Letter Sequence Request |
---|
|
|
MONTHYEARML20079D3941991-06-28028 June 1991 Suppls 900823 Application for Amends to Licenses DPR-53 & DPR-69 Re Deletion of Specific Titles for Members of Plant Operations & Safety Review Committee & Use of Procedure Review Committee or Qualified Reviewers Project stage: Request 1991-06-28
[Table View] |
|
---|
Category:OPERATING LICENSES-APPLIATION TO AMEND-RENEW EXISTING
MONTHYEARML20211J9861999-09-0101 September 1999 Application for Amends to Licenses DPR-53 & DPR-69,changing Definition of Azimuthal Power Tilt in TS 1.1,correcting Peak Linear Heat Rate Safety Limit in TS 2.1.1.2 & Correcting Dc Voltage Range Listed in Surveillance Requirement 3.3.6.2 ML20211G7591999-08-27027 August 1999 Application for Amends to Licenses DPR-53 & DPR-69,revising TS 3.7.13 to Allow Placement of One or More Fuel Assemblies on SFP Rack Spacers to Support Fuel Reconstruction Activities During Continuing Fuel Assembly Movement ML20196E2101998-11-30030 November 1998 Application for Amends to Licenses DPR-53 & DPR-69,allowing Repair of Defective SG Tubes with leak-limiting Alloy 800 sleeves.Non-proprietary Rev 03-P to CEN-633-NP & Proprietary Rev 03-P to CEN-633-P,encl.Proprietary Info Withheld ML20195K3711998-11-20020 November 1998 Application for Amends to Licenses DPR-53 & DPR-69,removing TS Originally Developed from Reg Guide 1.35 & Implementing Requirements of 1992 Edition Through 1992 Addenda of ASME B&PV Code Section Xi,Subsections IWE & Iwl,Per 10CFR50.55a ML20196A6001998-11-20020 November 1998 Application for Amends to Licenses DPR-53 & DPR-69, Requesting Indirect Transfer of Control,Pursuant to 10CFR72.50,of Matls License SNM-2505 for Plant ISFSI ML20195J7131998-11-19019 November 1998 Application for Amends to Licenses DPR-53 & DPR-69,revising TS 3.7.6, SWS, by Adding One SWS Heat Exchanger Inoperable as New Condition for LCO 3.7.6 ML20154N1861998-10-16016 October 1998 Application for Amends to Licenses DPR-53 & DPR-69 to Incorporate Revised TS 3.3.1 & 3.3.2 to Clarify Inconsistency Between TS Wording & Design Bases as Described in TS Bases & UFSAR ML20236S1341998-07-20020 July 1998 Application for Amend to License DPR-59,implementing Mod That Involves Replacing SW Heat Exchangers W/New Plate & Frame Heat Exchangers Having Increased Thermal Performance Capability ML20236S5591998-07-20020 July 1998 Application for Amend to Licenses DPR-53 & DPR-69,providing Alternate Cooling Water Supply to Maintain EDGs Operability During 1999 Refueling Outage ML20198K9591998-01-12012 January 1998 Rev 11 to 961204 Application for Amends to Licenses DPR-53 & DPR-69,converting to Improved Sts,Per NUREG-1432 ML20217K6591997-10-22022 October 1997 Application for Amends to Licenses DPR-53 & DPR-69, Incorporating Both Steady State & Transient Degraded Voltage Setpoints Into Tss,As Opposed to Current Single Degraded Voltage Setpoint ML20211J2691997-10-0202 October 1997 Application for Amend to License DPR-53,revising TS to Reflect New Electrical Capacity for 1B Edg.Significant Hazards Considerations Associated W/Change Have Been Evaluated ML20141F9181997-05-16016 May 1997 Application for Amend to License DPR-53,implementing Mod Involves Replacing Service Water Heat Exchangers W/New Plate & Frame Heat Exchangers Having Increased Thermal Performance Capability ML20136A9751997-03-0606 March 1997 Application for Amend to License DPR-69,allowing Mod to Unit 2 SW Sys Which Constitutes Unreviewed Safety Question in 10CFR50.59 ML20134D2871997-01-31031 January 1997 Application for Amends to Licenses DPR-53 & DPR-69,changing to Support Larger Number of Plugged SG Tubes for Future Operating Cycles ML20149M0801996-12-0404 December 1996 Application for Amends to Licenses DPR-53 & DPR-69,revising TSs to Be Generally Consistent w/NUREG-1432,Rev 1,thus Replacing 2 Current Sets of TSs W/Single Set Applicable to Both Units