GPU Nuclear Corporation NggIgf Post Office Box 480 Route 441 South Middletown, Pennsylvania 17057-0191 717 944 7621 TELEX 84 2386 Writer's Direct Dial Number:

January 16, 1984 5211-84-2011 Office of Nuclear Reactor Regulation Attn: John F. Stolz, Chief Operating Reactors Branch No. 4 U. S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Sir:

Three Mile Island Nuclear Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Restart Readiness Schedule This letter provides an update to our letter dated December 1, 1983.

The results of the second Flag 2 Management review meeting held on January 12, 1984, indicated that the plant is now ready for final heatup. Management also concluded that the plant was ready to go critical upon completion of the identified prerequisites.

(A detailed report of management's review will be forwarded by separate correspondence.)

Completion of the remaining prerequisites to going critical should occur by the end of January and the plant will be ready to go critical by February 1,1984 as projected on the attached schedule.

j The above schedule, of course, depends upon receiving NRC approval of our December 21, 1983 request for heatup and favorable Commission decisions on the restart order and final steam generator Technical Specification approval.

Sincerely, H. D. Hukill Director, TMI-l HDH:CWS:vj f Attachment 8401240251 840116 PDR ADOCK 05000289 p

PDR M

GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation g

'lI

R SUENITTED BY:

O

&Lgig(

)

) M*

  • b+

Baseline Revision 1

Date:. Dec. 16, 1983 I

R. P. Adamlak r

N gr. Plans a Programs Dept. mI-1 Revision No.

2 Date:

Jan. 16,' 1984 I

g.,g4 34 APPROVED BY:

1 tpdate No.

O Date:

H. D. Hukill n T?. & D. rector NI-1 R. J. Toole l-Ik 4T Legend.

Director NI-l GPU PAJCLEAR CORPORATION NI-l MASTER RESTART SCKDLLE Baseline MAJOR EVOLUTIONS SlM4ARY Forecast

+mmmo I

I i

1 I

i

.I I

DESM IPTION I DECEMBER l

JAFUARY l

FEBRUARY MARCH I

APRIL l

4AY l

JJfC l

J.R Y I

i I

I I

I I

i i

l-~l l l

I I

I I

I I

I 211 i

l I

l l

l 1

Il i

I l

l l

l l

l HOT l

ll l

l l

l l--- l l Indicates 1

FUNCTIONAL Baselinel 171-1151 l

l l

l TEST l Complete T

T-1 I

i 1

1 I

I Management i

I Remaining i

l l

I i

1 l

i Review Point l l Prerequisites l l

l l

l l

l l

'(Flag) l Forecast m+mm+m+mlI3 HIBl +1N nil l

I l

l l

ll l

T- -- ~ IT I

I I

I I

i I

I il l

I I

I l

I i

11 1

I I

i l

ZERO l

1 J ll Criticality i I

l l

POWER l

l 1101-1151 l l 02/01/84 Forecast l

l l

l 1

I I

I I

physics I

I T

lo TEST l

l 1

fil+lll l

l l

l l

1 1

I l-T I

I I

I I

i l

i I

I I

I l

i I

I 1

I I

I I

I I

I I

I I

I I

I I

l-I H

!I I

I I

I I

I I

l l

1 1

I I

I I

I l

I i

i l

i I

I i

1 1

I I

l l

I 4

I I

I I

I I

I i

POWER l

l lI51-INI 1711-lEl 1251-1311 l

l l

ESCALATION I

i l

1 l,

~l I

l l

TEST l

l l

l 48% Power 1- - l 75% Power l-l 100% Power l

l I

I I

I Operator i 31 Operator 1 41 Operations 1

I I

I l

t Training

-I Training li l

i i

l i

13l+113l m. m lI1l+119l m m m ilgiul231 l l

1 I

I I

I

-I I

-~

- 1 I

I I

I I

I I

I I

I I

I I

i 1

l l

l l

l l

l Eddy Current l I

I I

I I

I I

I Ntar i

EDDY CURRENT l

l l

l l

50% Power + 120 Days l

- - - -- - Illumm+m+lli TESTIto l

I l'

l l--------------i 1 4 wks (+-1)

T l

I i

i i

l l

1 1

I I

I I

l l

l l

l 6

PLANS & PROGRMS DEPT. NI-l _

a NOTE: This exhibit is supported by project 2 detail test sequence Dated: January 16, 1984 u---