{{#Wiki_filter:.__ l AUGMENTED INSERVICE INSPECTION PLAN WN COMAMCHC PEAK STEAM EutCTRIC STATION UNIT 2 Revisiest O l l l Mt-M6/FV erepared: Approved: / -> b 2-/4-94 / 9501240376 950117 ) DR ADOCK 05000446 PDR

AUGMENTED INSERVICE INSPECTION PLAN 'Ihe purpose of this document is to identify and describe various regulatory and CPSES commitments involving the performance of periodic non-destructive ernminauons (NDE) other than those addressed in ASME Section XI (i.e., augmented inservice inspecuon). A separate section is provided for each major activity. Within each section the following information is provided: a Governing Document h Exam Items & Boundaries c. NDE Method and Schedule d. Acceptance Criteria e. Special Reports NOTE: Where Sections of the ASME Code are used in this document, the Edition and Addenda shall be as referenced in the CPSES Unit 2 Inservice Inspection Plan. R l 1 (1)

TABIZ OF CONTEXTFS I SECI1ON PAGES 1 REACTOR COOIANT PUMP FLYWHEELS 2 2 SAFETY INJECT 10N PUMP SHROUD 2 3 FLUX THIMBLE TUBES 2 4 MAIN S1EAM AND FEEDWA*IER BREAK EXCLUSION PIPING 1 EXAMINATION TABLES 30 5 SUPPLEMENTARY CONTAINMENT SPRAY AND RESIDUAL HEAT REMOVAL PIPING WELDS 1 EXAMINATION TABLES 6 6 REACTOR VESSEL HEAD AND INIERNALS LIFTING DEVICES 8 A

SUMMARY

OF REVISIONS 1 B INIERIM CHANGE REQUEST QCR) INDEX 1 (11)

REACTOR COOLANT PUMP FLYWW NTA l Each reactor coolant pump flywheel shall be subject to the examinations described in Section C.4.b. of Regulatory Guide 1.14 Revision 1. August 1975 (Ref. FbAR 5.4.1.5.2 and Tech. Spec. 4.4.9). These examinations shall consia.1 of an in-place ultrasonic ~=mination of the areas of higher stress concentration at the bore and keyway at approximately 3-year periods. Additionally, the exposed surfaces of each Dywheel shall be subject to a 11guld penetrant examination along with a cornplete ultrasonic examination at approximately 10-year intervals. Wamination procedures and personnel shall be in accordance with IWA-2200 of Secuon XI to the extent practical. The schedule for==minations shall be coincident with the inservice inspection periods and intervals described in ASME Section XI. The acceptance limit for flaw size based upon the maximum design overspeed is 1.15 trL (Ref. WCAP-8163). All flaws detected shall be recorded for evaluation and monitored for growth rate. No special reports are required for this activity unless examination and evaluation indicate that the 1.15 in. flaw size Itmit has been or will be exceeded during the service life of the flywheel. Should this occur, the NRC shall be notifled (Ref. Reg. Guide 1.14 c.4.b.(5)). Records of the examinations shall be maintained with the applicable work order. Summary Discussion Governing Document - Regulatory L*de 1.14 Rev.1. a. b. Exam items and Boundaries - Each reactor coolant pump Dywheel. NDE Method and Schedule - An in-place ultrasonic examination of the bore and keyway at c. 3-year intervals and a liquid penetrant examination of exposed surfaces and a complete ultrasonic namination at 10-year intervals. d. Acceptance Criteria - No flaws greater than 1.15 in. Special Reports - The NRC shall be notified should the maximum Daw size be exceeded, or l c. expect to be exceeded, during the service life. l i (1) l

a j;i* !I j l r ,'l j1 X X X X X X X X 3 2 X X X X 4 l X X X X 1 X X X X X X X X 3 3 2 X X X X 1 X X X X 3 X X X X X X X X 2 2 X X X X 1 X X X X X X X X X X X X 3 X X X X 1 2 1 X X X X N O IT ) ) C R H E A T S E N Y O L E 0 M 1 NE ( 0 ) AH L ( 9 2 t LW A P Y V D L R O IS I F E R I T E A P N P M I U P .C R E E E E D T D T E D T E D T E M R Y E S EE R Y E S EE R Y E S E E R Y E S EE E A S E L A S E L A S E L A S E L P A M U BW O C P M P A M U BW O C P M P A M U BW O C P M O X BW O C P M O O A O P A M U L F L Y F L Y L Y F Y F X O O E R E X O O F E X O O F F E F E X O O O K U C V O K U CV O K U C V E R E R E R O K U C V E T T S T T T S T T T S T T T S T U P U U P U U P U U P U 2 3 4 1 0 0 0 0 -C C C C P P P P C C C C s P P P P G C C C C A R R R R T X X X -XC C C C T T T T 1 j 1

= _. ~ i 3 I SAFETY INJECTION PUMP SHROUD 4 i visible linear indications have been found on the shroud that separates and supports the diffuser i vanes and return guide vanes on the type pump utilized as the safety injection pump at Camaneh* i 1 Peak Steam Electric Station (CPSEG). These indications exceed the da=tgner-permitted 1/16 in. j maximum. De pump supplier (Pacific Pumps) has evaluated the significance of these indications and determined they have no adverse affects upon the operability of the pumps (Ref. NUREG-0797 I i Supplement 12). Pacific Pumps has proposed a field inWlan program which addresses this issue. This program j has been supplemented by the NRC and is described in NUREG-0797 Supalaman* 12. j he program requires a visual and surface ernmination of the shmud section of the intermediate i cover during normal or emergency maintenance at apprnrtmately 10-year intervals (pump disassembly solely for this ernmination is not required). A lov of all indications is to be j maintained. with indications having a depth greater than 1.0 Jn. in the radial direction to be j reported to Pacific Pums. Records of the examination shall be maintained in the applicable work order. Ij. Summary Discussion Goveming Document - Supplemental Safety Evaluation Report 12 (NUREG-0797). a. b, Eram items and Boundaries - Shmud section of the safety injection pumps' intermediate r cover. 1 NDE Method and Schedule - Visual and surface ernmination during normal or em rgency c. j maintenance at approximately 10 year intervals. j d. Acceptance Criteria - All indications shall be recorded with evaluation being on a case-by-l case basis t Special Reports - All indications *=e** ding 1.0 in. in the radial direction shall be reported l e. to Pacific Pumps. 3 0 1 J f 3 i (1) l 1

ae._m 7 8-9 5 m 8m h i. 5 a E l e W O e aa W I e E E a k. I fu e a m-s Ie a = 4 a s a a g

ICR AISI-2RO-02 Page 2 of 4 O FLUX THrMmE TUBES Westinghouse reactors containing bottom mounted instrumentation (BMI) flux thimble tubes have experienced wear due to flow induced vibration in the reactor vessel. These thimble tubes provide a pathway for the neutron flux detectors and extend from the seal table into the fuel assembly area. 'Ihese tubes are closed within the vessel but open at the seal table. Therefore, these tubes constitute l a portion of the reactor coolant system pressure boundary. In response to this issue, the NRC issued Information Notice 87-44 (9/87), with Supplement (3/88), and Bulletin 88-09 (7/88). Bulletin 88-09 requested an inspection program be implemented to monitor thimble tube performance, with the program to include acceptance criterion, !nspection methodology and frequency. Ixtter TXX 89781 provides a response to this bulletin and describes the intention of'IU Electric to comply with the bulletins' requirements. The augmented inservice inspection shall include a full length examination, within the limitations of probe travel, of all 58 thimble tubes using standard eddy current testing (ET techniques. St.pplementary techniques or methods may be used for further evaluation. 'Ihese examinations shall be conducted during the first refueling outage with subsequent examinations j determined by the results obtained during previous examinations. Acceptance criteria for this activity is as follows: Wa < 8@6: No action required Wa280%: Cap or reposition , Q Use the following equation to calculate predicted wear: Wa = Wd (Na/Nd)n Where: Na= Accumulated time at which wear depth is to be calculated Nd = Operating time accumulated before inspection Wa= Percent Wear Depth at time Na Wd= Percent Wear Depth at the time of the inspection 0.67 i n = In accordance with TXX-89781 a special report shall be issued to the NRC within thirty days of 'fcR Il 4 completion of thimble tube examinations conducted during the first outage. This report shall describe the tubes examined and the restilts, as a minimum. J Summary Discussion: a. Governing Document - NRC Bulletin 88-09. CPSES-9006199. b. Exam items and Boundaries - All 58 thimble tubes to the extent possible of the full length, i c. NDE Method and Schedule - ET to be performed on a schedule based upon previous examinations. d. Acceptance Criteria - See above discussion based on WCAP 12866. l 'CCC 1 Special Reports - A special report will be issued to the NRC within 30 dcys of completion of e. {} the thimble tube inspection conducted during the first outage, j v (1)

~ _ l l l l ICR MSI-2RO-02 Page 3 d4 TURE ID OITTAGE R$h COMMENTS A-9 RF01 '0 'A-11 RF01 O B-3 RF01 0 i B-6 RF01 0 r B-8 'RF01 O l B-13 RF01 O C-5 RF01 0 C-7 RF01 0 C-8 RF01 O D-3 RF01 0 D-8 RF01 0 D-10 .RF01 0 D-12 RF01 0 D-14 RF01 O E-5 RF01 .O E-9 RF01 24 E-11 RF01 O F-1 RF01 O F-3 RF01 O F-7 RF01 O F-8 RF01 O F-14 RF01 0 G-5 RF01 0 G-9 RF01 0 G-12 RF01 O H-2 RF01 O O H-3 RF01 O H-4 RF01 O H-6 RF01 O H-11 RF01 35 H-13 RF01 0 H-15 RF01 58 J-1 RF01 O J-7 RF01 O J-8 RF01 O J-10 RF01 0 J-14 RF01 0 K-2 RF01 21 K-6 RF01 0 K-12 RF01 0 L-5 RF01 0 L-8 RF01 O J L-10 RF01 O L-11 RF01 O L-13 RF01 O L-15 RF01 0 M-7 RF01 0 N-2 RF01 O N-4 RF01 O N-6 RF01 0 N8 RF01 O N-13 RF01 0 N-14 RF01 0 P-4 RF01 0 P-9 RF01 22 R-6 RF01 0 R-8 RF01 0 R 11 RF01 O (2) TcR a i

i MAIN STEAM AND FEEDWATER BREAK 1 EXCLUSION FIFING Main Steam and Feedwater piping located in the safeguards building which has been designated as " break exclusion piping" in FSAR Section 3.6.B. is to be ernmined in accordance with Auxiliary Systems Branch 3-1 (Ref. FSAR 6.6.8). This shall consist of an ultrasonic ernmination, to the extent practical, of all circumferential and longitudinal piping welds, except as may be exempted by ASME Section XI. ASME Section XI allows exemption from ernmination for piping 4" and less. The augmented inservice inspection shall include all welds and poruons thereof which meet the above criteria but which are not selected for ernmination as dehneated in the ASME Section XI Inservice Inspection Plan. These ernminations shall be distributed such that each weld or portion thereof is ernmined once during each 10-year inservice inspection interval. I Examination procedures and personnel shall be in accordance with the rules of ASME Section XI. No special reports are required for this activity. Records of the ernmanations shall be maintained wit'i the applicable work order. Itsults of these examinations shall be evaluated against the acceptance criteria provided in ASME 'ection XI. IWC-3000. Summary Discumminn a. Governing Document - Aurillary Systems Branch 3-1. FSAR 6.6.8. b. Exam Items and Boundaries - All non-exempt circumferentini and longitudinal welds in the Main Steam and Feedwater systems contained within the break exclusion zones, which j are not scheduled to be examined as part of the Secuon XI inservice _Wian program. c. NDE Method and Schedule - Ultrasonic eramination once per 10-year interval. 'Ihe specific schedule by refueling outage is attached. d. Acceptance Criteria - ASME Section XI. IWC-3000. ) e. Special Reports - None l l i (1)

DATE: 02/16/94 NIGN ENERGY LINE ONEAK UNIT 2 PAGE: 1 AU M NTED INSERVICE INSPtCT10N PLAN CLASS 2 SCNEDULED COMPONENTS INSPECTVJI INTERVAL _ PLAN STATUS _PRESERVICE YEAR l FIRST SECOW TNIRD l ASIE l PERIOD PERIS PERIOD l SEC. XI l -- -----* * --- - --- -- - - -- l sumARY EXM INATION AREA CATGY WE l*-----0UTAGE--- --l INSTRUCTIONS j NUMBER IDENTIFICATION ITEM No METN l1 2 1 2 1 2 l " CALIBRATION BLOCE" ,j 1 MAIN STEM 32-MS 2-001 1303-2 1 1 f TDLR VERIFICATION BOUNDARY. 099200 TCX 2 2100 16 CF2 UT 1X PIPE TO PIPE C5.51 j 8 71S8 i

    • tex 33**

i 1 1005 FROM WLD 16 TO 21. TDLR ] 099250 TCX 2 2100-1eL CF2 UT 1X j LONG. SEAM C5.52 VERIFICATION BOUWARY. 1 871R5

    • TBX 33" i

i MAIN STEAM MS-25 (DalP POT) I' TDLR VERIFICATION BOUNDARY. N00 TCX 2 2100 18 C F-2 UT 1X PIPE To FRANCH ComECTION C5.51 i 874 2 1

    • TBX 22" l

i i MAIN STEAM 32-MS-2-001 1303 2 i TDLR.WRIFICATION SOUNDARY. 099700 TCX 2 2100-21 CF2 UT 1X PIPE To PIPE r$.51 i 8nts i tex.33 1 1 2 j 099750 TCX 2 2100 21L CF2 UT 1X 1001 FROM W LD 21 70 25. TDLR 4 LONG. SEAM C5.52 WRIFICATION BOUNDARY. l 8WM 4

    • TBM 33**

1 i 100100 TCX 2 2100 25 C-F 2 UT 1X TDLR WRIFICATION BOUNDARY. PIPE TO PIPE C5.51 j 87758 i TBM 33** a 1 .A s

i l i I* $W ATU = ~2 f C.C % h 3th$ PAGE: 2 NIGN ENERGY LINE BREAK UNIT 2 [ DATE: 02/16/94 \\ AUGMENTED INSERVICE INSPECT!0N PLAN CLASS 2 SCHEDULED CO WONENTS INSPCf, TION INTERVAL, PLAN STATUS ,PRESERVICE YEAR l l FIRST SEcolm TNIRD l ASME l PERIOD PEtttS PERl(2 l l - - -- - - -- -- -- -- --- ll SEC. XI INSTRUCTIONS l -0UTAGE SWMARY EXAMINATION AREA CATGY NDE IRMBER IDENTIFICATION ITEM NO METN l1 2 1 2 1 2 l

    • CALIBRATION BLOCK **

j i MAIN STEAM 32-NS-2-001 1303-2 l 1 1005 F30M WELD 25 TO 26. TOLR 100150 TCX 2 2100-25L C F-2 UT 1X VERIFICAT10N touleARY. LONG. SEAM C5.52 87758

    • TBX 33**

TDLR VERIFICATION BOUNDARY. 100200 TCX 2 2100-26 C-F 2 UT 1X j PIPE TO VALVE C5.51 I 877S8 l l

    • T8X 33**

1 l MAIN STEAM NS 25 (DRIP POT) v TOLR VERI'ICAT10N SOUNDARY. 100500 TCX 2-2100 29 C F-2 UT 1X I I PIPE TO CAP - C5.51 i 874SS

    • T8X 22**

MAIN STEAM 8-MS 2-257-1303 2 I TDLR VERIFICRricN sosseART. 100600 TCX 2 2100 30 CF2 UT 1X BRANCN CONNECTION TO PIPE C5.51 i 87858

    • tex 1P*

TDLR VERIFICATION BOUNDART. 100700 TCX 2-2100-31 C72 UT 1X P!PE TO VALVE C5.51 881SB

    • TsX 1P*

I ^ y re r. 882SB

    • C - W s

l

..~ j 1 l DATE: 02/16/96 NIGN ENERGY LINE BREAK UNIT 2 PAGE: 3 AUGNENTED INSERVICE INSPECTION PLAN i CLASS 2 SCNEDULED CODFONENTS 4 t INSPECTION INTERVAL, PLAN STATUS ,PRESERVICE YEAR l FIRST SECOS TNIRD l 1 AspE l PERIG) PERIS PERIS l 1 1 i SEC. XI l --------- - - -*- --- - --- --- - l i SUIBIARY EXAMINATION AREA CATGY NDE l--- --0UTAGE------l INSTRUCTIONS NUMBER IDENTIFICATION ITEM NO METH l1 2 1 2 12 l "CALigAATION BLOCK" 1 ] l j MAIN STEAN 8-MS-2-257 1303 2 1 1 TDLR VERIFICATION 00USARY. ) 100900 TCX 2 2100-33 CF2 UT 1X j P!PE TO ELBOU C5.51 4 88558 3 "TBK 17" 1 } 101000 TCM 2 2100-34 C-F 2 UT 1M TDLR VERIFICATI0tl 90US ARY. ) ELBOW 70 PIPE C5.51 se50s "TSM 17" TDLR VERIFICAfical 30Um ARY. } 101100 TCX 2 2100-35 CF2 UT 1X j PIPE TO VALVE CS.51 i 88558 "TBK-17" i s -t MAIN STEAN 6-2003-2 TDLR VERIFICATICII BOUSARY. 101200 TCX 2 2100 36 CF2 UT 1X 4 j BRANCN CONNECTION TO FLANGE C5.51 1 87sss ai "Tsu-36" u i TDLR VERIFICATION BOUNDARY. 101300 TCX 2 2100 37 CF2 UT 1X BRANCH CONNECTION To FLAlleE C5.51 5 87858 4 ygg.36** 1 TDLR VERIFICATICII BOUSARY. 101400 TCM 2 2100 38 CF2 UT 1X BRANCH COIINECTION TO FLANGE C5.51 87388 " TEM 36" i i TDLR VERIFICATION 00M WARY. 101500 TCX 2 2100 39 CF2 UT 1M BRANCN COINIECT10ll 70 FLANGE C5.51 87888 i "Tsu 36" i J -n-.

.c. 2 T4 t AMI-2de. e T A h 3,@ .DATE: 02/16/94 NIGN ENERGY LINE BREAK UNIT 2 PAGE: ,4 { T] jQ AusnENTED INsERv!CE INSPECTION PLAN CLAS$ 2 SCNEDULED CCNIPC#ENTS INSPECTION INTERVAL, PLAN STATUS .PRESERVICE YEAR l FIRST SEccle THIRD l AsME l PERIOD PERIOD PERIOD l sEC. xx l-------------------l i' su MARY ExANINAT10N AREA CATGy NDE l.-.-.. OUTAGE-***-*l ' INSTRUCTIONS NuNsER IDENTIFICATION ITEN NO METN l1 2 1 2 1 2 l "..CAtletATION BLOCK" 5 j NAlt STEAM 6-2003-2 TDLR VERIFICAfl001 OculeARY. i 101600 TCX 2 2100 40-CF2 UT 1x. BRANCN ColNIECTION TO FLANGE C5.51 87888

    • T5X 36**

1 4 1 2 FEEDWATER 18-FU-2-019-1303 2 TOLR VERIFICAT!0ei BOUNDARY. 102800 TCX 2-2101-12 CF2 UT 1x P!PE TO PIPE C5.51 i 85658 j

    • TBx 21**

j _~ i ) -= ~e C -: = = r = m - : r := - - --

=

1 j 85688 g l d. FEEDWATER 18 FW-2-036 2003 2 1 q _ e.n_s na ,a._. ..._.m. l ac mi _ un y,a j 856ss 6* _r m 103200 TCX-2 2101 16 CF2 UT 1x- ] J PIPE TO VALVE C5.51 i 85658

    • TBx 38**

j 103300 TCX-2 2101 17 CF2 UT 1x VALVE TO PIPE C5.51 85658

    • TBx 38**

~

t i

4 1 1 1 -+ w,

l l DATE: 02/16/94 NIGN ENERGY LINE BREAK UNIT 2 PAGE: 5 AulBIENTED INSERVICE INSP CTION PLAN CLASS 2 SCHEDULED COMPONENTS i l l INSPECTION INTERVAL, PLAN STATUS .PRESERVICE YEAR l FIRST SECCIS TNIRD l AstE l PERl(B PERICD PERIOD l SEC. XI l ---*---- - -*----- -- - -- --*- l $Ule4ARY EXAMINATION AREA CATGY NDE l---- -0UTAGE-----*l INSTRUCTIONS NUMBER IDENTIFICATION ITEM NO METN l1 2 1 2 1 2 l "CAtleRAf tau BLOCX" FEEDWATER 18-FW-2-036 2003-2 103400 TCX 2 2101 18 CF2 UT 1X PIPE TO MapENT RESTRAINT C5.51 85655 "TBX 30"

  • l FEEDWATER 6-FW-2-095 1303 2 TDLR VERIFICATION SOUNDARY.

108500 TCX 2-2103-10 C-F 2 UT 1X l PIPE 70 PIPE C5.51 l WM

    • T8X 35**

l l TDLR VERIFICATION BOUNDARY. l 108600 TCX 2-2103 11 C.F.2 UT 1X ELBOW TO PIPE C5.51 86458 \\ "TBM 35" ) l TDLR VERIFICATION BOUNDARY. 108700 TCX 2 2103 12 CF2 UT 1X PIPE TO ELBOW C5.51 86438 eeygg. ;w 108800 TCX 2 2103 13 CF2 UT 1X TDLR VERIFICATION 80UISARY. ELBOW TO P!PE C5.51 864SS j

    • T8X 35" TDLR VERIFICATION ROUNDARY.

100900 TCX 2 2103 14 CF2 UT 1X PIPE 70 ELBOW C5.51 86558 j " tex 35** 109000 TCX 2 2103-15 C-F-2 UT 1X TDLR VERIFICATION BOUNDARY. EL90W 70 PIPE C5.51 86888

    • TBM 35**

DATE: 02/16/96 NIGN ENERGY LINE BREAK UNIT 2 PAGE: 6 AUGENTED INSERVICE INSPECTION PLAN d CLASS 2 SCHEDULED CONPONENTS j INSPECTION INTERVAL, PLAN STATUS _PRESERVICE YEAR l FIRST SECcle THIRD l ASIE l PERIOD PERIG) PERIG) l i - SEC. XI l -- - --- - ------ - - ------ ---- l SUMARY EXANINATION AREA CATGY IDE l


0UTAGE


l INSTRUCTIONS l

NUMBER IDENTIFICATION ITEN NO NETN l1 2 1 2 1 2 l

    • CALIBRATION BLOCK"

] FEEDWATER 6 FW-2 095 1303-2 i TDLR VERIFICATION B0uupARY. 109100 TCX 2 2103 16 CF2 UT 1X PIPE 70 ELBOW C5.51 8698 }

    • TBX 35" l.

1 TDLR VERIFICATION BOUNDARY. 109200 TCX 2 2103 17 CF2 UT 1X EL50W 70 PIPE C5.51 2 86988 "TBX 35** i TDLR VERIFICATION BOUNDARY. 109300 TCX 2 2103 18 C F-2 UT 1X t PIPE To ELBOW C5.51 [ 86858 3 "TBM 35** 4 I 109600 TCX 2 2103 19 C F-2 UT 1X TDLR VERIFICATION 90UNDARY. ELBOW TO PIPE C5.51 I WM

    • TSX 35" 1

t i 4 TDLR VERIFICATION BOUNDARY. j 109500 TCX 2 2103 20 CF2 UT 1X i PIPE TO ELBOW C5.51 00238 j "TBX 35" i { 109600 TCX 2 2103 21 CF2 UT 1X TDLR VERIFICATION souleARY. TEE TO PIPE C5.51 a J

    • TBM 35"

) TDLR VERIFICATION BOUNDARY. 109700 TCX 2 2103 22 C F-2 UT 1X'- PIPE TO TEE C5.51 862$8 " TEX 35** a 4 i l

l 1 I J4A /M91-3R0 C$ s fhYeD DATE: 02/16/94 NIGN ENERGY LINE BREAK UNIT 2 PAGE: 7 ) AUGMENTED INSERVICE INSPECTION PLAN CLASS 2 SCNEDULED CIN ONENTS l INSPECTION INTERVAL _ PLAN STATUS ,PRESERVICE YEAR l FIRST SECOND THIRD l ASME l PERILS Petit 3 PERIOD l SEC. XI l"""""-~~~""--""""-*l SU M ART EXAMINATION AREA CATGY NDE l-**---0UTAGE------l INSTRUCTIONS NUMBER IDENTIFICATION ITEM NO METH l1 2 1 2 1 2 l " CALIBRATION BLOCK" FEEDWATER 6 FW-2 095-1303-2 TDLR VERIFICATION 80UNDARY. 109000 TCx 2-2103 23 CF2 UT 1x-VALVE TO PIPE C5.51 86238 " Tax 35" 4 i I TDLR VERIFICATION SOUNDARY. 110000 TCX 2-2103 25 CF2 UT 1x* P!PE TO P!PE C5.51 86238 "TBx 35" FEEDWH ER 6-FW-2 091-2003 2 11100 TCX 2 2103-26 CF2 UT 1x. TDLR VERIFICATION BOUNDARY. VALVE TO P!PE C5.51 J 8623 eergx.34ee -nams r:e- :?

  1. =

w ...e ,a m, ur ,e e, 862 5

    • 99N-34as j

_w 110300 TCX 2 2103 28 CF2 UT 1x-ELBOW 70 P!PE C5.51 86258

    • Tsx 34**

I 110400 TCx 2 2103 29 C-F 2 UT 1x-f PIPE TO ELBOW C5.51 1 e62Sa

    • Tex.34ee 4

110500 TCX 2 2103 30 CF2 UT 1X

\\-

862$a EL80W TO PIPE C5.51

    • Tex 34**

i I 4

DATE: 02/16/96 NIGN ENEaGY LINE BREAK UNIT 2 CA0E9 8 5 AUGIENTED INSERVICE INSPECTION PLAN 4 CLASS 2 SCHEDULED COMPONENTS INSPECTION INTERVAL, PLAN STATUS ,,PRESERVICE YEAR 1 l FIRST SECO2 TNIRD l ASME l PERIOD PERIOD PERIOD l SEC. XI l -- * -- ---------- * ----- --- l stseWtY EXAMINATION AREA CATCY NDE l


0UTAGE------l INSTRUCTIONS NLsEBER IDENTIFICATION ITEM NO METN l1 2 1 2 1 2 l

" CALIBRATION BLOCK" FEEDWATER 6-Fv 2 091 2003 2 110600 TCM 2 2103-31 CF2 UT 1X PIPE TO ELBOW C5.51 86135

    • T8X-34" 110700 TCX 2 2103 32 CF2 UT 1X VALVE TO PIPE C5.51 86188 eeygg.34ee 110000 TCX 2 2103 33 CF2 UT 1X PIPE TO VALVE C5.51 86038 "TSX 34" J

MAIN STEAM.32 Ms 2 002 1303 2 212900 TCX 2 2200 19 C-F-2 UT 1-X TDLR VERIFICATION BOUNDARY. PIPE To PIPE C5.51 877SB " tex 33" l 112950 TcX 2 2200 19L CF2 U1 1-1001 FacM WLD 19 70 23. TDLR X LONG. SEAM C5.52 VERIFICATION BOUNDART. 87758

    • Tex 395*

113300 TCX 2 2200 23 CF2 UT 1-X TDLR VERIFICAT10N Bou eARY. PIPE 70 PIPE C5.51 87758

    • TBX 33" 113550 TCX 2 2200 23L CF2 UT 1-100E FROM W LD 23 70 27. TDLR X

LONG. SEAM C5.52 VERIFICATION ettaCART. 87738 "TBX 33"

E l DATE: 02/16/94 NIGH ENERGY LINE BREAK UNIT 2 PAGE: 9 l AUGMENTED INSERVICE INSPECTION PLAN i CLASS 2 SCNEDULED COMPONENTS INSPECTION INTERVAL, PLM STATUS .PRESERVICE YEAR l l FIRST SECOW TNIRD l ASME l PERIOD PERIOD PERIOD l SEC. XI l - ---- - -- -- - l SumARY EXMINATION AREA CATGY NDE l------0UTAGE -l INSTRUCTIONS NUMBER IDENTIFICATION ITEM No METM l1 2 1 2 1 2 l " CALIBRATION BLOCK'* f i i l MAIN STEM 32 MS 2-002 1303 2 l TDLR VERIFICATION BOUNDARY. 113700 TCX 2 2200 27 CF2 UT 1* X 4 PIPE To PIPE C5.51 877SE

    • TBX 33**

100X FROM WELD 27 70 28. TDLR 113750 TCX 2-2200 27L CF2 UT 1* X LONG. SEM C5.52 VERIFICATION anney, 87788

    • TBX 33**

l TDLR VERIFICATION BOUNDARY. 113800 TCX 2 2200-28 CF2 UT 1-X PIPE TO VALVE C5.51 87785 j TBX.u ) MAIN STEAM 8-MS-2 240-1303-2 'i 114000 TCX 2-2200-30 CF2 UT 1-X TDLR VERIFICATION BOUNDARY. l BRMCN CONNECT 10N 70 PIPE C5.51 ) 878S8

    • TBX 17**

116100 TCX-2 2200 31 CF2 UT 1-X TDLR VERIFICATION BOUNDART. I r!PE 70 VALVE C5.51 l 881S8

    • TBX 17'*

i 4 1 ] 114200 TCX 2 2200 32 CF2 UT 1* X TDLR VERIFICATION BOUNDARY. VALVE TO PIPE C5.51 mu 4

    • TBX 17**

1 ) 114400 TCX 2 2200-34 CF2 UT 1-X TOLR VERIFICATION BOUNDARY. ELBOW TO PIPE C5.51 885S8 " tex-17** ) i

) h DATE: 02/16/94 NIGN ENERGY LI O BREAK UNIT 2 PAGE: 10 AUONENTED INSERVICE INSPECTION PLAN CLASC 2 SCNEDULED Cpr0NENTS 1 1 j INSPECTION INTERVAL,, PLAN STATUS .PRESERVICE YEAR l FIRST SECOW TN!RD l ASIE l PERl(B PERI (B PERitm l SEC. XI l - - -~ -~ - ~ ~ --- ~ ~ ~- ~ -- - l j SUBBWtY EXAMINATION AREA CATGY IDE l--- -. OUTAGE--- -l INSTRUCTIONS NUIGER IDENTIFICATION ITEM No METN l1 2 1 2 1 2 l " CALIBRATION BLOCE** i MAIN STEAM 8-Ms 2 240 1303-2 i TDLR VERIFICATION BOUNDARY. 114500 TCX 2 2200-35 CF2 UT 1 X l P!PE TO VALVE C5.51 j mu

    • TBX 17" MAIN STEAM 6 2003 2 i

TDLR VERIFICATION BOUNDARY. i 114700 TCX 2 2200-37 CF2 UT 1-X BRANCH CONNECTION TO FLANGE C5.51 I 87858

    • TBX 36**

4 i TDLR VERIFICATION BOUICART. 114800 TCX 2 2200 38 CF2 UT 1-X BRANCH COIINECTI0li 10 FLANGE C5.51 j 878st

    • TBX 36**

i 4 TDLR VERIFICAT10ll BOUISARY. 1 114900 TCX 2 2200-39 C F-2 UT 1-X i BRANCH COIIIIECT1011 TO FLANGE C5.51 i 878st i

    • TBX 34**

1 1 4 TDLR VERIFICATICII BOUISART. j 115000 TCX-2 2200-40 CF2 UT 1-X BRANCH CDIMIECTf 41 TO FLANGE C5.51 878$8

    • TBX 36" i

NAlW STEAM NS 24 (DRIP POT) ) TDLR WERIFICATION BOUNDARY. 115200 TCX 2 2200 66 CF2 UT 1-X BRANCH CONNECTICII TO PIPE C5.51 876SB J

    • TBX 22" i

I. 3 4

DATE: 02/16/94 N!GM ENERGT LINE BREAK UNIT 2 PAGE: 11 AUGENTED INSERVICE INSPECTION PLAN 1 CLASS 2 CCNEDULED COMPCNENTS INSPECTION INTERVAL, PLAN STATUS _PRESERVICE TEAR l FIRST SECOW TNIRD l ASE l PERIOD.' PERIIB PERIG) l l 'SEC. XI l-----............................l Sule4 ART EXANINATION AREA CATGT ICE l------0UTASE-


l INSTRUCTIONS NUMBER 1DENTIFICATION ITEM No METN l1 2 1 2 1 2 l

    • CALIBRATION BLOCK'*

] NAIN STEAM MS 24 (DRIP POT) TOLR VERIFICATION BOUNDART. 115300 TCX 2 2200-67 CF2 UT 1-X PIPE TO CAP C5.51 87438

    • TBX 22**

FEEDWATE2 18 FW-2-035 2003-2 118000 TCX 2 2202 1 C-F 2 UT 1-X i MOMENT RESTRAINT 70 PIPE C5.51 85 8.

