V g
3h 8
s, y = m THE CINCINNATI GAS & ELECTRIC COMPANY W
6'c"f6WP1T 'fsta LOZ-83-0181 J. WILUAME JR SENIOR v1CE PRESIDENT NUCLEAR OPERA 7 TONS Docket No. 50-358 U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Attantion:
Mr. J.G. Keppler Regional Administrator Gentlemen:
RE:
WM. H. ZIMMER NUCLEAR POWER STATION - UNIT 1 10CFR50.55(e), ITEM M-97 JET PUMP INSTRUMENTATION BRACKET WELDS W.O.
57300, JOB E-5590, FILE NO. 956C, M-97 This letter constitutes an interim report concerning the subject condition initially reported to the Commission on September 22, 1983 as a potentially reportable deficiency under the requirements of 10CFR50.55(e).
Examination has revealed ~ that jet pump instrumentation bracket welds were not installed to the design drawing requirements.
Twenty-four of the thirty brackets are not completely welded.
CG&E is presently evaluating this item.
However, evaluation of the safety significance and resolution of the deficiency will require an extensive evaluation.
A follow-up report will be submitted by November 21, 1983.
We trust the above will be found acceptable as an 'nterim report under 10CFR50.55(e).
Very truly yours, THE CINCINNATI GAS & ELECTRIC COMPANY By
)// 4
/
. WILLIAMS, JR. I ENIOR VICE PRESI ENT 8310200098 831012
$h
\\ I
~
qfb PDR ADOCK 05000358 y f) s PDR
Mr. J.G. Keppler Regional Administrator October 12, 1983 LOZ-83-0181 Page 2 DJS/sfr cc:
NRC Office of Inspection & Enforcement Washington, D.C.
20555 NRC Senior Resident Site Inspector ATTN:
W.M. Hill NRC Zimmer Project Inspector, Region III ATTN:
E. R. Schweibinz l
l