9 +-
.4 l 1.8 t10 flET DATA 019 43 5.?
13.0 +-
.4 ;
2.0 N0 flEi DATA 020 75 6
18.6 +-
.6 l 2.3 N0 llET DATA 021 98 6
19.8 +-
.6 l 3.0 N0 flET DATA 022 104 5.2 11.5 +-
.3 l 1.7 fl0 t1ET DATA 023 133 5.7 11.9 +-
.4 l 1.9 t10 flET DATA J
024 157 7.5 11.7 +-
.3 l 1.7 N0 ilET DATA 025 184 6.3 12.8 +-
.4 l 1.9 110 NET DATA 027 225 5.9 13.7 +-
.4 l 2.0 N0 tiET DATA t
029 269 3.5 12.9 +-
.4 l 1.9 N0 flET DATA 032 342 3.?
14.4 +-
.4 ;
2.2 t10 NET DATA 034 48 7.3 14.1 +-
.4 ;
2.1 t10 t1ET DATA
~
035 39 2.3 12.6 +-
.4 ;
1.9 N0 llET DATA 047 260 9.6 14.5 +-
.4 l 2.2 t10 llET DATA 048 261 9
15.1 +-
.5 ;
2.3 N0 flET DATA t10 TRANSIT DOSE CALCULATED (TLD CONTROLS MISSIllG OR OTHERHISE t10T COMPLETE) a i
YANKEE R0WE FOR THE PERIOD 821223-830418 ILD DIRECT RADIATION ENVIRONMENTAL MON'ITORING RZIt1U TH (dag.)
AVER. EXPOSURE RATE 4 IN GROUP (mR/Std.Qtr.) t-Std.Dev.
348.75-1l.25 (N) 12.5 +- 4.4 2
11.25-33.75 (NNE) 9.2 +- 0.0 1
33.75-56.25 (NE) 10.2 +
.6 3
36.25-78.75 (ENE) 14.3 +- 0.0 1
78.75-10l.25 (E) 12.6 +- 3.7 2
101.25-123.75(E5El 8.8 +- 0.0 1
123.75-146.25(SE) 10.0 +- 1.2 2
14 5. 25-15 8. 75 ( 55 E )
9.7 +- 1.0 2
168.75-191.25(5) 9.9 4-
.2 2
19 L. 25-2 l 3.75 t SSH) 10.2 +- B.O 1
213.75-236.25(SW) 10.3 +
.3 2
236.25-258.75(W5H) 13.3 +- 0.0 1
258.75-281.25(W) 9.9 +
.1 2
28 l.25-303.75 (WNU) 10.6 +- D.C i
303.75-326.25(NH) 10.3 +- 0.0 1
326.25-348.75(NNH) 10.8 +
.4 2
OISTANCE(mi) FR0ft THE REACTOR RVER. EXPOSURE RATE
+ IN GROUP
( n.R/5t d. 0 t r. ) +-Std.Dev.
0-2 ll.1 +- 1.9 10 2-5 10.0 +
.7 7
>5 10.8 +- 2.3 9
UPHIND CONTROL DATA IL.3 +
.3 2
e ZIMMER TLD DIRECT RADIATI0tl EHVIRONMENTAL HONITORING FOR THE PERIOD 821222-830504 134 DAYS FIELD TIME 94 DAYS NRC LOCATION GROSS HET EXPOSURE RATE STAT 10ti AZIMUTH /DIST EXPOSURE (mR) mR/Std.0tr.
(dea.)
(mi.'
+- Rdm; Tot.
l10 IIET; Tot.
+- Rdm 001 182 0. 4.'