    • TSX 38**

918100 TCX 2 2202 2 CF2 UT 1-X PIPE 70 VALVE C5.51 85688 "T8X 38** I l 198200 TCX 2 2202 3 C-F 2 UT 1-X VALVE TO PIPE C5.51 l 85688 "TBM 38** l l l 118300 TCX 2 2202 4 C F-2 UT 1-X P!PE TO VALVE C5.51 85688 "TBM 3@ J 118400 TCx 2 2202 5 CF2 UT 1-X TDLR VERIFICAfl0N BOUNDART. VALVE 70 PIPE C5.51 85688

    • TSX 30**

i j FEEDWATER 18 FW 1 018-1303 2 Y30 TCX 2 2202 6 CF2 UT 1-X TDLR VERIFICATION BOUSART. PIPE TO PIPE C5.51 8568s "T8X 21"

l l DATE: 02/16/94 NIGH ENERGT LINE BREAK UNIT 2 PAGE: 12 AUGENTED INSERVICE INSPECTICN PLAN CLASS 2 SCNEDULED COMPONENTS INSPECTION INTERVAL, PLAN STATUS ,PRESERVICE YEAR l FIRST SEColS TNIRD l l ASME' l PEtitD PERIOD PER100 l l SEC. XI l - ----- - --- - -- -- --- -- l

SUMMARY

EXAMINATION AREA CATGY NDE l-**---00TAGE ---*-l INSTRUCTIONS NUMBER IDENTIFICATION ITEM NO DETM l1 2 1 2 1 2 l

    • Call 0 RATION BLOCK'*

1 FEEDWATER 18-FW 2-018 1303-2 TOLR VERIFICtTION BOUNDART. 118600 TCX 2 2202 7 CF2 UT 1* X PIPE To PIPE C5.51 85688 "TBX 21" FEEDWATER 6 FW 2-092-2003 2 122000 TCX 2 2204 2 C F 2 ' UT 1-X BRANCN CONNECTION TO PIPE C5.51 j a5758 i i eeygg.34 l l 122100 TCX 2 2204-3 CF2 UT 1-X l PIPE To VALVE C5.51 ( 86055 s l "TBX 34** i l 122200 TCX 2 2204 4 C-F 2 UT 1-X l VALVE TO PIPE C5.51 8618s

    • tex 34**

122300 TCX 2 2204 5 C F-2 UT 1-X PIPE TO ELBOW C5.51 86288

    • TBX 34**

i I 122500 TCX 2 2204 7 CF2 UT 1-X PIPE TO ELt0W C5.51 86338

    • TEX 34**

l 122600 TCX 2 2204 8 C F-2 UT 1-X l ELBOW TO PIPE C5.51 86388 "TBX 34** [

DAYE: 02/16/96 NIGN ENERGY LINE BREAK UNIT 2 PAGE: 13 AUGENTED INSERVICE INSPECTION PLAN class 2 SCHEDULED COMPONENTS INSPECT!0N INTERVAL, PLAN STATUS _PRESERVICE YEAR l FIRST SECO2 TNIRD l ASE l PERits PERim PERIED l SEC. XI l - - - -- -- *--- -- --- ------- l

SUMMARY

EXAMINATION AREA CATGY NDE ( --0UTAGE----**l INSTRUCTIONS NUMBER IDENTIFICATION ITEM No METH l1 L 1 2 1 2 l

    • CALitRATION BLOCK" FEEDWAYER 6-FW-2 092 2003 2 122700 TCX 2 2204 9 CF2 UT 1-X PIPE TO VALVE C5.51 86358
    • TBX 34" FEEDWA1ER 6-FU-2-096-1303-2 TDLR VERIFICATION SOU WARY.

122900 TCX-2-2204 11 CF2 UT 1-X PIPE To PIPE C5.51 86388 "TBX 35" TDLR VERIFICATION poumARY. 123000 TCX 2 2206-12 C-F 2 UT 1-X PIPE TO VALVE C5.51 863ss "TsX 35** TDLR VERIFICAfl0N BOUNDART. 123100 TCX 2 2204 13 CF2 UT 1-X VALVE TO PIPE C5.51 86338 "TBM 35" 123200 TCX 2 2204 14 CF2 UT 1-X TDLR VERIFICATION BOUNDARY. PIPE TO TEE C5.51 86338

    • TBX 35**

123300 TCX 2 2204-15 CF2 UT 1-X TDLR VERIFICATION BOUNDARY. TEE TO P!PE C5.51 86338 " Tax 35" 123500 TCX 2 2204 17 CF2 UT 1-X TDLR VERIFICATION 90U SARY. ELBOW TO PIPE C5.51 86388

    • TtX 35**

l 2

i DATE: 02/16/96 NIGN ENERGY LINE BREAK UNIT 2 PAGE: 14 AUGNENTED INSERVICE INSPECTION PLAN CLASS 2 SCNEDULED CIBIPONENTS 4

  • NSPECTION INTERVAL,

PLAN STATUS _PRESERVICE YEAR l FIRST SECOW TNIRD l ] ASIE l PERIOD PER!tB PERitB l SEC. XI l - - *----- ---- ------ - ----- -- l 4 i SLeetARY EXAMINATION AREA CATGY DE l-- 0UTAGE------l INSTRUCTIONS i NUMBER IDENTIFICATirus ITEM NO METH l1 2 1 2 1 2 l " CALIBRATION BLOCX** ] J FEEDWATER 6-FW-2-096-1303-2 1 TDLR VERIFICATION BOU S ARY. 123600 Trit 2-220418 CF2 UT 1-X PIPE To ELBOW C5.51 5 86088 } "TBX 35" TDLR VERIFICATION BOUNDARY. 123700 TCX 2 2204 19 CF2 UT 1-X EL90W TO PIPE C5.51 2 87088 i

    • TBX 35**

] J TDLR VERIFICATION BOUNDARY. j 123800 TCX 2 2204 20 C 7-2 UT 1-X PIPE TO ELBOW C5.51 ) s7oss i

    • tex-35" l.

3 1 i 123900 TCX-2 2204 21 C F-2 UT 1-X TDLR VERIFICATION BOUNDARY. j ELs0W 70 PIPE C5.51 8685: "TsX 35** 124000 TCX 2 2204 22 C F-2 UT 1-X TDLR VERIFICATION BOU SARY. l PIPE 10 ELBOW C5.51 8658s )

    • TBX 35**

124100 TCX 2 2204 23 C-F 2 UT 1-X TDLR VERIFICATION 00UNDARY. 3 ELBOW To PIPE C5.51 86488 "TBM 35** 2 124200 TCX 2 2204 24 CF2 UT 1-X TDLR VERIFICAfl0N 90UNDARY. I PIPE TO EL80W C5.51 86455 1

    • TtX 35**

i i d )

d 1 DATE: 02/16/94 NIGH ENERGY LINE GREAX UNIT 2 PAGE: 15 AUGMENTED INSERVICE INSPECTION PLAN CLASS 2 SCHEDULED COMPONENTS INSPECil0N INTERVAL, PLAN STATUS ,PRESERVid YEAR 3 l FIRST SECOND TNIRD l ASIE l PERl(D PERI (2 PERl(D l SEC. XI l --- - - - l SLMMARY EXAMINATION AREA CATGY NDE l--*---0UTAGE------l INSTRUCTIONS ) i NUMBER IDENTIFICATION ITEM No METN l1 2 1 2 1 2 l

    • CALIBRATION BLOCx"

) 4 4 FEEDWATER 6 FW-2 096 1303-2 1 TDLR WRIFICATION BOUNDARY. 126300 TCX 2 2204 25 CF2 UT 1 x ELBOW To PIPE C5.51 864S8

    • TSX 35**

1 i TDLR WRIFICATION BOUNDARY. 124400 TCX 2 2204 26 C F-2 UT 1-x 1 PIPE To P!PE C5.51 4 864S8 " Tax 35" 4 .1 i MAIN STEAM 32-MS-2 003-1303 2 I TDLR WRIFICATION BOUNDARY. X 129700 TCx 2 2300-18 C F-2 UT 1-P!PE TO PIPE C5.51 87758 1

    • TBx 33**

i 1 1005 FRON W LD 18 TO 22. TDLR i 129750 TCx 2 2300 18L CF2 UT 1-X l LONG. SEAM C5.52 WRIFICATION BOUNDART. l 87758

    • Tax *33**

j 4 i TDLR WRIFICATION BOUNDARY. j j 130100 TCX 2 2300 22 CF2 UT 1-X 1 PIPE TO PIPE C5.51 ) l 877$8 Tex.33 1 ) i 1001 FROM E LD 22 TO 26. TDLR 130150 TCX 2 2300-22L C F-2 UT 1-X LONG. SEAM C5.52 WERIFICATION BOUseARY. I 87758

    • TSX 33**

i TDLR WRIFICATION BOUNDARY. 130500 TCX 2 2300 26 CF2 UT 1-X t PIPE TO P!PE C5.51 87758

    • Tsx 33**

i 4 i

i DATE: 02/16/96 NISH ENERGY LINE BREAK UNIT 2 PAGE: 16 AUSENTED INSERVICE INSPECTION PLAN CLASS 2 SCHEDULED COMPONENTS INSPECTION INTERVAL,, PLAN STATUS ,PRESERVICE YEAR l FIRST SEcom TNIRD l ASME l perle Pftle PERIS l SEC. XI l -- - -- -- - - -- -------- - l

SUMMARY

EXAMINATION AREA CATGY NDE l -- -0UTAGE--

  • l INSTRUCTIONS NUMBER IDENTIFICATION ITEM No METN l1 2 1 2 1 2 l

" CALIBRATION BLOCK" MAIN STEAM 32-MS-2-003 1303-2 1005 FROM WLD 26 70 27. TDLR 130550 TCX 1. 2300 26L CF2 UT 1-X LONE. SEAM C5.52 WRIFICAfl0N BOUNDARY. 87735 "TSM 33" TDLR VERIFICATION BOUNDARY. X 130600 TCX 2 2300-27 CF2 UT 1-PIPE TO VALW C5.51 87758 "TSM 33" 130700 TCM 2 2300-28 CF2 UT 1-X VALVE To M01ENT RESTRAINT C5.51 87758 " Tex-33" MAIN STEAM MS 23 (DRIP POT) i 130900 TCM 2 2300-30 CF2 UT 1-TDLR WRIFICATION 80um ARY. X PIPE To CAP C5.51 4 8738: "TSK 22" MAIN STEAM 8-MS 2 223 1303 2 131100 TCX 2 2300 32 CF2 UT 1-TDLR WRIFICATION souMDART. X PIPE TO VALW C5.51 80088 "TBM 17" 131200 TCX 2 2300-33 CF2 UT 1-TDLR VERIFICATION BOUIENutY. X VALW 70 PIPE C5.51 88358 " Tax 17"

DATE: 02/16/94 HIGH EWfRGY LIII BREAK UNIT 2 PAGE: 17 I AUGMENTED INSERVICE INSPECTION PLAN f CLASS 2 SCHEDULED COMPONENTS a j INSPECTION INTERVAL,, PLAN STATUS .PRESERVICE YEAR l FIRST SECOND TNIRD l ASME l PERIOD PERIG) PERIOD l 3 l SEC. XI l -- - - - - -- --- - --------- l 5 $UMMARY EXAMINATION AREA CATGY NDE l--- --0UTAGE- --l INSTRUCTIONS i NUMBER IDENTIFICATION ITEM No METN l1 2 1 2 1 2 l

    • CALIBRATION BLOCE**

MAIN STEAM B MS 2 223 1303-2 i TDLR VERIFICATION BOUNDARY. X 131300 TCX 2 2300-34 C F-2 UT 1-PIPE TO ELBOU C5.51 BB4SB

    • TBX 17"

) TDLR VERIFICATION BOUNDARY. j 131400 TCX 2 2300-35 CF2 UT 1-X ELBOW To PIPE C5.51 1 mm l

    • TBX 17**

I TDLR VERIFICATION BOUNDARY. 131500 TCX 2 2300 36 CF2 UT 1-X j PIPE To VALVE C5.51 mu

    • TBX 17" l

i MAIN STEAM 6 2003-2 TDLR VERIFICATION BOUNDARY. 131600 TCX 2 2300-37 C72 UT 1-X I BRANCN CONNECTION TO FLANGE C5.51 878SB

    • TBX 36**

i i TDLR VERIFICATION ROUNDARY. j 131700 TCX 2 2300 38 CF2 UT 1-X BRANCH CONNECTION TO FLANGE C5.51 j 87853

    • TBX 36**

i l l ] 131800 TCX 2 2300 39 C F-2 UT 1-TDLR VERIFICATION BOU SARY. X BRANCN CONNECTION TO FLANGE C5.51 87855

    • TBX 36**

i i 131900 TCX 2 2300 40 CF2 UT 1-TOLR VERIFICATION BOU SARY. X BRANCN ComECTION 70 FLt.NGE C5.51 j 87855

    • TBM 36" i

i 1

4 DATE: 02/16/94 N!GN ENERGY LINE BREAE UNil 2 PAGE: 18 AUGENTED INSERVICE INSPECTION PLAN l CLASS 2 SCNEDULED CtplPONENTS i f INSPECTION INTERVAL, PLAN STATUS ,PRESERVICE YEAR j l FIRST SECOW Tule j ASIE l PERINI PERllB PERIOD l SEC. XI ] - ------- - ** - - - ---------- l timasamY EXAMINATION AREA CATGY WE l*-----0UTAGE ---l INSTauCTIONS NUMBER IDENTIFICATIcel ITEM NO METH l1 2 ,1 2 1 2 l " CALIBRATION BLOCX** i l MAIN STEAft MS-23 CDRIP POT) j TDLR VERIFICATION 00U SART. 132100 TCX 2 2300 62 CF2 UT 1-X a i PIPE To PIPE C5.51 ans .eygg.22** 1 k IIIPWaVER 1s FW-2-017-1303 2 TDLR VERIFICATI0ll BOUS ARY. 134800 TCX 2 2301 27 C-F 2 UT 1-X l PIPE To PIPE C5.51 i e56m I " TEX 21" 1 i i TDLR VERIFICATION BOUNDART. i 134900 TCX 2 2301-28 CF2 UT 1-X ) PIPE TO PIPE C5.51 i asess t "TSX 21" i 1 FEEDWATER 18-FW-2 034 2003-2 1 4 5 135000 TCX 2 2301 29 CF2 UT 1-TDLR VERIFICATION BOUNDARY. X I PIPE TO VALVE C5.51 a56Ss

    • Tex 30**

I i i 135100 TCX 2 2301-30 CF2 UT 1-X j VALVE TO P!PE C5.51 j 85688 1 " Tax 30** ] i j 135200 TCX 2 2301 31 CF2 UT 1-X PIPE 70 VALVE C5.51 i 85658 "TsX 30** i ) 4 )

_= l DATE: 02/16/94 NIGN EIIERGY LINE BREAK UNIT 2 PAGE: 19 AUGENTED INSERVIN INSPECTION PLAN CLASS 2 SCHEDULED COMPONENTS INSPECTION INTERVAL, PLAN STATUS _PRESERVICE TEAR l FIRST SECOND TNIRD l ASIE l PERIS PEtttB PEtttB l SEC. XI l -- - - - ---*- --- -- -- - - l SUIstARY EXAMINATION AREA CATGY IDE l --- -0UTAGE --l INSTRUCTIONS i lasIRER IDENTIFICATION ITEN 110 METN l1 2 1 2 1 2 l " CALIBRATION BLOCK" FEEDWAftR 18 FW-2 034 2003-2 i X 135300 TCX 2 2301 32 CF2 UT 1-VALVE TO PIPE C5.51 85688 " Tax 38" X 135400 TCX 2 2301-33 C F-2 UT 1-PIPE To leOMENT RESTRAINT C5.51 85688 " tex 38" i FEEDWATER 6-FW 2-093-2003-2 X 138700 TCX 2-2303 2 C72 UT 1-l BRANCN CONNECTION 70 PIPE C5.51 8568: "TBM 34" 138000 TCX 2 2303 3 CF2 UT 1-X PIPE TO VALVE C5.51 l 85888 "T8X 34" l 138900 TCX 2 2303 4 CF2 UT 1-X VALVE TO PIPE C5.51 mm j "TBX 34" 139000 TCx 2 2303 5 CF2 UT 1-X PIPE 70 ELs0W C5.51 l 86280 l "T8X 34" l i 139200 TCx 2 2303 7 C-F 2 UT 1-X PIPE To ELBOW C5.51 86388 "TSM 34" i I

i 4 DATE: 02/16/96 klGN ENERGT LINE BREAK UNIT 2 CADE: 20 AUWFNTS INSERVIM INSPECTION PLAN ] CLASS 2 SCHEDULG CCBFONENTS t i INSPECTION INTERVAL, PLAY STATUS _ PRE NRVICE TEAR l l FIRST SECom TNIS l j ASME l PERIOD PERIOD PERIOD l j SEC. XI l --- ----- --- ---- - --- - ----- l j SUMMART EXAMINATION AREA CATGT BE l----- 0UTAGE------l INSTauCT10NS j NUNeER IDENTIFICATION ITEN NO M TN l1 2 1 2 1 2 l

    • CALIBRAT;JN SLOCK'*

a I i f FEEDWATER 6-FW-2-093 2003 2 I i 139300 TCM 2 2303 8 CF2 UT 1-X h ELBOW TO PIPE c5.51 i a63m } "TSM 34** 1 l 13960C TCX 2 2303 9 CF2 UT 1-X i PIPE TO VALVE C5.51 i j 8638s l

    • T8X 36**

a 1 TDLR W RIFICATION BOUSART. 139500 TCX 2 2303 10 CF2 UT 1-X k VALVE TO PIPE C5.51 i mm l

    • TSM 34**

1 J l j FEEDWATER 6-FW-2 097-1303-2 i l 139600 TCX 2 2303-11 CF2 UT 1-TDLR VERIFICATION 90U MART. X j PIPE TO PIPE C5.51 l 86338 l " Tex 35** 139000 TCX 2 2303 13 CF2 UT 1-TDLR VERIFICATION ROUSART. X j VALVE TO PIPE C5.51 i mM "TBN 35** t 139900 TCX 2 2303 14 C-F 2 UT 1-TDLR W RIFICATION BOU SART. X 4 PIPE TO TEE C5.51 j EN i "TSM 35" i i TDLR VERIFICATION BOUSART. 160000 TCX : 2303 15 CF2 UT 1-X f TEE To PIPE C5.51 ma

    • T8X 35**

lj i l, i

i i DATE: 02/16/94 NIGN ENERGY LINE BREAK UNIT 2 PAGE: 21 AUGMENTED INSERVIM INSPECTION PLAN CLASS 2 SCHEDULED CIMPONENTS INSPECTION INTERVAL,, PLAN STATUS _PRESERVI N YEAR l FIRST SECOW TNIRD l l ASME l PERIOD PERIOD PERIIB l l SEC. XI l----"-*----------l

SUMMARY

EXAMINATION AREA CATGY NDE l- -0UTAGE------l INSTRUCTIONS ] NUMBER IDENTIFICATION ITEM No METH l1 2 1 2 1 2 l

    • CALIBRATION BLOCK'*

FEEDWATER 6-FW-2 097 1303 2 TDLR VERIFICATION BOUNDARY. 140100 TCX 2 2303 16 C-7 2 UT 1-X PIPE 10 EL30W C5.51 i 86388

    • TtX 35**

i TDLR VERIFICATION BOUNDARY. 140200 TCX 2 2303 17 CF2 UT 1-X 2 EL90W TO PIPE C5.51 l WM eerg.35** 4 TDLR WRIFICATION BOUSARY. 140300 TCX 2 23S3 18 C F-2 UT 1-X l PIPE TO FIPE C5.51 i f4658

    • TBM 35**

J TDLR WRIFICATION BOUNDARY. i 140400 TCX 2 2303 19 CF2 UT 1-X PIPE TO EL30W C5.51 86958 4 4 T. 35 i e f 140500 TCX 2 2303 20 CF2 UT 1-TDLR WRIFICATION BOUNDARY. X ELBOW TO PIPE C5.51 870S8 l

    • Tex 35**

s i 160600 TCX-2 2303 21 C-F 2 UT 1-TDLR WRIFICATION BOUSARY. X j PIPE TO ELBOW C5.51 8705s i eeyg.35** 140700 TCX 2 2303 22 CF2 UT 1-TDLR WRIFICATION BOUSARY. X EL30W TO PIPE C5.51 l 86958 i 1

    • Tg.35**

i

1 DATE: 02/16/94 NIGN ENERGY LINE BREAK UNIT 2 PAGE: 22 l AumENTED INSERVICE INSPECTICW PLAN CLASS 2 SCNEDULED COMPONENTS 4 i INSPECTION INTERVAL, PLAN STATUS _PRESERVICE YEAR l FIRST SECOND TNIRD l l AspE l PERIOD' PERIOD PERIOD l l SEC. XI l--------------------------l l

SUMMARY

EXANIMATION AREA CATGY NDE l------0UTAGE--- --l INSTRUCTIONS NUMBER IDENTIFICATION ITEN ho NETH l1 2 1 2 1 2 l

    • CAL 10 RATION BLOCK'*

l j { FEEDWATER 6 FU-2-097 1303-2 } TDLR WRIFICATION BOUNDARY. 140000 TCx 2 2303 23 CF2 UT 1-X r PIPE TO ELBOU C5.51 j 865ss

    • TBM 35" I

) 160900 TCX-2 2303 24 CF2 UT 1-TDLR WRIFICATION BOUNDARY. X 5 EL90W TO PIPE C5.51 l Em T.x.35 t i TDLR WRIFICATION BOUWARY. 161100 TCX 2 2303 26 CF2 UT 1-X I EL50W TO PIPE C5.51 l mm

    • TBM 35**

4 d 141200 TCX 2 2303 27 CF2 UT 1-X TDLR WRIFICATION BOUWARY. l PIPE 70 PIPE C5.51 i 86438 i

    • Tu 35**

i j 144920 TCx 2-2303 65 CF2 UT 1-X TDLR WRIFICATION BOUWARY. 3 P!PE TO PIPE C5.51 i t 864ss

    • TBX 35**

l i j 144940 TCX 2 2303-66 CF2 UT 1-TDLR WalFICATION acuMDARY. X PIPE TO PIPE C5.51 t 864ss

    • Tu 35**

MAIN STEAM 32 MS-2 006 1303-2 ) 146600 TCM 2 2400 17 CF2 UT 1-X TDLR WRIFICATION BOUWARY. PIPE TO PIPE C5.51 87758 l "TBM 33" k

DATE: 02/16/94 NIGN ENERGY LINE BREAK UNIT 2 PACE: 23 AUGIGNTED INSERVICE INSPECTION PLA:s CLASS 2 SCHEDULED COMPONENTS INSPECTION INTERVAL PLAN STATUS _PRESERVICE YEAR l FIRST SECOW TNIRD l ASIE l PERIOD PERIOD PERIOD l SEC. XI l - --- --- - -- - - l

SUMMARY

EXAMINATION AREA CATGY NDE l- -0UTAGE------l INSTRUCTIONS NUMBER IDENTIFICATION ITEM NO METN l1 2 1 2 1 2 l

    • CALIRRATION BLOCK **

i llAIN STEAM 32 MS 2 004 1303 2 X 100X FROM WLD 17 TO 19. TDLR 146650 TCX 2 2400 17L CF2 UT 1 LONG. SEAM C5.52 VERIFICATION SOUNDARY. 877$8

    • TBM 33" X

TDLR VERIFICATION pouMDARY. 146800 TCX 2 2400 19 CF2 UT 1-P!PE TO P!PE C5.51 877$8 I "TBM 33** l l 1 X 1005 FROM W LD 19 TO 25. TDLR l 146850 TCX 2 2400 19L CF2 UT 1-LONG. SEAM C5.52 VERIFICATION 90USARY. 87758

    • TBM 33**

X TDLR VERIFICATION BOUNDARY. 167000 TCX 2-2400-25 CF2 UT 1-l P!PE TO P!PE C5.51 877$8

    • TBX 33" X

1001 FROM W LD 25 70 56. TDLR 147650 TCX 2 2400 25L CF2 UT 1-LONG. SEAM C5.52 VERIFICATION 90UNDARY. 87758

    • TBX 33**

X 92 SELECTED FOR ISI. 1005 FROM 147550 TCX 2-2400-26L CF2 UT 1-LONG. SEAM C5.52 W LD 56 70 26. TDLR 877$8 VERIFICATION BOLARMRY.

    • TBX 33**

1 167600 TCX 2 2400 27 CF2 UT 1-X VALVE TO MONENT RESTRAINT C5.51 87788

    • TBM 13**

.= _.__. ? 1 DATE: 02/16/94 NIGN ENERGY LINE BREAE UNIT 2 PAGE: 24 J AUSENTED INSERVICE INSPECTION PLAN l l CLASS 2 SCNEDULED COMPONENTS i i I INSPECTION INTERVAL,, PLAN STATUS _PRESERVICE YEAR l l FIRST SECIEW TNIRD l l ASE l PERltD PERICD PERIS l i SEC. XI l - l I Su m 4RY EXANINATION AREA CATGY NDE l 0UTAGE-- --l INSTRUCTIONS NUNBER IDENTIFICATION ITEM NO METN l1 2 1 2 1 2 l " CALIBRATION BLOCX" l. MAIN STEAM MS-26 (DRIP POT) X TDLR VERIFICATION SOUSARY. S47800 TCX 2 2400 29 CF2 UT 1-PIPE To CAP C5.51 i 87488 I

    • TBX 22" t

I-MAIN STEAM 8-MS-2 274 1303 2 i X TDLR VERIFICATION BOUNDAAY. 147900 TCX 2 2400 30 C F-2 UT 1-BRANCN CONNECTION TO PIPE C5.51 4 87388

    • TBM 17" X

TDLR VERIFICATION BOUNDARY. 148000 TCX 2 2400 31 CF2 UT 1-PIPE TO VALVE C5.51 i 87838 i "TBX 17** i 4 ] X TDLR VERIFICATION 00LASARY. 148100 TCX 2 2400 32 CF2 UT 1-VALVE TO PIPE C5.51 1 i 87955 f "TBM 17'* I i 148200 TCX 2 2400 33 CF2 UT 1-X TDLR VERIFICATION 90USARY. f PIPE TO EL30W C5.51 ] WM

    • T8X 17**

i 4 .TCX 2 2400 34 C-F 2 UT 1-X TDLR VERIFICATION BOU WARY. j 148300 i EL90U TO PIPE C5.51 ] WM "TtX 17" 1 1 148400 TCX 2 2400-35 CF2 UT 1-X TDLR VERIFICATI0g amany, PIPE TO VALVE C5.51 8s58: i

    • T8X 17'*

1i e i 1

s 1 j DATE: 02/16/96 NIGN ENERGY LINE BREAK UNIT 2 PAGE: 25 l AUSENTED INSERVICE INSPECTION PLAN j CLASS 2 SCNEDULED COMPCNEWTS l i l INSPECTION INTERVAL., PLAN STATUS _ ,PRESERVICE YEAR l l FIRST SECOND TNIRD l j ASIE l PERIOD PERIOD PERIOD l l SEC. XI l - ------ -- -- --- --- -- ---- l SUNNARY EXAMINAfl0N AREA CATGY NDE l------0UTAGE------l INSTRUCT!cNS f l NUMBER IDENTIFICATION ITEN No METN l1 2 1 2 1 2 l

    • CALIBRATION BLOCK" d

MAIN STE m 6 2003 2 4 148500 TCX 2 2400 M CF2 UT 1-X TDLR WRIFICATION BOUSARY. 1 j SRANCN CONNECTION To FLANGE C5.51 a798s eeyg. gee i i l X TDLR WRIFICAfl0N BOUNDART. ( 148600 TCX 2 2400 37 CF2 UT 1-j BRANCN CONNECTION TO FLANGE C5.51 87985 "T8X M** i ) 144700 TCX 2 2400 38 CF2 UT 1-X TDLR WRIFICATION SOUSARY. BRANCN CONNECTION TO FLANGE C5.51 i s798s eetg. gee l X TDLR WRIFICATION BOUNDARY. 148800 TCX 2 2400-39 CF2 UT 1-i BRANCH CONNECTION To FLANGE C5.51 1 87988 4 4 "Tu M** I i J i X TDLR WRIFICATION 00MWARY. i 148900 TCX 2 2400-40 CF2 UT 1-I BRANCN CONNECT 10N TO FLANGE C5.51 l 879Bs j Tm.M" \\

i MAIN STEAfs 32-MS 2-004 1303-2 148950 TCX 2 2400 M CF2 UT 1-X TDLR VERIFICATION BOUS ARY.