ML20135A5171996-11-26026 November 1996 Application for Amends to Licenses DPR-53 & DPR-69,adopting Option B of 10CFR50,App J,To Require Types B & C Containment Leakage Rate Testing to Be Performed on performance-based Testing Schedule ML20128H5971996-10-0303 October 1996 Application for Amend to License DPR-53,changing Provisions for Receiving,Possessing & Using Byproduct,Source & Special Nuclear Matl at Plant ML20117L7801996-09-10010 September 1996 Application for Amends to Licenses DPR-53 & DPR-69 Requesting Extension of ESFAS Automatic Actuation Logic Surveillance from Monthly to Quarterly ML20116F8231996-08-0101 August 1996 Application for Amends to Licenses DPR-53 & DPR-69,allowing Use of Blind Flanges During Modes 1-4 in Plant Containment Purge Sys ML20116E3571996-07-26026 July 1996 Application for Amends to Licenses DPR-53 & DPR-69,to Repair Defective SG Tubes by Electrosleeving ML20117J1911996-05-28028 May 1996 Application for Amend to License DPR-53 & DPR-69,requesting Exigent Amends to Allow Installation of Proposed Modification of Unit 1 & 2 Service Water (SRW) Systems ML20101K5911996-03-28028 March 1996 Application for Amends to Licenses DPR-53 & DPR-69, Requesting to Reduce Moderator Temp Coefficient Limit Shown on TS Figure 3.1.1-1 ML20101D8211996-03-15015 March 1996 Suppl to LAR Re Sleeving Option for SG Tube Repair.Proposes Rev to TS Wording in Attachments (A-3) & (A-4) by Removing Generic Ref to Technical Repts & Replace W/Ref to Specfic Approved Repts ML20096D4291996-01-16016 January 1996 Application for Amends to Licenses DPR-53 & DPR-69,adopting Option B of 10CFR50,App J to Require Type a Containment Lrt to Be Performed on performance-based Testing Schedule ML20095K2701995-12-21021 December 1995 Application for Amends to Licenses DPR-53 & DPR-59, Requesting Temporary Exemption & TS Change to Allow Placement of Four Lead Test Fuel Assemblies in Unit 1 Reactor Core During Cycles 13,14 & 15 ML20095C7421995-12-0707 December 1995 Application for Amends to Licenses DPR-53 & DPR-69 to Add Analysis Technique to List of Approved Core Operating Limits Analytical Methods in TS for Plant ML20094S1481995-11-30030 November 1995 Application for Amends to Licenses DPR-53 & DPR-59,allowing Installation of Tube Sleeves as Alternative to Plugging to Repair Defective SG Tubes ML20094D6131995-11-0101 November 1995 Application for Amends to Licenses DPR-53 & DPR-69,upgrading ESF Electrical Sys at Plant to Provide Addl Protection from Loss of Electrical Power ML20093M4141995-10-20020 October 1995 Application for Amend to License DPR-53,extending 18-month Surveillances to 960331 ML20098C0661995-10-0202 October 1995 Application for Amend to License DPR-69,requesting Extension of Unit 2 TS Action Statements 3.7.6.1.a & B from 7 Days to 30 Days for Loss of Emergency Power to Support 1996 Refueling Outage ML20086N2341995-07-13013 July 1995 Application for Amends to Licenses DPR-53 & DPR-69,revising TS 5.2.1 to Allow Use of Lead Fuel Assemblies & Requests Temporary Exemption from Requirements of 10CFR50.46, 10CFR50.44 & 10CFR50,App K for Ccnpp Unit 1 ML20085D4901995-06-0909 June 1995 Application for Amends to Licenses DPR-53 & DPR-69, Implementing Changes to Radiological Effluent TS Per GL 89-01 ML20084R0111995-06-0606 June 1995 Application for Amends to Licenses DPR-53 & DPR-69.Amends Would Revise TSs to Extend Certain 18-month Frequency Surveillances to Refueling Interval ML20084P9681995-06-0202 June 1995 Application for Amends to Licenses DPR-53 & DPR-69,proposing TS Re Pressurizer Safety Valves Lift Tolerance ML20087H9141995-04-28028 April 1995 Application for Emergency Amend to License DPR-53.Amend Would Revise CREVS TSs to Provide an Extension of Allowed Outage Time ML20081D0411995-03-15015 March 1995 Application for Amends to Licenses DPR-53 & DPR-69 to Reformat Current Administrative Controls Section & Relocate Several Requirements