RELATED C07.PIS?0"DE:10E

,}

DOCKETED "C

HuxTox & WILLIns 7o7 EAST MAIN sTRCCT P. o. Box 1535 U

~7,c.P.,(39,,,,,,_.,

o o & T uitoiwo Ricnwoxn, VmorxzA 20212 R e.Com eo.

p. o..oa s.aao attire., no t c..oLim. a?.oa
      • "'"*'0 CFTi'.E Of=w,03t.."w.o. c. aoos.

TELC PHON C

')04-788-8200 e a.c.. 37 t

00CnEiiNG & SERV;I:I rimerv,...~,.....vo.c.

B%UGU 24566.3 o co....,

~o=,o a..............

November 4, 1983

.e.....

o,.cc,o,.L....o. 7.. 8 3 6 1 BY HAND Lawrence Brenner, Esq.

Administrative Judge Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Long Island Lighting Company Docket No. 50-322 (OL)

Dear Judge Brenner:

Enclosed are the following:

1.

FAA's report on the cause of the failure of the crankshaft on diesel generator 102; 2.

FAA's analysis of the replacement (13 X 12") crankshafts for the Shoreham diesel generators; and 3.

FAA's preliminary report on the diesel generator connecting rod bearings.

Because only a limited number of copies of this report are available right now, only one copy is being provided.

Please let me know if the Board would like additional copies and I will forward them as soon as they are available.

Sincerely, bl g/

Anthony F. Earley, Jr.

// 7 7

221/403 Enclosures cc:

Dr. Peter A. Morris Dr. George A.

Ferguson All Parties 8311090228 831104 h

PDR ADOCK 05000322 C

PDR

. - ~

.-.