PIPE TO PIPE C5.51 8T758 " TEX 33** i i i FEEDWATER 18-FU-2 020 1303 2 4 4

  • 0100 TCX 2 2401 11 CF2 UT 1-TDLR W RIFICATION BOUSART.

X PIPE 70 P!PE C5.51 1 j N "T8X 21" i i

i DATE: 02/16/94 NIGN EWRGY LINE BREAK UNIT 2 PAGE: 26 ALNBENTED INSERVICE INSPECTION PLAN i CLASS 2 SCNEDULED CG r0NENTS INSPECTION INTERVAL, PLAN STATUS _PRESERVICE YEAR l FIRST SECOs TNIRD l 1 ASE l PCRits PER!ls Perils l ) SEC. XI l - - - ---*---- - -- -------- l

SUMMARY

EXAMINATION AREA CATGY NDE l=*-**-0UTAGE-


l INSTRUCTIONS NUMBER IDENTIFICATION ITEM N0 METH l1 2 1 2 1 2 l

" CALIBRATION BLOCK" i s FEEDWATER 18 FW-2 020 1303-2 i TDLR VERIFICATION BOUNDARY. X j 150200 TCX 2 2401 12 CF2 UT 1-PIPE TO PIPE C5.51 ] 8568: "TtX 21" 4 l FEEDWATER 18 FW-2-037 2003 2 4 TDLR VERIFICATION 00uMDARY. X 150300 TCX 2-2401 13 C F-2 UT 1-I PIPE TO VALVE C5.51 85685 "TtX 30" l i X 150400 TCX 2 2401 14 CF2 UT 1-a ] VALVE TO P!PE C5.51 856Ss "TBX38" l i ) 150500 TCX-2 2401 15 CF2 UT 1-X I j PIPE TO VALVE C5.51 I i 85688 f

    • tex 38" l

i 150600 TCX 2 2401 16 CF2 UT 1* X i VALVE TO PIPE C5.51 i j 85688 "TsX-38" i i 150700 TCX 2 2401 17 CF2 UT 1-X i PIPE To MOMENT RESTRAINT C5.51 } 85658 i "TBX 38" 1 FEEDWTER 6 FW 2 094 2003 2 %700 TCX 2 2403 2 CF2 UT 1-X ] SRANCH CONNECTION TO PIPE C5.51 " tex 34** 1 4

= -.. ) i i DATE: 02/16/94 NIGN ENERGY LINE BREAK UNIT 2 PAGE: 27 I } AUGMENTED INSERVICE INSPECTION PLAN j j CLASS 2 SCNEDULED COMPONENTS J INSPECTION INTERVAL. PLAN STATUS _PRESERVICE YEAR l FIRST SECOS TNIRD l ASIE l PERIOD PERIOD PEkl0D l SEC. XI l ---- -- - --- - - - l j 3

SUMMARY

EXAMINATION AREA CATGY NDE l--==--0UTAGE-- --l INSTRUCTIONS i MUMBER IDENTIFICATION ITEM No METN l1 2 1 2 1 2 l

    • CALitRATION BLOCK **

j FEEDWATER 6 FW-2-094 2003 2 1 X 154900 TCX 2 2403 4 CF2 UT 1-VALVE TO PIPE C5.51 86155 1

    • TBX 34**

i J 1 X 155000 TCX 2-2403-5 CF2 UT 1-j PIPE To ELP9W C5.51 86288 eerex.34 5 X 155100 TCX 2-2403-6 CF2 UT 1-i ELBOW TO PIPE C5.51 86sse i

    • T8X-34**

j i, l 155300 TCX 2 2403 8 CF2 UT 1-X I ELBOW TO PIPE C5.51 86388 t

    • tex 34**

1 t 155400 TCX 2 2403-9 CF2 UT 1-X PIPE TO VALVE C5.51 86338

    • TBX 34**

4 i i S55500 TCX 2 2403 10 CF2 UT 1-TDLR VERIFICATION BOU S ARY. X d VALVE TO PIPE C5.51 i W 88 i \\

    • Tex 34**

1 i i FEEDWATER 6 FW-2 098 1303 2 155600 TCX 2-2403 11 CF2 UT 1-TDLR VERIFICAT10M BOU SARY. X PIPE TO PIPE C5.51 86288

    • TsX 35**

1 A i

m -.,u s.o m.. m DATE: 02/16/96 NIGN EN RGY LINE BREAK UNIT 2 PAGE: 28 AUOM NTED INSERVICE INSPECTION PLAN CLASS 2 SCNEDULED COMPONENTS INSPECTION INTERVAL, PLAN STATUS ,PRESERVICE YEAR l FIRST SECOS TNIRD l ASIE l PERIOD PERIOD PERIOD l l SEC. XI l +- - ---- -- ------- ----- -- -- l SupeWtY EMANINATION AREA CATGY NDE l*- 0UTAGE--* -*l INSTRUCTIONS NuneER IDENTIFICATION ITEN No NETN l1 2 1 2 1 2 l " CALIBRATION BLOCE** FEEDWATER 6 FU 2-098 1303-2 TDLR VERIFICATION BOUNDARY. X 155700 TCX 2 2403 12 CF2 UT 1-P!PE TO VALW C5.51 86288 eeygg 35ee TDLR VERIFICATION BOUNDARY. X 155800 TCX-2-2403 13 CF2 UT 1-VALVE TO PIPE C5.51 8628s

    • TBM 35" TDLR VERIFICATION BCUNDARY.

X 155900 TCX 2 2403 14 C.F 2 UT 1-PIPE TO TEE C5 51 i 862$8 ?

    • Tag 35**

TDLR WRIFICATIJN BOUNDART. 156000 TCX 2 2403 15 C72 UT 1-X TEE 70 PIPE C5 51 86288 " Tex 35" TDLR VERIFICATION BOUNDART. 156100 TCX 2 2403 16 CF2 UT 1-X PIPE TO ELECW C5.51 86288 eeygg 35** TDLR WRIFICATION BOUSARY. 156200 TCX 2 2403 17 CF2 UT 1-X ELBOW TO PIPE C5.51 86380 "TSN 35" TDLR VERIFICATION BOUWART. 156300 TCX 2 2403 14 CF2 UT 1-I PIPE 70 ELBOW C5.51 86988 "TSK 35" l l l

DATE: 02/16/94 NIGN ENERGY LIU BREAK UNIT 2 PAGE: 29 AUGEENTED INSERVICE INSPECTION PLAN CLASS 2 SCNEDULED @MPCNENTS INSPECTION INTERVAL, PLAN STATUS _PRESERVICE YEAR l FIRST SEcom TNIRD l ASIE l PERIG) PERIG) PERI @ l SEC. XI l - - -*-- -- - --- -- l Supe 4ARY EXAN! NATION AREA CATGY SE l---- -0UTAGE---- -l INSTRUCTIONS NUNBER IDENTIFICATION ITEN No NETH l1 2 1 2 1 2 l "CALIBRAT!0N BLOCK" l FEEDWATER 6 FW-2-0% _1303 2 l TDLR VERIFICATION BOUNDARY. X 156400 TCX 2 2403 19 C F-2 UT 1 ELBOW TO PIPE C5.51 870$s "T8X 35" TDLR VERIFICATION 90UIDARY. X 156500 TCX 2 2403 20 CF2 UT 1-PIPE To ELBOW C5.51 87088

    • TBM 35**

TDLR VERIFICATION 90UNDARY. 156600 TCX 2 2403 21 C-F-2 UT 1-X EL50W TO PIPE C5.51 86998 " tex 35** TDLR VERIFICATlog armamany, 156700 TCX 2-2403 22 CF2 UT 1-X P1PE TO ELBOW C5.51 865SB

    • TBM 35" TDLR VERIFICATION 90USARY.

156800 TCX 2 2403 23 CF2 UT 1-X ELBOW 70 PIPE C5.51 86438

    • TSX 35**

157000 TCX 2 2403-25 CF2 UT 1-TDLR VERIFICATION BOUSARY. X ELBOW TO PIPE C5.51 86458

    • TEX 35**

157100 TCX 2 2403 26 CF2 UT 1-TDLR VERIFICATION BOUSARY. X PIPE TO PIPE C5.51 864SB

    • tex 35**

{ t DATE: 02/16/94 NIGN ENERGY LIO BREAK Utilf 2 PAGE: 30 AUGNENTED INSERVICE INSPECTION PLAN CLA$3 2 SCNEDULED COMPONENTS INSPECTION INTERVAL, PLAN STATUS ,,PRESERVICE YEAR l FIRST SECCID TNIE l ASE l PERIS PERl!B PERIIS l SEC. XI l - ----- -*--- - --- - - - --- l SUIMARY EXAMINATION AREA CATGY ISE l - ---00TAGE------l INSTRUCTIONS NUMBER IDENTIFICATION ITEN No NETH l1 2 1 2 1 2 l "CALIBRATICII BLOCK" FtteuATER 6-PW 2-098 1303-2 TDLR VERIFICATicIl touteARY. X 157920 TCX 2 2403 35 CF2 UT 1-PIPE TO P!PE C5.51 864S8

    • TBM 35**

l l TDLR VERIFICATICII BOUNDARY. X 157940 TCX 2 2403 36 CF2 UT 1-l PIPE TO PIPE C5.51 86485

    • TBM 35**

i I 1 i l l l t l I I 1 l l l t

1 J SUPPLEMENTARY CONTAINMENT SPRAY AND RESIDUAL BEAT RESEOVAL PIPING WELDS 1 l i The containment spray (CT) system piping on the discharge side of the four CT pumps contains 78 welds (15-25 each loop) that are 10-inch NPS Schedule 40 with a waB thickness d 0.365 inch. Furthermore, the residual heat Immoval(RHR) system piping on the dischange side of RHR pumps 1 1 } and 2 contains a total of 166 welds on 8-inch and 10-inch NPS Schedule 40 piping with wall thicknesses of 0.322 inch and 0.365 inch, respectively. I Resulting from SSER-26. the augmented inservice inspection shall include a volumetric examination (i.e., ultrasonic examination) on 7.5 percent of the aforementioned welds. Dese j examinations shall be distributed such that each weld or poruon thereof is namined once during j each 10-year interval. i 4 Examination procedures and personnel shall be in accordance with the rules of ASME Section XI. 1 No special reports are required for this activity. Records of the naminations shall be maintained ) with the applicable work ottier.

l Results of these naminations shall be evaluated against the acceptance criteria provided in ASME j

Section XI. IWC-3000. 1 Summary Discussion a. Governing Document - SSER-26. l b. Eram Items and Boundaries - 7.5 NM of the welds discussed above. NDE Method and Schedule - Ultrasonic namination once per 10 yea? interval. We specific c. j schedule by refueling outage is attached. d. Acceptance Criteria - ASME Section XI. IWC-3000. j e. Special Reports - None. I 1 4 i (1)

~. l I ( DATE: 02/16/96 RESIDUAL NEAT REMOVAL /CONTAINNENT SPRAY UNIT 2 PAGE: 1 AUSENTED INSERVIE INSPECTION PLAN CLASS 2 SCMDULED Cap 0NENTS INSPECTION INTERVAL, PLAN STATUS _PRESERVICE YEAR i l FIRST SECCW TNIRD l ASE l PERIS PERIG) PElle l SEC. XI l.- ---*---- - - ---- - ---- ------ l SubstARY EXAMINATION AREA CATGT WE l-0UTAGE-* -l INSTRUCTIONS NUMBER IDENTIFICATION ITEN NO NETN l1 2 1 2 1 2 l " CALIBRATION BLOCK" RESIDUAL NEAT REMOVAL 10 RN 2 061 601R 2 l 170700 TCX 2 2520-35 C F-1 UT 1X REDUCER TO P!PE C5.11 75758 " tex-10" 170750 TCX-2 2520 35L C F-1 UT 1X LrelG. SEAM C5.12 78738 "TSM 10" 170000 TCK 2 2520-36 CF1 UT 1X P!PE TO VALVE C5.11 78738 "TSX 10" 170050 TCM 2-2520-3&L CF1 UT 1X l LONG. SEAN C5.12 nrSs i "T3X 10" 170900 TCM 2 2520 37 C F-1 UT 1X VALVE 70 PIPE C5.11 nne

    • tex 10**

i l i l 170950 TCX 2 2520-37L CF1 UT 1X t 4 l LONG. SEAM C5.12 nne "TRM 10" RESIDUAL HEAT RENDVAL 8 RM 2 064 601R 2 170000 TCX 2 2521 48 CF1 UT 1-X l PIPE TO FLANGE C5.11 t alte " TSM 7**

DATE: 02/16/94 RESIDUAL MAT REMOVAL /CONTAllSENT SPRAT UNIT 2 PAGE: 2 ] AUCNENTD INSERVICE INSPECTION PLAN CLASS 2 SCNEDULD COMPONENTS INSPECTION INTERVAL, PLAN STATU8 .PRESERVICE YEAR l FIRST MCOW TNIRD l ASIE l PER100 PERIG) PERIG) l MC.XI l -- - --- - -- -- - ---- ------ l SumeARY EXAMINAT10N AREA' CATGY NDE l-


0UTAGE--

---l INSTRUCTIONS MUNGER IDENTIFICATION ITEM NO MTN l1 2 1 2 1 2 l

    • CALIBRAT10N BLOCK **

RESIDUAL MAT RElWAL 8-RM 2 064 601R 2 178050 TCX 2 2521 48L CF1 UT 1-X LONG. SEAM C5.12 78188

    • TBX 7'*

l X j 978100 TCX 2-2521 49 C-F 1 UT 1-FLANGE 70 PIPE C5.11 7B198

    • TRX ?"*

i 1 178150 TCX 2 2521 49L C F-1 UT 1-I LONG. SEAM C5.12 78188 " TEX 7" 178200 TCX 2 2521 50 CF1 UT 1-X PIPE 70 EL80W C5.11 78188

    • TBM ?'*

i i X 178250 TCX 2 2521 50L C F-1 UT 1-LONG. SEAM C5.12 78188 " TEX 7" 178300 TCX 2 2521 51 CF1 UT 1-X ELBOW TO P!PE C5.11 78188

    • TEX 7" l

l 178350 TCX 2 2521 51L CF1 UT 1-X LONG. SEAN C5.12 78138

    • T8X-7**

~. DATE: 02/16/96 - RESIDUAL NEAT REMOWAL/CONTAllsENT SPRAT UNIT 2 PAGE: 3 AUSENTED INSERVICE INSPECT 10It PLAN CLASS 2 SCIEDULED COMPONENTS INSPECT 10ll INTERVAL, PLAN STATUS _PRESERVICE TEAR l FIRST SEccle TNIRD l AsIE l PERIOD PERIOD PERIOD l SEC. XI l - -**--* - --------- -- --- ---- l SupetART EXAMINATION AREA CATGT IDE l------0UTAGE------l INSTRUCT 10Ils NUNGER IDENTIFICATION ITEM 110 METN l1 2 1 2 1 2 l "CALIBRATICII BLOCK" RESIDUAL IIEAT REMOWAL 10-RN 2 026-6012 2 185100 TCX 2 531 6 CF1 UT 1X PIPE TO EL30W C5.11 O l M i "TBK 10" l 1 1~.3150 TCX-2 2531 4L C-F 1 UT 1M LONG. SEAM C5.12 79958 "TBM 10" 12200 TCX 2 2531-5 C-F 1 UT 1X ELBOW TO PIPE C5.11 79998 "TtX 10" 1 1 i l 185300 TCX 2 2531 6 CF1 UT 1X PIPE TO FLANGE C5.11 80058 "TBM 10" 1 l RESIDUAL llEAT RBIOVAL 8 RN 2-027 601R 2 1 j 190100 TCX 2 2532 36 C F-1 UT 1-X PIPE TO EL30W C5.11 797S8 i "TBN 7" 1 190150 TCM 2 2532 36L CF1 UT 1-X LCIIG. SEAM C5.12 79758 "TBM7" 190200 TCM 2 2532 37 CF1 UT 1-X ELBOW TO PIPE C5.11 79788 "TBM 7"

DATE: 02/16/94 RESIDUAL IIEAT REMOVAL /CONTAllNENT SPRAY UNIT 2 PAGE: 4 AutBIENTED INSERV!M INSPECTION PLAN I CLASS 2 SCNEDULED COMPCNENTS INSPECTION INTERVAL. PLAN STATUS ,PRESERVICE YFAR l FIRST SEcoliD TNIRD l ASIE l PEtttB PEttte PEttts l SEC. XI l - - l SUISIARY EXAMINATION AREA CATGY ICE l-- - 0UTAGE- --l INSTRUCT 10NS BRAISER IDENTIFICATION ITEM 110 METH l1 2 1 2 1 2 l " CALIBRATION BLOCu** RESIDUAL llEAT REMOVAL 8-RN-2 027 601R-2 -X 190250 Tcx 2 2532 37L cF1 UT 1-LossG. SEAM C5.12 79738 "TBx 7'* X 190300 Tcx 2-2532 38 cF1 UT 1-PIPE TO EL90W C5.11 79788 " TBX 7'* 190350 TCx-2 2532-38L cF1 UT 1-X l LONG. SEAM C5.12 j 79788 "TBx 7** 190400 TCX 2 2532 39 cF1 UT 1-X EL90W 70 PIPE C5.11 l 79888 l

    • TBM 7**

l x ) 190450 Tcx 2-2532 39L c F-1 UT 1-LosiG. SEAM C5.12 79888 "TBM 7'* l CONTAfMMENT SPRAY 10 cT-2 011 301R-2 i l 203800 TCX 2 2539-2 c F-1 UT 1-x l l ELBOW TO PIPE C5.11 n6Ss l

    • Tex 10**

l l 203850 Tcx 2 2539 2L cF1 UT 1-x t LolIG. SEAM c5.12 77685 l " Tax 10** i l

J J i DATE: 02/16/96-RESIDUAL NEAT RENWAL/CONTAllNENT SPRAY UMlf 2 PACE: 5 AUGIENTED INSERVICE INSPECTION PLAN CLASS 2 SCNEDULED CCBIPONENTS l d [ INSPECTION INTERVAL,, PLAN STATUS ,PRESERVICE YEAR l FIRST SECOND THIRD l i ASNE l PERIOD PERIOD. PERIOD l l SEC. XI l-**--**-- **-=----**-*l l SupewtY EXAMINA? ION AREA CATOY MDE l-- 0UTAGE-- --l INSTRUCTIONS 1 NuNsER IDENTIFICAT!0N ITEN NO lETH l1 2 1'2 1 2 l "CALIBRAT!0N BLOCK" toMTAllsENT SPRAY 10 CT.2 011 301R 2 2 203900 TCX 2 2539 3 C*F.1 UT 1-X PIPE TO ELBOU C5.11 i n6SB i i " Tax 10" l l i 5 203950 TCX 2 2539-3L CF1 UT 1-X ] LONG. SEAN C5.12 ) n6Ss " tex 10" 4 1 1 206000 TCX 2 2539-6 Cr1 UT 1-X l ELSOW TO PIPE C5.11 nats "T8X 10" l 206050 TCX 2 2539 6L CF1 UT 1-X LONG. SEAN C5.12 i n6Ss "TtX 10" 4 i 1 l 206900 TCX 2 2539-13 CF1 UT 1-X j VALVE TO PIPE C5.11 ~ nne "T3X 10" i il 1 j 206950 TCX 2 2539 13L F1 UT 1-X l LONG. SEAN C5.12 nm j "TBX 10" i i 205000 TCX 2 2539 16 CF1 UT 1-X j P!PE TO ELh0W C5.11 nm j "TBM 10" ) ) i 9 i a

t DATE: 02/16/94 RESIDUAL NEAT REMOVAL / CONTAINMENT SPRAT UNIT 2 PAGE: 6 l AUGMENTED INSERVICE INSPECTION PLAN l CLASS 2 SCHEDULED COMPONENTS l \\ l INSPECTION INTERVAL, PLAN STATUS ,,PRESERV!CE YEAR l FIRST SECOND THIRD l ASME l PERIOD PERIOD PERIOD l SEC. XI l - -- l

SUMMARY

EXAMINATION AREA CATGY NDE l- -0UTAGE --l INSTRUCTIONS NUMBER IDENTIFICATION ITEM No METH l1 2 1 2 1 2 l

    • CALIBRAT10N BLOCK'*

CONTAINMENT SPRAY 10 CT 2-011 301R 2 205050 TCX 2 2539 14L C F-1 UT 1-E LONG. SEAM C5.12 787SS

    • TBM 10**

X 205100 TCX 2 2539 15 CF1 UT 1-ELBOW TO PIPE C5.11 78758

    • T8X 10**

) 205150 TCX 2 2539-15L CF1 UT 1-X LONG. SEAM C5.12 ra7S:

    • TBX 10**

l l l l l l 1 l i l r 1 l t.

-.~ lp seg AIST 2RO - o f l Pt 2"6 3 REACTOR VESSEL HEAD AND INTERNALS LIFTING DEVICES l l l ANSI N14.6-1978 provides detailed :quirements for the design, fabrication, testing, maintenance, and quality assurai..c of special lifting devices at nuclear power stations. To address the control of heavy loads and to ensure against and mitigate the consequences of postulated accidental load drops, the Nuclear Regulatory Commission (NRC) issued NUREG 0612. Westinghouse Electric Corporation conducted an evaluation and documented the results under WCAP-10156, Rev. I to determine the acceptability of the reactor vessel head and internals lifting devices to meet the requirements of NUREG 0612. As a result of this effort, recommendations were made to perform periodic non-destructive surface examinations on prescribed critical welds and/or parts once every ten years as part of an inservice inspection outage. The above inspection methodology is endorsed via TXX-4226. ANSI N14.6 defines the acceptance criteria as the requirements of ASME Section III, Division 1 paragraphs NF-5350 and NF-5340. Furthermore, inspections utilizing liquid penetrant or magnetic particle examination shall be performed by written procedures and by personnel, both quallfled in accordance with the rules in ASME Section V. Articles 1,6. 7,24, and 25. No special reports are required for this activity. Records of the examinations shall be maintained with the applicable work order. Summary Discusston a. Governing Document - ANSI N14.6-1978, NUREG 0612 and TXX-4226. b. Exam Items and Boundaries - Reactor vessel head and internal lifting rigs' critical welds and/or parts as described in the attachments (Ref. WCAP-10156. Rev.1: Tables A-1 through A-l 4). D c. NDE Method and Schedule - Liquid penetrant and/or magnetic particle examination shall be performed once every ten years. The exam should be conducted during the end ofinterval,10 year ISI outage. d. Acceptance Criteria - Liquid penetrant and magnetic particle acceptance standards shall be as indicated in paragraphs NF-5350 and NF-5340 of the ASME Boiler and Pressure Vessel Code. Section III, Division 1. e. Special Reports - None. (1)

l REACTOR VESSEL IMAD LIFT RIG, CRTI1 CAL FTI255 IJBT PER ANSIN14.61978 Item W Description Material Non-destructive Examination Method 1 Lifting Block ASTM A350 Magnetic GRIF Particle 2 Img ASTM A516 Magnetic Grade 70 Particle 3,6 Clevis Pin ASTM A434 Magnetic AISI 4340 Particle Steel Class BD 4,10 Clevis AS"IM A668 Magnetic I Forging and Particle Class L AISI 4340 5.9 Lifting Leg ASTM A434 Magnetic Class BC Particle AISI 4340 11 Clevis Pin ASTM A564 Magnetic Doad sensing) Type XM12 Particle 12 Side Plates ASTM 533 None Type B Class 1 13 Removable Pin ASTM A564 Liquid 'lype 630 Penetrant W ee Page 4 S l I (2) l l l l

i REACTOR VESSEL BEAD LIFT RIG. CRTI1 CAL TNadB IJST OF WELDS PER ANSIN14.61978 Non-destructive Examination item (*) Description Method i l 1,2 Lugs to Lifting Block Magnetic l (Full Penetration) Particle i 7,8 Spreader Arm Magnetic Lug to Spreader Ann Particle j (fillet) 1 W ee Page 4 S 1 ) i i i l l l i I i i I l l l 1 I I l J l (3) 1 l I I

CLEVIS PIN (LOAD SENSING) h ( REMOVABLEPIN @ @ SIDE PLATE LIPTING SLOCK @ s 'ua @ @ LIFTING LEG s / Clevis @ / / / @ CLEVISPIN ARM @ @ lug 3 Nm @ UFTING LEO g ~~" ~ ~ TYPICAL CRDM ~ l_ / 1" 19 4 h CLEVIS%. -) l @ CLEVISPIN i oco Reactor Vessel Head Lift Rig i (4)

i j j REACTOR VESSEL DrTERNALSIRT RIG CRITICAL TIEMS LIST t PER ANSI N14.6-1978 i { Item (*) Descriptien Material Nan h Examination Method 1 Lifting Block ASTM A350 Magnetic l GR IF 2 Particle i 2 Lifting Block ASTM A516 Magnetic Ing Grade 70 Particle j l 3.7 Clevis Pin ASTM A564 Liquid Grade 70 Penetrant i Precipitation i Hardening SST 4 Age treated O j 1150* F/4 HRS. Air cooled 4 l RC 28-31 i 4,6 Clevis ASTM A471 Magnetic i Class 3 Particle j Steel Forging ) 5 Sling Rod ASTM A434 Magnetic 1 Class BC Particle i AISI 4340 or (ASDI A588) 8.11 Spread Lug ASTM A516 None 2 Ieglug GR70 STL Plate Normalized i i 13 Mounting Block ASTM 350 III None Forging Steel I 12 Ieg Channels ASTM A36 CS, HR None k I l (a) See Page 8 i 1 l l q (5) 4

1 n l REACTOR VESSILINTERNAIAIRT RIG CRITICALIl2MS LIST j PER ANSI N14.8-1978 l t Item (*) Description Material Norwiestrucuve Examinaban Method j d l 14.15 Imad Nuts ASTM A276 None Rod Housing 'Iype 304 SST, Hot Rolled, Condition A 3 i 16 Guide Sleeve ASTM A276 Liquid Type 304 SST, Penetrant i Hot Rolled. } Annealed i & Pickled, ConditionA t 1 j 17 Engaging Screw ASTM A564 Liquid Type 630, Penetrant 17-4 pH Steel e 1100*F i for 4 hours 4 k l (*) See Page 8 4 k i i i 1 i 1 i i I l i I 1 ) (6)

REACTOR VESSEL Uf!ERNALS IRT RIG CRIT 1CALITEMSIJST OF WELDS PER ANSI N14.6-1978 Item (a) Descripuon Non-destructive Exarnination Method i i l 1,2 Lugs to Lifting Block Magnetic (Full Penetration) Particle 8.9 Lug to Spw.ader Block Magnetic (Full Penetration) Particle 11.12 IAg Lug to Chan=1IAg Magnetic (fillet) Particle 12,13 Mounting Block to Magnetic Channel Leg Particle (fillet) W ee Page 8 S i i ) i i i 4 4 i i

i i LIFTING 8 LOCK @ / l N LUG @ i 4 @ CLEVISPIN ^f q = @ CLEVIS % [ P o i T3 b< ~ SLING ROD @ c j ,f /) [ CLEVIS @ \\ h ARMh y/ yBwcx @ s @r ** @ j [ (7'[ j f'g a ^" CLEVISPIN @ \\ EG LUG @ L , \\ f y CHANNEL h s 5 i /N L ,a L i =,, r f4 [ I 2 h LOAD NLIT l @ MOUNTING BLOCK ) h ROD HOUSING I h GUIDESLEEVE @ ENGAGING SCREW i i Reactor Vessel Internals Lift Rig ) I ) (8)

i I a i

SUMMARY

OF REVISIONS 1 ei Ms IEY. Summary Original issue 0 4 f i E 4 r 1 } 4 4 9 k 1 i e 4 I 4 i i i p i i l N I e n 1 e J 1 3 9 a l ] 1 i 4 4 (1) 2 i i

ICR AISI-2RO-03 ( Page 5 of 5 INDEX AISI PLAN INTERIM CHANGE REQUEST (ICRs) ICR No. AFFECTED PAGES CHANGE AISI-2RO-01 Section 6 Schedule lifting rig exams Page1 at the 10 year ISI outage. AISI-2RO-02 Section 3 Adopted wear method and Page 1 and 2 acceptance criteria from WCAP 12866. Documented wear found during 2RF01. AISI-2RO-03 Section 4 Removed inaccessable exam pages 2,4 and 7 items from table. O (1) L

ENCLOSURE 2 TO TXX 95002 [FSAR Pages 1A(N) 76 and 1A(N)-78] i i i I i i i i l

r +=- CPSES/FSAR M 46 Reaulatorv Guide 1.150 46 Ultrasonic Testing of Reactor Vessel Welds During Preservice and Inservice Examinations I 46 Discussion I l 46 The CPSES position on Revision 1 (2/83) of this guide is as follows, 46 Preservice Inspection i 46 A partial R.G. 1.150 inspection was performed on Units 1 and 2 reactor vessels in accordance with Reference (21]. 46 Inservice Inspection 46 CPSES complies with revision 1 of this regulatory guide. 1 91 Reaulatory Guide 1.151 Station Blackout i Discussion RefertoAppendix1A(B) l Amendment 91 1A(N)-76 April 15, 1994

CPSES/FSAR 11. " Environmental Qualification of Westinghouse Class IE Equipment," WCAP-8587, October 1975. I 12. DELETED + l 13. DELETED 14. Letter NS-CE-784, dated September 22, 1975, C. Eicheldinger (Westinghouse) to the Secretary of-the Nuclear Regulatory Commission. i t l 8 15. Letter NS-CE-1157 dated August 13, 1976, C. Eiche1dinger (Westinghouse) to the Secretary of the Nuclear Regulatory Commission. l 8 16. Butterworth, G. and Miller, R. B., " Methodology for Qualifying Westinghouse WRD Supplied NSSS Safety-Related Electrical Equipment," WCAP-8587, Revision 2, February 1979. 8 17. " Equipment Qualification Data Packages," WCAP-8587, Supplement 1, November, 1978. 8 18. Jarecki, S. J., " General Method of Developing Multifrequency Biaxial Test Inputs for Bistables," WCAP-8624 (Proprietary), September 1975 and WCAP-8695 (Non-Proprietary), August 1975. I 8 19. Fisher and Struik, Guide to the Design Criteria of Bolted & Riveted Joints, John Wiley & Sons, 1974, p. 54. 8 20. Chesson, E. Jr. Faustino, N. L., Munse, W. H., Hiah Strenath j Bolts Sub.iected to Tension and Shear, Journal of the Structural l Division, Proceedings of the American Society of Civil Engineer, October 1965, pp. 155-180. 46 21. Letter TXX-3632, dated March 1, 1983, H. C. Schmidt to J. Youngblood, NRC Licensing Branch No.1. July 31, 1987 1A(N)-78

a I i i I l i l l l l ENCLOSURE 3 TO TXX 95002 l l I 1 1 t I J

eman + -~. --~- 4 M P i a O U k.[) 1 w ~ \\ i f \\ \\ Il \\ ll t '.T J[ .'l

  • /'

fsN'\\\\\\\\\\N.x'.\\N6N 0 s ' ' Y. ' ' / : /. '. e / t t-1 } i s s '~~~~'~ O g g 6 I 8 g 3 g t ,q l t_. e I 3 _q __-._,_s._.--.-.L '. _. __i. T _.__i _. _ _ _ _ _.. _ i i 5 .