to Other Documents & Programs ML20079A5771995-02-24024 February 1995 Application for Amend to License DPR-69,allowing Extension of Interval Between First & Second Type a Test During Second Service Period & Extension of Second Service Period to 12 Years to Coincide w/1999 Plant Inservice Insp ML20078G8161995-01-31031 January 1995 Application for Amends to Licenses DPR-53 & DPR-69,revising TS to Increase Min Amount of Trisodium Phosphate Dodecahydrate Verified in TS Surveillance ML20073G2401994-09-23023 September 1994 Application for Amends to Licenses DPR-53 & DPR-69,allowing one-time Extension from 7 to 14 Days of AOT for Dedicated Class 1E Emergency Power Source During 1995 Refueling Outage ML20071P4421994-08-0404 August 1994 Application for Amend to License DPR-53 & DPR-69,eliminating TS 3/4.3.3.3 for Seismic Monitoring Instrumentation, Relocating Requirements for Operation & Testing of Seismic Monitoring Instrumentation to Plant Updated FSAR ML20149E8321994-08-0202 August 1994 Application for Amends to Licenses DPR-53 & DPR-69,revising Surveillances Associated W/Edgs to Add High Crankcase Pressure to EDG Trips Which Are Verified to Be Automatically Bypassed on Safety Injection Actuation Signal ML20071N2961994-08-0202 August 1994 Application for Amends to Licenses DPR-53 & DPR-69, Incorporating TS 3.9.1, Refueling Operations,Boron Concentration ML20069H6471994-06-0808 June 1994 Application for Amends to Licenses DPR-53 & DPR-69,revising TS 4.6.2.2.d,extending Surveillance Interval from 18 to 24 Months ML20069H6191994-06-0808 June 1994 Application for Amends to Licenses DPR-53 & DPR-69,revising TS 4.8.1.1.1.b,extending Alternate Offsite Power Circuit Surveillance Frequency from 18 to 24 Months ML20069H6311994-06-0808 June 1994 Application for Amends to Licenses DPR-53 & DPR-69,revising TS 4.7.1.2.c,extending Interval for Three Auxiliary Feedwater Surveillance Requirements from 18 to 24 Months ML20069C3921994-05-27027 May 1994 Application for Amend to License DPR-69,revising Heatup & Cooldown Curves & LTOP Controls for Unit 2 to Support Mods to LTOP Sys Scheduled for Spring 1995 Refueling Outage ML20069C2801994-05-27027 May 1994 Application for Amends to Licenses DPR-53 & DPR-69, Revising TS Surveillance Test Interval from Monthly to Quarterly for Several Channel Functional Tests for RPS & ESFAS ML20058K2831993-12-0808 December 1993 Application for Amends to Licenses DPR-53 & DPR-69,revising TS Associated W/Content of Design Features ML20059L4051993-11-11011 November 1993 Application for Amends to Licenses DPR-53 & DPR-69,revising TSs by Relocating Tables of Response Time Limits for Reactor Protection Sys & ESFAS Instruments from TSs to Updated FSAR 1999-09-01
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARML20211J9861999-09-0101 September 1999 Application for Amends to Licenses DPR-53 & DPR-69,changing Definition of Azimuthal Power Tilt in TS 1.1,correcting Peak Linear Heat Rate Safety Limit in TS 2.1.1.2 & Correcting Dc Voltage Range Listed in Surveillance Requirement 3.3.6.2 ML20211G7591999-08-27027 August 1999 Application for Amends to Licenses DPR-53 & DPR-69,revising TS 3.7.13 to Allow Placement of One or More Fuel Assemblies on SFP Rack Spacers to Support Fuel Reconstruction Activities During Continuing Fuel Assembly Movement ML20196E2101998-11-30030 November 1998 Application for Amends to Licenses DPR-53 & DPR-69,allowing Repair of Defective SG Tubes with leak-limiting Alloy 800 sleeves.Non-proprietary Rev 03-P to CEN-633-NP & Proprietary Rev 03-P to CEN-633-P,encl.Proprietary Info Withheld ML20195K3711998-11-20020 November 1998 Application for Amends to Licenses DPR-53 & DPR-69,removing TS Originally Developed from Reg Guide 1.35 & Implementing Requirements of 1992 Edition Through 1992 Addenda of ASME B&PV Code Section Xi,Subsections IWE & Iwl,Per 10CFR50.55a ML20196A6001998-11-20020 November 1998 