22.5 +-
,7 ;
3.4 DATA 002 150 1.0
~21.5 +-
.6 ;
3.2 NO HFT DATA 003 133 1.1 22.2 +-
.7 ;
3.3 t10 NET DATA 004 106 2.1 23.3 +-
.7 ;
3.5 t10 NET DATA 005 82 2.9 21.9 +-
.7 ;
3.3 N0 HET DATA 006 091 4.4 19.9 +-
.6 ;
3.0 H0 HET DATA 007 106 7.3 22.1 +-
.7 ;
3.3 H0 HET DATA 008 135 6.6 24.9 +-
.7 ;
3.7 N0 HET DATA 009 163 4.2 24.6 +-
.7 ;
3.7 N0 HET DATA 010 129 3.9 21.7 +-
.6 ;
3.2 H0 NET DATA 011 115 4. t' 19.6 +-
.6 l 2.9 t10 NET DATA 012 74 3.9 23.9 +-
.7 ;
3.6 N0 11ET DATA 013 50 3.6 22.6 +-
.7 l 3.4 NO NET DATA 014 22 4.1 19.9 +-
.6*
3.0 NO HET DATA 015 354 3.7 21.0 +-
.6 ;
3.1 N0 tlET DATA 016 355 2.1 23.5 +-
.7' 3.5 N0 tlET DATA 017 26 2.0 23.4 +-
.7*
3.5 H0 tiET DATA 018 47 1.6 22.2 +-
.7 ;
3.3 N0 llET UATA 019 72 0.8 21.0 +-
.6 ;
3.1 H0 HET DATA 020 335 7.:
22.6 t-
.7 ;
3.4 N0 NET DATA 021 332 4.0 19.6 +-
.6 ;
2.9 N0 NET DATA 022 335 1.9 22.7 +-
.7 ;
3.4 N0 NET DATA 023 310 2.1 21.0 +-
.6 ;
3.1 fl0 NET DATA 024 286 1.9 21.0 +-
.6';
3.2 N0 flET DATA 025 276 1.4 21.2 +-
.6 ;
3.2 H0 HET DATA 026 247 0.9 22.2 +-
.7 ;
3.3 t10 NET DATA 027 218 1.1 21.6 +-
.6' 3.2 t10 NET DATA
.7'
- 3. 3 H0 llET DATA 02S 200 1.4 91.9 +-
.7 ;
029 191 4.5 22.3 +-
3.3 t10 ilET DATA 030 212 4.4 21.6 +-
.6 ;;
3.2 NO HET DATA 031 229 4.1 20.4 +-
.6 ;
3.1 H0 NET DATA 03?
948 3.5 22.4 +-
.7 !
3.4 110 llET DATA 033 270 3.7 MISSIllG OR DAMAGED DOSIMETER 034 292 4.5 21.0 +-
.6 ;
3.1 t10 flET DATA 035 317 4.6 22.1 +-
.7 ;
3.3 N0 NET DATA 036 106 19.
19.6 +-
.6 ;
2.9 N0 llET DATA 037 107 20.
24.5 +-
.7 ;
3.7 t10 NET DATA 038 107 20.
23.6 +-
.7 3.5 t10 HET DATA NO TRAtl3IT DOSE CALCULATED (TLD C0tlTROLS; MISSING OR OTHERUISE l10T COMPLET I
l
ZIMMER FOR THE FERIOD 821222-830504 TLD DIRECT RADIATIO!! Et1VIR0!! met 1TAL M0t1ITORI!1G RZ DIUTH (dag.)
AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Qtr.) t-Std.Dav.
348.75-11.25 (N) 14.9 +- 1.2 2
11.25-33.75 (NNE) 14.5 +- 1.7 2
33.75-56.25 (NE) 15.0 +
.2 2
56.25-78.75 (ENE) 15.1 +- 1.4 2
78.75-10l.25 (E) 14.0 +
.9 2
10l.25-123.75(ESE) 14.5 +- 1.3 3
123.75-146.25(SE) 15.4 +- 1.2 3
14 5.25-158. 7 5 ( 55E )
15.5 +- 1.5 2
150.75-191.25(5) 15.B +
.1 2
191.25-213.75(55N) 14.5 +
.1 2
213.75-236.25(SW) 14.1 +
.E 2
236.25-250.75(WSW) 15.9 +
.1 2
258.75-281.25(W) 14.2 +- B.O 1
281.25-393.75(WNW) 14.1 +
.9 2
303.75-328.25(NW) 14.4 +
.5 2
326.25-348.75(NNN) 14.5 +- 1.2 3
DISTANCE (mt) FROM TM REACTOR RVER. EXPOSURE RATE
+ IN GROUP (mR/5td.Qtr.) +-5td.Dav.