  • _r_.

_J s t t ~- e i 1 4 J,r-3 'I i cf i i i i r _. i 1 i TA ~ 't5 I i t 8 i i 4 i I e i e i l fj s -) Q' g i. >/ ,r s. C '< s 1+l/ nu i [5gi 8P ILLtJSTRATIVE USE Ort.T O VES: WELDS 4.5.15.16.IT & 18 - T =5.38' WIN. DESCRIPT ICN: REACTOR VESSEL' TU ELECTRIC VESSEL MATERI AL-SA-533 CPSES UNIT 2 nozztE uinRiat s,os INSERVICE INSPECTION LOCATION ISOMETRIC icx-i-noo lREv.:- l os.oi_s4 g 5 #7am dr/#/L p /-py areRovat: u u n o.:.2.is, - <g_..._____ r n -a.. ...m ~, ,w,, ..e,. ._..~.,w- ,---,r- . =, - ..--.m.- m, a - ~, - - - - - - - - -


..--a

ou& LOOP 3 LOOP 4 sco22 L l lit t .;.g,

.g,

..r l en

  • 2.

~ i 20 - - 28 l ',"h s

r. --

n 2 x i LOOP 4 LOOP 3 g E gj'7 @$E 22* / B58* I N a l 9-4400 MN 'M I o. iso-I-4200 m 34 l l 2C2* LOOP I OU E 33s' / \\ s E!! =nt e I s h.4100 ~ 3 N g _3 8&2 { 2g 24 '38 'l

  • %.,g.stgo 83 le 293*

247' h" '"

  • 33 se i est i NO2ZLE 270*

NQllLE ItLU$feativE USE Oety NOTES:

  • REFERENCE FOR REMOTE TOOL EXAMINATION 3 DLdCRIPT ION: REACTOR VESSEL NOZZLES TlI CI C'TDI 1U LLL II\\I INNER RADIUS EXAMINATION ITEMS ARE IDENTIFIED j

BY THE CORRESPONDING NOZZLE TO SHELL WELD CPSES UNIT 2 NUMBER WI TH AN *lR* SUFFIX. INSERVICE INSPECTION LOCATION lS0 METRIC 4 OPPROVAL: Q%g [ggy f./-py T C X -l -1100A lREv.2 l 09-01-94 i c. n m 42.is i e m-m m -,+,-.cc- -e- ,<~,w> e - me

5 l j W R 8 o o o a .= s -N s i s si, a 3 u a os u 8 l o. I IE 45 l RE 4 as c c E E 5 o e = =8 l ea a is 13 9 n "l si E => 5 2:n 28 l 8:

9 A

) / g>. [ - - ~ ~

4W "

h a [ a: 7fr..W%W P h.\\ L lf' m. c = - m 'L. s,, w a- ~*-rwi w e r w,= g ) '-~'~ = Fg + g~ m g

.Li;ib, 3. ).

gs",'q;, - f --... Z __ = 3,7 _ x...... t, . w - --- = _ _. - .= = , ha 11~ r - +i u -==-- 4, H .=,s ~~ ~ ' * *1 ',,'C ' lT) ~~ ,;p3 - -- A c-o .m ._ f I' g * ' ,, Q ; 4 - Z c / TJ T = 7C ~0 5?5 d r. tcc l c i c _f. ..__.___s

g. _

~ -( g .~ s ( r U) l E A "8 E Ea 88 a gs c 2 af A A 55 ai a5 s -a s

a d

= u ~= =

== rc 1 m g a "s 5 ys as 8 P" a p i = 3 "E E p i 2 != 5 5= 8 = = a g8 8 g g 5 3 2 ~ = N O ettusikaltvt USE Ora v ooscaierion: ne.cror; vesset inicanits m RETRIC ,,,os, CPSES UNIT 2 INSERVICE INSPECT 10N LOCATION ISOMETRIC icx-I-1200 57'2 lREv. t l 11-03-94 jf84[% d 3-f4 APPROVAL: 7 e

9 E 3 W -4 m j 3 l E=m I --u n s s = a ga .M Y .9 Sc N e PW C M E O rh '3 5 d iii @2 e 5 c G55 M 19 5

  • E 5

a$ .E / / MA _,/^- _, - _ - 77 9 x n Inie ee keeeM,i .J:tIf El :

1 H

~ If3I: Ulf : Z 5 )),,);'

a q

_ _ _ii ..w,. p s m r espae sse.

- ))
))) :

I Z ~- CCCCCC '. ' . 'I 3:> { C,*t..str en r s I Dl:D., If:1 : E \\ m i, na 1 i Es u \\ \\ \\ T-25 88 S's s 8 ss sc at -n

== s = ms N En Om

  • m m

E am a 3 Wc Em

  • 2 P

m mm m YQ Y mE OC O n oE 3 9 2 =m Ey m m a Rd mo ,t t,3,,,,,,, gsg g POTES: DESCRIPTION: REACTOR VESSEL INTERNALS TU E ECTRIC CPSES UNIT 2 INSERVICE INSPECTION LOCATION ISOMETRIC APPROVAL: M//[ f/-l f Y TCX-t -12OO 2T'rlREv.I l 18-03-94 4

L54 E 1 E z. ou o r!M..f.M,3x. is.s ! N.N N 8 E I 'L si et 2. - i , e r gm j ,0 g g n.2 v 4 Z mo I O bJ. D 2 i ~"**c" w } j mz =_ r. i 7 ._; W I -- O uj 20 l I 1.O Oi i uJ 3 O O. 3-m a:r 8 1 y H o_ so 4 wo n l OO OO, ~ u 'sO g s,. " ' 'N O 0 0'O O 0 9 0 00 .o-. _,w .-. o-o-o-o-o-o-o_._ o. 0 0 0 5 h0 0 l ,, j 999 99 i ~ ' 0 <2 2 OO OO i 1 O O 'l l 'OO j / Oi o x s l

51. at 2

' stuu, m c i y l 2io-l o o o g d 1 i sc ,,,c ..ccw. - o o g i o., cu, .ssEuBLY j fl l O O so w i 5 I l O i i __. s _ o. _, O/ x to oi5c .w -..c x i w(Lo 2 y i 1 h, 4 I W'., _O.._._._._._'_._._._._.O_ i . _,,0 1 O O-E- IN

o. _.

,g I I s i o 'I 1 I g o _oioms y o x ' - _ oio m. E O M N w 4 s I ~PoM!d'" Y 5 2! 23o. moi a g a W E c ;' S % C -ii l .a

t I 1 L (54-- i r g z -N ou 9 i w a e HE o l cc & Bl~a -- a i m.s r - UZ o ze w:3 c .- stud MOLE 28 a: w @y UO e' ? >w a 7.@ E4 o wu a F-a_ mo o za i s 15 0 0 !' s. ro 5'O O O, O O OOOO a0 0 0 0 O O O" i' no o oo on _u. - t is - OOo \\ "* t O O Oa to -l

o. _.. _.._. _. 'O G- -O -&- O-O,3

- i a- , 0 0 0 O 0 0 0w l' 999 99 l uO O O O On-3 I On E ",g)O.s ...O t O,, s y a a: l 0000 t i i g w i l y stuo Matt 3 - pn. ' puo at u sfuo MOLE 2 - - STUD MOLE 1 M LJ Q co b = w s. g g 11.00' r = 5 '\\ / / A \\\\ v /. l A +i ,l\\ 4.0 2.7s= \\ E j i f i\\ A x o Li k \\\\ \\ \\ N 7 f l (5?.2n ~ s' m y X -- s, isess SitEL a s e. d E 0 9 % s

l I'.lljlji!J', !fl Ilf!l. -1ll,I,/\\ II!lli!!lIi> II-lj \\l/:lIlI!eI,lIil>ililIll l;lIittI i, 1 3& i i i'

i t i 1 tI!-

I-J- i< f,< 1 'I, = u r.. / \\ 2 = 2 - ~ l, - l ,a' l . i, 3 x + S 2 s. e T 7 'l I g f t 2 l I J T t U o. j u i; - l 'l r ~. <N D ~ N m ~ j\\ ~ / l r, s ~. = l \\ ~- 3 f 7}l& .5' f .7 9 .I 6 .t 9 g 2 1iI 5* C I:>[ 'q I O lI! s, = N = V 0 ',,. U E 1 X 7 1 N ~ 0 &I 1 0 .~.'I I s 2 l l I U

  • f rr W

5 6 T 5 rs A H r j..*.' Q S ,l E ,,.,, 'fl>=. J).1;- R e + i b s I I[, 3 o 2s&:_y Y 5- + U>=SW r 4B, w mw0 w@ *9 ow a. of S> M~ @ w. E R<myp .LdwufT O KO&wa; Cm aH<4. M k-j. L] uOZ 6 aw O52 ewy g~ * $azwe 2< w Mq a, J UQ,_Ww 'CZ.l N ~ ~ gw Z wg Uw ~2m0.wUs oz .Oz ~"o.3wHm u Ou >V_ f-wo &w> u _, 8-5 cD, CO, Q@os;; W= %M &.~*k> Qx.1 i $'_

l f

'J1'Ir ln ' < .,j -j ; I,l0,; J 'I 't] f,t, 1, ' i,, t:, + y.i f*i,,. i !!)i>e >1 . - i 'l 1l .i..-f; !,!\\ .-i. '.,l,l l[e i,)lf!:ij l'I/l /l)i1<,!, l

  • W

-9 w [ ~"~~-~~"'- I I i r fn .D G3 " 5& t sa 'E i ( N y / e 7 /-Gn'jQ = f 1 '__.3.... - -. - - - ~ bI b, 7 ., J e y ~ ( ', (P) } 6 3 = = .3,5 m 3

  • 3_

R I.~ .') *[ A, / \\ TO,- . 1;;;*

  • . g~ \\d/

$[ i' l 5 . E U f i Fgg ~ 8 t t tLLU$TRATIVE USE MY NOTES: INNER RADIUS EXAMINATION ITEMS ARE DESCRIPT ION: PRESSURIZER IDENTIFIED BY THE CORRESPONDING NOZZLE TO (TOP HEAD 12.0*/SA-533 SHELL WELD NUMBER WITH AN *lR* SUFFIX. (BOTTOM HEAD 12.55*/SA-533-p p C C S ' 'N I T d' v .) L_ U (SHELL) 4.O*/S A-533 (SUPPORT SKIRT)1.5*/SA-516 INSERVICE INSPECT 10N (BotIING) 1.875* DI A./16 i t* LENGTH 1 - l 09-01-94 TCX-1 -2 t OO lREv. APPROVAL: - M&w MYw [--/- f Y r w nnoos.nsu .m .mm-. -m. ~

e wa <.--m,- - m ____,r______-__--_____m_u_

_.m. .m... .._.-....m.~.. .....-..,~...u...~.....--..m...--~.._-._-. m m --.w. ..-m. _ma.. .,_m .,.4-m i l + e. --~~~~-----------:- --- - ' ~ - - 5 I i I .i uELD 2 EREF.2-It006 6 E ] s-iff and flNf R& TOR WM 94AtlW A T 8 % TING INSIM RADitf5 -.--~ m a 3-1 conf 5fDE s-St TO l-Sis la COLD $sCT t-Bir TO l-932 IS ,'8' -(Haes(L HE AD 10 8,67 / TUBES 4fi # ELD 2 2-t H0f510E 2-St 10 2-St6 2A \\ / ~ $2 ' t - t. 2-4. 3-5 4 4-4 COLDSIDE 2-817 TO 2-812 28 / , T 6g)# ' 3 3-t - HOTSIDE 3 81 IO 3-81% 3a g. j- /[. COLD 510E 3-61T 10 3-832 ' 38 4 4-e NOT5sOE 4 -85 TO 4-B t6 4A / N 'g ~b s. .f,. cotosiDE 4-8t7 TO 4-832 48 N /. -sa tiNc . 2' N022t( INSIDE - . RADIUS f ' ttlusfaatavE USE O R Y NOTES: DESCRIPT ION: STEAM GENERATORS 1,2,3 & 4 I (IUBESIDO S.3*/S A-508 ~ 01EADSIDD 5.3*/SA-216. CPSES UNIT :2-e 0 a inc n.8Ts oiA. m. n m,c m lNSERVICE INSPECTION LOCATION.lS0 METRIC I - l 09-01-94. APPROVAL: KS qA fy 74 fy TCX-t-3tOO lREv. J, ic m mm.isi 4 m .e.. e--c-m .-r-rw m =--s e--. a m .e - + .<..m e s ..i.*+ m um a

~ - i V A r3 PUMP STEAM I GENERATOR gy,. ). S" 1 .ar6. a, T di.. s,'!l6s (. a, ,k 2,,s.5f62 ' ' ' ' ' ^ ' 4 g, v.s in. ' I,'7T6, ,2 's < 13 t 61-y REACTOR VESSEL i i illusTRaf.vE tfA 0*E t NOTES: DESCRIPT ION: REACTOR COOLANT LOOP I T/SCH: 831-)2.48*.(29*)2.33*.127.5*12.21' CPSES UNIT 2 s A-3si-Cr8 A ERP RC-2-520-001 INSERVICE INSPECTION LOCAT ION ' ISOMETRIC t FLOW: M2-0250 TC X-1 -4100 lREv.I l 09-01-94 Mg [gg f.//y APPROVAL: 1 C x i-4 ti u t t.t S t e w ,w ~ --w -w- --n x ,--r,,-

  • amm 8" mum t

h. I -.. - - ~ 5 REF.4-4tOO p' / REF.B*4t04 g" 2 3

Cin 4-.

DCit. gg 5 6 t Y \\y 2-8702a H) Hi W / 4 na, \\,64

m... m., m..

HJ 9 - H2 EM OO T -e n -( 4 tk H3 : RW.'-001-434-{ 415 2 8F01a to H4 : FM 2 001- @%-C4fP H$ 3 GH 2 QQl-407-(4R H6 : PH-2 COf-402-(4 tR REF. 2-2500 H7 : RH-2 -00 4 - 4M4 4 tR M8 s WH 2 001 408 C 49 H9 FH-2 -001 - 405-C a th suusinativt ust ony DESCRIP T ION: REACTOR COOLANT /RHR NOTES: T/SCH: (12*H.125*/140 - CPSES UNIT 2 BRP: RC-2-RB-02I.RH-2-RB-OOI.RH-2-RB-OO3 INSERVICE. INSPECT 10N ~ LOCATION ISOMETRIC-ggg ggg 7./ fr FLOW: M2-0250.M2-0260 TC X-t -4101 lREv. t l 09-01-94 GPPROVAL: l 't"On 's' 5 m m u i+m w --~,+n + - -. - - - - - ~ - r m

m...

muum ~ i ~ ~~ ~ ~~" l i j 5 n A 1 2-III " '~ gg. 7-J^ ~ 'Wa lW a %*

g. gfr) gg.,

81ED TEE Y 83 q s-4103 ?< *Hu h f6 bG4 7, DCH3 r y

  • H18 : '.at S I P3-ess t a n NJ = $ 4 2 g yg 4g 4 4,9 H3 I $8 t it-40].(4g -

H4 e 54 2-4 ?9-404.cara -- l ILL415TRaityE 415E M y NOTES: DESCRIPT ION: SAFETY INJECTION / REACTOR COOLAHi' TU ELECTRIC T /SCH: I IO'11.00*/140 CPSES UNIT 2 BRP: RC-2-RB-032. 51-2-RB-068 INSERVICE INSPECTION LOCAT10N ISOMETRIC gg4., g2 y FLOW: M2-0250. u2-0262 TCx-I-4 to2 lREV. 3 l 09-03 94 APPROV AL: ' - -T D 14102 5.ts t v

===.s-w e 4

m. -

w 4 ,._a 4- ,- u me m m m

i V ? 4 .h T t' HU.3.aso2 t3 j 6 J. 82 . et 7 2-089 6 s 10 - 9 d( I J(tN u )c HG. 3C H*l ,,3 h,H4 H: 6 5 CF2-$455tst-05 14f8CD 4 3 '2 58 2-063" 35 2 16 2-84tsa -mu A.* c'wl v.'(in 8 R: $F2-099 All (4t5 H) s $1 g%.Q89-40)T 41h g y na, st+039 406-C4a 2-88t8a. . frEF. 2-2%6a H5 5 4 089-405 -C 4 :8 N6 s $t-2489 404-C414. 3 - REF. 2-2513 tuusinaisvE USE ONLY NOTES: DESCRIPTION: SAFETY. INJECTlON U. L RIC-T /SCH: 16*).719*/I60.(2*1.344*/160 .CPSES UNIT :2 i BRP: SI-2-RB-045.SI-2-RB-066 INSERVICE' INSPECT 10N ? - LOCATION ISOMETRIC APPROVAL ' [ k e ys (( [-/fy. FLOW: M2-0262.M2-0263 TCx -I-4103 'lREv.3-l 09-01-94 icnnowss _ _ '_T

m I 4' .s** 2-8949a i k.' 6* 2* RED 4 . e I REF.1-4tu8 REF. t-elot Dt9CD h HI : L4. 14d' 4' 0 0 4 86 A' s $ 9 - 2 ' 143 -4U3 ~C4 LI' H) : RC-2 iNB'4*M C4iS I SLLUSTRATIVE USE ONLT ] NOTES: DESCRIPT ION: SAFETY INJECTION / REACTOR COOLANT g{ Tescu: wais eiso BRP: RC-2-RB-O t 9. 51 RB-061 INSERVICE INSPECTIGN LOCATION ISOMETRIC APPROVAL: (([Myj gh [./.y FLOW: u2-0250.u2-0263 TC x-t -4104 lREv. t l 09-01-94 T C x 141041. i s i w w.

i 'p kM [ Y i 2-estsa

  • c.

/' s 3 2 -4 Y ntr. s.. ion ni cs:.. u 4., titUSTRAilvE USE ONLT NOTES: DESCRIPTION: CS/RC ALTERNATE CHARGING T/SCH: (3*lA 38*/160 CPSES UNIT 2: BRP: RC-2-RB-017,C5-2-RB-029 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: y?Myy Mg ffp Flow: M2-0250. u2-0253 TCX 4105 lREV. 1 l 09-01-94 _muiosusi i ~,

r [ t D~ h .t i

l

~ -, .i 't I k S'.%, ~,Q 'S I ettust u tavt ust ONLY N01 ES: DESCRIPT ION: REACTOR COOLANT RTD RETURN l T/SCH: 83*l.438*/160 CPSES UNIT 2= BRP: RC-2-RB-029 INSERVICE INSPECTION ~ LOCAT10N-ISOMETRIC 'l APPROvt L: g2 faryi M f-/ # FLOW: u2-0250 TC X-1 -4106 lREv.1 l 09-01-94 T C r 1410n 1.15 4 l .l

r new. ~~~ +: .h s/ , 4 6 y 2si-esoon 4 M Mtb g HIS 1f l2 h a 'CHt4 II " 34 . t M4 256 -8810a ,gg3 i. 4E-0924 .IYa-St-2-025 -. y 9 0 ,- y iyf mEo str.i-4tooi i 3 ,g t 2 2i ,Ho IREF.8-4600

  • 8 3 nl'// RED i

ut H-p-2 l t 04c 3 *4 ' 1 H.I t M SI J bH 049 2431 - H1: H '.8 ? &D n44 ve f 448 3 69 ',3 / 141 H19 sH I HS

  • H "j4 -2 RE 04'J sul 4 g4 He H-Si 'J-FB -041 NJ-l -

8 M7 : H-St RB -04 4 16 5-6 ' HI ' N 8 " 5' I

  • Od *

"#~ 10 ft) : H St -2 PB 043112 6 ' Hto i H St O PB 64 s TOS-t uit : O ns / RR u4 e 7% e is stll t St ',S l 541 u t g tset t gg ut} s H,4 2 W 04t Uni i . te 4 : H 2 FB 041 M9 1 Ht5 g H-$1 2 GB 043-710-l' Hl6 s M-51 2 H6 043 716 1 6ttOSTRalivE USE ONLY NOTES: DESCRIPTION: SAFETY INJECTION / REACTOR COOLANT TU ELECTRIC T/SCH: 13*).4 38*/160. (1.5*l.28 t*/ t 60 CPSES UNIT BRP: RC-2-RB-Ol8,SI-2-RB-048.51-2-RB-049 INSERVICE INSPECT 10N LOCAT10N' ISOMETRIC 1o APPROVAL: $3hf Mg //[y FLOW: M2-0250. M2-0261 TC x-1-4107 l REY.2 l 09-01-94 ,J icmiows: 'I 2 ____.__c_,4. w-e m 2 m mu

I amm. \\D i e L 1 g 7.h* RED INS. 6"= 2* RE O .-\\ batr,e-4804

y r cPLC.

tl 32 13 9 (P2-$t$5MR-02

cup,- g-se-2-059 t+b

} REF. 2-2568 He f j 41 2 /$ - r (PLC 3 , - 2=. Ft RED. E ' w.st,%it 06J 701 1 6i i g;, tr p,., a s,t 2 tie (A t f02 3 ,,3, g 3 7.wg %. M i - H4 3 N'SIYUM H; g H-$4*2'pg'Mi IQ6 3 EO NI' W g H gg.7 L .,,, a si +ne-e t -iot-1 gtgu$tpattvE USE OR Y NOTES: DESCRIPTION: SAFETY INJECTION r TU ELECTRIC I T /SCH: 12").344v1GO CPSES UNIT 2: 1 BRP: S t RB-0 39. S t RG-os ' INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: M [4W tcx-i-4ios IREv.2 l 09-01-94 F TflX I4108-' I SI -- -'- ~ ~ ~~~~~ ~ ~ _,,w- .en ws P-e"**" _ - -_-. ~. - A d ,w.a=,<w e ru r-r,-- r-ww=> u. m.-a--a w --+-v-w-v invvv-+ wwrw -r-- w-1 w +r -w -=*e+w-

l . - = = =. - . i T ~ " ~ ~ ~ ~ ~ ~ 6 L I i i REF. f g -4100 l ~ .m f s-f s/ 2-RC-2-Ot5 ' a e' i l Hi. Tu s* RED INS ~. 6 nO ' 80 l 1 5 n. 2RC-80$fa gy 'g 9 .,et i H nt. 2 t-e,,gt. n ea 3 M2 : H-RC -2+B-02 F - 702 - 8 I H3 a h-RC-2 08 G2P+TO3.t 4 g g4 H4 : H-RC-248-C27 ?O4 6 "I Hs a n-RC-2+B 027-MS t j 13 HIQ gg g g.p(,g pg.gy g, yg, g e Hi a M RC-2 +B 02T-707-1 r 2seC-005sa He a M EC-2 RB-027 -70F -f M M RC-2 HB O?f 750 t Ht(8 : H RC 2 6tB-0?$ Ill i .,] ILitJST8tATIVE USE 084 Y 'a NOTES: DESCRIPT ION: REACTOR COOLANT-T/SCH: (2*).34 4*/ I60 ' CPSES UNIT 2-BRP: RC-2-RB-027 . INSERVICE INSPECT.ON - I 4 . LOCAT10N ISOMETRIC-APPROVAL: %hg 4My % /.fy FLOW: M2-0250 TC X-t-4109 lREv. l 09-01-94 1 T C x 141091.151 a < ~ . -,,.,. - = - - --, ,,2 <%-r--.--,..,...miw c-v,.< ~ -. - ,.c.e .....,.,--,.-,,e ~w ,w-+ ~..,s +...ri -..,.w. ..-v-,.w

L i. h 4 [ I i, H5 t3 44 30 44 f 1 M$ 2*u tYa* RED g ><15 i l 16 ) [ 'Ya-C%-2-248 5 2-CS-2-103, 9 H; / 2CS-6350s ' e to ' g; '.b.- &'\\. iti 23 g 5 a I 24 Il""0E 8 8 2CS-836f A l RC PUMP I n,,,,, I / Wi Hs r ? Wit c3is tot 1 i H3 : H f $ J.RB_Q3 }g. Ng.g H4 : H {5-2 f'B-03ra-702 1 H5 a t<-(5 J fi8 03ra 7031 t '6 H (5-2-Ir8-037a-704-9 tttustnainE USE ONLt i 1 C40TES: DESCRIPT ION: CS SEAL' INJECTION ~TU ELECTRIC T/SCH: (2*).344*/160,(I.5*).281*/160 CPSES UNIT 2 BRP: CS-2-RB-037A.CS-2-RB-0378 INSERVICE INSPECTION LOCAT10N 1SOMETRIC x APPROV AL: Mg4y3 gg f,(( FLOW: u2-0253 TCx-t -4 10 lREv. t l 09-01-94 ~3 1 C x 141101.151 ., _. ~.. _ _ _ _., -... _,.... . - _ __. _ _ -,. _... _ - - ~.. - -. -.... _. - - - - _. _ _.... _. _ -. _.. _.

