SD-T V 4
New York State Department of Environmental Conservation
~
50 Wolf Road, Albany, New York 12233 w
Langdon Marsh Commissioner February 2, 1995 Mr. Dominick Orlando US Nuclear Regulatory Commission 1 White Flint North 11555 Rockville Pike Rockville, MD 20852
Dear Mr. Orlando:
Re:
Cintichem, Inc. Decommissioning Proposed Bedrock Criteria We received a copy of Mr. McGovern's January 6, 1995 letter to the NRC regarding Cintichem's proposed decontamination criteria for bedrock.
Mr. McGovern's letter transmitted a document entitled, " Analysis Summary of Hypothetically Projected Dose Due to Bedrock Contamination."
We have reviewed both the letter and the Analysis Summary and offer the following comments for your consideration:
1.
In the transmittal letter, Mr. McGovern writes, l
This pro-forma calculation is presented to demonstrate l
the proposed methodology that will be used for determining the acceptance criteria for any bedrock as Final criteria will be different and necessary.
will deoend on the actual characteristics of the bedrock that are found at the time of the final survev.
(underlining added)
This implies that the proposed calculations wil.1 be done after the bedrock decontamination is completed.
- However, Section 5.6 of the Analysis Summary appears to contradict that statement:
The surface contamination limits that were derived along with the bedrock concentration limits will be used for go-nogo screening during remaining D&D work before final rock sampling is performed.
Cintichem should clearly explain when the actual limits will be derived and applied.
ig,
.-m 9502150313 9502O2
\\
\\
Q:
PDR ADOCK 05000054 i
P PDR I
1
'Mr. Orlando Page 2 February'2, 1995 2.
In Section 5.6, Cintichem propases to use the derived surface limits for screening bedrock.
It is very doubtful that - rface radiation readings would correlate with either the total activity or the concentration of radionuclides in cracks that extend more than a foot into bedrock, particularly when the orientation of the cracks appears to be unpredictable.
Unless the surfaces of the cracks are exposed, a surface survey will not provide any reliable information about material buried in the rock. The only relevant measure is the concentration of radioactive material in the rock.
Cintichem should characterize the contamination that currently remains in the bedrock.
If the concentrations and total activity are sufficiently low that plausible uses of this material would not result in a significant dose, it should be left where it is.
In order to answer this question, cores should be taken from the areas of highest suspected contamination.
To determine the concentration profile, the cores should be broken into one-foot segments for analysis.
(It may not be necessary to analyze each segment.
For example, every third core could be analyzed initially, and others analyzed as needed to complete the profile.)
3.
The Analysis Summary contains references to preliminary core data.
Cintichem should include that data in the Summary or provide it separately to DEC.
4.
The industrial intruder scenario is assumed to last only six months, and it ends with loading the bedrock for sale.
Cintichem should evaluate the potential doses due to reasonable uses of the crushed rock after it is sold.
For example, if the rock were used for a driveway, tne time of exposure would be longer than six months.
The doses may not be significant, but this should be confirmed.
If you have any questions, please call Barbara Youngberg or John Kadlecek of this Bureau (518-457-2225).
Sincerely yours, Paul J. Merges, Ph.D.
Chief, Bureau of Radiation Division of Hazardous Substances Regulation cc: