ML20080G098
| ML20080G098 | |
| Person / Time | |
|---|---|
| Site: | River Bend |
| Issue date: | 08/29/1990 |
| From: | Hamilton J ENTERGY OPERATIONS, INC. |
| To: | ENTERGY OPERATIONS, INC. |
| References | |
| ED-90-694, NUDOCS 9502030289 | |
| Download: ML20080G098 (5) | |
Text
--
L/,
L RECEIVED SEP6 1990 M
MEM0RANDUM TO: Plant Manager August 29, 1990 FROM: J. R. Hamilton ED 694
<f(C.
SUBJECT:
CR Extension Request
- y' E\\
An interim disposition was written for CR #88-0012 based upon ib[/', k(
information provided by the applicable vendor.
Subsequent fire test failed to verify the vendor infonnation.
Engineering has a series of fire tests scheduled for October and November of this year which
'f.
g/ e '.
will establish the validity of the vendor's claim or provide a suitable alternative.
(
Fire watches remain active in the effected areas, satisfying the requirements of Tech. Specs.
Y Engineering has determined an extension to December 31, 1990 is required to properly disposition the CR based upon the new test Q
" Y results.
i.
g'f Please forward a copy of your response to me.
If you have any questions, please call me at ext. 4604.
E E.
Thank you, "Q
4 s
},
Ca i
f J. W./homilton t b Direttor-Design Engineering
>. c n
R4.ver Bend Nuclear Group e-
,J]$
h s.
BEL:RJK:me
{o f.
c.
ec: DCC bb MM-7/f/9D Plant Manager Concurrence
/
/ /
y, Return to DCC
{
q f b.
Copy of approved extensiton forwarded to Compliance by:
'f y Date:
A 9502030289 900829 5
i PDR ADDCK 05000458 F
')
i
CR NUMES _ N N/
=
- wm w
PAGE 2 OF
- 10. INVESTIGATION, ANALYSIS, CORRECTIVE ACTION, DISPOSITCN DETAILS. WORK INST THE.GMAL +( N-ac6 g T64M Aic w McTeg, Asp ou ggtg mwq gcqyg ag.,ggg, tW.
per',vtl. 9.GWV4 cF PEdfCEM62D %=et_, Sg. to cLeAe ceGTeuched, Oct2 u.ea aans.,woem me, acee w-eeama f tc.e TW6T6 cv cuf Beve. EN22.1Ei2. t>6CD LD\\M GTeE%6 4Kici l 6CI(AM.'
f VE.strS fuPOQCVAl. cf PCE4 CAT (CS.it @>S.ATtC*C. CCVIEC CF Veiuoc2-6vrpuet::
s ct+ M 14. Acw'-(GL6,TM W64/(4L Ncf6 419Z, M A41JAA4 EFFS 4T* G4 Matt?GLIAt h pt r A triOgt,s 9m Ww. VEaCCNE \\b PliS2FC9MM Ac ADO (tteMA.L '5ct$44t4.
5 bc 4,% 6, tsc TMtb D 19P89 tf(* 63 *
'l.he t F8 EO A 6 Lo TEY.in 4 uuTL.A. VtAnCkW2.
h set +4tc. AcuM5it is coa 4pcerE. SALT 6GdE "* '*'*T'"
'8' N " 'T P t" #"'"
- *.4 E JWb e fife tvd /T DRA.
I u,, -
g4 g
,-r n,,, _. ~ -
-~
%Arrctcma : Csu', JM 11, tW trwn. re nr V SG,Wl *y..'n yg p,
DISPOSITION ACTION T67 's JWN & IW Cr;7C1'. A; (s (
NONCONFORMANCE O YES O N O REWORK O REPAlR O USE AS.lS O N/A RECLASSIFY / SCRAP / RETURN TO SUPPUER (CIRCLE ONE) 10C O REJECT:
POTENTIAL 10CFR21 O YEs O h ASME O YES O N PREPARER DATE REVIEWER DATE
- 11. QA REVIEW DATE ANil REVIEW DATE
- 12. DISPOSITON ACTON COMPLETED: O YES O NO TAGS REMOVED: O YES O NO O N/
COMPLETED BY DATE
- 13. ROOT CAUSE AND CORRECTIVE ACTON TO PREVENT RECURRENCE
% cAo6C 16 AG, g oes.:rtt FL gD to Lgg. 6 l.cc5, tMPEcFee, N% TAU Anec F T6\\
uh.T69AA.\\,. TL.\\ \\9 CE.
cc A4= /AL.-ML"52.4EO 66f TAC tHW.P&'cric.c/;&n,TeR
)
g E E Q 0 % C-J O & #,-
- h. C.E4CCX OF THIG lee. Mo FoETM65E Gole 62tMiV L' g 6 C.T(o> > t6 Cd40 t GCD.
E CORRECTIVE AC P
D: %YES O NO COMPLETED BY
^
ATE M VERIFIED BY
<1 DATE COMPLIANCE
- 14. DOCUMENTATION INITIATED:
MWO MR Y
OTHER
- 15. FRC REVIEW O YES O NO SIGNATURE DATE MTG.NO.
- 16. CLOSE OUT w
I t
.t
{
PLANT MANAGER DATE INPO NETWORK ENTRY O YES J 17. CA REVIEW / CONCURRENCE DATE
a.._ _'W
?- 2M
~
wvERrTY LEVEL CONDITI N 7
6
, Mm.