Application for Amends to Licenses DPR-53 & DPR-69, Requesting Indirect Transfer of Control,Pursuant to 10CFR72.50,of Matls License SNM-2505 for Plant ISFSI ML20195J7131998-11-19019 November 1998 Application for Amends to Licenses DPR-53 & DPR-69,revising TS 3.7.6, SWS, by Adding One SWS Heat Exchanger Inoperable as New Condition for LCO 3.7.6 ML20154N1861998-10-16016 October 1998 Application for Amends to Licenses DPR-53 & DPR-69 to Incorporate Revised TS 3.3.1 & 3.3.2 to Clarify Inconsistency Between TS Wording & Design Bases as Described in TS Bases & UFSAR ML20236S1341998-07-20020 July 1998 Application for Amend to License DPR-59,implementing Mod That Involves Replacing SW Heat Exchangers W/New Plate & Frame Heat Exchangers Having Increased Thermal Performance Capability ML20236S5591998-07-20020 July 1998 Application for Amend to Licenses DPR-53 & DPR-69,providing Alternate Cooling Water Supply to Maintain EDGs Operability During 1999 Refueling Outage ML20198K9591998-01-12012 January 1998 Rev 11 to 961204 Application for Amends to Licenses DPR-53 & DPR-69,converting to Improved Sts,Per NUREG-1432 ML20217K6591997-10-22022 October 1997 Application for Amends to Licenses DPR-53 & DPR-69, Incorporating Both Steady State & Transient Degraded Voltage Setpoints Into Tss,As Opposed to Current Single Degraded Voltage Setpoint ML20211J2691997-10-0202 October 1997 Application for Amend to License DPR-53,revising TS to Reflect New Electrical Capacity for 1B Edg.Significant Hazards Considerations Associated W/Change Have Been Evaluated ML20141F9181997-05-16016 May 1997 Application for Amend to License DPR-53,implementing Mod Involves Replacing Service Water Heat Exchangers W/New Plate & Frame Heat Exchangers Having Increased Thermal Performance Capability ML20136A9751997-03-0606 March 1997 Application for Amend to License DPR-69,allowing Mod to Unit 2 SW Sys Which Constitutes Unreviewed Safety Question in 10CFR50.59 ML20134D2871997-01-31031 January 1997 Application for Amends to Licenses DPR-53 & DPR-69,changing to Support Larger Number of Plugged SG Tubes for Future Operating Cycles ML20149M0801996-12-0404 December 1996 Application for Amends to Licenses DPR-53 & DPR-69,revising TSs to Be Generally Consistent w/NUREG-1432,Rev 1,thus Replacing 2 Current Sets of TSs W/Single Set Applicable to Both Units ML20135A5171996-11-26026 November 1996 Application for Amends to Licenses DPR-53 & DPR-69,adopting Option B of 10CFR50,App J,To Require Types B & C Containment Leakage Rate Testing to Be Performed on performance-based Testing Schedule ML20128H5971996-10-0303 October 1996 Application for Amend to License DPR-53,changing Provisions for Receiving,Possessing & Using Byproduct,Source & Special Nuclear Matl at Plant ML20117L7801996-09-10010 September 1996 Application for Amends to Licenses DPR-53 & DPR-69 Requesting Extension of ESFAS Automatic Actuation Logic Surveillance from Monthly to Quarterly ML20116F8231996-08-0101 August 1996 Application for Amends to Licenses DPR-53 & DPR-69,allowing Use of Blind Flanges During Modes 1-4 in Plant Containment Purge Sys ML20116E3571996-07-26026 July 1996 Application for Amends to Licenses DPR-53 & DPR-69,to Repair Defective SG Tubes by Electrosleeving ML20117J1911996-05-28028 May 1996 Application for Amend to License DPR-53 & DPR-69,requesting Exigent Amends to Allow Installation of Proposed Modification of Unit 1 & 2 Service Water (SRW) Systems ML20101K5911996-03-28028 March 1996 Application for Amends to Licenses DPR-53 & DPR-69, Requesting to Reduce Moderator Temp Coefficient Limit Shown on TS Figure 3.1.1-1 ML20101D8211996-03-15015 March 1996 Suppl to LAR Re Sleeving Option for SG Tube Repair.Proposes Rev to TS Wording in Attachments (A-3) & (A-4) by Removing Generic Ref to Technical Repts & Replace W/Ref to Specfic Approved Repts ML20096D4291996-01-16016 January 1996 Application for Amends