. + PUMP / STEAM 2 iig [ d-GENERATOR 2 V 1 4 L, j ~~ a, .5!6s 5 -- e, ] d. I-256 3 3 3 s E 82 gy gg t 33 _ f REACTOR VESSEL J tLtusistainvE (M Ore.1 DESCRIPT ION: REACTOR COOLANT LOOP 2 NOTES: (31*12.48*.(2712.33*.(27.5*)2.21" T /SCH: CPSES-UNIT 2-sA-3si-CreA BRP: RC-2-520-001 INSERVICE INSPECT 10N LOCATION ISOMETRIC FLOW: M2-0250 TCx-I-4200 lREv. t l 09-01-94

  1. CP///ays gN1/-//)*

Tc iceci.isi d APPPOVAL: ~-,,---n-- we~-. --,--v+~a v.


ee r, wa v

-.a.- +aw -o e r ~ -, w -. + - ~ se ,, ~,, - - - - -, ~ v--'*, w --+,e e-n- < -+

o. _u -.m.- m .-m..m.m_. -.m.. m m- .m_.___m... 4 m. _m .m__._.. .m.- N ~ + t i S 50-51-2-880 ' to 8 i 2.. 7 1 i G 1 I = 8* - 'll, b l ~ 3 12 S~, Douts so-RC-2-037 g 2-89568 JcH4 IS )<M) H2 ' 2 .t3 e .r 1 so..- t,** soc i i t. siE F. He 50 2 too *Ja e 4in s t-4200 g u3 : St.2. Iso.4034atn y He 54 2 t80 404{4sa suusinatevt USE ONL V l NOTES: DESCRIPT ION: SAFETY INJECTION / REACTOR COOLANT T/SCH: (10'11.00*/140 CPSES UNIT 2 4 BRP: RC-2-RB-065. S t RB-075 INSERVICE INSPECT 10N {- LOCATION ISOMETRIC APPROVAL: M$p f/ff FLOW: M2-0250. M2-0262 TCx-1-4201 lREv.3 l 09-01-94 I f i 14,*( il L i '.. t / _._____________-______.___.._..____.__..__.,_____.____m_________.e .m e_,,_._m., e .w.. ,e ,m, .4.. ~, ...,,,_._4,..

w w + I b REF. <- 6 -$ 6 2-S2S 2-255S h' ~ 2-88lt9 / is QBC8 8*m6* RED --' se 10 t g, CP2-5155heR-06 3 e ^ q 15 g a6 si - 9 8-55-2-090 sp.r. - 21 2S 22 > 2-58-2-065 23 III"OOIE 2Hin g St-2-090-tiJ-04tS H2 r M-5t-2-RB -OtuC -701-4 H5 : S t 090-40 3 -C 4 ta H4 s $1-2-090-4044418 A " H5 : S i 2-090-4@ C 4 t* REF. TCA-2 2566 Il1USTRATeWE tJSE 084T NOTES: DESCR IPT ION: SAFETY INJECTION U. L I T/SCH: 48*l.906V l60.16*l.71T/160. t2*l.344v i60 CPSES UNIT: 2 j BRe: si-2-Re-oioC. SI-2-RB-026. SI-2-RB-028 ' INSERVICE INSPECT 10N LOCATION ISOMETRIC- $Mg gh f_/g FLOW: M2-0262.u2-0263 TC X-t -4202 lREv.4 l 09-01-94 APPROVAL: T C

  • 14 202-1.151

,y 3m. y-

emme W + ~. - - - - - - - - - -. ~ ~ - - -- l 5 9 tCE -5560f 6-RC-2W9 -+--- 6-St-2-tot 251-89058 REF. 2-2535 ,a g.gg.2-301 f' I J 2-884la A rg.,;, 2A a, 2 I, 2-.9 98 I y< Hs >(6H i s (P2-SIMMR-03 3 e 13 /y /nw eH f t : $1 g tol-4tli g 41.. HJ ; it 2 - tot -407-( 41a h3 ; St 2-tol-408-C41R M4 e 58-2-401 409 f 416 ILLUSTRaf tvt USE Oett NOTES: DESCRIPTION: SAFETY INJECTION / REACTOR COOLANT TU ELECTRIC T /SCH: 16*LT 19*/160. (2*).344*/160 CPSES UNIT 2 BRP: RC-2-RB-04 4. S l-2-RB-019. 5 4 RB-0148 INSERVICE INSPECT 10N LOCATION ISOMETRIC f8 gap M g f. /-/P FLOW: M2-0250, u2-0263 TCx-1-4203 lREv.3 l 09-01-94 APPROVAL: ic m20 5 3.is i r ___J l m.. m mm ..w. ~.-e, ~... + - -. - -,,, - -, - - - ..,_.---m.. , _ -, _ + _ _ _ _ _ _. _

h+ i t .t t i i i }......._,--..=:>. + + 1 1 ~ GLLUSTRativt tJ5E ONLV DESCRIPT ION: REACTOR COOLANT RTD RETURN NOTES: T/SCH: t 3*).4 38*/160 CPSES UNIT 2 1 I BRP: RC-2-RB-055-INSERVICE' INSPECTION -LOCATION ISOMETRIC apeRovat: gr.gg,g $6 yp rtow: u2-o2so TC x -i-4204 lREV. I l 09-01-94 i L ro mou.is.

r N => 4 m "?f q\\S

o,e t nm L,

y -su. /,/ [4'/- 6 Hi9 2-FE-0925 25 t-88006 g,,, 2-ew)Ce A u v v ~ ^ k f2 28 20 ^ 43 45 t%Tl0 g% 3 7 6 6% j f paa je D< H24 . 4 " ',8 25 "23 ^ ,,, 7 .,2 ,3 ,s ,6 % 2I a.14 " d9 / 30 nil[ 31 3 Hit /. 3 H3 N 's - 3 = lW* RED REF. ' tW-55-2-026 I-4200 I Ho 8 gi,,,qs.;.gg ,gg.ygg., ,p ,,. j. pg p ;y. gy 3, g 34 H2 H $! 248-u33-702-1 Ha r : ++ 08 -2 40 0 32-ro4 t 35 39 H3 ; H-$1-2-feB-0 33-TO4 1 Hl$ t H SI-2 R8 012-705 1 g, M4 e n f4 an 703 - 1 ut') t ** 5i.2,HH-632-FQ6 9 3*st%* RED , ne o n - ro r. : W 36 Hi m H t i -; + e..n - ros i H.u,. 5: H-5 r-2 Pe 032 F06 % .g, n.g,.;.P8-03 3 706-t H2t : )LH3 40f Mi : e*-5 t 'J +8 w 3 3 TOT-1 H2.?, H-S t-2 FB 034-F01-1 g )cua d H 5t '2 l'B 4t3? f08 -) H21 : H-512 RB 034 rO2 t d8 g 4 f REF. @ r H $6'2 RO".033 7U9 6 H24 : H $ t -2 RB 0 34 - 101-1 ' 3I t-4600 36 -HIQ H Sf-2 RB 033 TiG-t H25 : H $ t 2 48 -034 704 t Hli a H-$1-2 -RS -033-il t - 1 H26 : H $1 2-FS -034 TOf,- l Ht2 e H-S t EB '0 53 112-1 H27 s H 2-RP -034 105-t HI) H-$l-2 RB 433-713-1 H28 : H-S t RB -034 - 70 7 - 8 Ht4 : H St -248 032-T06 1 H29 : H-$ f RH -0 34-TO9 1 Hl$ t H-SI-2 +5-032 f02-t H30 g H $ 5-2-98 -Q 34 709 -1 ILLUSTRATIVE USE Cett NOTES: DESCRIPT ION: SAFETY INJECTION / REACTOR COOLANT TU ELECTRIC T /SCH: t 3*).4 38*/ t 60. 21.57.281*/160 CPSES UNIT 2 BRP: RC-2-RB-058.St-2-RB-032.St-2-RB-033. INSERVICE-INSPECT 10N SI-2-RB-034 LOCAT10N ISOMETRIC APPROVAL: %My; ggg f.-/- g FLOW: M2-0250, M2-0261 T C x 4205 lREv.2 l 09-08-94 V T C ' I C02.,?.151 s- ,---r,- r-n w x---- e -n

i N N s y. 4 l

.)

1 t i H2 s ut i 2-M-2 035 g 4

5. _ _ _ _ _ _ - 5 p

s ti l I' 4 3 [ 2RC-60578 6 2RC-00588 a J f HI 4 H M 2 f(t$-fd60 IQ1

  • I H2 : H-RC-2 RB-060-702-1 H5 i H-RC-2-RG-060-704-1 H4 t M HC 2 PB-t%0-705 8 r

ILLttSTRailvE USE ONLT DESCRIPT ION: REACTOR COOLANT i NOTES: T/SCH: 42*3.344*/160 'CPSES UNIT 2 BFP RC-2-RB-060 . INSERVICE INSPECT 10N-LOCATION ISOMETRIC APPROVAL: k8[dp. g f.[p FLOW: M2-0250 TC X-t -4206 - lREv. 1 l 09-01-94 ~ 7 T C < 142001.151 .,---.-.-....--w n

....._mm,w .m..._... ..& _ _ ~.-- _ s. m u. ..m.u---mm_...~.m ....m u ~ _.. -m...m m__ ....m~.. +.i j

  • " - ~ - ~

- - - - - - - + - - ~ ~ ~ - - - [ v 4 4 I 2** lVa* PED SY2-C5-2-249 g j \\ 3.4. g FLANGE I 2 m i R.C. ' ', ~O PUMP 2 I I - 2 (5 2-to$ 9 2 to 2CS-8%78 2C5-83508 xHz N m i i m i n.ts+neae. rosa HJ a H-CS-2fB Al2 705-1 j i i ILLUSTRailVE USE OttV otscaienOn: cs seu uc" " TU ELECTRIC

uOus, T/SCH: (21.344*/160. E l.5'L28 P/160 CPSES-UNIT 2

BRP: C5-2-RB-OO2 INSERVICE INSPECT 10N LOCATION ISOMETRIC FLOW: M2-0253 T C X-t -4207 lREv.1 l 01-94 M[p M, f,/.ff { APPROVAL: Tc u co n.is i y m -.m-m -. ~< c --. .m

-N ~s ~ - - - - ~ \\ UMP-P STEAM GENERATOR 33 )s, 3

9. e, _ \\'

v. .s.=, ) a, - q. 4 16 a 18Cl e REF. REF. ~ ~~ "g 3 t-4303 I-4304 ei J 21.s.o. - a, a 3 2r s.o. - egoe 2 REACTOR'

VESSEL-tLLUSTRAlivE USE Opti DESCRIPT ION: REACTOR COOLANT LOOP 3 NOTES:

T/SCH: 4 3 t*>2.48* (29*12.33*. (2 7.5*)2.21* CPSES UNIT 2 s A-3s i-cr 8* BRP RC-2-520-001 INSERVICE INSPECT 10N LOCATION ISOMETRIC RPPROV AL: q f_/h FLOW: M2-0250 T C x-t -4300 lREv. t l 09-08-94 i rc m 30 m.isi .e- -e +,, -. m,.,. =....

r.,..

i -w j + l 1 i i i i t 1 8 9 _ p*~y . io b ~ e -x

    • e.

2.., e u N -* S2 .0.. . r,Nf aco.Tet 1 2 S .i )CH2 E i 4 it 3 r a

2..,s-1 A.

'l 2 t = i

j. - -.- $

m i si.2-isi-4o2-c4m l a arr. t-4300 g $3 2-181-403 C416 [ l .h iu usTaattvE USE ONLY } DESCRIPT ION: SAFETY INJECTION / REACTOR COOLANT NOTES: T /SCH: 110*11.00*/140 .CPSES UNIT 2 sae: aC-2-ae-osa. si-2-as-ore INSERVICE INSPECTION. LOCATION ISOMETRIC FLOW: M2-0250. M2-0262 T C x-I-4 301 lREv.2 l 09-01-94 $ emf % f./-fd/ f. APPROVAL: ia moir.isi e T ~,.... _ _. _ -, _ -... ~, -..... -

= m + -- ~._._-.. ~ _ _ _. _. _ It r P ' 10 h g7 Hi?C H6?C stEF. l-430te N 8-56-2-091 m H5?C He?C REF. TCu 2-2566 J) I-8619C 2-50-2-067 -- 23 g HI, ' { 22 r a-20 H3 M2 CP2-$ sssamt-of y 5 EED INS j 4 83',f-8a6*AED t 14 ~ 6-58-2-330 Hi : H-S t 2 5t6-olOA-b 5,- $1 35 s H2 H-54-2-PB-010 A-D% i H3 ss-2-osi.40s-(4 n 2-88tSC M4 : SI 2-011-436-(4n le[ if i6 HS 512-038 407 C4th g 9, M6 : St-2-09t 409-( 4ip y H7 s $ 5 2-091 408 -{ 4 tt. 2'= F.* IIED tN$ ~' g tLLU511tativE (J5E My NOTES: DESCRIPTION: SAFETY INJECTION I T/SCH: 18*).906*/160.(6*).719*/160.(2*).344*/160 ~ CPSES UNil 2 BRP: S I-2-RB-Ol0 A. S I RB-013. S t RB-02I lNSERVICE INSPECTION LOCATION.lSOMETRIC APPROVAb pggj gq p.h FLOW: M2-0262.W2-0263 TCx-I-4302 lREv.2 l 09-01-94 / T r x t 43022. s i 4 ., ~ - s- ,%-. - _.. = v.e--w,--,,.,r-w', e e ,.m.,

M D + - - ~ r g., e e a og 2-8949c \\ Y

pgF, 10 H4)(

g2-2$$$ o' 2-884'S gg y V i y, H2,- 2-ss-2-sot 't i. b> '8 . t1 17 4 P2-sissim o4 2 a h- 2.em y i;ti. j ""X t-4300 RED tNS ~~ 'f REF. 1Cx-2-25Lo v/4 mn, a e ne 4.,5i.4r. H2 : 51-2-102 4u7-C4:4 H3 51 2 - 10? - 410-( 41R H4 5 8 2 102 46) f 419 sttuSTRaf svE USE OP4.Y DESCRIPT ION: SAFETY INJECTION / REACTOR COOLANT NOTES: T /SCH: 86*).71 T/160. (2*).344*/160 CPSES UNIT 2-sRe: Rc-2-Re-o4s. s i-2-RB-Ol48. S t RB-Ol8 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: [8//[q [gy f./.h FLOW: M2-0250.M2-0263 TCX-1-4303 lREV.4 l 09-01-94 T Cy l 43034.t S t 7 ) m. .u.. .m m m m u.- u r = w

w 2-LCV-0459 1 1 3-CS-2-235 / H H2) 2-L{W-0460-24 it2 t 8 1 _H?o g, H3

  • g*

1 1O r RED TEE gg Il e HI4 s 8 "5 2-8085 uw l 12 \\ g y REF.l*4300 'N

e. '-42m xHi6 H., m2.oS2..,4 4 4,,

', / . H* Rf 2 %2-409 ( 4 tt l.

(H($

1 f.1 4 In 2 i62 401 (41$ 4 >H4 Rt: 2 052 429-C 455 4 H5 : RC 2-052-4054 4IR sW, a 90 2-052-40* ratR Dcn,3 M 052 Hr, pc,2.n5y 4to.csiR z . 22 H4 s HC 2-OG2-406-C41R H) : EC 2-M2-407-C41k 2 21 H10 : RC 352-4f t-Cain HIl r RC -2 '152 425-(418 3 20 ' Q *, Hl.* s ut 2 Gt 4:6 Cats ull : HC 2 <>,? 4,5 C4:s H14 t RC 2-OS2-% %-(415 19 Ht5 RC OS2-418 -L =. ' MI6 s RC 2-OS2-420-C416 N17 : PC 2-052-425-C 4 'a Hit _ Htd a RC 2-052-421 C428 nt) s RC Z 4s52-422 (4l> pg uja6 ; M.] e,52 424 (4ty H.'I : RC 2 (152 449 (4154 ,A, H9 , M:2 s W-2 452-429-L41R gy H2 3 : C S-2-2 35-46T-C a l ft H24 3 C5 2 }5 -426-C 4110 16 t tLLJSTRailvE USE 084.v NOTES: DESCRIPTION: RC/CS LETDOWN TU ELECTRIC .i: T /SCH: (3*).438*/160 CPSES-UNIT 2 BRP: RC-2-RB-061.CS-2-RB-076 INSERVICE INSPECT 10N i LOCATION ISOMETRIC l APPROVAL: gge gg 7.//f FLOW: M2-0250.M2-0253 TC X-t -4304 lREV. 1 l 03-01-94 r

o _u_s.o m s,

.m.. ...m. m m - .m-- 4.w.2 - -++ r r -.e r-w we - =

l r 4 \\ i 4 $*4 g b i ettusinativE USE Otty NOTES: DESCRIPT ION: REACTOR COOLANT RTD RETURN T /SCH: 43').438*/160 CPSES UNIT 2 BRP: RC-2-RB-OS2 INSERVICE INSPECT 10N LOCATION ISOMETRIC ZMyj ggy f./ fy flows u2-0250 TC x-I-4 305 lREv.t l 09-01-94 APPROVAL: I C 'i 14 3051.15 5 -,-._,-,r.,, -n -- - - - - - -... -, ~.., - - - ~, ~, -, ,v.. . -~~- -- - ~,

F + ~ ~ ~ ~ ~ ~ ~ 4.geg-2@ 22 g# ' 2se esioc g,,, W bW6 g.f;-PC-1 H g; g 94. g,, R(F, 6 24 25 t-8M He ?(H21 26 g L 2-FE-0926 - A . 4 6[7 6nl m H.* 4 { H3 6 ?C HJS 27 9 ,m t y gg g n n . H.'s t n g n sti : H-St-2-k8-00a-Ful-l >cH2r yg 30 ',50 HJ H-$t 2-RB-008-702-1 29 3 H3 : H-St PB-OO6-704 6 Ht9 , 4 H4 : H-18 -2 +8 -008-706 - 1 to H5 t W-5 5 2-FB-008-707 9 y H6 : H-it-2-fW OO6 103-4 Mr H se -2 e s ooe ros-e 1[ HN we t H $t kB 008 (10- 1 33,, M9 : H-51 kB OO8-Ti? t HIO g H-St -246 -008-7 44 t Ht t : H 56 -2 +d-007 - 705 -1 I2 34 99 ' : ** ' e 2 FB OO T, Jn.' l V Hi 3 ts/2-51-2-02;. en 1 : H se 2 645 00f tus I Hl4 : H 51 2 +B OO F - (44 1 i ,,3 36 HIS : H-$t -2 PB-DOT-705-t wtg i H-se -2+B-ont 1001 H,. 4 His -l*/2 m )'/ RED H2g 48 HEI M St 2 PB-Out /07-1 g V /D U 2 I5 86 t7 G ^ - "'I H:p i H_ss.2 PB-00F. fog-t l'8 ^ ., b 59 g e+ti : H St 2-FB OQt-7634 ,,.., >> u 2 ve v a w,t a ,u, y di j's si, e : st t 2 Fit ano Its t x 36 j' gg, 3 H/, s H $642 FB 008 flJ l 20 i s-4300 H2 5 : H Sf-2+E 00 f - F t 3-1 H.'4 1 H Si 2 idB OO's itel t f * *' H26 a H-$1 RB -OU9-70 3 - 1 HJ% 2 H \\t 2 VB (M*> In: i 2g p,3"' N2 7 4 H-$3-2-FB-009-705-t H2d H-% s Fe -CO3 - 106 t H29 : H 2 - PB - 009-107 - f ,g y H30 : H-St-2-RB-003-706-t Ho f 40 H31 H-51 2 RB-001-i t0-1 H32 s M-St-2 PB-003 F091 4, 45 ^ 44 ILLUSTRATevE USE Ort.Y KDTES: DESCRIPT ION: SAFETY INJECTION / REACTOR COOLANT U l T/SCH: 4 31.4 38*/160. t 1.5*).28 t*/160 CPSES UNIT 2 BRP: RC-2-RB-OS9, 51 RB-OO7. 51 RB-008. INSERVICE INSPECT 10N s t RB-OO9 LOCAT10N ISOMETRIC MMg g[q JP g / $( FLOW: u2-0250, u2-026 TC x -I-4 306 lREv.1 l 09-01-94 APPROVAL: 7 T C x 14 3061.is t m

  • w..

- -s. -w-. + .--w.- =

e- -P w'g REF. t 4304 g s,f 2 y ac os 3 .f a T - scr> n- /' 6/ -sosac ni : am c em u ; e i ittusruravt USE ONtf NOTES: DESCR IPT 10N: REACTOR COOLANT T /SCH: (2*).344 /160 CPSES UNIT 2 BRP: RC-2-RB-061 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: [O//[gy M[m %/-f9 FLOW: M2-0250 TxC-I-4307 lREv. l 09-01-94 I T C x 14 30 71.151 '/

l W V )' D ^ ~ ~ PUMP 3l (s%-es-2-%n R.C. g r. w-o .a, 9-. [ * -245 2-607 gg 4 10 lI 1 H2 13 2CS-8350C 16 >< HI bb ,, x s-essic et Hf a H C',-J hb v11 h a 1 - HJ H-CS-2-PBist ) 70 4 -1 H3 s H-C$-2 -PB-013 - 702-1 ILLUSTRAfivE USE 0*tv NOTES: DESCRIPT ION: CS SEAL INJECTION TU ELECTRIC T/SCH: I2*).344*/160. t 1.5's.28 l*/160. CPSES: UNIT 2 t3RP: CS-2-RB-Ot3 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: [May, Mp 9./-/Y FLOW: M2-0253 TC X-t-4308 lREV. 1 - l 01-94 F I T C x 14 308 t. i d e m e , ene r 3 i+w,..m. .e%- .v-r .-r,,

-W+ G PUMP STEAM 4[/ GENERATOR ii i-4 sean ,.w i_ -h!6s

  • T iiece 9

18CD 8. m' i9 eci i . 5 62I~- ' ' * ' ' 33' 'S-kr.

-a40s s

,5lf, ) - - iseci Nf, iz n is. ,,t_$,,a. ,,,g iy- ,$[5,g - 2ms ..o .40tp REACTOR VESSEL itiU5fitAT1vE USE 04Y NOTES: DESCRIPT ION: REACTOR COOLANT LOOP 4 T /SCH: 131*12.48*.(29*12.33*.127.5*)2.21* CPSES UNIT 2 Sa-35i-Cr8* BRP: RC-2-520-ooi INSERVICE INSPECT 10N LOCATION ISOMETRIC l 09-01-94 QPPROVAL: [8[43 ((cg f,/ f*( FLOW: u2-0250 TCX-1-4400 lREV. I ic x moo us i m _ _ _ _ _ _ = - _ _ _ _.,. _,, _ _ _ _ _ _ _ _. _. _ _ _ _ _. _

s -c s ~ i r . PEF. -44y 8 , 6-4400 s E 8 i 3 D<H1 (6tf 0 10 4 st'4 ot A n ,.r u5 2-8TO28 16 8 I 9 6.* Njr to e Ht t WL ' 1%'F S l-0 4 6*' H2, oc' Za v 4o'2 c e,e M's H3 : RN 2-00?-404 (415 I2-H4 : kH 2,002 dos (4th HS : RH-2-002*407 I_4 th i. H6 : RH-2 OO2-402-C4tE -87018 H7 s RH 2-002-406 C4tR H5 : RM-2-002-40V C4tR H9 n RH-2-D02-40t-l4lR REF 2' tLluSTRafivE USE ONLY ocscRieriou, Re,croa coottur anR .y.RECTRIC ,oits, rescn: n2 n.i2svi4o CPSES UNIT 2 BRP: RC-2-RB-021,RH-2-RB-OO2.RH-2-RB-004 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: /S$w M f[-A FLOW: M2-0250. u2-0260 TCX-t-4401 lREv.t l 09-01-94 ] ~ e a m4on.m m u +w

~ + ~,.. -. - ~ ~. - - --~- - - + 1. ? s g a g / o 6 S s' ' s 1 b / 2-89480 2 Y / 2-' 5 8 i l 4 , afF. s3-4400 , to 60*a l0'=6* tt 810D. TEE

p. 32 -

nEFb t-4403 cH1 2-8 % 60 e. f i .x i fit i b e+1 e s i.'- s ez-4',-t. 4t h J 64 2 : s is2-403-cas, H1 g $4 2-l$2-402-C418 ILLU$1RaftvE USE Ou t NOTES: DESCRIPTION: SAFETY INJECTION / REACTOR COOLANT ( T /SCH: 810*l1.00*/140 CPSES-UNIT 2 .i BRP: RC-2-RB-032.'51-2-RB-070 INSERVICE INSPECT 10N LOCATION ISOMETRIC r APPROVAL: [8h y. f./ fy FLOW: M2-0250. u2-0262 ' TCx-t -4402 lREV.2 l 09-01-94 Tcx 44022.isi '/ u-m. e v, ,-t r- --*n. .,4-,v -e

t- - - - - - ~ -.. ~ - - - - - - - -. RU. TCN-2-2566Ag ' l-e 2 23 A h -54 2-069 2 t II., ..qg 6-51 2-092 ~% I )(H3 3 e < 10 CP2-$5SSMR4) ,,,y 9 I 35 2 se tBCt 2-88880 RU.'f " 2-2534 est i n.a 2 4 u sm4* 4ti st:.A: tyc -sos <

  • n H3 i st-2-0 E-4054 elo H4 5 0 092-4G6-{ 4 H H5 3 51 092-403-C 415 sLLUSTRAftWE USE ONLY TU L C RIC:

NOTES: DESCRIPT ION: SAFETY INJECTION T/SCH: 16*).719*/160.42*).344*/160 CPSES UNIT-2 BRP: SI-2-RB-06 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: 'Mhw Mgy /.[.g FLOW: M2-0262 M2-0263-TCX-I-4403 lREV.2 l 09-01-94 1Cxt44032.lSt // _, _,} 1 =

N' i + 4 Hl2 h 7 Mg - Ht e 2-89490 i %8 [g uno s \\3 L6 armed woc 2 yq(, 4 m. b she jg .- 2-Sa-2-086 r Hi)< Hb "5 nir. i H* 2-2568f_ 25i-eSoso 23 22 CP2-51$5MR-Ot 20 t2 gg N "' ,,, e Cetc - rm7e* 67-Rig gus ut; u ..e f.f4 O'32 Tut i IO H2 s H %4 2 kB 052-ro2 a Y M1 s 64 Ni / Id3 0'ai IOI % e )[ .4 s H u 2,e mo4 - e H5 s H-S t FB-052-F09 - %. H. a 2 we os2 ro5-s is. u f a H s t-2 RB 052 - T% 1 33 pg, H 5 5.%ts-052 FOT-6 H9 s M-St-2-RB -052-7 tO-1 35-' uto a St-2-172-402-C4 tt T Cf8tG " B4 Mi t a S I t f 2-403-C 4 'R y,. H12 s R0-24 70-402-04t5 g4 ggg ILLUSTRaisvE USE Opty DESCRIPT ION: SAFETY INJECTION / REACTOR COOLANT TU ELECTRIC NOTES: Tesca: s >.7is / iso. 2 >.344 / iso 1 CPSES UNIT 2 BRP: RC-2-RB-Ot9.51-2-RB-042.St-2-RB-052 INSERVICE INSPECTION LOCATION ISOMETRIC K8Mys h[q [./.y FLOW: M2-0250. M2-0263 TC x-I-4404 lREV.2 l 09-01-94 f f' APPROVAL: 10 W 14 4042.151 6

w + - ~ ~ - - - - '- - -. ~. . - - - - - - - ~ ~ t

  • C., O

.*g 3 4 N b -f E'C 5 e Wf \\ s-2-8378A m y 2-s N t

  • C5 04 8 4* H ( 4 6',

ILLU5f AATIVE af4 084.1 DESCRIPT ION: RC/CS CHARGING NOTES: T/SCH: (3*).438*/160 CPSES UNIT 2 BRP: RC-2-RB-024.CS-2-RB-027 INSERVICE INSPECT 10N LOCATION ISOMETRIC CPPROV AL: ~ %hg M, ((/d/' FLOW: M2-0250. u2-0253 TC X-t-4405 lREV. 1 l 09-01-94 T C ' 14 4051. t S t .m ..m.. m

h = m, @+ i 5---.. ......5 iN I F ILLUSTRATIWE USE M T DESCRIPTIONS REACTOR COOLANT RTO RETURN : TU ELECTRIC usCn: <3 uwo60 -CPSES UNIT 2 BRP: RC-2-RB-03s INSERVICE INSPECT 10N 4 LOCATION ISOMETRIC t ] 09-Ot-94 APPROVAL: %dy, My 7.[g FLOW: M2-0250 TC x-1-4406 ]REV. s c. iaac+. i. s i b

- m s I t t 19 . g.2-0 . tls pfg $2-202 N 5 N . 4 ,,REF. / 9- ' s.-J HI 22 cutt 29 wy -FE-0927 J< ** L 3*" 8'/3*nED 23 'I / sy,-se-2-o:s ' is d 3 ,\\ "3 rse-esico ,o 16 - 15 14 \\ 'I 82 Nt a H *.3 -2 518 048-h4 i H2 H $4-2 RB-046-7(4 5 Hj g N-SE 2-RB 048 70T-t H4 s H-54-2 RB-044 TOd-t ' H5 u-Si 2-RB-u50 70s 4 hi, g H-$ 5-2-RS-050-702' 1 HI s H-$1-2-pe 050-703-1 - He e M St-2 FS 050-704 I J rs : N S I 2 -h11 050- FtV i s HIG g H St 2-R8 050 764 i Hll a t+-$1-2-RB-OSO-70 T 4 612 e H 56-2-RB-050-708 i HL) : H-56 2-RB OSO 709-5 Hl4 H-54 2-AB 050-710 1 Hi$ s M-56-2 RB 0W-716 1 ILLusinaf tvE USE Osty NOTES: DESCRIPTION: SAFETY INJECTION / REACTOR COOLANT TU ELECTRIC T /SCH: 4 3*l.4 38*/160. t l.5*l.281*/160 CPSES UNIT 2 BRP: RC-2-RB-022.St-2-RB-048.58-2-RB-050 -INSERVICE INSPECT 10N - LOCATION ISOMETRIC 4 APPROV AL: -[ 8 [#yJ g 4 $ /- g FLOW: M2-0250. M2-0261 TCX-I-4407 lREV. 2 -. l ' 09-01-94 ~ I C \\ l 440 72. t S i j g ) e n i .m_., s

e + RE'F. j 4400 j 0 i 7 -RC-2472 2 2 H1 4 2RC-805FD m 5 X XM n g y H4 H3 H2 1 to + 13 [ r h* RED i nt g 2RC-00580 \\- t4 Hf : H V fiti O '9 KB l H2 3 ft N 2 RU O.'tt K'? t H3 : H RC-2 PB 028 K)% t H4 e H-RC 2 RB-028-704 -1 H5 g H RC-2-RB-029 705-1 54 : H -RC-2 -RB-029-706 1 Hf e M PC-2-FB-029-707 1 6tLUSTRAf tvE tr.1 OPET DESCRIPT ION: REACTOR COOLANT vU l I NOTES: T /SCH: 12*1.344v i60 CPSES UNIT 2 BRP RC-2-RB-028 INSERVICE INSPECTION LOCATION ISOMETRIC ! l 09-01-94 MM, ((q f.[/Vy FL OW: M2-0250 TCX-1-4408 lREv. APPROVAL: l O t 4 4081. t S t 9 'mm .-- u.m.. m- --tm, .r-- v. . _, + --,,_._,v* s. .-._.,-y

i M' N 5 s R.C. [ PUMP 4 - s., l* 3 FLassGE I ' 2 3 4 - l'/g-C$-2-244 p o S 6/ - 2 a lW RED 10 ' y 1 y a i'tI

  • x e

. 2-C5-2 109 2cs-e3670 2cs-essoo - i2 N %A '5,_. '5 U Hi a H (5-/ bij B)$$ 034 i H2 H (5-2 RB C38 70$ 1 ' H) : H CS-2 FB C31 i% l eLLUSTRaTIwt USE MY NOTES: DESCRIPT ION: CS SEAL =lNJECTION 'TU ELECTRIC'- T/SCH: 12*l.34 4*/160. t t.5's.28 t */160 CPSES UNIT 2 BRP: CS-2-RB-031 INSERVICE: INSPECTION LOCAT10N ISOMETRIC-CPPROVAL: $[p My ft /@ FL Ow: M2-0253 TC X-t-4409 lREv. t -l 09-01-94 i. '/ 1 C x l4 4091.151 e +


,--n..~.-,---,n.

