o Commonwealth Edison l

. On) First Nation-1 Ptart. Chicago. litinois i

j Address Reply to: Post Othee Box 767

,/ Chicago. llhnoi:s 6M90 January 11, 1984 Mr. Harold R. Denton, Director Of fice of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

LaSalle County Station Units 1 and 2 External Line Breaks Bounded By 10 CFR 100 Guidelines (Mul.tlple Failure Concerns)

NRC Docket Nos. 50-373 and 50-374 References (a):

C.

W.

Schroeder letter to H. R. Denton dated October 27, 1983; Response to Special Scenario on Turbine Control System Failure of Non-Safety Equipment (Multiple Failure Concerns).

(b):

Telecon from Dr.

A. Bournia to C.

W.

Schroeder and G. R. Crane on December 1, 1983; Requesting Additional Information.

(c):

C.

W. Schroeder letter to H. R. Denton dated December 1, 1983, (Multiple Failure Concerns).

Dear Mr. Denton:

The purpose of this letter is to retransmit Reference (c) with a typographical error corrected.

Reference (a) responded to the special scenario for an HELB on a feedwater heater line in the turbine building and its effects on a non-safety related control systems such as the turbine controls.

The NSSS vendor's evsluation with the ODYN code indicated that the peak vessel pressures, peak heat fluxes, and peak neutron fluxes are acceptable and non-bounding.

In the auto-flux control mode, feedwater flow adjustments keep the fuel clad temperatures low and MCPR remains in the acceptable regime.

In the manual mode of feedwater control, this scenario results in a delta CPR of 0.25 with the MCPR attaining 1.00 1 0.02 depending upon the ODYN option used to compute it.

This indicates that some fuel rods (0.4 to 1.1 percent) may enter partial transition boiling.

No fuel damage (perforations) is expected however because the peak cladding temperature remains belows 10000F.

No fission products are expected to be released

'n t he f u e l.

By Reference (b), NRC staff requested a

.1ve comparison of the offsite consequences from a steam line break outside primary containment (in particular this special scenario), with the 10 CFR 100 guidelines.

The FSAR 15.6.4 event is a steam line break outside containment with an assumed release of 14,000 lb steam and 86,000 lb 11guld reactor coolant 8401230288 840111 PDR ADOCK 05000373 P

PDR

$f t 0

H. R. Denton January 11, 1984

(

70 C1 of Iodines and 7.5 C1 noble gas released).

Using the NRC conser-vative model to estimate doses, the following results were determined for this event:

Whole Body Thyroid dose (R)

Exclusion Boundary 3.5 X 10-2 3.6 x 10-4 Low Population Zone 1 5 x 10-5 1.4 x 10-3 The FSAR 15.6.6 representation on a feedwater line break over a 3 to 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> period (outside containment) with an assumed release of 788,000 lbs of water, of which 165,000 lbs flash to steam, releases only 0.096 Ci of Iodine and trivial noble gas.

This leads to NRC conservative potential dose of roughly 10-8 rad thyroid or whole body at the exclusion boundary or the L PZ distances.

These two events envelope the potential

' lease from a feedwater heater line break in the turbine building basement as postulated in the NRR special scenario.

Each o f the FSAR events resulted in insignificant lodine and noble gas releases, hence the potential radiological insult associated with the special scenario event is trivial with respect to 10 CFR 100 guidelines.

To the best of my knowledge and belief the statements contained herein are true and correct.

In some respects these statements are not based on my personal knowledge but upon information furnished by other l

Commonwealuh Edison employees and contractor employees.

Such information has been reviewed in accordance with Company practice and I believe it to be reliable.

If you have any further questions regarding this matter, please contact this office.

Very truly yours, s )so } W C. W. Schroeder Nuclear Licensing Administrator 1m cc:

B.R. Shelton L. O. De1 George T. E. Watts H. R. Pe rfer - GE/ San Jose J. Gouvas (S&L)

NRC Resident Inspector - LSCS 7981N