to Licenses DPR-53 & DPR-69,adopting Option B of 10CFR50,App J to Require Type a Containment Lrt to Be Performed on performance-based Testing Schedule ML20095K2701995-12-21021 December 1995 Application for Amends to Licenses DPR-53 & DPR-59, Requesting Temporary Exemption & TS Change to Allow Placement of Four Lead Test Fuel Assemblies in Unit 1 Reactor Core During Cycles 13,14 & 15 ML20095C7421995-12-0707 December 1995 Application for Amends to Licenses DPR-53 & DPR-69 to Add Analysis Technique to List of Approved Core Operating Limits Analytical Methods in TS for Plant ML20094S1481995-11-30030 November 1995 Application for Amends to Licenses DPR-53 & DPR-59,allowing Installation of Tube Sleeves as Alternative to Plugging to Repair Defective SG Tubes ML20094D6131995-11-0101 November 1995 Application for Amends to Licenses DPR-53 & DPR-69,upgrading ESF Electrical Sys at Plant to Provide Addl Protection from Loss of Electrical Power ML20093M4141995-10-20020 October 1995 Application for Amend to License DPR-53,extending 18-month Surveillances to 960331 ML20098C0661995-10-0202 October 1995 Application for Amend to License DPR-69,requesting Extension of Unit 2 TS Action Statements 3.7.6.1.a & B from 7 Days to 30 Days for Loss of Emergency Power to Support 1996 Refueling Outage ML20086N2341995-07-13013 July 1995 Application for Amends to Licenses DPR-53 & DPR-69,revising TS 5.2.1 to Allow Use of Lead Fuel Assemblies & Requests Temporary Exemption from Requirements of 10CFR50.46, 10CFR50.44 & 10CFR50,App K for Ccnpp Unit 1 ML20085D4901995-06-0909 June 1995 Application for Amends to Licenses DPR-53 & DPR-69, Implementing Changes to Radiological Effluent TS Per GL 89-01 ML20084R0111995-06-0606 June 1995 Application for Amends to Licenses DPR-53 & DPR-69.Amends Would Revise TSs to Extend Certain 18-month Frequency Surveillances to Refueling Interval ML20084P9681995-06-0202 June 1995 Application for Amends to Licenses DPR-53 & DPR-69,proposing TS Re Pressurizer Safety Valves Lift Tolerance ML20087H9141995-04-28028 April 1995 Application for Emergency Amend to License DPR-53.Amend Would Revise CREVS TSs to Provide an Extension of Allowed Outage Time ML20081D0411995-03-15015 March 1995 Application for Amends to Licenses DPR-53 & DPR-69 to Reformat Current Administrative Controls Section & Relocate Several Requirements to Other Documents & Programs ML20079A5771995-02-24024 February 1995 Application for Amend to License DPR-69,allowing Extension of Interval Between First & Second Type a Test During Second Service Period & Extension of Second Service Period to 12 Years to Coincide w/1999 Plant Inservice Insp ML20078G8161995-01-31031 January 1995 Application for Amends to Licenses DPR-53 & DPR-69,revising TS to Increase Min Amount of Trisodium Phosphate Dodecahydrate Verified in TS Surveillance ML20073G2401994-09-23023 September 1994 Application for Amends to Licenses DPR-53 & DPR-69,allowing one-time Extension from 7 to 14 Days of AOT for Dedicated Class 1E Emergency Power Source During 1995 Refueling Outage ML20071P4421994-08-0404 August 1994 Application for Amend to License DPR-53 & DPR-69,eliminating TS 3/4.3.3.3 for Seismic Monitoring Instrumentation, Relocating Requirements for Operation & Testing of Seismic Monitoring Instrumentation to Plant Updated FSAR ML20149E8321994-08-0202 August 1994 Application for Amends to Licenses DPR-53 & DPR-69,revising Surveillances Associated W/Edgs to Add High Crankcase Pressure to EDG Trips Which Are Verified to Be Automatically Bypassed on Safety Injection Actuation Signal ML20071N2961994-08-0202 August 1994 Application for Amends to Licenses DPR-53 & DPR-69, Incorporating TS 3.9.1, Refueling Operations,Boron Concentration ML20069H6471994-06-0808 June 1994 Application for Amends to Licenses DPR-53 & DPR-69,revising TS 4.6.2.2.d,extending Surveillance Interval from 18 to 24 Months