Forwards Response to Violations Noted in Insp Rept 50-289/94-80.Corrective Actions:Maint Dept Issued Plant Maint Standing Order 32,rev 0 to Ensure Requirements of Step 4.2.3.D Met
ML20078L308
Person / Time
Site: Crane 
Issue date: 11/18/1994
From: Broughton T
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
C311-94-2312, NUDOCS 9411290150
Download: ML20078L308 (3)


Text

_

\\

b GPU Nuclear Corporation 1 ti Nuclear

" r = ! r '"

Middletown, Pennsylvania 17057-0480 (717) 944-7621 Writer's Direct Dial Number:

(717) 948-8005 November 18, 1994 C311-94-231?

U.S. Nuclear Regulatory Commission Attn: Decitment Control Desk Washington, DC 20555

Subject:

Three Mile Island Nuclear Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Inspection Report 94 Response to Notice of Violation

Dear Sirs:

Enclosed is the GPU Nuclear response to the Notice of Violation transmitted as an enclosure to Inspection Report 94-80.

Please contact J. S. Schork, TMI Licensing, at (717) 948-8832 if you have any questions regarding this response.

Sincerely, bb l%

T. G. B ton Vice President and Director, TMI JSS/ emf cc:

M. G. Evans - TM1 Senior Resident Inspector R. W. Hernan - Senior Project Manager T. T. Martin - NRC Regional Administrator, Region I 280004 9411290150 941118 PDR ADOCK 05000289 l

hl D

PDR GPU Nuclear Corporation is a subsidiary of General Pubhc Utikties Corporation

,v l,

c, C311-96-2312 NOTICE OF VIOLATION 94-80-01 During an NRC inspection conducted on August 29 to September 16, 1994, a violation of NRC requirements was identified.

In accordance with the " General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2,_

Aopendix C, the violation is as listed below:

Technical Specification (TS) step 6.8.1 states, in part, that written procedures shall be established and maintained covering the applicable procedures recommended in Appendix A of Regulatory Guide 1.33, Revision 2, February 1987.

Appendix A, Procedures for Performing Maintenance, Regulatory Guide 1.33, Revision 2, February 1978, states, in part, that preventive maintenance schedules should be developed to specify lubrication schedules, and inspection of equipment.

Administrative Procedure (AP) 1070, TMI-l Maintenance Plan, Revision 8, written to comply with TS 6.8.1, established the preventive maintenance (PM) program and schedule as follows:

Step 3.1.2.1 defines PM tasks as actions taken on a routine basis to restore part or all of the failure resistance of unfailed equipment or systems, initiated as a function of time or production, regardless of the actual condition of the equipment or system.

Step 4.1.3.2 states that FM tasks shall be initiated as part of the automated generation maintenance system.

Step 4.2.3.0 states that the task perforinance interval may be adjusted as a result of assess hg the adequacy of the PM program and also as a result of reliable pr.rformance of equipment / component or satisfactory performance of FM.

Contrary to the above, on August 30, 1994, TMI-l personnel had deferred / cancelled several PMs on safety-related motor-operated valves without prior technical justification or assessment of the adequacy of the PM program.

This is a Severity Level IV violation (Supplement 1).

.~

e

'C311-94-2312 GPU NUCLEAR RESPONSE TO NOTICE OF VIOLATION 94-80-01 GPU Nuclear agrees the violation occurred as stated in the Notice of Violation.

1.

Reason for the Violation The deferral / cancellation of preventive maintenance (PM) tasks on safety-related motor-operated valves without a documented technical justification or assessment of the adequacy of the PM program occurred because Step 4.2.3.D of Ap 1070 was misinterpreted.

The phrase " task performance interval may be adjusted" in Step 4.2.3.D was interpreted to mean that only permanent alterations to task intervals required a formal, documented assessment and that AP 1070 did not require a detailed, documented assessment for the deferral / cancellation of single PM activities.

Plant personnel did evaluate the consequences of individual PM deferral / cancellations to ensure there was adequate technical justification and in some cases consulted with Plant Engineering, but did not document these evaluations.

2.

Corrective Steps That Have Been Taken and The Results Achieved On September 9,1994, prior to the end of the OSTI inspection, the TMI Maintenance Department issued Plant Maintenance Standing Order No. 32, Revision 0, to ensure the requirements of Step 4.2.3.D are met.

Standing Order No. 32 directs maintenance personnel to perform and document evaluations of deferrals of PM activities with the exception of those related to data gathering, performance monitoring, and equipment housekeeping requirements (i.e., weather station checks, ICS checks, equipment vibration monitoring).

These evaluation requirements vary in level of detail ba:ed on the particular activity and on the impact of the component on the plant. Activities established for purposes of data j

gathering, housekeeping requirements, etc., receive a different type of evaluation than other, component specific, PM activities. Also, evaluations performed for more critical components are required to be more in-depth than those for less critical components.

3.

Corrective Steps That Will Be Taken To Avoid Further Violations A revision to Standing Order No. 32 is currently being prepared.

This revision requires elevated management review and approval of long interval extensions, and requires Engineering review of interval i

extension evaluations on the deferral / cancellation of PM tasks associated with regulatory requirements.

This revision is expected to be issued before January 1, 1995.

1 It is GPU Nuclear's intent to continue to utilize this Standing Order until the program is developed to the point that it is fully effective.

At that time the Standing Order requirements will be incorporated into the Maintenance administrative procedures.

This is anticipated to occur no later than the end of the first quarter 1995.

4.

Date Of Full Compliance Full compliance with TS 6.8.1 and AP 1070 requirements was achieved with the issuance of Standing Order No. 32. All followup actions will be completed by the end of the first quarter 1995.