---,.--,,,~.,,,-,n,.-w, --v ,,n,, n,. --wn.-

hN ' f _ _ _ _.. _ _. ~ _. L t I i 4~ I 4-RC-2-I n - y /g h \\ PRES 5URIZER nt/ . ).' 2 e6? 3 .( H3 un est : M 2 4 3's deJ. 416 H2 : SC 135 401141$ ~ H3 i Sf -2 4 35-406-f 416 H4 : RC t M 40f-C 415 H5

  • RC -2 5 M-40t2:5tR i

ILLU$1Raf tvE US[ ONLV DESCRIPT ION: RC PRESSURIZER SURGE .TU ELECTRIC NOTES: T/SCH: 114*ll.406*/160 CPSES UNIT 2 i BRP: RC-2-RB-031.RC-2-RB-033 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: [8ggr@ (([q ffff FLOW: M2-025I TC X-1-4500 lREv.2 l 09-01-94 .._PT ri' Ed___ f i r- . -,, + rvr,- .v. ,.-+- --.wr--rm .-4m- ,r .v-v -c ,,we = w e - - --r

'A m -P / I 4 6-aC-t-O% 2-801t)& 4 gg Ill 10-- 9 l'N PRE 55URIZER tttttST9af tvE ttSE ONLV NOTES: DESCRIPT ION: RC PRESSURIZER SAFETY TU RETRIC T /SCH: (6*L7 89*/160 -CPSES UNIT 2 BRP: RC-2-RB-072 INSERVICE.: INSPECT 10N j LOCATION ISOMETRIC-APPROVAL: %Mg ((g 7./fy FLOW: M2-0251 T Cx-1-4501 lREv.1 l 09-01-34 T C y 145011.15 i / ..v. e,. ,...--.w..~.=. ..rw.--..,,-.x,--- www+v--w.-~-=--w.+e-v,w-+----v .,,eb-m...,-c -.....-~--,,#w-.-.-> w,~ .-w.w. ...~4--.-.

h l sx-w. - s \\ [ 2-ootoe . 4 I 3'/ rLi n 9- . to t<0na, .= 2 s PRESSURIZER ELLUSTRAYevE USE ONLW NOT ES: DESCRIPT ION: RC PRESSURIZER SAFETY } { T /SCH: (6*).747/160 CPSES UNIT 2 q ane ac-2-as-o72 INSERVICE INSPECT 10N. LOCATION ISOMETRIC APPROVAtt M6v/ Me P.e # rtow: u2-o25: Tcx-i-4so2 lREv.i l os.oi-34 ~ I ' f iC > t 450:1.8 5 8 4 4 .,. - -.. ~ ...,r.-c -ey...., .+..-,2,-v ,w~-v- -m- .~w, 4

i X* l i 6 5 t e 6-RC 800 4 rti 2-sotM b' FRESSURIZER .. so t h f ILLUSTRaf tvE USE ONLY DESCRIPT ION: RC PRESSURIZER SAFETY TU ELECTRIC NOTES: 1,5ca:,e,.1ir,ie0 CPSES UNIT 2 sse: Rc-2-RB-o72 . INSERVICE' INSPECT 10N LOCATION ISOMETRIC [gge Mgq f.[- A FLOW: M2-0251 TCX-1-4503 lREv.I l 09-01-94 APPROVAL: I ~ T C 41450 31.151 e ua. e-m'w e+-* ~~-rwrmn w er r., w >-w.< ~ -ew,,m-a e r,,nv~ nw, m e m.e? ~ e ,.w

\\ N l f 6-RC-2-tos s ..g S . g PRESSURIZER txas x n,rxi., T -ac-2-ise 3 ni 2 we 2 PCv-04%a 2-sooon is is ir 9 3-aC-2* t 46 39 b6*m3' RED 24 H4 4: Sw us D<l2.x x x b<!,6 a 2-PCV-04% 2-80008 23 f2 28 14 8 6 i 2 143-4,62 4_@l6 H _' t FC ~ ll1-40 3 Sif H? : et 2 141 - 4d4 e 8 6 5 h4 W -l th - 4a 4 Cn't H5 : M 2-5%-402 4 816 ~ M6 : P( 4 46 403 f 9 th H7 g h( t % 401 -{Sf 5 tit U51#aI4WE tfd ONL T DESCRIPT ION: RC PRESSURIZER REl lEF U LECTRIC-NOTES: s T/SCH: E6*).719*/160. (3*).438*/160 CPSES UNIT 2 BRP RC-2-RB-071 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: [Mg /((y fi./ 99 FLOW: M2-0250. W2-0253 TCX-1-4504 lREv. t l '09-01-94 1Cx14504fI:1 / 0 m-m m . a. m ..-u -,-mew 3me = ~ = r =~v.-. s ie- -r--m.. c-- .m

-.mm.-

g v + l l - ~ ~ - ~- I RE F. I'%eh V% 6.6..e 20 ftED. TEE T-RC-2-43 ,,4.gic.y.cgy 6 _ "d# '"v" rw 64t,, ,6 - 3 HD N I gy - 6'a 4* RED - 4-RC-2-t64 - 2-PCv-0452 ?<M)! gg, H 30 ggg,, gg,y.,g 3 ag; g,, g 3 M83< "2" H2 : RC-2-ons 423<5 6 H3 : RC-2-Clf -442 -C$ lt + 4 6 H4 s RC 2-OlP 441.tSfW g Hs a RC-2-ota 44a 4 Sik em Sw.-2-01P 4 to t st's ,s un, H7 : Et-2-Otti 43 7 -(ttH H6 a RC-2-Ute 4% (6m "Hil H9 : RC 2-OtB 434 (6tR MtO : PC. 2 -O t B 435 C 619 hit : At 2-Ole 4 53 (CHr )gg y. p,,4 Hi? PC 2-Oin 43? (6th Ht3 H+3 kt 2-ota 4Me.Is, M14 s ItC O t 9 - 4 31 -(t. 'R "'8 H15 : RC OI R 4 304 615 ,- 4-RC-2-018 )(up Hl6 RC-24.318 42% i 6 f t H17 : PC-2-Ott 426 (6 t* Hto a nr 2 osa 4% o.in 2' Ht'l a f# '3184 4 "s I L 33' \\) f g 4,3 g n.4) : Ps 2 esta ic i d e itt g gg >< H.o 8 H21 kC-2 OtB 40J 14>4 3CH3 e. H22 s kC 018-421 C itt- ' <'C ' IU 3 : kr-2 ot e d 'u ( nh )g,qj H24 a O 2-4.H6 464 C hi ?< H19 f I g,, $t H2s ac-2-oie sea-cnn s H26 : EC-2-OIB 4214 Fin 4 ><HF n gg H2 7

  • hC t*4 *il ( 8 th ItEF2 %

nig;c H23 : RC 164-400 C8tH I-4800 f H2% a RC-2-164-404 -C615 to .pyg H30 : RC-2-087 4J1{ $18. HlI?< H31 : RC 2-047 4ui-Cett Hg H32 : #C 2 -OS 'atf8 4 8 t h it.LUSTilaitut USE ose.V NOTES: DESCRIPT ION: RC PRESSURlZER SPRAY U L C RIC T/SCH: 16').719*/160. t4*).531 /160 CPSES UNIT 2 BRP: RC-2-RB-020.RC-2-RB-023.RC-2-R8-063 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: M$g MQ Mf (f l FLOW: u2-0250. u2-0251 TCx-t -4505 . lREv.4 l 09-01-94 9 T C ) 145054.t S t --5, .m.- e. ..w -r

r..,

m m. .<w

f + + i Md5H}4 H}3 ,,,4_pC,,oss "dl Hd4

i. a isg.4 tH 1 m

a a j

a e cr ;

^ a s c =0 s "2" / 47. d L s.c ato a >2 5. y.,.,4, s 4507 ptF. 0-4505 20 "U " h^y acul9 54cC. d t61 43 \\, Hen-a11 s C-4 161 402-Cdt A - H "3H l '" m 16 0 : RC -2 14 7-406-C815 4 K -2 6 28 - ^ ^^ ^ to 65 2-PCV-0455C ^ 25 2t t3 g H3 sc.2-ors.443-C5in

  • 22 tone na ac rors 444-c5ia.

n29 's H5 : FC-2 -0 75 - 4 33 -C5 tp \\ " 5'"e PED M6 : PC-2 075 435451R g., gg / 7 HI t FC-2-0T$ 434-C513. m i ac-d ors 44i-C5is I PRESSURIZER 24 H9 hr-? 075~408-(545 gg g y gyg 43g gggg ?CHJ1 Ha n s RC 2 075 423 ($1R Mt2 g RC -2 M5 43.)-C51R tr. fH 9 : ft+ $.W. 4?f s's.tk ) b N H14 : M

  • u P. 4.% i 8w 3

6815 g M - 2 65 43 (6'R gg Ht6, 3 Rt Q 075 424 (6tR gg,~ )ggg _ q q,y,gyg

  • t t i 3 ki ' sl e'*

4t)l 4 6. It 6 23 HIS : Rt 2 915 422MtW g hir H1, H!9 : FC Q47'. 425-(6tN ?cd'4 H3 H /) s ke. _'0 75 4 t I4 *Ib X [ e:75-420 4 IfG Hll e Ff ?<HI! I H2/ s &*. 41 - 404 { E tp H_- 3 W. te t. J05.,f A lp Hf g at? 4 : 90 41 405 ( 61R (+ 4 br af J 464 L'ilik et '+ ; k* is,. 10 5 i tille ne r : s - i.e 4 e ( ei. acHu .e4, sea i.,o =u (m. n.s e or -2 ras 4oi-reiR - b-' HM : P( 2 0A5 409-C8ti.

  • m f

l H31 : FC-2-OA9 406-(8 tt )( Hll H32 3 RC-2-083 404{St6 REF b M13 : Er 2 039 an3 rnis 1-4400' Hl4 : Pf 2-141 40 5 (. 8 t7 H35 s PC-di42 *)a<eiR >cmo H36 : RCQ-147 40bC$te 4 H 3 T e GC 14 7 405 -C8 tp Hi >*18 : RC Q -iW1 are { Att Hh: RC '2 MI 401 T8tf J tuusinativt USE oro DESCR IPT ION: RC PRESSURIZER SPRAY TU ELECTRIC-NOTES: T /SCH: (6*).719'/160,(4*).531/160 CPSES UNIT 2 BRP: RC-2-RB-025. RC-2-RB-030. RC-2-RB-0 7 3 INSERVICE INSPECT 10N LOCATION ISOMETRIC Mgery,hgg $ 4 8/ Flow: u2-0250. u2-0251 TCX-1 -4506 lREv.< l 09-01-94' APPROVAL: I T C 11 E06-4. I 51 9 %e. m --..-2 -.r--- _.,',,.s -m---.,. .--mm

-.m m m. h I .v. $ m '-' .of <8C) 7 HM?C 2-8845 Ik H 34)( 35 2CS-837f 3 H33 i '6 5 4 $@ $3 ' '2 Cs-2-ii? 1-2-=C-2-i 32 34 3 6 H12)< H1 : H C. 25dt!-021 F 1". t 32 ' $0 H2 : H-CS-2-RO -02t il4-1 H3 : H-CS-2-RB 021-713-8 H4, H4 : H CS-2 RS O25 112 t H5 s H C$-2 -PH 021 fil I HS - w 3i, H6 H CS-2 Pft-021 it0-t 33 H7 : H CS-2+B-021-F09-1 H8 : H CS-? +B-02 5 - 318-t H9, H (s.2 GB O21-7v8 I 30 - 88 H10 H C5-2 +B 021. Foi - t 4HIII H-CS 2 +042t-foot H)9)< ',12 Ht2 : H-CS-2-PB-021-TM-1 H H M13 s H (5-2 4B423-704 3 ' 21 .,A, _ %I H14 s H C5-2 48 -021-1031 ng HIS e M-CS-2-RB-021-70 t g4 a a , 33 ,5 Ht6 : H -($-2+B -Q21 - Tg 3 - 3 yN. Hi? t H -CS-2 -RB -t)2 3-TOI -l '8 H23)C "'8 8 "~ C5' 2 "B '02 3 - Tu2 1 , 19 n.$ Mt3 : H C5-2+H-023 -795-1 H2O s H C-2-RH O23-F04 1 H22)( B6 H21 : H-05 2-RB -023 TM-1 HI CS-2-t t2 H2.4 g It-(5-2 RB-023-Tis (. ) - HJla H ($ 2 RB O23-Tuli Md hh H24

  • N CS-2 isB-023-fus i

/ H25 H-(5-2 RB-072-701 t 27 8>( H -4)C H26 g H C5-2+8-OF2-702-0 H 26 H.*t))( f4JT a H ($ 2-98 4)T2-Fu3 f ggg H28 a H C5-2+h -0 T2-704 1 - 25 '"I U HIS)< H29 : H (92-RR472 7t% 1 ~ [} tt is' a 14 e '. ? His HJ4 10-8 4 LFU Hit s la t ',.* 64t ot a fut t. Hie)c H32 a H15-2 346 U14 7tv I N NN M33 : H C5-2 -RB-O t4-701 -1 24 "'i>< H34 H-RC-2-98 QT3 7Q2-1 I y,3 4 21 H3$ 3 H -RC RB-O F 3-701 - t Hl4 N16 ,2, ^23 22 ^ ILLUSTaailvE LFA OttY NOTES: DESCR PT ION: CS/ REACTOR COOLANT TU ELECTRIC T/SCH: 42*).344*/160 CPSES UNIT 2 BRP: CS-2-RB-021,C5-2-RB-023.CS-2-RB-072, INSERVICE INSPECT 10N C s-2-Re-o74. Rc-2-Re-073 LOCATION ISOMETRIC-APPROVAL: gM,y [gy f. /.A Flow: u2-0251. M2-0253 TCX-1-4SO7 lREv.2 l 09-01-94 T cmso e.isi / m. .. -...,..+ .m.,e.___- -,-,.m- ,e. -.e m-

UT k* R5. F. B-4 t0Ff ,*m e*/j* ptD is 11 REF. - 3*= tYt RED g 3.,,y,.pg .e er t -420sf, 1 's, %' /y / \\ .,s m.s.ss \\", ,...,5 .,_s.., e 3 ,.st.,,,. .s K.. g-' m,.s ai, 3. -2 x.3 -c,i vis 'c=-2-256* 's[REF. MJ e 5,8 301 - 402-{ 4 tF y3, 3 3.og3 4;y, (4;g l-4306 g.:, $y.2 033 dot-CalR H5 t s,i-2-033 403-C41R m61:

  • 2 - 3 31-401 C 41 A J

4 ILLUsTRaftvE tJsE OR Y i NOTES: DESCRIPT ION: SAFETY INJEC TION T /SCH: l'*).4 38vi60 - CPSES UNIT 2 ene: SI v.6-OO8. SI-2-RB-033. SI-2-RB-048 INSERVICE INSPECTION LOCATION ISOMETRIC APPROVAL: [ Mag My f/.g FLOW: u2-0261 TC X-t-4600 l REY.2 l 09-01-94 3 TCxl#.002.151 .m m. m u .m m r m = - - e

U1 -w r + C / / ~- lJ /- f p I a 9 l i v erti i -N c = 1 V-~f l 'N .A'Q,L = t n ag< fag;rgil J hit I X-l $ ( A) ettUstaaf eve USE Mi

notes, oescairum ac.croa coouur runs i.2. ' "" '

TU ELECTRIC-CPSES UNIT 2 INSERVICE INSPECTION i LOCATION ISOMETRIC 3 APPROVAlt N8//[q //. J-9 4 - TC K-1-5 tOO ' lREV. I l 11-03-94 1 T C x t 3 t OO1. l S t / i m.. m m. m

9 e.,..--. g 68 l% l 1 Y sj 5 z N ou 9 r: I U GE 8 l + 1 H uH sy s-( g C._,, wW - i. ~ a h.Z mO .3

d 5

c\\ 4 u> e g i i W w t r 3 o s s e o \\ _J wz - l W uo I z a s i y y W x 'N \\! -) W $$ $ "a N o-W8 L, e N N r x N's OoO o za A i o E O', O X j . _ l. _. j g o l I O O 6 i g O 0.0 i w j W \\ ,. s O g," 1 Z s m-ti J s 4 es s I E d Is i w w-i i g ig l 4 5 s.e j W e i v N DE b@ l i y I?., y i o E E_ 58 EW 2 i

5 uz

( i 24 \\ 'E 6 :> !!f 'O OO g i m ) 32xO O s I .3s' s s O O i xa : y _ Q -._.-a_.'_._.-1.--_.- Q E O DO /O f /C \\ O SON' 'O/O ( O O CD O x._, l 0

  • l J

I e i' t i ~ 8 < xi j

o '- - - ~ ~ ~ ~ ' ' ~ ~ ~ ' ' ~ ~ ~~ ~~ ~ ~ ~ ~ f w = -/ N w f 5 u u h P P M, b t O \\ 1 Dw / 1 ( h o u .,.RD a_ ,a 2"7 G* g$ E "E ? g8 as tc-95 tLLUSTpsilvE USE (MV NOTES: GENERATOR NUMBER PRECEDES WELD NUMBER. DESCRIPT ION: STEAu GENERATORS l. 2. 3 & 4 If04ER RADIUS ExAulHAT ION ITEMS ARE IDENTIFIED BY SHELL & HEAD - SA-533 NUuBER WITH AN 'lR* SUFFlx. ~ Oc[ C I I Al i T 'O TtE CORRESPONDING N0ZZLE TO SHELL WELD N0ZZLES

  • SA-508 I JL0 UIN I I c

INSERVICE INSPECT 10N I LOCATION ISOMETRIC ] I l 09-01-94 l APPROVAL: g$Mg M/4 7 /-ff TCX-2-1tOO lREv. is: v ?! 1001.151 _ _ j' ~,

O\\ -wt J L ~] itetst0E 9aELL5tDE 8 ett U51Ra T 4 WE USE M V NOTES: DESCRIPT ION: CS EXCESS LETDOWN HX (TUBES IDD.750*/SA-240 t SHELLS IDD.322*/5 A-106 INSERVICE INSPECTION LOCATION ISOMETRIC l 09-01 '34 [ 6 Df f p K 64}of, T. I f '/ T C x 1110 lREV. I CPPROV AL: i e i n einousi

i i i _.q 5 l% i s $.o h., t g y u w e 5 sm o 5 [r H wg j u s 0 H a.2 Z mo 00000000 0 O Ld ] w O 0 O 0 J WZ i o O Ld W O O W U LO m> -f; O O O O 0, Wu I i O O H WO O z._; 7' O O g O O t-i O O O O i O O O O O /0 0000g00 j I m j t = 1 1 i W I y n l ] d A -} s8 i, E. "2 a x i Z 4U f I @[ M 5 b 8k ) N = a i d I 'W e = W= j B e E oM . i b i & d*n i U m~ = C cod 3 o >2m m _v W w m j 4 4 e i X ~ m g h h m d a: a W 1 h zYY we M ~ <4 x u o E u g V g_ v I

-wt . - - _ ~.. - -. - -. - - ~ - Cla$$ 3 54LL5tDE / -s -. ) ~. ILLUSTHailWE USE ORY NOTES: DESCR IPT ION: CS HORIZONTAL LETDOWN HX HE AD 15.625* tSA-2401 CPSES UNIT 2 INSERVICE INSPECTION LOCATION ISOMETRIC l 10-0144 APPROV AL: M6//fy gf gagg Q ( f t/ TCX-2-Il30 lREV. I Tr. i 13r !, i <s t ' / /

b wt '\\ /' ,. Q _ /_ l -l ~ ^ ' N z' _ r l / I / l l ,/ X, ILLUSTpaitvE USE OEV DESCR IPT i0t4: CS LETDOWN REHEAT HX tJOTES: HE AD IS.322' (SA-240) CPSES UNIT 2 INSERVICE INSPECTION LOCATION ISOMETRIC l 09-01-94 TCX-2-II40 lREV. 3 APPROV AL: N//fg K$ /7[dy's 7-I f'f w < c t i 401.is t / _.. __ w m..-

v+ r .-,~ ~ \\ 2 4' 4 \\ s / S 3 y nozzttL SLLU51aaitvE LM 084 Y NOTES: DESCRIPT ION: REGENERATIVE HX WELDS I AND 2 - 1.00"T WELDS 3, 4. 5,6 .812*T PIPE & N0ZZLES ISA-312/304) - DCEC 1 s hi I T. ') TUBESHEET & TEE (SA-182/304) FJLJ Ui1 I I C HEADS tSA240/304 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: %$/f/oy; M 74/-fy TCX-2-1150 lREv.-1 l 09-01-94 1 D 211101.151 t .... ~,, -..... - _ _

...a.. k a>.A-at =Mz-Aa a+ .<.r,.a w wee l 'h I e a= Y f u.N Su_h,;l 34.l E sm c 2 [Z wW i, s as i r j mo ca i 000000 W'] d 'l l' 0 O O 2 s 1 u_ z m i W O t W r i g > s_ i ]d %4 8 I

  • O O,z CL mu H

mo r - 0 0 U zu ? -i = = O O O l i

O O

) 'O O / Oj& O O 1 O-0 0 00 000000 y a N a 4 I.

a. e i

l w O. 2 E' W o g zh Q O'$ b 5* O 8 ad a v my 't i w+ o ~,

  • O l o 2 u1 h bC i

w <w Q 2% ~ f -g .j i j t b C b r E E \\ b N fl I ~ e W N!-l g + b. d I o I i w i d E j A / 5 $ l! l 8 1 f 5 m ! O H i o s.1 E 5 U > g O.- e a ~,

+

== - - ~ ~ ~~'~~ ~ ~~ ~ e 3 ' J 't H,1 p [k 8 32-us 2-out s si4b e Me - V"i

y:

s

--i

...t,x \\o t H6 3' g I e-uS-2-251

  • Y,"8 33--

35 2: 2MS-025 ,t* MS22 2MS-0026 / CJ u 23 i 3, ' -u l -0001 FL' 36 N jk n2 3r is u%25 (3d8 8 71BC3 FL ' 39 / 89'BC8 + }j{, '20tBCD fLS 40 "l,}'; 'j 6'sDP1N, ?BCD -.f:./,,,C, ,,, m. 2 at 4o t C 12, H4 e us-2-001 4t%< 73 C' H5 us +t:Ot -404 -( 73 H1 s %-2-d81 MS S'T2S "h 8 "I 'I~ 0"I ' "O!~ C 28 Y],,g 13 uit H8 u$-2-2ST-404 STM 'g m a us 2-00 bet 24r3 2-Hw-2333a 29, ' 24-H10 us-2-001 -4 81 -5 72R r nei a us-2-Oct-ans sT2R NT RESTRAINI CP2-uSMEh8t-O' uMinaten W Mt NOTES: LONGITUDINAL WELDS: DESCRIPT ION: M A INS TE AM IL. 2L. 3L. 4L. 5L. 6L. TL. BL. 9L. IOL. T /SCH: 4 32*ll.25*/M IN. W ALL. (24*>I.531*/100,124*11.219*/ 80. IIL.12L.13L. I4L. ISL.16L. 21L. 25L. 26L CPSES UNIT 2 8 >.90s iso.ia l.5oo,so. e l.m / iso BRP: MS-2-RB-025. MS-2-RB-029. MS-2-SB-021 INSERVICE INSPECT 10N LOCAT10N ISOMETRIC-MS-2-SB-056 1 APPROVAL: Mdn Nyh f [.$ FLOW: M2-0202 TCX-2-2100 lREv.3 l 09-01-94 T C O2100 3. t S i '/ ..r. .~,,,,

N i e s t*s tG* $l s' Rto EL-a CEN * ,).) r so-Fu-2-oss x t-,) '2 Lt6 Fu-2-07$ ,,3 4 6:12 I 6 / lii /h - S .ui. Mil to,H,i;c r alb, Hoc REF. 2-2 802 Egg T Ags Nc d g _gsg.nong r., o wa 4, 12 s 4Hii s f * -2 011' K'd (43 Og i e3 REF.2-2103 isc s f e -2 nI9 dim-CS4 y H3 a f a 2 0% 4.st wie 2F u-0083 e g H4 : F u 0%-4v2 %2R - MS t F W 2 Ul9 409 %2h g, H5 sw a 6 e.2 ns3 404 '_.*J Hf $ e 2 049 4#3 t.SJB e6 ' M6 a $ 3 049-402 (52"2 2F u-0082 H9 : F a-2-Ol9-40 3-C52R HiO i a ci9-4 t t -C 42m g, er He t i Fe 2-Ot3-412 C42K - H12 g f u 019-40t -(425 NT RESTRatesi etLUSTRailvE USE ORY ( P2-F eSSte-O f NOTES: DESCR1PT ION: FEEDWATER T/SCH: f l 8*)l.562*/140. (18'L938*/80. t l6*).84 4*/80 CPSES UNIT 2 BRP Fw-2-RB-OOT. FW -2 RB-008. F w-2-SB- 0018. INSERVICE INSPECT 10N rw-2-se-ooia LOCAT10N ISOMETRIC - Flow: M2-0203 ' TCx-2-210: lREv.2-l 09-01-94 ((MW} [h Q g(( APPROVAL: 10 x 2210l ?.151 [ - - ~ - - - - - - - - ~ -- - m --ir, e-. - = r u

'r -b- "h 32 d 33 Hli,3 lI a e~) 3g ,HI3 HI!)< 6-Fu-2-0% m j 304-40 )cg,y g l l B = int oc "k h4 up,c ns h)n y n 80 ,,34 2fe-0200 31 f.3[ ,A w' 35 36I 33 38 N14 6 4..,-0,, 3 " / x' 2-n 2>ec 20 21 .,,,. 2,r,s - u : se,s. 2 tm s..v a.s 3 sn u s, s. 2 on + +a:s 5 '6 us,e 2 o w rvo-c D it / 25 w,,. ~.m - i. e n.;* u,,,,, 2,r re + 6 e.. $ 2- ,h 16 s -64m-2-0% L It0C1,, # . 24f M.7 g I. W.2 WS 4A 'h4 ar ,.,. ; o n...2 n 2s us

  1. a -! tt% -4a i
  • 6.'k

/*" g IS H8)C 44 H) a$W OO y ., i,,. - 2 m.l'.84 8 ** T ,3 u 04 2) HI2 ; F W-2 495-404 44.}. P13 a F S-2 tW 4US-M2$ 'I und a t u 2 095-iO2-(O wt' E w-2 095-408 -Ca 25 - yy 6'5 )<. pl6 : F u 095-414 -(O 29-MIT a re-2-093-410 {62A i2 ?Fe-0 B96 weg, re.2495-415.(6;o Mt9 F a 0W 412-CO HJO s f w 2-095-4 51-CD 13 'f ag, 2-2:03 ettusinativE USE 06tv NOTES: DESCRIPT ION: FEEOwATER ELECTRIC T/SCH: 16*).562v i20. (6*).432*/80 CPSES UNIT 2 BRP: F W-2-RB-021. F W-2-RB-023. Fw-2-RB-027 INSERVICE INSPECT 10N LOCATION ISOMETRIC [. /. y FLOW: M2-0203 DNW

  • 2 !