B-2 14.7 +
.5 12 2-5 14.5 +- 1.9 15
>5 15.5 +- 1.8 3
UPNIND CONTROL DATR 15.1 +- 1.9 3
ZION TLD DIRECT RADIATION ENVIRONMENTAL MONITORING FOR THE PERIOD 821223-830411 110 DAYS FIELD TIME 85 DAYS NRC LOCATION GROSS NET EXPOSURE RATE STATION AZIMUTH /DIST EXPOSURE /.mR) mR/Std.0tr.
(dea.)
(ni.)
+- Rdm; Tot.
+- Rdm; Tot.
001 287 1.0 MISSING OR DAMAGED DOSIMETER
~
002 192 1.0 14.2 +-
.4 ;
2.1 10.8 +-
.7 ;
3.4 003 187 1.5 MISSING OR DAMAGED DOSIMETER
~
004
- 227, 2.4 18.9 +-
.6 ;
- 2. 8, 15.7 +-
.8 ;
3.9 e
- a. n. s-osi 1.9 to.1 +-
.4 e i.o o.D +_
7 o.9 V
I q
V w wo V
w g
14.Cs +-
.v i
5 >
4 Q i S.Qov S'4 1.c 17r.,-
t-
.C c.o S
7 -
a,
bue' 7*
c e.4 007 28<
..e MISSING OR DAMAGED DOSIMETER
~
008 320 1.8 17.5 +-
.5 ;
2.6 14.3 +-
.8 ;
3.7
- a. n. o.
sa.a o_. c
- t. o. 9
- 4. -
.s, o7 i c. r.i + _
.o e,
o.o e
v v
v v v.
010 356 4.5 16.4 +-
.5 l 2.5 13.1 +-
.8 l 3.6 011 337 4.5 12.0 +-
.4 l 1.8 8.4 +-
.7 l 3.1 l
012 310 4.n
?n.1 +-
.6 l 3.0 17.1 +-
.9 l 4.1 014 993 3.5 20.0 +-
.6 l 3.0 16.9 +-
.9 l 4.0
.4 LV.
V G.
L q
V U C i-4.S
[j j '
So[j 4.E S 1.
'.a 4-
. D" O.i
{o.S -
Q 1
3 A
.e g
L
'x 1 +.-
.o ',
?. 4, 1 "v. 4 +-
.o ',
44
~
n.15 004 a. ?.
0 A
v
.a 016 2?7 2.5 20.4 +-
.6 ;
3.1 17.4 +-
.9 l 4.1 017 210 4.5 17.9 +-
.5 l 2.7 14.7 +-
.8 l 3.8 01A 906 2.8 18.5 +-
.6 i 2.8 15.4 +-
.8 l 3.9 019 342 2.7 18.2 +-
.5 ;
2.7 15.0 +-
.8 l 3.8 020 197 14.
14.7 +-
.4 ;
2.2 11.3 +-
.7-3.4 021 352 7.9 17.5 +-
.5 l 2.6 14.2 +-
.8 l 3.7 022 348 S.3 MISSING OR DAMAGED DOSIMETER 023 336 8.5 18.6 +-
.6 ;
2.8 15.5 +-
.8 ;
3.9 024 314 5.8 18.4 +-
.6 ;
2.8 15.3 +-
.8 l 3.8 025 220 6.3 19.4 +-
.6 ;
2.9 16.3 +-
.8 l 4.0 026 195 8.0 18.5 +-
.6 ;
2.8 15.3 +-
.8 ;
3.8 028 197 14.
21.1 +-
.6 ;
3.2 18.1 +-
.9 ;
4.2 030 320 9.8 20.6 +-
.6 ;
3.1 17.6 +-
.9 ;
4.1 031 229 8.0 19.0 +-
.6 ;
2.8 15.8 +-
.8 ;
3.9 TRANSIT DOSE =
4.0
+-
.5 ; 2.4
f ZION FOR THE PERIOD 821223-830411 TLD DIRECT RADIATION ENVIRONMENTAL MONITORING RZINUTH (dag.)