ML20069H6191994-06-0808 June 1994 Application for Amends to Licenses DPR-53 & DPR-69,revising TS 4.8.1.1.1.b,extending Alternate Offsite Power Circuit Surveillance Frequency from 18 to 24 Months ML20069H6311994-06-0808 June 1994 Application for Amends to Licenses DPR-53 & DPR-69,revising TS 4.7.1.2.c,extending Interval for Three Auxiliary Feedwater Surveillance Requirements from 18 to 24 Months ML20069C3921994-05-27027 May 1994 Application for Amend to License DPR-69,revising Heatup & Cooldown Curves & LTOP Controls for Unit 2 to Support Mods to LTOP Sys Scheduled for Spring 1995 Refueling Outage ML20069C2801994-05-27027 May 1994 Application for Amends to Licenses DPR-53 & DPR-69, Revising TS Surveillance Test Interval from Monthly to Quarterly for Several Channel Functional Tests for RPS & ESFAS ML20058K2831993-12-0808 December 1993 Application for Amends to Licenses DPR-53 & DPR-69,revising TS Associated W/Content of Design Features ML20059L4051993-11-11011 November 1993 Application for Amends to Licenses DPR-53 & DPR-69,revising TSs by Relocating Tables of Response Time Limits for Reactor Protection Sys & ESFAS Instruments from TSs to Updated FSAR 1999-09-01
[Table view] |
Text
__ __ _ _ _ _
b , ,o 1 l
r3 ALTIMORE i CAS AND ELECTRIC CHARLES CENTER e P.O. DOX 1475
- BALTIMORE. MARYLAND 21203-1475 GroAGE C CRttL Vic t Pat siot h?
Noct s an tscsso, no o.c ..%
June 28,1991 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION: Document Control Desk
SUBJECT:
Calvert Cliffs Nuclear Power Plant Unit Nos.1 & 2; Docket Nos. 50-317 & 50-318 Additional Information, Technical Specification Change Request:
Plant Oprations and Safety Review Committee (POSRC),
(TAC bos. 77616 and 77617)
REFERENCE:
(a) Letter from Mr. G. C. Creel (BG&E) to Document Control Desk (NRC), dated August 23, 1990, Technical Specification Change Request: Plant Operations and Safety Review Committee (POSRC)
Gentlemen:
Reference'(a) requested an amendment to Baltimore Gas and Electric Company's (BG&E's)
Operating License Nos. DPR-53 and DPR-69 for Calvert Cliffs Unit Nos.1 & 2, respectively. The two major changes involved the deletion of specific titles for members of the Plant Operations and Safety Review Committee (POSRC) and the use of a Procedure Review Committee or Qualified Reviewers to perform selected procedure reviews in lieu of review by POSRC. Other changes were also included.
This letter supplements the referenced submittal and is provided to reflect a change in BG&E's approach to procedural control associated with a major project for procedures upgrade, and to reflect initial comments from the NRC staff.
Reference (a) numbered and described 23 changes in the DESCRIPTION OF CHANGES section.
Discussions follow addressing those that have been modified. The attached draft Technical Specification pages incorporate all proposed changes, with the modified areas identiGed. Only Unit 1 pages are provided. The Unit 2 pages contain identical information in the affected areas.
J Adg$
9107120247 910628 80j PDR :ADOCK 05000317 P PDR I
'a
.. i.-
Document Control Desk June 28,1991 Page 2 CIIANGE 3 Change 3 deleted speciGe titles for members of POSRC in Specification 6.5.1.2 and instead listed eight areas in which POSRC members will collectively have experience. The commitment to have at least one member who has a Senior Reactor Operator (SRO) license was also added. Of the eight areas in which the PO3RC members must now collectively have experience, only Nuclear Operations would be expected to be filled by someone with an SRO license. Ilowever, that area will normally be covered by the Su acrintendent - Nuclear Operations, who is not required to hold an SRO license. In order to address t iis and to allow for Ocxibility in the POSRC composition area, an approach similar to that used for the Offsite Safety Review Committee (proposed Specification 6.5.4.2) has been used.
