ML20079F889

From kanterella
Jump to navigation Jump to search
Forwards Revised Environ Parameters & TMI-Related Equipment, Containing Revised Environ Svc Conditions within Reactor Bldg,Sys Component Evaluation Worksheets & Revised Ref Documents Master List,Per NRC 820118 Request.W/O Encl
ML20079F889
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 06/02/1982
From: Bayne J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: Vassallo D
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737 JPN-82-47, NUDOCS 8206080252
Download: ML20079F889 (2)


Text

.

l 1

i POWER AUTHORITY OF THE STATE OF NEW YORK 1

(

10 CoLUMaus CIRCLE NEW YORK. N. Y.10019 12121 397 6200 GEORGET BERRY l

TRUSTEES Ort n 4 TING O F FIC E R

"".'hc"r*v'.v"c.

",".'":"=c"l""""

GEORGE L iNGALLS vics caasassaN JOSEPH R. SC IEDER gig;of,a r. caise niewaRo u rLYuu June 2, 1982 LERoy w. SiscLaiR aosERT i uiLLouz' F R E D E RIC K R. CLARK JPN-82-47

.'2,{le,,,'i.I.le"f"

THOM AS R. FREY sa nah cowhetL Director of Nuclear Reactor Regulation U.S. Nuclear Reglatory Commission Washington, D.C.

20555 Attention:

Mr. Domenic B. Vassallo, Chief Operating Reactors Branch Ib. 2 Division of Licensing

Subject:

James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 Environmental Qualification of Safety-Related Electrical Bluipment Request for Additional Information

Reference:

1.

P. J. Polk (NRC) to G. T. Berry (PASNY) dated January 18, 1982.

2.

J. P. Bayne (PASNY) to D. B. Vassalo (NHC) dated February 5, 1982 (JPN-82-16).

Dear Sir:

In further response to your January 18, 1982 letter (Reference 1),

the Authority hereby submits the enclosed document entitled " Revised Environmental Parameters and 'INI Related Equipment." This document contains revised environmental service conditions within the Reactor Building, System Component Evaluation Worksheets (SCEW) for identified TMI Action Plan equipment and a revised Reference Documents Master List.

In specific response to the items contained in Section B of Reference 1, the following explanatory remarks apply:

1.

The information required in items 1.a. through 1.e has been provided in the SCai's contained in the enclosed document.

M 8206000252 820602 d

h DR ADOCK 05000

_ _ _ _ _ _ _ _ _ _ _ _ _j

l

! 2.

One copy of the qualification documents applicable to this submittal, as well as one copy of the " Revised Environmental Parameters and TMI Related RIuipment" document, are being sent directly to Mr. C. J. Crane of the Franklin Research Center by copy of this letter. Some qualification documents listed in the revised Reference Master List are not included in the submittal.

Wey will be transmitted to Mr. Crane in the very near future.

These qualification documents are considered proprietary and should be treated as such.

3.

We Power Authority has endorsed an Owner's Group position, or has requested an extension of an implementation date, for certain NUREG-0737 requirements.

In those cases, the requested informa-tion has been provided in numerous previous submittals to the NRC.

If you have any further questions, please contact Mr. J. A. Gray, Jr. of my staff.

Very truly yours, J

nior Vice P sident

, Nuclear Generation w/ attachments:

Mr. Cyril J. Crane Franklin Research Center he Parkway at Twentieth Street Philadelphia, PA 19103 w/o attachments: Mr. J. Linville Resident Inspector U.S. Nuclear Regulatory Comission P. O. Box 136 Lycoming, New York 13093 Mr. Ron Barton United Engineers & Constructors, Inc.

30 S. 17th Street Philadelphia, PA 19101 1

_J