NET AVER. EXPOSURE RATE
- IN GROUP (mR/Std.Otr.) t-Std.Dev.
348.75-ll.25 (N) 13.7 +
.8 2
11.25-33.75 (NNE)
NO DATA +-NO DATR 0
33.75-56.25 (NE)
NO DATA +-NO DATR 0
56.25-78.75 (ENE)
NO DRTA+-NO DATR 0
i 78.75-10l.25 (E)
NO DRTA+-NO DATR 0
!Ol.25-123.75(ESE)
NO DRTA+-NO DATR 0
123.75-146.25(SE)
NO DATA +-N0 DATA 0
146.25-168.75(55E)
NO DRTR&-NO DRTR 0
2 r
168.75-191.25(5)
NO DRTR&-NO DRTR 0
19 t.25-213.75 ( 55N) 14.0 4-2.2 4
213.75-236.25(SW) 1G.3 4-
.7 4
236.25-250.75(W5W) 12.3 +- 5.2 2
250.75-281.25 ( H )
18.3 +- 2.6 2
i 1
28 t.25-303.75 (WNW) 1E.9 +- B.O 1
303.75-326.25(NH) 16.9 +- 1.5 4
326.25-348.75(NNH) 13.5 +- 3.4 4
1 DISTRNCE(mt) FRON THE REACTOP NET RVER. EXPOSURE RRTE
+ IN GROUP (mR/5td Qtr.) +-Std.Dev.
B-2 12.B +- 2.9 4
2-5 15.2 +- 2.5 12
>5 15.7 +- 1.0 7
UPNIND CONTROL ORTA 14.7 +- 4.8 2
N,s en,o _U an u s NUCa AR *EGuATO-Covv.ss.oN i
RC H E*oa T Nsv a E R u co., r,oC..- v.,
N..., A,.
BIBLIOGRAPHIC DATA SHEET NUREG-0837, Vol. 3, No. 1 2 L w.-.
3 TITLE AND Sv8Tif tE 4 HECsPIENT S ACCES5aON NUMBE R i
NRC TLD Direct Radiation Monitoring Network
,,,,,,,,,,,, coy,,,,,,
Progress Report January-March 1983 I,,,,
o o,,,,
October 1983 6 Au THOMi$1 F DATE REPORT t$$UED MONYn vEAR F. Costello, T. Thompson, L. Cohen, M. Taylor October 1983 9 PROJECT T ASA WORE UNIT NUMOER 3 PERFOHviNG oRGANt2ATsON NAME AND MAILING ADDRESS tiarr e l,a Coder u
Region I
,o,,NNuo.ER U.S. Nuclear Regulatory Commission King of Prussia, PA 19406 13 SPONSOReN(, QMG AN,f Af SON N AVE AND MatLsNd ADDR E SS (twee,er la Codef I ?a TYPE OF REPORT Quarterly Same as 8, above.
,2,
,E R,oo Co,E RE o,,,,,,,.
January - March 1983 13 SUPP LE VE N T AR v NOT E S 14 A85TR ACT (100 worar or seras This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network.
It presents the radiation level's measured in the vicinity of NRC licensed facility sites throughout the country for the first quarter of 1983.
1 l
- 15. ME Y WORDS AND DOCuME NT Analysis 150 DESCRIPTOR$
16 AV AsL AtiteT V ST A TE vt NT 17 SECUR CLA$$sFaCAfsON 18 NUM8tR OF PAGE$
Unclassified Un1imited
",'r'f,"D"" 7 " ^ 55" 'c a "
- io "a'c' Un assified s
UNITED STATES s oV RT M CL A$$ 444 MUCLEAR REGULATORY COMMISSION NT AGE 5 FEES PA'O W ASHINGTON. D.C. 20555
.$* SIS c Pf awsi %,112 0FFICIAL OUSINESS l
PENALTY FOR PRI'w' ATE USE.1300 i
120555078877 1 1ANING US NRC AOM-DIV 0F TIDC POLICY & PUB MGT BR-POR NUREG W-501 WASHINGTON DC 20555 i