The composition will consist of from seven to ten members. Specification 6.5.1.6, OUORUhi, will require a majority of members for a quorum. The voting alternates limitation in Specification 6.5.1.4 has been moved to proposed Specification 6.5.1.6, OUORUhi, and limits voting alternates, including an alternate chairman, to no more than half the quorum. These requirements are not significantly unlike those proposed by Reference (a). The eight areas the POSRC will have experience in are not changed. The qualifications for members and alternates are not changed.
Because the Plant General hianager will no longer be the Chairman of POSRC, the Plant General hianager has been added to proposed Specification 6.5.1.7.i. as an additional individual who shall be sent reports concerning investigations of violations of the Technical Specifications, and to proposed Specification 6.5.1.10, RECORDS, as an additional individual who shall be provided copics of POSRC meeting minutes.
CilANGE8 Change S included adding the words "which affect nuclear safety" to modify the phrase, in proposed Specification 6.5.1.7," Review of 1) all procedures required by Specification 6.8 which affect nucleg safety . . . ." This distinction is more appropriately made in Specification 6.8 itself. Therefore, the proposed words have been deleted in proposed Specification 6.5.1.7 and a new change made in Specification 6.8, excluding fire protection procedures which do not affect nuclear safety (and changes thereto), from required POSRC review.
CllANGE 9 Change 9 involved the renumbering of several associated specifications, mainly due to Change 10, which deleted present Specification 6.5.1.6.h. Ilowevet, present Specification 6.5.1.6.h (now proposed 6.5.1.7.m) will not be deleted, and a new item, proposed Specification 6.5.1.7.h, discussing POSRC review of 10 CFR 50.59 Safety Evaluations, will be added to the series of items under POSRC responsibilities. Some of the Specifications under Change 9 are therefore renumbered again, along with references to them.
CilANGE 15 Change 15 added new specifications for the Procedure Review Committee and the Qualified Reviewer Program.
Proposed new specifications under Specification 6.5.2 for the Procedure Review Committee are slightly changed. For consistency with proposed Specification 6.5.3.1, the phrase "or Qualified
Document Control Desk June 28,1991 Page 3 Reviewer" was added to proposed Specification 6.5.2.1 immediately following "in lieu of review by POSRC.* For consistency with proposed SpeciGeation 6.5.1.8.c, a sentence was added addressing the Plant General Manager's responsibility for resolution of disagreements between the Procedure Review Committee and the approval authority.
New specifications under proposed Specification 6.53 for the Qualified Reviewer Program have also changed. Discussions follow.
The title itself has been changed to " QUALIFIED REVIEWERS." The word " PROGRAM" was j deleted to provide consistency with other use of that term in site activities.
I; Proposed Specification 6.53.1, FUNCTION, has editorial changes.
Proposed Specification 6.53.2, RESPO_NSIBILITIES, addresses items that more appropriately belong under AUTliORITY. so the title was changed. Also, the approach reDected by Reference (a) envisioned a group of individuals who would perform a wide range of reviewer activities. A smaller group, performing a smaller range of activities, is now envisioned. Previously proposed Specification 6.53.2 provided for procedure review, cross disciplinary reviews, and ,
screenings to determine whether 10 CFR 50.59 safety evaluations should be performed. The new l proposed Specification 6.53.2, consistent with proposed Specificatior 6.5.2.7 for the Procedure j Resiew Committee, provides only for procedure review and determinations with regard to whether l or not each procedure resiewed constitutes an unreviewed safety question. Cross disciplinary reviews and 10 CFR 50.59 screenings will be performed by reviewers other than those addressed in the Technical Specifications. 'Itc requirement for cross. disciplinary reviews is maintained, however, placed in proposed Specification 6.5.1.7.a.
Proposed Specification 6.53.2.c was added to address disagreements between Qualified Reviewers and approval authorities. The approach is the same as that for POSRC and for the Procedure Review Cominittee.
' Proposed Specification 6.533, AUTIIORITY. has changed and is more appropriately titled CERTIFICATION. Previously, this section addressed (a) the c'esignation of Qualified Reviewers, and (b) written recommendation to the approval authority of approval or disapproval of procedures.
Item (b) is now addressed in proposed Specification 6.53.2. Itet (a) remains, is changed, and needs
- discussion. Previously, the Qualified Reviewers were to be oignated by the responsible approval authority, After further considerations, we believe the proper place for Qualified Reviewer designation (we now use " certification") is at the department manager position. This level is high enough that the importance of the certification is addressed, yet not so high or so far removed from the procedure subject area that the certification loses meaning.