APPROVAL: [/[ g, my r 1c c o.u.iu ,..--m_ m n

-o. + ' ~ ~ ~ ~ ? REF.2 2102 x 2Fu-Ol96 l t 16 / H6 2 . #5 HI -.t8 le 36 4 37 ?<H5 g3 -MF00t s .,tg 12 at 20 H4 0 22 to' 3 \\ 6*= 6*m 4~ "I RED TEE 2Fu-Ot92 / <.9' s ' 25 H: 2-FT-2t93 27 2s

  • y HS 29

- at H l.,. c.,,,. l. m.. H2 3 5 W 2 09I-401-562R gy H3 : F e-2-DM 404-562G-- H4. s= 2 we. roi ss2s ,.o2o, H5 : Ia-2 Oh402 563 'i 33 H6 : Fa 2 095 404-5629 t HF s m -2 on 4014628 - I* b Hit s i e -2 0%- 7(6 (L2R 35:ect / REF.2-2 tot RLLUSTamilvE USE ONLT NOTES: DESCRIPT ION: FEEDWATER I T /SCH: 46*).562*/120.(6*).432*/80 CPSES' UNIT 2 BRe: rw-2-RB-027, FW-2-SB-031 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: JC%g [g f,/. fy FLOW: W2-0203 TCx-2-2103 lREv.t ' l 09-01-94' icero5usi f i. m. m m e v s-a o -4 .~..e- .-..m. ,m.,.

t + U US 4 6 n n y

  • )

7 2-Pv-2326 Nf3 l# 52-us.2.co: - , g 34 / tH t t s-us-2-240 33 a jQ Ml2)<

  1. kI 4 g

t 32 sW l usu ,,s.oo63 'a' . gen. M560 ,g ,, [. p ' 4H21 I O 30 2 m I-0002 to Ft2. y w562 eg .gg FL3 33 20:8C FL8 39 2HBC) FL$ 40 22tect 6* tivP8 "x 4tBCD [ H 26fBCD g, " -' 2I anua u,. tht 4i. t., net s us-2 002-40s-( f.s 28 ' < 66 H3 g MS 2-002 404 -( F26 15 2-HV-2334A H4 s MS 2 002-4C6 -(125 'I r ~ 2 4-H's s W5-2 -002-405-C 7;S A HE a MS 2-002-402 C725 HI E Wi-2 CO2 100 ( T3 MOM [NT R($fRAINT He a us-2 000- 401 ( r,* CP2-W5EMR-02 H's a us-2 002 -41t S Cf4 HIO s M c2-002-4 8-572n Hi s a US-2-002-4 86-512R HI2 us 2-I40-401-$r2m Hl3 MS 24a)-402-$121s tLLUSTRATivE USE 04 Y NOTES: LONGITUDINAL WELDS: DESCRIPT ION: MAINSTEAM - IL. 2L. 3L. 4L. SL. 6L. TL. 8L. 9L.10L. T/SCH: (32")l.25'/M IN. W ALL. (24")l.531*/100,124*)l.219"/80. (8").906*/160.(8").500"/80.(6*l.789"/160 CPSES UNIT 2 ilt.12L.13L.14L. ISL.16L. ITL. IBL BRP: MS-2-RB-Ol8. us-2-RB-Ol9. MS-2-RB-027 INSERVICE INSPECTION us-2-se-Ois.us-2-SB-033 LOCAT10N ISOMETRIC [M 8[ /,/.fft FLOW: M2-0202 TCx-2-2200 lREv.3 l 09-01-94 APPROVAL: / TCx.122o03.lst e r

+. _ _..- _ - ~ - - - - - - - - - - ~ ~ ~ - ~ ~ - ~ ~ ~ - - - IHb HiI ^ a'o ( i. i, is no H9 39 87 A Hl2 tH4 20 A J3, 2. -,2 It H i 1,s to 22 66-Fs-2-Of4 q (') s is is-Hea SIE O. EL. . g g stu : F e.* oi a 4ss

4. +
  • Ie

$i64 Hig g CEN 2 l de2p s T W 2 973-443 (7) s 2, g nt6 ut3:3 f a-2 Ot9-4 A -* 1;R ,24 g l 4Hh y i W 2 -QIS 441 -{ f,9 HT)( O sH$3 : IW ? $ >ld 7. A i 6.l6 j H6 g 6 9 2 018 413h% 25 / ..y H7 : F W 2 vl8-10FL 7. R - us Fu 2 013 442 (72E H9 : 6m ? oss 441rr.w H6]c 3 g. Hio, 5 T w 2 otS -4J5-( FN, ~ HtO< gg,,, ;,,,4 4, g _, g. 4 26 v q' %^ us ht? : # e. ot a 4 t') # r.+ ' $y \\ 18-FW-2-Ot8 HI83C HIS : e m 2 ot8 4w + +.* ass nt4 : A w-2 utS 45..$ t* % 8*15

  • f 8 2 688-453 5 5'*

. 6 +416 : F W 2 Ot8-TC4C52R HI F s F e 2-016-4%-< 53 y ++1e a f e 2-Ol8-455-05.% g2-2h +419 6 s-2 ott-4ST s425 - BLLUSTeativE tfSE Cea.V TU ELECTRIC DESCRIPT ION: FEEDWATER-1 NOTES: T /SCH: t18 8.938*/80, t16*).844 /80 CPSES UNIT 2 BRP FW-2-RB-O l 4. F N-2-RB-Ol 8. FW RB-029. . INSERVICE INSPECT 10N LOCAT10N ISOMETRIC F w R B-031 M f/ M g g g g 7 [.ff FLOW: u2-0203 TCx-2-22OI l REY. 2' l 09-01-94 APPROVAL: io aows: r m... ... m-

N i s L REF.2-2201 i T ) e*,

t

. H5 / 9 0 REF.2-204 . c; 8. O na 2-M I -0006 00 'N i y REF.2-2204 Fu-0077 Y wt .,..,6 1 2 MOMENT R(5Tantui ne, a w. u % do s A t CP2-F w11 hat-02 H2 e i n-2 OE dul-w2R ~ 5 H3 s I N-2-018-432-5629 ' I - He a F e-2-018 -431-562R H5 3 F W-2-Ol8-4 M-{MR H6 F W 018-434 CSN ettustftativt U5E Oft.Y NOTES: DESCRIPT ION: FEEDWATER U L IC T/SCH: t18 31.562"/140.118-).938*/80 CPSES UNIT 2 l ese: rw-2-RB-oi3. rw-2-ss-oo34. rw-2-se-oose INSERVICE INSPECT 10N LOCATION.lS0 METRIC i MMg My A/A FLOW: M2-0203 TCX-2-2202 - lREv.t l 09-01-94 APPROVAL: 1 C ) i_'J021.151 -__,_-__-______-_-.--_.-__--._.__---_n--.__-_--_--_--. s v -nw--e +a-4 n .+

i \\n \\w ? L .--._._____._.m. - ~ ' " '~ ~ HI4 H W6 HI6 ^ ^ ^ ^ / 9 80 49 H H12 >Kuti Hit 6 \\ HI8 H9 \\ t3 thy 38 n e 14 HbCC ...,s.....% ms...... D dt9: l e. o A 4 52 ( 0,k 'H20< ' g II Hits : IWi isN 4284t H H22 H441 $ W - ? v% -422 -t L.H g, Mns fa 2 O n 7to,iq.3 H6 : s a 3_o%.435 (2sr 6-F W-2-O% - HT : F s d q M 43c-( 6;ft He : F e-2 4%-43N 62R 48 2 4 ~ us : f o -2 n% 41 4 L.'k f -) X Hao : 4 e, s k A 104 + em te q nit : sa; w e..a.: 4 e t.

  • g"

!i t 6t s ; 'L ute : I*. t,% (2 5

  • t. 8<

28 Hi3 : f e e 096 4to-(t;* iM i > ' 23 Sfas lC(M2 ble 3 f t 2 4't% 419.-CS?E HF eens # n : o% r <, cc2p - 27 H ,.. a nw,o,,.a l l \\ ,,6 Hti : 88-2 0%-712-( R j g Hi8 e f

  • 2-0W40tCE2h

-+ 3 ~ / H25;c so HIS I n-2 *)w d?O-C63 z / E "20 ' 'r'u'.2'o w 4c'3 4 3 2U*7 art.Y ' 2re-o2ci 24 s H2i i r-cs2s 2-22o4 H22 e fn 0 W TO M 63 N H24 H2) s I E 2-QW403-CE2B H24 4 7 9-2 0% 70T C62% "O * ' " * * *2 4 62' J- '26 REF. 2$ st1USTRailwE tssE Osty 2-2204 NOTES: DESCRIPT ION: FEEDWATER TU ELECTRIC T /SCH: t6*LS62Y 120.16*L432*/80 CPSES UNIT'2 -sile: r w-2-Ra-oo2. rw-2-RB-oo4. r w-2-ns-oos INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: - %gg My A [-@ Flow: M2-0203 TCX-2-2203 -l REY. 2 l 09-01-94 i / T C C220 U.15 !

'=====.+ FrCF. 2 M 34 2-ut-00i9. h g9 20 2 / Nto 34' 24 33,, 37 ,22 ' 'O 23 St 36 "'I H t)L ti '." 4 34 33 / 4 F u -2 ioo . d,2 Mai OI - "" N /ig 31 i 2F e-0113 l 8' 52 12 'U 2' to 's ,,.M K *} 2-Fv-2194 x .g 23 s O N.. 4'h ..; 4....... H.,. :< ws : 9 m 2 tw tot * *. F m it, f a 2 - too 4s4 (*,'H - 42 Jg 2FW-020$ m4 e $ m ton 403 U21t ( H". r 5 a;2 092-403 rs3 4 3 ,w lE : Fe -2 092 408-Sv2R 43 2 HT 3 F W 2 0%-700 %2R / ,b

til e t u / tr% 44.' w.%

ga,, 41 H4 3 ie / WM,444 $nd 40 h tg o',8EF. HiO : Ia-2 0% 44? (b

  • i

/ )ase> S 2202 H6s 1 Fa-2 0 W 439 <63t' ' w,ziez y# 3 ' ing y, 4 2-F - Hu. r w-2-ow ris na Y ' 2-22o2 45-. H13 3 52 2-100-801- % 34 eLLUSTRAT4WC USE % T U lC NOTES: DESCRIPT ION: FEEDWATER T /SCH: 46*).562*/120. (6*).4 32*/80, t4*l.337*/80 CPSES UNIT 2 BRP: FW-2-RB-OO4. FW-2-RB-020 FW-2-RB-026. INSERVICE INSPECT 10N rw-2-RB-030 LOCAT10N ISOMETRIC [8dg ,[gg [, /-h FLOW: M2-0203 TCX-2-2204 lREV.2 l 09-01-94 APPROVAL: / T r 'a 2 f 204J,IS t

'+ ~ [" ' ' "v#. v [g ^ T fs 6^ tHit tus-02%F / 8." \\ N, [He 3 32-us-2-003 ' 4 36 9 n -m1 wa 10 nat t 8-uS-2-223 " .ugn - 34 2 pcm6 0 33 ut2 ( )I 2mi-0098 l us 3 > u - $1u ' l CEN ) l u 14 a 42 l l ~' [h M59% FLt 3i us96 FL2 4 WSST FL3M 1 54 us-2-003 '2h8C8 mb: u, 2 o.n-4m t Tct swee r ui 2 001-407 CT.'t rt a ,o 2 mt u,-2 (p> 5-so, C 72t g,3 15 2h8CD en se u, 2 -m.t 4m e 7,5 FL5 41 w, e u 2 2-u05-401 (T2', N' 2' 4"8Ch H14 N : us 2-003-406C F2r 16 H7 e vi 2 003-402 C F25

  • m a uv2 us)-403 CY25

/25tBC, 7yiI W) e u' -2 OO3 4tt C F.'s / 26 -u I-0003 wu, e ut 2@3-404 0125 a M5 H*i r ui 1 on3-4:3 Cr2R jj9 a 27 M s us 2 00! 412 C T.* 2-uw-2335a . 62 Nt3 s us-2 (Kr3-420-573 Hl4 u$-Me) 411-SF 9 If HIS 3 u$ 2 -QO3-4 t T-$F2R 'g His s v3-2-223-404-$72K Hi7 E ui-2-223 402-SI2h wouENT RESTRasul CP2-u5t(h8t-03 4 ILLUSTRATIVE USE MY NOTES: LONGITUDINAL WELDS: IL. 2L. 3L. 4L. SL. EL. TL 8L. DESCRIPT 10N: MAINSTEAM 9t. ICL. t IL. I2L.13L.14L.15L.16L.1 TL.18L. 22L. 26L. T /SCH: 4 32*ll.25*/ MIN W ALL. (24*)) 531*/100,124*ll.219"/80. <8 >.Ti9 /i60. <8 >.soo 80. 6 >.7i9 i60 CPSES UNIT 2 BRP: MS-2-RB-020. MS-2-RB-021. MS-2-RB-026. INSERVICE INSPECT 10N us-2-SB-ois. us-2-SB-os4 LOCATION ISOMETRIC APPROVAL: M//[g [Afp FLOW: M2-0202 Tcx-2-2300-lREv.3 l 09_01-94 7 F TCx223003.tSt _--n- -.-----, - - - ,w n- --e----- ,x ~ -

i w 1 H,, tH3 X X Hf6 ' His 6*.N ut Hi Ht2 8 >( H;I 14 36 )( fHi s 4 (H22 22 pio 23 MF. 2-2303 y,%* e,. 2..., 4 i.,., Y 24 <s .c. ,,.,,..e2,,,,......, ra ,,u j g 2-MI-0007 tH33 : i e 2 ttt i 4 6. e 7.w g3 su4v e S u-2-Oti TO!..(,A 3C*4' N g II 4H58 : F OII-45 M S3 oj4-h - 4 \\ H1., 2 -o34-4.n ss;6 Hs F =s XH" e2-.-2sn 3 2. H6 t CC'2-011 4SE 56:G Q~)

  • <S. r e 2-oi F4 5+sua 4g T

2Fe-core l l Hto eFe-2 081 4% (5253 30 HF gggg gg g, g g. y og y gg g.g g, q - 20 (dN ) '. Wil 3 f e -2 s}Il 4tt (F.6v HG '8 = '6' --Ho, s e 2 -oir-eso (1.3 7 K D (LL use,gg.] n o.70FCf S 3, j 2 I / Ht$ y $ e 2 Of f lied ( f;9 F - nt6 i # e 2 ut r 4-ss (t s No-W O ' ~ ' ' Ht1 g F 8-2 0t1-4 25 (12H ^ 86-F =-2-Of 3 - [,f

  • _c(

H2O F O OI I-TuS-C 729 ns0 MENT RESTR&lNT H2 : Fe 2 017-439 C63 CP2-Fe$5MR-03 \\ is_re.2-ont "2# ' ' "- 2'0" ~d l' (52" H24 ( H23 g Fe =2-GII-4 3 }-(42$ H2e i re-2 c ar-rm-c42t 3, r SLLUSTRa t t vE USE 084 T NOTES: DESCRIPT ION: FEEDWATER ~T U - L C RIC T/SCH: (18*)l.562*/140.(18*l.938*/80.(16*l.844*/80-CPSES UNIT-2 BRP: F w-2-RB-015. Fw-2-RB-016. Fw-2-RS-017 INSERVICE INSPECT 10N Fw-2-RB-030. F w-2-RB-032. FW-2-SB-004 A. Fw-2-SB-OO4B LOCAT10N ISOMETRIC APPROV AL: M /J a g g.y A /![5r FLOW: u2-0203 TCX-2-2301 lREV.2 l 09-01-94 / / T r X /2 ?O t 2.151 _.,.___m._ m m + ,---._.-..c w. -._w-, v ,--.,_..~,.mm

~N + Hl2 HIS N14 n n n gg ">^* n ..2 )CH b H H) 84 6ej 9 Hi6 Hti Hta ,t H2O M8 ?< MT '8 " 6 4-FW-2-097 - ^ ' S oin e a e 2.nr to t t i., w ne2s s s e 2 0 st 4:e (62s< H3 : $ 5 093 704 (629 H4 t IW-2 OSI &6 f62H H5 e f a 2 097-T0J (62:a M6 f a Olf-408 (62R po H7 : F u-2-097-4T2 GS M6 He : F N 09 t-4 t !-(E;E H9 t $ 9-2-09E*416 *(629 {, 33 ' O HS = ! Hil : F W 2-097-422 CE2R HIO 3 F e 097 -417 -{ E2P z 3' 28 M'2 : Fe 2-01T-424 (62R Sine 6EN 3 l Mil a t v 091-4254., -R 4 4 22 Hl4 3 5 8 / tril 4.'t. 4 4 % - 30 a a en n 1 I His : e e 2 trat 414 eAH HI6 : fa-2 09f-428 (6 R 29 _ 4 10423 HIT g F R 2 09 F-f06 (t. 'R g quj, ' Htt : I S 2 Oil 4 51 (6.* uty a f a 2 011 -4 3u ( 6.* en ? H2O f e-2 097-433-{6?R - 3 x H21 s 7 8 017-4 35 (6.4 - M ScH2e jI H2r. s 2 o$r 4se to , Q-3\\ p' H4 2 s H: 2. Ha... 2491-.5,452 H24 a 5 3-2-097-4 39--(629 H25 Fe-2-097 707-(625 8 g3 N26 e f e -2 09 7 - D.dt ( 628 )@ l 27 2F w-0202 H2 F a 8 8 2 -091 44 8 (625 ) 2 M 23 8 ftEF. 24 ettu5inaf tvE USE ONLV 2-2303 U L RIC-NOTES: DESCRIPT ION: FEEDWATER T/SCH: 16*).562*/120.(6*).432*/80 CPSES UNIT 2 BRP: Fw-2-RB-001. FW-2-RB-003 Fw-2-RB-005 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROV AL: [8 a:pys [w f,[- $N/ FLOW: M2 9203 TCx-2-2302 lREv.3 l 09-01-94 f 1 C % : 2 5023.151 4 +. -....:-.m .a . mm. - u.--. m. .2 - - m m'---r* -- --- + w+me e--.+

  • i- --. - - +

y-wt.-eeep+- ws-'Tv4 -Om FL-4.i- --+-w+- 7 1

i s + f IIEF. 2-230?f, a i N-[N 68 'N r 2o q,, *' 4 04, 2I gg 26 65 28, 22 ><HIS 31 Ht2 6t' 25 M 60 . 23 m36 7 ' 49 yg 2Fe-OlSe 59 36 ' 18 54 ple)c ' $7 < 17 56 35 \\ 34 ui. /)33 15 HI4 64u-2-t01 y 55., ,A') /, i s"3 29 30 H ns)c a 3 32 - 2Fe-CI94 2 m2OC eu 2 g;t o "*n no xp .gf,qf ,u n, i. - i.o e.u. s u 2-rw 2ts5 .,5, s. .n.. i. c n.,

  • c.

yb u, s. m3., i.*n en o.3 ' 944 2 I E ' 2 -100 406 "(5.4 9 . g 53 4 gg

7. s f *-2 t ot -405-f 5?R bS' Hi. ; 6 e -2 fot 401-G2R eg ur, v.-2 a:.ss-rui-wen 2re-o206 43' I

He a f e 2 ti)1405-%.4 2-FW-2I43 ) ' ul i s 2 e ra f se t %.,% - 4, 5 2 H10 e f a 2 <YJT-402-%,9 .g M18 : 8s-2 017.to3-R no, s. 2+m 404 so Hi2 i s m-p,- ms,s 2-cm44sua 42. ,6 g 3c,,n, ,,,, g, ,es,,. 2-o ir,.4e+ c o. , g,, 2o u. y s, 2.,3o, 4,.. 4e - ILLUSYaalivE LI5E osty NOTES: DESCRIPT ION: FEEDWATER-TU ELECTRIC i /5CH: WL562*/120. t6*).4 32*/80 CPSES UNIT-2 BRP: F w R8-OO3. F w RB-009. F W RB-025, INSERVICE INSPECT 10N rw-2-se-o29 ~ LOCAT10N ISOMETRIC APPROVAL: g cp [ [-[y FLOW: u2-0203 TCX-2-2303 -lREV. 3 l 09-01-94 i T C) 22303 3.15 5 l g

c + i I I 3 '8 i T \\ $5 i 8 32-MS-2-004 g \\ N l'S'TIJ l ~ v . cEN, e,, 4.,a s e l-w. 6-MS+2-2I4 m gHs 3 3S M5129 2WS-026 ,ita 's(H9 2us-0134 a5 t ri I ,,ca;3 M5138 t f. wit 32 j -u l-0004 ,g 3 3 Ft2 37 37 FL 3 33 hggg un e s u\\ l +34-401 ~C 12m g fQ yy act : WS 2- 004-409-C T28 rei a ts 2 004 Fat C T.3 pgc3 ne a u 2w4-404-t r2e ggy q n i,, > 2iSCI H5 : MS-2-004-4'Jf-( T25 Y 8IN %s ' 96 : W5-2 004 405 f F2R ui s Nr a u'r? 004 406 { F2D f,DBCD 99 : W5-2-004 403-C T2' 25 try ML-2-0 M - / 2448C8 nn,, us y m,403-CF25 4i6 Sr2n 2e ,,,[' 4 nti er, 2 me ais s t.* u,2 w, 2 m4 ii2 s r.S 25 ,40 st5 : us -2 2 f 4 401 5 F2* 2m-23%a a'N use a us-2 -274-402-Si2k 2 7 NT R(STRatd~ CP2-tf5hElff-04 eLLUSTRATIVE USE 064Y NOTES: LONDITUDINAL WELDS: DESCRIPTION: MAINSTEAM IL. 2L. 3L. 4L. SL. 6L.1L. 8L. 9L.10L. IIL. T/SCH: 8 32*11.25*/M I N. W ALL. 424*)l.531*/ 8 00.124*ll.219*/ 80. 12L.13L.14L. ISL.16L.11L.19L. 25L. 26L CPSES UNIT 2 .8 >.ri9, iso. e tSoo,80. ic >.1i9,ico BRP: MS-2-RB-024. MS-2-RB-028. MS-2-SB-020. INSERVICE INSPECT 10N LOCATION ISOMETRIC us-2-se-o5s [fgm h g/ fy FLOW: M2-0202 TCX-2-2400 lREv.3 l 09-08-94' APPROVAL: V 1 C t.20t o 3. l S 1 x -~ .m ~. - -

o %mune - -P P e s -:,H;. ? CMS 5 4 3 cHio eGEN* ["is a r 6-4 ED R REF.2-2402 'l 5 564e 2-ofG I O / 2- -0008 ini a DO '\\ H's w.J , x,,, s .4.2 0-( ,, 2F'~0081 H4 Hi +His s f E-2 ta.?O 4111 C 43 2F W -008 4H3 3 $ W -2 4W) FtM f $.4 H1 g $e J t3Si-4ut $t, 48 li l H4 F W 0 3 7 -402 - 562R H5 : F e @O20 -4I 4-562R H6 s $ $-2-020-413 %M Hf a Fa ?O20-402 CS25 U2 He a Fa-7 020-80F-C526 H9 : Fs-2-020 4t6452ii HIO F u-2 020 TCI-C42# Mll : Fe 2-020-410 (425 tLLUSTRAItvt USE OrtT I DESCRIPTION: FEEDW AT ER TU ELECTRIC NOT ES: T/SCH: 418*)1.562*/140.418*).938*/80.116*).844*/80 CPSES UNIT 2 BRP: FW-2-RO-Olo. F w-2-RB-019. FW-2-SB-002 A. INSERVICE INSPECTION rw-2-SB-oo2B LOCAT10N ISOMETRIC MMg,M fL/-g FLOW: M2-0203 TCX-2-2401 lREv.2 l 09-01-94 APPROVAL: i T o m o e.isi 1- . ~. ~

'*=== s t -- - - - < - -~ - ~' i i "T 21 26 -'-- 64a-2498 HO< 2I a-28 HI fl gg g4 c~)> ,6 23 13 = p% g l )C Hil H Stu g CE" * ' - coin gi 82 5 ' 31 e g "a bld y

  1. 30 19-.

. g ) 35' 8 ]p .*+0 e 4 8 -4 '0J-IOO -( t.+ ti 34 iH 3, r e.2 49e yo3 -ce _5 /f Fw 4t95 so F a.2 H38-764-CE.3 '" 4* ' F " ') 3ft 4 t t C 5 24V-2184 6 6P,e en. &#8 +v st.,*

n. : 6 e 2 *F7tl 44 lb.*

J pty, 2-240) Hi : T R O f8 TV6 (b * \\33 )m;3 t+1 s F W 016 -424 {6:'R w3 ru-2 098 405-f625 y,_gg99 bto i F e P O98 -423'CCft I res t, F a -2 098-4 t t -C62S 32 e442 : I e 098 -4 t !-C63t NB) a F a 2-098 412-C60t ' 2 at4 i E s-2-098 4 86-{625 ' 4 M p 31 Hi$ F a IO2-403 -C62R h8Ct,' nis, a r a 2. to?- ro2-(62*

  1. ptr.

Hi,, e n z-so2-ros ren S 2-2*oi us, e. -2 io2 4o4 e tar. - ~ %LUSYaatavE USE CEV NOTES: DESCR IPT ION: FEEDWATER TU ELECTRIC i T /SCH: 16*).562*/120. t6*).4 32* / 80 CPSES UNIT-2 BRP: F w-2-RB-022. FW RB-024. Fw RB-028 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROV AL: M c5r 7J g 7- /- f y FLOW: u2-0203 TCX-2-2402 lREv.2 l 09-01-94 1ms? b .:---=~- = .,-.-..-v... w .,e,%-, .w-r ..r-=w <-. - ~.-a.- - - - + -. a>.

N 1 t ~'~* i REF. /,9 2-240tf, j i is -*

  • 2F e-0195 D4 HD-33 s

ti 38 e5 30 " #te 2F e-Ol%t 6' ' .o@ ' 22 H6 ,g 3I i 2-tv-2196 N k.* / 23 6 27, Hi 40 a a 36 V. N 24 6N 5 ,4 . He i s s 2-ir l4 J04.to 3. 2F W 4203 H,' e 5 e J cit D)!

  • 4e 3

H l ; l e 2 f fpl 4.*l

s,5 M4 : $ e -2 098 - 4.'U- %.*

. H5 : Fe 098-413 Set 2 g M6 e f a 098-4 58 5C& e NF s F e-2 498-422-5Cl* $,j H8 fa-2-0 5-405 G 2ii \\j'2 I BLLUSTRaf tVE USE ONLY TU ELECTRIC NOTES: DESCR IPT ION: FEEDWATER T /SCH: (6"3.562*/120.16*t.4 32*/ 80 CPSES UNIT 2 BRP: Fw-2-RB-028 Fw-2-SB-032 ' INSERVICE INSPECTION LOCATION ISOMETRIC FLOW: M2-0203 TCX-2-2403 l REY.2 l 09-01-94 gg [g[y h/.[y APPROVAL: S M 2 E d M _.._ - - ~ ~. 1 ~.

DW 'LMf 3 Cos450 e s2 Hi oc y st -**~ 3 2-erois,, gen.e-tioi 3.# h62x 44 / g,,,,,, ' '5 ,2 [. 2** 3 2 f H .,, RHR VALVE s Hr 4: 5' ISOLAll0N TANK. y N CP2-RHATVT-08 6 g,3x ,,35 RH-2-007 O Hoc Hsx y h - 40 m:m Id 34 . 39 39 's si.,'0 2-es,ssa,*k 33 2s ,s us4>C ?g w3 N "'O RU.2-2sai to L mu a RH-2-vuT -4#. 22.+ H2 : St-2-326-4W 533 23 'i s H3 : $ i-2-076 - 40 t -523 f H4 e 54-2 CI6-40J-022R 24 25 HS : 54 O f 6-803

  • 2. H p

',2 H6 : RH-2-007-100 523 26 H7 : RM-2-003-4ui-5425 HS H+ 2-003-40 F543 / un 33 H9 : 8ht-2 -003 - 404 '5421 21 HIO e NH' 2-003-4W 532R O wil : RM-2-OQ3 4Q8-532R "'b H12 i RH-2-003-409 5 33 79 Hl3 : RH 2 001-Filo 53.* mr 64 His, nH 2 ont 40' *;2y His RH-2-Ooi 404-5229 RHR ma puup - '5-His a RH 2-001 4 * -52 3 Hir B+ 2-oo r-4o r - 52a atLU5inativE U5E ONLY i-NOTES: LONGITUDINAL WELDS: DESCRIPTION: RHR AND SAFETY INJECllON 2L. 3L. 4L. 5L. 6L. 7L. 8L. 9L. lOL. IIL.12L.13L.14L. ISL. T/SCH: (16*).500*/M IN. W ALL. (14*).500*/M I N. W ALL. 16L.17L.18L.19L. 21L. 22L. 2 7L. 28L. 29L. 3OL 32L. CPSES. UNIT 2 (12*)l.125v 140. (12*).406*/40 33L. 34L. 35L. 36L. 37L. 38L. 39L. 40L. 41L BRP: RH-2-RB-OOl.RH-2-5B-OOI.RH-2-5B-OO2. INSERVICE INSPECT 10N Ra-2-sB-027. s i-2-RB-087. si-2-sB-024. s i-2-sB-027 LOCAT10N ISOMETRIC %[/dg,((9 [ M(/ FLOW: u2-0260 TCX-2-2500 lREv.3 l 09-01-94 APPROVAL: T C x 22500 3.151 w

  • n

D _W+ t t [ [ 4 3,v.% nu. :-440s a .b Hiry l y 3 / 5' 2-stois 2-ess es 53 p' N - 50, H13)c p 2 M3 s, N l h / 3 e Ht4?( VA(y{ g 2-utI-coo 2 ISOLATION '4 48 2'h CP2-RHATvT-02,' g 4 22 ~~ __,.* 86-nH-2-oos .'46 . 45 43. - ** '23 6 REF.2-258th -I'- h ' kg "# 4 suit a &n-2-vo4 413-14.# 2-89598. 25 t steles RM-2-tg>S - 405 5226 'E"I

ctH i p H3 Si-2 325-700 $35 H4 s 51-2-0 F5-40t -52.4 h.

