Environ Assessment & Finding of No Significant Impact Re Requests for Exemption for Containment Isolation Provisions for Recirculation Spray HX river-water Radiation Monitor Sample Lines
ML20081F191
Person / Time
Site: Beaver Valley
Issue date: 06/03/1991
From: Stolz J
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20081F195 List:
References
NUDOCS 9106070160
Download: ML20081F191 (5)


Text

_ - _ _ - _ _ _ _

7590-01 i

b p p)) E 0_ SLAl[,S, pp C L [,A F,R[ CM AT O R Y C OMf 11 S S 10 tl BE AVEP VALLE,Y, POWEP,, STAT 10t(UNIT tl0.1 4

i OU0t'Est!E,L IGHT COMPANY OH10 EDISON COPPAtiY PEhNSYLVAN!A POWER COMPANY POCLET tiO. 50-334 EtlVIR0t!NENTAL ASSESSMENT AND F i t:0 l NC O.F. N..O S I GN I F I.C AN.T..I.M.P A..CT.

The ll, S. Nuclear Fegulatory Conmission (the Conrission) is considering issuance of an exemption to Facility Operating Lic3nse No, OPR-66, issued to Duquesne Light Company (the licensee), f or operation of the Beaver Valley Power Station, l' nit flo,1, (BVPS-1) located in Beaver County, Pennsylvania.

.ENV.IRONM.. ENTAL ASSESSMENT

=

Icentificatjen,of,ProposedAction:

The exemption, proposed by letter dated January 11, 1990, and supplemented by letters dated March 23, 1990 and April 79, 1991, would provide partial relief from the requirements of 10 CFR Part 50, Appendix A, General Design Criterion 57 (GDC 57) with respect to the valve configuration in the recirculation spray system heat exchanger (RSSHx) river water radiation monitor sample lines.

The Need for the Proposed 3,tjon,: The BVPS-1 RSSHx heat exchanger river water radiation monitor sample lines do not have containment isolation valves that are either automatic, remote-manual, or locked closed. Therefore, this configuration does not meet the requirements of GDC 57 relating to containment 9106070160 910603 PDR ADOCK 05000334 l

P FDR

N M [$$}?N O VE1? M '

l

.p isolation. provisions for lines that penetrate containment but that are part of a closed system inside containtient.

Additionally, the Updatec Final Safety Analysis report does not describe this deviation from GDC 57. The proposed exenption would provide partial relief from the requirenients of GDC 57 for this system by perraitting the use of narually-operated isolation valves'in the subject sample lines. The sample lines are nornally open and reust remain open following an accident to detect rapidly any radiation releases through an RSSHx tube leak. Although a radioactivity release eventually could be detected by neans other than the normally open radiation n'onitors in the sample lir.es, it would take much longer to identify and isolate the leaking RSSHx.

Therefore, locked-closed valves or automatic valves in the sarrple lines are not desirable from the standpoint of minimizing releases of radioactivity.

EP.V.iT9PF.0P.t,a,1 J n p,a c t s p,f,,t,hp,,Pyppp s e d A c t i o n :

The Commission has evaluated the environmental impacts of the proposed exemption and has determined that the probability of accidents has not been increased by the proposed alternative testing, and that post-accident radiological releases would not be greater than previously determined.

Further, the Commission has determined that the proposed exemption does not affect routine radiological plant effluents or occupational radiological exocsure.

Accordingly, the Commission concludes that there are no significant redinlogical environmental impacts associated with this proposed exemptico.

With regard to potential ncn-radiological impacts, the proposed exemption involves features located entirely within the restricted area as defined in 10 CFR Part 20.

It does not affect non-radiological plant effluents and has no

_. _ _. _. _ _ _ _. _ _ _. _. _ ~. ~ _ _. _ __

4

. other environmental impact. Therefore, the Commission concludes that-there are no significant non-radiological environmental impacts associated with the proposed exemption.