Proposed Specification 6.53.4, RECORDS, has been renumbered 6.53.5 and has only editorial changes.
. Proposed Specification 6.53.5, TRAINING AND OUALIFICATION. has been renumbered 6.53.4 and moved to CERTIFICATION along with proposed Specifications 6.533. The specific qualifications for Qualified Reviewers have been delineated.
Doct. ment Control Desk
, June 28,1991 l Page 4 CllANGE 16 Change 16 created a new Specification 6.8.2 that allowed the Plant General Manager to designate procedures to be reviewed by the Procedure Review Committee or a Qualified Reviewer. Minor editorial changes have been made, and an explicit requirement that these designations be made in writing has been added.
CII ANGE 17 Change 17 addressed the splitting of present Specification 6.8.2. into new Specifications 6.83 and 6.8.4, which address approval authority and periodic review, respectively. Per Reference (a),
approval authority was to be designated by the Plant General Manager and could be a Manager, a Superintendent, or a General Supervisor. Editorial changes have been made, and an explic;t requirement that these designations be made in writing has been added. Also, approval authority has been changed to a hianager, a Superintendent, or a General Supervisor (or Director) that reports directly to a Manager.
An editorial change was made in Specification 6.8A. The phrase "and administrative policy" was deleted. The referenced specification,6.8.1, addresses procedures which control administrative and technical activities. It does not address administrative policies. The term " administrative policies" has a specific meaning in BG&E's new approach to procedures. To avoid confusion and to be moic accurate, the phrase was deleted.
CIIANGE 18 Change 18, addressing temporary procedure changes in proposed SpeciGcation 6.8.5, has minor editorial changes.
NOTE ON C11ANGE 20 Change 20 discussed deletion of the word " written" in proposed Specification 6.5.1.8.b, but was not reDected in the marked-up pages attached to Reference (a). That change is still desired and is reuccted in the changed pages attached herein.
SUMMAltY The items discussed in this letter are for the most part minor refinements to the approach to implementation of the key objectives of the originally requested amendment Reference (a). Those objectives were to no longer require specific superv;sory positions as POSRC members and to establish a Procedure Review Committee and Qualified Reviewers. The arguments in the Determination of No SigniScant Hazards in Reference (a) are still valid with these refinements. All of the proposed changes are designed to strengthen POSRC and make it operate more effectively.
POSRC will continue to represent the same areas of expertise and to meet the experience and training provisions of ANSI N18.1-1971. More emphasis can be placed on other matters of safety significance by the establishment of the Procedure Review Committee and Qualified Reviewers to review selected procedures as determined by the Plant General Manager. Both programs still describe what is to be reviewed and how this determination is made, will provide for inter-disciplinary I
I
j Docurnent Control Desk June 2F,1991 Page 5 review of subject matter, document the review, and forward the ;ccommendation to the appropriate member of management.
We appreciate your consideration of these changes. We feel that they are necessary to reflect the new approach to procedure control and that these Technical Specifications and those new controls will very positively affect the overall level of quality and excellence achieved at Calvert Cliffs.
C Should you have any questions regarding this matter, we will be pleased to discuss them with you.
Very truly yours (4
STATE OF MARYLAND : j
- TO WIT :
COUNTY OF CALVERT :
I hereby certify that on the O@ day of 1 ne. ,19 (blv$,cetbefore me, }he subscriber, a Notary Public of the Sfate of hlaryland in and for Counft1 ,
personally appeared George C. Creel, being duly sworn, and states that he is Vice Prakident of the Baltimore Gas and Electric Company, a corporation of the State of hlaryland; that he prevides the foregoing response for the purposes thercia set forth; that the statements made are true and correct to the best of his knowledge, information, and belief; and that he was authorized to provide the response on behalf of said Corporation.
WITNESS my Hand and Notarial Scal: NR Notary Public hty Commission Expires: / a4</ h /
1/6te
/
GCC/DLS/bjd/ dim Attachments cc: D. A. Brune, Esquire J. E. Silberg, Esquire R. A. Capra, NRC D. G. hicDonald, Jr., NRC T. T. hiartin, NRC L E. Nicholson, NRC R. I. hicLean, DNR J. H. Walter, PSC