ML20080E049
| ML20080E049 | |
| Person / Time | |
|---|---|
| Site: | Vogtle |
| Issue date: | 12/23/1994 |
| From: | Wilmoth M AFFILIATION NOT ASSIGNED, KOHN, KOHN & COLAPINTO, P.C. (FORMERLY KOHN & ASSOCIA |
| To: | Atomic Safety and Licensing Board Panel |
| Shared Package | |
| ML20080E043 | List: |
| References | |
| 93-671-01-OLA-3, 93-671-1-OLA-3, OLA-3, NUDOCS 9501100089 | |
| Download: ML20080E049 (4) | |
Text
.
i DOCKETED t
USNRC DecembeV 295C 239P3 35 0FFIE OF SECRETARJ; UNITED STATES OF AMERICA DOCKETING & LE:,vlC NUCLEAR REGULATORY COMMISSION E
ATOMIC SAFETY AND LICENSING BOARD
)
i In the Matter of
)
)
Docket Nos. 50-424-OLA-3 GEORGIA POWER COMPANY
)
50-425-OLA-3 at al,
)
t
)
Re: License Amendment I
(Vogtle Electric Generating
)
(transfer to Southern Nuclear)
'I Plant, Unit 1 and Unit 2)
)
)
ASLBP No. 93-671-01-OLA-3 INTERVENOR'S MOTION FOR SUBPOENA OF JAMES JOINER t
Pursuant to 10 C.F.R.
- 52. 720 (a), Intervenor, Allen Mosbaugh moves the Licensing Board to issue a subpoena to James Joiner, Esq., to appear and testify at the illegal license transfer hearing on Monday, January 9, 1994, at 2:00 p.m.,
in Atlanta, t
Georgia at a place to be determined by'the Board.
Intervenor
}
makes this request because this witness possesses knowledge relevant to Intervenor's prefiled issues.
Intervenor will file a cross examination plan, in camera, simultaneously with this motion which will explain what testimony Intervenor plans to i
t illicit from this witness as well as the relevancy of his l
testimony to this proceeding.
For the reasons stated in the cross-examination plan Intervenor' requests that this motion be i
i granted.
l (Signature on next page]
l 9501100009 941223 i
PDR ADOCK 05000424 9
i d
Respectfully-submitted,
$!c7j6TM Mh'o S Michael D. Kohn i
Mary' Jane Wilmoth Kohn, Kohn & Colapinto, P.C.
517 Florida Ave.,
N.W.
Washington, D.C.
20001' (202) 234-4663 CERTIFICATE OF SERVICE I hereby certify that-the above motion was served via~ hand-delivery on December 23, 1994, upon the persons listed in the attached Service List' (except service by federal express. is indicated by "*").
]d % &f7w (,J()n u k By:
I Mary Jape Wilmoth' KOHN, KOHN & COLAPINTO,._P.C.
517 Florida Ave.,
N.W.
Washington, D.C.
20001 (202) 234-4663 C:\\ FILES \\301\\SU82.Wif CC O 1 d
h-75 a
Om tDd o b
C~ O -
xy a
my D
( *-
N M
T E.1{=]
OM b#i 3
o hf.Il o
2:i;"
Ui pi2 W
2
'~+V w-n.
--- - - - - - --s -----
a
- _ ~
UNITED STATES OF AMERICA j
NUCLEAR REGULATORY COMMISSION i
ATOMIC SAFETY AND LICENSING BOARD l
?
)-
i In the Matter of
)
i
)
Docket Nos. 50-424-OLA-3
[
GEORGIA POWER COMPANY
)
50-425-OLA-3.
rJ; al,
)
)
Re: Licenae Amendment (Vogtle Electric Generating
)
-(transfer to Southern Nuclear) i Plant,' Unit 1 and Unit 2)
)
{
)
ASLBP No. 93-671-01-OLA-3 SERVICE LIST Administrative Judge
- Administrative Judge t
Peter B. Bloch, Chair James H. Carpenter Atomic Safety and Licensing Board 933 Green Point Drive U.S. Nuclear Regulatory Commission Oyster Point Washington, D.C.
20555 Sunset Beach, NC 28468' l
Administrative Judge Charles A..Barth, Esq.
l Thomas D. Murphy Office of General Counsel Atomic Safety and Licensing Board U.S. N.R.C U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Washington, D.C.
20555 i
Ernest L.
Blake, Jr.
i David R. Lewis SHAW, PITTMAN, POTTS &
TROWBRIDGE 2300 N Street, N.W.
1 Washington, D.C.
20037 j
office of the Secretary l
Attn: Docketing and Service l
U.S. Nuclear Regulatory Commission l
Washington, D.C.
20555 '
Office of Commission Appellate Adjudication U.S. Nuclear Regulatory Commission Washington, D.C.
20555 I
ii civiutsu0hCEU.US l
i i
I i
December 23, 1994 UNITED STATES OF AMERICA o
NUCLEAR REGULATORY COMMISSION
.t ATOMIC SAFETY AND LICENSING BOARD
)
In the Matter of
)
)
Docket Nos. 50-424-OLA-3 GEORGIA POWER COMPANY-
)
50-425-OLA-3 31 gL.,
)
)
Re: License Amendment
.(Vogtle Electric Generating
)
(transfer to Southern Nuclear)
I Plant, Unit 1 and Unit 2)
)
)
ASLBP No. 93-671-01-OLA-3 J
SUBPOENA In accordance with section 161(c) of the Atomic Energy Act, l
42 U.S.C. S2201 (c) and 10 C.F.R. 52.720, James Joiner, Esq. is hereby ordered to appear at 2:00 p.m. on January 9, 1995 in Atlanta, Georgia, at a place to be determined by the Board, to-appear and testify in the illegal license transfer portion of.
i this proceeding.
f On motion made promptly, and in any event received on or before January 9, 1995, and on notice delivered to Intervenor's l
counsel on or before that date, this Atomic Safety and Licensing l
Board (or if the Licensing Board is unavailable, the Commission) j may (1) quash or modify the subpoena if it is unreasonable or requires evidence not relevant to any matter or issue, or (2) condition denial of the motion on just and reasonable terms.
i Peter B. Bloch, Chair Dated at Rockville, Maryland this day of
- 1994, i
-