REPOR s
to was D., C CR
- MO/J A g 3, u %
RIVER BEND STATik MANAGER SYSTEM NO. AND NAME enn4rv R br PMmuwV COMPONENT No.
1Txcoro COMPONENT NAME N=h A LOCATION (BLDG /ELEY) C*amtm. Ikw sc u - n L DISCOVERY (DATE/ TIME)
// L /#f 1300 EVENT DATEMME hacwa INITIATED BY:
O SHIFT SUPERVISOR R OTHER 'bd e Br*ve au mir / d o c.
NAME/DEP'
- 2. CONDITION DETECTION:
O OPERATIONAL ABNORMALITY O PREVENTIVE MAINT.
O CORRECTTVE MAINT.
5 OSSERVATION O ISI O SURVEILLANCE TESTING O SPECIAL INSPECTION O ALARM OOTHER (EXPLAIN)
REQUIRED REFERENCE (TITLE, DOCUMENT NO., REVISION, DATE, SECTION, ETC.)
B TECHNICAL SPECIFICAT)ON 3h M O 10CFR SECTION(S) i O PROCEDURE NO.
PARA:
R MWO NO.10M9 O RAD WORK PERMIT NO.
S OTHER (IDENTIFY) Sair 6. oex 3
Tnr Rrus M*vr Beru Remvo F T., Ter...
%cu, Aw s T.er-fa-n.
Ia%<WW IsAT A m 6y Spec. iV vio On Ter T m S w l~
2~a s m.4r2o,s /6vs.
A w.r.s 59ts. W Y'6 y
a Mondeg. 32 4 4tO-W 2 ~00YA E ORIGINATOR REQUESTS CLOSED COPY OF CCEN
- 4. ASSOCIATFfb.pOCp# PENT l}TED:
CK MWO NCW; W,
167 LOO PORM O OTHER ( EXPLAIN) l
~
7
- 5. NO. DEFICI' NCY' TAGS dA E
o T
- 6. PLANT CONDITION: i 2
3 4
8 (CIRCLE ONE) v RX POWER (MWTJ I
MWE
/MC RX PRE 88URE
/W RX LEVEL =D CORE FLOW
- ~ J V/ e "
ACTMTY IN PROGRESS
- 7. MATERIAUCOMPONENT CLASSIFICATION:
O O CLASS 1 (SAFETY RELATED)
O O CLASS 2 (NON.8AFETY RELATED)
O N/A
( 0 PROGRAM APPUCABLE (AUG D RADWASTE, FIRE PROTECTION, CAT ll SEISMC, M&TE)
E
- 8. REPORTABILITY DETERMINATION:
10 REPORT NOT REQUIRED D NRC PHONE NOTIFICATION MADE ON (DATEmME O LER. SECURITY OR SPECIAL REPORT REQUIRED BY (DATE O OTHER (PLANT MANAGER, EMER. PLAN NOTIFICATION, ETC.)
COMMENTS:
N SS SIGNATURE
]
bd U (DATE y
- 9. RESPONSIBILIDf ASSIGNMENTS:
INVESTIGATION, ANALYSIS AND CORRE ACTION ASSIGNED TO ako g
PREPARATION OF REGULATORY REPORT ASSIGNED TO COMMENTS:
W n
.1 PLANT MANAGER M
DATE NO
h/L Se_
i
+ L L,K L,c c a9 RECEIVED AN
- j. R'. -HMla.LiL 22 January 1988 Culf States Utilities Company River Bend Station P.O. Box 220 St. Francisville, LA 70775 Attention:
Mr. J. R. Hamilton Director Design Engineering
Subject:
File #228.410 letter of January 19, 1988
Dear Mr. Hamilton:
"here are two (2) one hour tests which we do not use the stress skin design. These I.T.L. Reports 82-11-241 and 83-5-472A, copies are enclosed.
These test reports have been used to justify the design outlined in the above referenced letter.
If you have any questions or require additional information, please contact me at 314-349-1233.
Yours truly, w w /,-
R.A. Lohman Manager Quality Assurance RAL/sas Enclosures THERMAL SCIENCE, INC.
- 2200 CASSENS CR.
- ST, LOUIS, MO 63026 + (314) 3491233 Telex: Domestic 44-2384
- Overseas 209901 Telecopier (314) 349-1207
(
o a
.a f
hi GULF STATES UTELITIES COMPAW nivta g(40 $f Af104 Pol? 0884CE SOE 223
$T 88AhC?$WILLE Lour $4ANA 7077$
A Ata CODI 604 03$ 6064 346 es$I January 19, 1988 i
RBG-27312 ID 0056 RESPWSE REQUIRED BY: 1/29/88 Mr. R. A. Ichman 2hermal Science, Inc.
2200 Cassens Drive St. Iou.is, 10 63026 Dear Mr. Ichnan File No. 228.410 Furnishily/ and Installation of Thermal Insulatian Outside the Drywell River Bend Statim - Unit 1 As discussad with Mr.
C.
Coonas, it is one-hour prefnrm=f thartrolag panels may be ut414 =d withour understanding TSI
?
the ribs and stress skin renoved.
This corxiition has been coverings in the Control 9'41 dig and has been reflectednoted on cable tray s
Report 88-0012.
Please confirm, in writing, the in condition one-hour rated, preformed panels installed with the stress skin and ribsacceptabili rur:oved.
Very truly yours, R. Hamilton Director -
Design Engineering PRS /O C/km River Bend Nuclear Group t
cc:
D. Beaucfarp SDC
,