A l t e rna t i v e,,t o, t,h e, P r,opo s,ed, A c,t i on,:

Since the Commission has concluded that the environmental effects o'f the proposed action are not significant, ady~

alternative with equal or greater environmental impact need not be evaluated.

The principal alternative would be to deny the requested exemption. This would not reduce the environmental inpact attributable to this facility, and

- would result in a larger expenditure of licensee resources to comply with the Coneission's regulations.

Alternative,,Use,,of,Resour,ces; -Th k action does not involve the use of resources not previously considered in the Final Environmental Statement related to_ operation of the Beaver Valley Pcwer Station, Unit 1, dated July 1973.

A g e n c i e s a n,d_,Re,r,s o n,s_,C o n,s u,1,t.e d : The Commission's staff reviewed the licensee's request and did not consult other agencies or persons.

fit;0IllG'0F;NO SIGNIFICANT IMPACT Based upon the foregoing environmental assessment, the Commission concludes that the proposed action will not have a significant effect on the quality of the human environment. Accordingly, the Consission has determined

not to prepare an environmental impact statement for the proposed exemption.

For further details with respect to this action, see the application-for exemption dated January 11, 1990, and supplemented by letters dated March 23 1990 and Ap_ril 29, 1991, which are available-for public inspection at the l

Commission's Public Document Room, the Gelman Building, 2120 L Street,

~

i

l 4

N.W., Washington, D.C. 2055C and at the Local Public Document Room located at B. F. Jones Memorial Library, 663 Franklin Avenue, Aliquippa, Pennsylvania 15001.

Dated at Rockville, Maryland, this 3rd day of June,1991.

FOR THE NUCLEAR REGULA ORY COMMISS100

/

knbl Jo n F. Stolz, Director P oject Directorate 1-*

ivision of Reactor Projects - 1/II Office of Nuclear Reactor Regulation

w. -. -.

/

Distribution:

~~

Docket File

. /g. g%

UNITED STATES PD l-4 File yN-NUCLEAR REGULATORY COMMISSION

.y WASHINGTON D.C. 20555 e

/

June 3, 1991

...e e DOCKET NO. 50-334 Regulatory Publications Branch MEMORANDUM FOR:

Division of Freedom of information and Publications Services Of flee of Administration and Resources Management FROM:

Office of Nuclear Reactor Regulaton suaxCT:

fiEAVER VALLEY POWER STATION, UNIT 1 One signed original of the Federal Register Notice identif,ied below is enclosed for your transmtttal to the Office of the Federal Register for publication. Additional confotmed copies ( D

) of the Notice are enclosed for your use.

Notice of Receipt of Application f or Construction Permit (s) and Operating License (s).

Notice of Receipt of Partial Application for Construction Permst(s)and Facility License (s): Time for Submission of Views on Antitrust Matters.

Notice of Consideration of Issuance of Amendment to Facility Operating License. (Call with _. day insert date).

Notice of Receipt of Application for Facility Licensets). Notice of Availability of Applicant's Environmental Report; and Notice of Consideration of Issuance of Facility License (s) and Notice of Opportunity for Hearing.

Notice of Availability of NRC Draft / Final Environmental Statement.

Notice of Limited Work Authorizatlon.

Notice of Availability of Safety Evaluation Report.

Notice of Issuance of Construction Permit (s)

Notice of issuance of Facility Operating License (s) or Amendment (s)

Order.

Exemption.

l Notice of Granting Exemption.

A Environmental Assessment.

Notice of Preparation of Environmental Assessment.

Receipt of Petition for Director's Decision Under 10 CFR 2.206.

I issuance of Final Director's Decision Under 10 CFR 2.206.

l Other-I i

i i

i r

t

Enclosure:

Pdoject Directorate I-4 l

Ac stated l

i

Contact:

$,,Qrri s

~

pnone: X21440 i

PDI-4:LA

omes, y

ib s ul%N A AC a b 6/ 3 /91

one, wecy== sie noiaci ~=cu o 4o OFFICIAL RECORD COPY

--