40 8 HS s $1-2-07F402-522R N H6, s 5 4 2-u75,- 40 9,,,,, 5,g?F 2 RHR ,,26 )cy, y,, j (,, PUuP 2 H' ne. vi. 2 uv4 4o2 s4 w (p ..m. o,. 2 004 404 543,. 149 : kH-1 . 39 ..,4 de. u ,2e 3,s 8 8' 'N, H m Q Hi s, uH e uo. s n+ 33 H#2 g NH 2-004-40 7-53.", +H2' 29 Hl3 s RH-2-OG4-408-532# H2O 30 15 H14 : RH 2-004 4*S3.% ' /g,Is.# $2 Hl$ s RH-2-008-402 5229 52 ,,9 / "E3 H18 Ht6 : RH-2-008-4GFS226 16 3 og Hlf a RH-2-o@404 522R 3 32 11 IO His a s;H-2 -ons 40%.522R ~ HIS : RH 006-401 -5225 nig 47. H2O RM 2-008 408-5226 tttusinativt t)SE tM Y tc0TES: LONGITUDINAL WELDS: DESCRIPT ION: RESIDi'AL HEAT REu0 VAL TU ELECTRIC 3L.6t. a.20L.2it.22t. 1,sco,,, s.,.soo.,,,,. ,m.,,,. soc.,,,,,,,u, 23L. 33L. 38L. 43L. 44L 45L CPSES UNIT 2 a2 n.i2s ei40. o2 >.406 /40 BRP: 51 RB-088. SI-2-RB-008. 51-2-58-004. S t 58-005. 1NSERVICE INSPECTION RH-2-RB-002.RH-2-SB-006.RH-2-5B-008.RH-2-58-026 LOCAT10N 1SOMETRIC %[e gM f_ /-f8t/ FLOW: u2-0260 TCX-2-2501 lREv.3 l 09-01-94 APPROVAL: T C x JZ5013. It i m. w y v

~~ 8 -RH-2-022 c~ ,g g, p N .s I RHR t MN32 lit ExCte, h,/ 'N 2-rtves e 21 .W }, I e gl#g . S 2-st3ca 4 y ,3 A 84 j I, 6-#M-2-063 ~~ /s2 N.,, gg A 2-2540 2 3 38 39 2-8969 1"$ ' se 3f 2-uCv-0606 3 2.12~,.e 9 9, s-g, 3 j' *2 /63 y 32 33 Gi 2* sg ? 8-4tH-2-03F - 43 "h/ ,23 3i 6 20 22 /r 5, WE 50 / *' , 58 $5 59 52 53 M2 : R** ?-0 35 - 40 4 -532R RHR ' ettustnatevt uSE ONLT NOTES: 8'AND TO*SCH 40 PIPING 15 INCLUDED FOR DESCRIPTION: RESIDUAL HEAT REMOVAL - ^ LO T t AL WELDS: TL. 8L. 9L. IOL.11L.12L.13L. CPSES UNIT 2 (8*).322*/ 40 14L. 23L. 24L. 25L. 26L. 27L. 28L. 29L. 3OL. 4SL. 46L. 49L. 50L. 51L. 52L. 53L. 54L. SSL. 56L. 57L. SBL. 59L. 60L. BRP: CS-2-5B-001.RH-2-SB-004.RH-2-SB-005. INSERVICE INSPECTION KELD NUMBERS I5 AND 16 ARE NOT USED. LOCAT10N ISOMETRIC RH-2-SB-Ot3.RH-2-SB-Ol6 HANGER NUMBER HI 15 NOT'USED. APPROVAL: [Mg M K/ff FLOW: u2-0260 TCx-2-2520 lREv.2 l 09-03-94 v i m as202 m = e e r.ew w -a

.t 1 [ 3I a6 /- 3-RM-2-023 i ' 2-F(w-0611 RHR ,g 0 ' PUMP 23' 2 so 2S 65 'N. o s 64 33 N/ go [h a / 83' e-asa-2-064 -s P' 53 [ se-243e g,. ao., 2 7., ', /fe er e RHR 's 9 3s 2-et es '3 e4T EXClf r,o "'s / u% 's / 5' 44 i 5' ,o 35 ,, c, ,5 3 ' 39 < 25 a-sie-2-028 - / o sg s 23 r3 21 22 74 i 2-au se N42 fLtusiltaisvt USE MV I NOTES: 8' ANO IO* SCH 40 PIPING 15 INCLUDED FOR DESCRIPTION: RESIDUAL HEAT REMOVAL POPUL ATION ONLY.LONGlTUDlHAL wELOS: IOL.Ilt.12L.13L. T /SCH: 112-).406*/40. IIC L365'/ 40. 14L. ISL 16L.17L. 31L. 32L. 43L. 44L. 45L. 46L. 4TL. 48L. 49L. CPSES UNIT 2 SOL.Sil.52L.54L.55L.56L.57L.58L.59L.60L.61L.62L.63L. (8').322"/40 64L. 65L. 66L. 67L. 68L. 70L. 7 IL. 72L. 73L. 74L BRP: RH-2-SB-OO7. Ri4-2-SB-Ol0. RH-2-SB-Ol l. . INSERVICE INSPECTION RH-2-SB-013.51-2-58-006 LOCAT10N ISOMETRIC APPROVAL: [8dyf,g[q h[-[Y FLOW: M2-0260 TCx-2-2521 lREv.~l l 09-01-94 Tc rsm.isi s + ~ - - - a

NN %-W5 ittF.2-2535 uitters y ..,,s.. 1 .e x 35 + < 34 .2 e' t-aseo 33 f 36 is j' s e-q.1 30 att. 2-2532 / n l 2 v ze in a .e e, '{ f 3 2 p 2s s2 / f atr.z-253: 2-sti6e s .*f '# si 24 t _y so N s ~ p

  1. ,,p' 22 2i l

to ehti ss. ver 405 54

  • H2 e 51-2-O%-401-54N i

19 m A iLLtfSinativE USE ONLY NOTES: 10* SCH 40 PIPING 15 INCLUDED FOR POPULATION DESCRIPT ION: SAFETY INJECT ION /RHR CRY. LONGITUDINAL WELDS: IL. 2L. 7L. 8L. 9L.10L.. IIL.12L. T /SCH: 110'11.00*/140.180*).365'/40 13L.16L I TL. ISL 19L. 22L. 23L. 24L. CPSES UNIT 2 BRP: RH-2-58-Oll RH-2-58-015. 51-2-5B-007 INSERVICE INSPECTION Si-2-5B-042 LOCATION ISOMETRIC FLOW: u2-0260. u2-0262. u2-0263 TCX-2-2530 lREV. 2 l 09-01-94 APPROVAL: R$dya $[g [./ f Y T C X225302. t S t / m-w--e9% a 4 - m m ..ege

N. 4 .+ w l } 2-sellM ' 4 4 4 s a 11 f' i / 2. 'I ,/ s i. '5 p t le i3 t ,,12 [ 88 no 4 e e q 7 o_ '( N L N a .s AU. 2-2530 b 4 i a y 2 2-a130av', au.2-252 Y' suustmaist ust mv NOTES: lO*SCH 40 PlPING 15' INCLUDED FOR POPULATION DESCRIPTION: SAFETY INJECTION /RHR I ONLY. LONGITUDINAL WELDS: IL 2L 3L. 4L T /SCH: ( t 0*)l.00*/ t 40. t t 0*).365*/ 40 I -CPSES UNIT 2 BRP RH-2-SB-O l l. RH-2-58-0 t 4. 51 58-031. 51-2-58-040 . INSERVICE INSPECT 10N LOCAT10N ISOMETRIC- %h Mh ~ f /-f'/ FLOW: u2-0260. M2-0262. W2-0263 TCX-2-2531-lREv. t -l 09-01-94 APPROVAL: I C x 22531 t.ts i 7 1 ~ - m ,.mm

~ W .t' l ' ' ^ - ~ ~ , f REF.2-2533 ~ EE E ***lM4 5 !s j .0 selv 2-2s19 W f .p i H4 2-4809a e N 4' ~ 2.gyli O n f 19 If < 39 ts '4 38 . 33 s 1 24 .g g O gp ? / p# f io " 35 2-eresa / i g 34 9' gy s / j ,,33 ~ /, 2. n b ? n + Y '5 31 2 ,A 'E ...,f 23N', % s. f 'tr 2-2s30 n s-Mr 2-2520Y ' ittusinaisvt ust out, NOTES: 8* AND IO* SCH 40 PIPING 15 INCLUDED FOR DESCRIPT ION: SAFETY INJECTION /RHR POPULAT ION ONU. LONCITUDINAL WELDS 3 5L. 6L. 7L. 8L. T/SCH: i l O*l l.OO*/ 140.l l O*L365* / 40.t 8*L322*/ 40 9L. IOL. IIL.12L.13L.14L. ISL.16L.17L.18L.19L. 20L. CPSES. UNIT 2-23L. 24L. 25L. 26L. 33L. 34L. 35L. 36L. 37L. 38L. 39L. 40L BRP: RH-2-5B-Ol4.RH-2-SB-Ol5.RH-2-SB-016. INSERVICE INSPECT 10N RH-2-SB-OI7.51-2-58-038.51-2-5B-039 LOCAT10N ISOMETRIC . ggg gd f./fy riow: u2-0260. u2-0262. u2-0263 TCX-2-2532' lREv. I l 09-01-94 APPROVAL: V Tr < VM21.iS t ._-__,__.m_._.__-__--__._____________m_ e m ,.e.

~ l t r ~-- i k i Her es s'. un. X X D,3 X,,M - - -1 atF. 5-4202 ,4 2-esies 'I 46. a 5 0 041 - * -- - 6 58-2-327 1 Nte Hl1 / ht?, - i 12 n,, ms m4: 'I H90 s ..,3, .i L 10 j tt) nez. 3REr.4-4103. .a., i

  • e e t >

g,, g _ p,7,4,,,_ g 2-sstaa 6 y tH2tg $4 2-OSI-412 (43 y n6h r 51-2-08 7 ta.4 -(41 g .A g skaa : '.s 2fta7 ara e4'.S M g'J,E \\, / 4H'J e ",i 2 yt t 40 # ( 4,H N og 4 (~ HEl s $ 3 64 7-414, { 4,4 x 'g ' D' ur s ss 2-os:-4w C43 /3 ^ O M9 t $1-2-OST-402 C42R M w9, 53.y.og y.ao3.g 42R O Hr .N10 t $1-2-087-433 C42m Mi t 5t-2-087-464 (43 y s - ut: s Ss ? OtT-4M C42R [' Hti il 2-081-415 C43 s Hl4 s 5 8-2 08 t* 4tO-(4_%,a His, si-2-os t 4or.c42 y2-20004 d'E s 2 08 7-a 6 T-C42m

  1. EF. 2-2532Y,

HBT a $t 2-32 f 00t (43t 4 stLUSTRAY6vE USE (MY TU ELECTRIC DESCRIPTION: SAFETY INJECT ION NOTES: I /SCH: 11O*)1.00*/140,(8*.906*/160.(6*l.719*/160 CPSES UNIT 2 BRP: SI-2-RB-026. S I-2-FB-02 r INSERVICE. INSPECTION LOCATION ISOMETRIC APPROVAL: - g8gqg ggg ,9_ /-/ / FLOW: u2-0262. M2-0263 TCX-2-2533-lREV. 2 l 09-01-94 5 ~ / { 1C O25332.151 w G-m - __am,-.__. . 2.2 ...u ... m m -. v-w=>-wa*m .ams-e .rw- - = v .-nw-v- -a>-e ..-wm e w ,w a -fr, -r .-e-*ve---'

4 1 w Mf. 1-430p 4 2-88 88C MF. II 'gl-4403 20 4 j.~ 6-$1-2-329 '" / 25 S3 N 88 24 11 g 6 22 s.sn 2.Oes ,.h60 8 2 4 HA [ g tM i t 51-2 648 409 -L4.4 l' g oci, si 2 r,se 490 ( s.* ~ 2 4 00005 M3 a $1 2444-408 (44N . H4 s $1-2-OfS-41$ f 43 (, 1 *al-2-o84 -414 (' 4.4 g.. g} a' 4574 8 4 Tt i REF. v v v v W 6 'M, 2 8 4H'.4o3.g 4 p h4 ps3 ast a 4% 191 u,,5 y ggg 2 #'38 9 90 ti (2 Ha Sa 2 068 402-04 5 [ ^ ^ ^ ^ W9 56-2-068-412-C4 P HIO a $1 09% 401-C 429 Hs I S t 088 4 5 3 -C4.~9 - Hi2 : $s -2+69 - 4 46 -042R ILLUSTRaf tvE USE OftY NOTES: DESCRIPTION: SAFETY INJECTION TU ELECTRIC T/SCH: (10*11.00*/ I 40. t8*).906*/160. (6*l.719'/160 CPSES UNIT 2 BRP: SI-2-RB-Ol3 SI-2-RB-046 INSERVICE INSPECTION LOCATION.lS0 METRIC GPPROVAL: Mggw ((g [ /-/K FLOW: M2-0262. M2-0263 TCx-2-2534 lREv.2 l 09-01-94 __a . ic c2sm.is i .-..%+., .+, w s

m., -m mm - .,mm._.~. .m.. -.... ~...~..... .--_.m .o _. ~ -....- -..a. w ~... ~ m . m ..~......4._ u..m._

m. u.u~.

t t .u i b t 5 __ N. + -@K 1. 5 I 1 6 7 H12 Hf) Hf4 t a n.s ys e Hl t '$pY' NtG A II s s 6 $3-2-170 % eH2) 6. I t's V. H9 He f c ,H,, I HF 2-88414 at mr.V i t-4303 - 18 Hb i 2 2-384:8 o fl(F.N I-4203 i .L H4 wiu s .s ; *, r. 41) e 4 * - - l 2 E) n-419 t 4.4* I' EH,.'s : a tH 31 : si t i t -408 - C 43 l W4 St 2 9% 418 (4.N H'. 1 st ers'. 4 t h

  • 4. 9

. 94 x 5t 2 *) 6-4J0 t o.* y NF 5 6 C% - 404 4 4;* ' 2-es ggt-oo23 14 8 : S t 0%-405 -C 4 $ gg i gg.2 0%-4 8 8-C42k r 't* I ettQ s 5t -2~O%-412-<4 k I Hit i St -2 095-4skC4:n l' 2 25 Mt2 : S i 095-4 4-C 429 Hi3 t 11 O%-407 -C 42R Hte : 5 t 0%-413 -C 42m i Ht5 5 t 015-408-( 4M tituSTitatavE USE (MV i I i NOTES: DESCRIPT ION: SAFETY INJECTION TU ELECTRIC' T/SCH: 110')l.00*/140. (6*L719'/160 CPSES -UNIT '2 BRP: SI-2-RB-Ol6. S t RB-Ol 7 ' INSERVICE' INSPECTION i LOC AT ION ? ISOMETRIC f, (-ff FLOW: u2-0262. M2-0263 TCx-2-2535 l REY. 2 l 09-01-94 {- APPROVAL: e TCt225352.ist i . - w, wv ..-..,.ma. .iy+e.3 w w.,

-Y+ - -- -~ - t Y 3 2ct-o Tr y% i 6 a, s c e y Tr VALVEISOLATION-j k M

  • N TANK CP2-CTATVT-02 <

86 CT-2 m ^ e 4,a 16-CT 2-904 -+ .3 M4 A, / tH16 : C1-2-Q02-402 M J 2 2$$F H2 : C T t 2 3 - 4 71 -532R W1 : C 1 2-CO2-404 -53'P M4 : C T 002-40 3 52.'R M*) : Cl-2 UU2 40t SJAM ILLUSTRaf twE USE Mr NOTES: LONGITUDINAL WELDS 6L. 7L. 9L. DESCRIPTION: CONTAINWENT SPRAY EELD NUMBERS I AND.2 ARE NOT USED. T /SCH: (16*).375"/ulN. W ALL. (16').375"/S TD. W ALL CPSES: UNIT 2 BRP: CT-2-RB-092.CT-2-SB-025.CT-2-SB-034 INSERVICE' INSPECT 10N LOCAT ION : ISOMETRIC j APPROVAL: 78[gyj,[//[q [/-fp FLOW: u2-0232 TCx-2-2536-lREv.2 l 09-01-94 T C K 225362. l S i 4 .-,e-+ ww e-.- +e -~ e ,w..v,-. mw...

_.N+ h \\ 40% l y' l 2ct-oios ,c"# "h l VALVE 5 v '150LATION TANK ', CP2-CT A,TV T-OI ~...- N} 6 ,1 i 8 ,,9 t / y/" -014) Mi s g.1. 1/2-4.= S)$ D-k,- HJ t C I 122-405 -5 33 i H3 (t.; p i.ece g3;e 2-2575 M4 ( f 2-00?-403-52.* litOSTRainvE USE OR Y NOTES: LONGITUDINAL WELDS: DESCRIPTION: CONTAINuENT SPRAY SL. 6L. 7L. BL. 9L.10L. t il.12L. T/SCH: 116*).3 T5"/ST O. w ALL cuo NoueERS i A,o 2 ARE NOr uSEo. CPSES UNIT 2 BRP: CT RB-091. C T 58-029. CT 58-0 31 INSERVICE INSPECT 10N LOCATION ISOMETRIC l 09-01-94 gge f,./-[y FLOW: u2-0232 TCX-2-2537 lREV. I [8 APPROVAL: ys T0 225371.151

%D + i I i. 6 h, 2, to l 2CT-0060 g s ~ 0 CON SPRAT .p , e* 'I 2 ) ,Y f /,.d )J K'-%6% 2-253Ita "Np1 Cmg.,. 23N gy ' 22 4D l g ui = 0 2-wa 4&rs22r, 6 H2 : CI-2-024 404-522R N1 : C1 2 024-aoh 522k 28 N4 e Cl 2-024 407 -5D H5 s CT -2424-401-52.4 j IS H6 : C T-2 424-408-SD 89 20 ILLUSTRailvE tJ5E ONLY NOTES: 10* SCH 40 PIPING 15 INCLUDED FOR DESCRIPT ION: CONTAINMENT SPRAY p b POPULA TION ONLY. LONGITUDINAL WELDS: T /SCH: (16*).375*/M I N.w ALL. (10*L365*/40 CPSES UNIT 2 ITL. IBL 19L. 20L. 21L. 22L. 23L. 24L. 25L BRP: CT-2-SB-001.CT-2-SB-OO3 INSERVICE-INSPECT 10N LOCATION ISOMETRIC %gg ggg 7,[.h FLOW: M2-0232 TC x 2538 l REY.'l l 09-01-94 APPROYAL: / T C x 225 531. l S t <m-.. e e a- -n. v w w ve

A nY -] 14 83 SS 2 6 -009F no s9 2C T-0094 I 22 %) 6 5 4 24 f. is' , 2 Cte av S., so-ts.2-00% ~' 2 811USTRaisWE USE Opay 3 NOTES: IO' 5CH 40 PIPING 15 INCLUDED FOR DESCRIPT ION: CONTAINMENT SPRAY-POPULATION ONLY. T /SCH: 110").365*/40 i CPSES UNIT 2 l BRP: CT-2-58-004 INSERVICE INSPECTION LOCAT10N ISOMETRIC l $ssk^,.*is, "/" ? P-/- 97 rtaw: u2-o232 .. TC X-2-2538 A lREv. t l 09.o;_94 - ic ~ ~ ~ - -. -., ~ _. L ~

y + - -,.--- --- -~ i 20 ti'- fx 2' n M6)( O ' 22 5 23 t to - g5 bh , C 1-2-06 12 i I H8 / 2CV-0042 HI 13 k t.7 44 e4 g2-253'9a IO-CT-2-Ot t CONI AV Hf a ( T-2-025-404-52211 3 2 "2 ' CI + O26~#0I-522" 26 y M5 s (7 2-O?5-405-57?E M4 : t'i-24)25 403 S2.9 n's a (1 :-en25 4n2,22% M6 : CT 2-04 406 5328 etLUSTitativE U5E OPLY NOTES: 10*SCH 40 PIPING 15 INCLUDED FOR DESCRIPT ION: CONTAINuENT SPRAY POPULATION ONLY.LONGlTUO1NAL WELDS: T /SCm i16*l.3TS*/MlN. W ALL. I1O*).365*/ 40 19L.20L.2tl.22L 23L.24L.25L.26L CPSES: UNIT 2. cuo uuueER is is Nor usED. i. eRP: ci-2-se-oi4.ci-2-se-ois INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: MMg [,[ f [. / f y' FLOW: u2-0232 TCX-2-2539 l REY. t l 09-01-94 F T C x 225391. t S t m. . -m m u i

\\g.. u 82 Il e3 4 10 ng 2CT-0010 / 81 2CT-00 3 6 22559f N. s 3 CON WRA Y i 2 to-CT-2-012 - sLLUSTRaitvE USE Cett NOTES: 10* SCH 40 PIPING iS INCLUDED FOR DESCRIPT ION: CONTAINMENT SPRAY POPt)LATION ONLY. T/SCH: t I07.365'/ 40 CPSES UNIT 2 BRP: CT-2-SB-010.CT-2-SB-018 INSERVICE INSPECT 10N LOCATION ISOMETRIC 4 l 09-01-94 [3[qyy [,[.pp FLOW: u2-0232 TCX-2-2539A lREV. t APPROVAL: T C C5 Y3 A 1. t s t E _.____.____.______.___._.________________._________,_____e- -w.

A Y = 28 29'- 27 4 Tg0 /52 22N. 30 2b 3tN 24 2550 34 c' ,.. C5-2-063 N, 'f' 2 20 ,, m .. y\\,aN ..? "p2 2 38 IS 80 2-2520 pg 56 54 45 55 - 6 8-CS-2-561 ~h'[ ,3 5 2-t.Cw -Ci s2Ef;. 50 / 43N 43 2 3 g2-tCv-oli20 p' 4F-. y 46 ettuitaalevE USE Mt 140TES: 8'5CH 40 PIPING 45 INCLUDED FOR DESCRIPT ION: CS CHARGING POPtJLATION ONLY. LONGITUDINAL WELDS: T/SCH: (8*).322*/40 tTL.18L.19L. 20L. 21L. 22L. 23L. 24L. 25L. 26L. 33L. 34L. 35t* OCCc 1A : r e) 36L. 37L. 38L. 39L. 40L. 41L. 42L. 43L. 44L. 45L. 46L. 49L. 50L. F. J L_ J UIN I I ' C Sil. 52L. 53L. 54L. 55L. 56L. 57L BRP: CS AB-077. CS-2-AB-078. C5-2-5B-001 INSERVICE INSPECT 10N cs-2-se-oO2. CS-2-sB-oos LOCAT10N ISOMETRIC-Qgd,*/J g 43, [-[-N FLOW: M2-0253 7Cx-2-2s4o laEv.2 l 09.Oi.94 APPROVAL: ,g j m asao..,si -- i

x ~~ '~ .. L RU. 2-2579f ,s 2-4806 l 2-es01A h 2-2551 g, 6-58-2-3t t s 25 3 0 59 g /zo - 58 ,,i1 57 me hl / 33 < 32 2-8923a SS 7 6-18-2-04 g. / 2-8926 f.h 'N V h 21 ~W / y' 8 5s-z-ost ,/3r ses se 82 / 3' y y en. 3 <1 z.2s<2 4 S 4 49 40 6 6-St-2-038 4fN _ 7 / y 4 aLLUSTRaitWE USE ONLY NOTES: 6* AND 8* sCH 40 PIPING : Is lHCLUDED FOR DEsCRIPT ION: SAFETY' INJECTION. PCPUL A T ION ONLY. LONG 4 TlJOINAL WELDS: T/sCH: (8 >.322*/ 40. (6*).280*/40 CPSES UNIT 2-ll. 2L. 6L. 7L.11L.12L.13L.14t. Ist, itL.17L. Ibl.19L. 2 3L. 24L. 2st. 26L. 2L 30t. 31L. 32L. 33L. 34L. 37L. 38L. 39L. 40L. 4it. 42t. 43t. 44t. 4st. 46t. 47t. 48t. sot. sit. s2t. 53t. 54t. eRP, si _2.sa.ooi. si-2-se-oo2. si-2-se-oo3. INSERVICE INSPECT 10N-sst. srt. sst. sst. sot. sit. szt LOCATION ISOMETRIC s i-2-se-oos. s i-2-se-oi s Mh3 %_ / $ ft 0w: M2-0262.u2-0263 TCX-2-2s48 lREV.2 l 09-0 14 APPROVAL: unitu 2 's' _I _f-...- -n e

amam O

  • mms -

m v+ ~- 2f i 26 i Rt F. ,M 25 2-8 % 98 28 22 / 4 31 se as .,As 6-56-2-312 - -- 8-50-2-042 etr. 3 2-2sasg 4 it 6 a 30 t 2-e%23e 4 2s. 8 h A 50 2-070 6 i h J I t 2 515 @ PUMP 2 a situSTRailvE USE Ore.v GTES: 6*AND 8 SCH 40 PIPING 15 INCLUDED FOR DESCRIPT ION: SAFETY INJEC TION POPULAil0N ONLY. LONGITUDINAL WELDS: y f 3cg;,g.).322*/40. t61.280*/40 i IL. 2L. 3L. 4L. TL. 8L. 9L. IOL.1IL 12L.13L. I4L. ISL. CPSES UNIT 2 ia. ut. 22t. 23t. 24t. 2st. 26t. 2Tt. 28t. 30t. 3it BRP: 51-2-58-006. 51-2-5B-010 j INSERVICE INSPECT 10N -LOCATION ISOMETRIC MMhys-Mg /-A N FLOW: u2 -0262. u2-0263 ' TC E-2-2542 l REY. t l 09-03-94 APPROVAL: _j' T C X 225421. t S t . ~.. - -. __y ,m-in. v .~-a.

~Q -wt L k. + 3 at 3 j t

  • 4 34 33 6-CS-2-231 N

is ' 29 91 /z/ a 1L 'n 27 C M" '7

s 7

el 23 22 f og 6 -c s-2 -240 2 i ' to \\, 3 S.';'Mg, ~ S r-s41:a - g i giusTRattvE USE OP4 T NOTES: 6* SCH 40 PIPING 15 INCLUDED FOR DESCRIPT ION: CS CHARGING POPULATION ONLY. LONGITUDINAL WELDS: T/SCH: (6*).280"/ 40 ? 1L. 2L. 3L. 4L. 5L. 6L. 22L. 23L CPSES UNIT 2 BRP: CS-2-AB-078.CS-2-AB-084.CS-2-As-o85 IN RyI ig[Q[ 4 l 09-01-94 TCx-2-2550 ~ l REY. 1 APPROVALS [M dvl ic > 22%o t.t S t _w.w_.-a. 4+=hM"" m. -m r.i..-...- .+,_,-._ 4 r-r,,,

4 O T' _w ___._---_.n. .. - + -. - - - ~ ~ - * ~~-~- ~~ ~ ~ ~ ~ ~ ~ ~ ^ ' ~ ~ ^ ^ ~ ~ ~ ~ ~ " ' ~ ~ ' ~ ~ ~ ~ ^^ le 2-860T6 83 12 It 10 9

  • ~ **f

~ "'s r., \\ 'N 2-es24 }' N *r,, s 84F. N Yip a 2-2541 5 4 >\\ 2 i A ,.e i ' 84EF.2-2540 g' - ettusimatewE USE 0'ET NOTES: 6*SCH 40 PIPING 15 INCLUDED FOR DESCRIPT ION: SAFETY INJECTION J CS POPUL ATION ONLY.LONGlTUOINAL WELDS: T /SCH: 16*).280*/40 St. 6L. 7L.10Le IIL.12L.13L .CPSES UNIT.2 ese: cs-2-se-ooi. si-2-se-oo2 - INSERVICE INSPECT 10N l LOCATION lS0 METRIC l ' 09-01-94 AFPROVAL:' Jggy M9 f_ /-$ FLOW: M2-0262. W2-0263 ' TCX-2-2551 lREV. t 1 C x 2_'5511.15 i

  • =

j .m.,_,.._,..__._.,___._.-.4 ,,....,_,,,,a,,. ._g. m... m.... m.

i g O W + M t "2S 'se HJ6 1 2-93058 , )23 'f ftU. 2-88tG8 3 4203 22 stU. t-4303J, i I'O H24)C f 'P ^) Hj""d6 */ _ "d* N2 2e ^ 5 ^ ^ ^ e s.1 fi.4, 19 _ 2wt ,6 4 , t2 -j g 2-50-2-057 - 8I 5 'M ' 8 ' b'f ' d P ' * ' i 6 IS '*O ' I Y 06 ' " ' 4 '* #2" 5 2-Mi 27 IF3n : S t O' l-40e '( 45 H44) : $ 4 2 (6 9 - 421 -( 4,k i 4 3 Q $6 g $l -2 e6 0 -42 4-f 4,9 l H5 O 4W, a $ 4, *A l - 4, 4 4. P HF, E4-2 (61 41:1, 4. * /. II HS s $1 2-t'6 8 -4 3 5 i'33 2-St-2-055 -' 33 W s $1 051 - ec5 -( 4. 4 HI h H10 t di 2 s$t 4ta / 4.S 6-11 t '4 W.t 1+ tSS h a f. il,* t a*,5 4 ne.

  • 4.1 Pl3 3 'j t -2 %I$ l 41 A ( 4_4 5

2 Me $t 2 El 4.i E 4 H s Mt% 51.?468 di e 1 t. 666 2 14 -2 46f 4 r i1M Hlf t St.J169-4h>'.4% Ht8 : .6. Mi 4 4 i44 HP) * *1 66f 414

  • 1 4

- H2() s H ",I - 2 644 u s ert - /tr,, 2-ed!!!-0003 s.e s H is - Rs-O s ae -li4 { ' 4-s6-2-058 H22,a sa 2 se ote t.r : i r 6 q tt23 : M 51-2 NH-of til (04 2 g H24 M $1-0 913 0148-303 2 e g.g

  • e25 s N-$4-24B-C i48 702-2 H26 H Si O-RB O t 48 701 -0 ILLUSTRallvE USE MT i

NOTES: DESCRIPT ION: SAFETY INJECTION TU-ELECTRIC t T/SCH: I4*l.531*/160,12*).343*/160 CPSES UNIT 2 BRP: S I-2-RB-014 A. S t-2-RB-Ol48. S I-2-RB-OIS INSERVICE INSPECT 10N i LOCATION ISOMETRIC APPROVAL: MMpg/[q f /-7</ FLOW: M2-0262. M2-0263 TCX-2-2560 lREV. 3 l 09-01-94 ir a*o u s i e .~.--:-..... - - ~ _._..._.,_.,______________.__._m___ m. ..n c wm .-v.. -. - ~. ~ e -.,,. .,,--.w.-., ,,v.-

OG' \\ 4 1 / /2t

RLF, r2

,d' Hit I S 2-aa!!IM). r' H5)< gg f:Y 32 tH2i M4)< H i t. p ),

  • g,%

n '46 2-8.Ou ,...,. 2. m ( 28 ,6

  1. 9 HI6 M18)C 27 49 I

"I N ,,gg ? D f 4 $8-2-044 -- ' 4 14 14 J H i s '. 4. int s 4 4,, A fH.): St-g t43 4fg 34y g g3 . 24 Hi g SI- ) G44 - 414 - $ 37g; H1i M .5 M4 4p, $ W Hl3r th : et J h41 -tit, ' (12 1% e $f 2 044 418 53!N '42 2 H7 s St ' 2-044 419-535 g,)q 2-89284 fis 5'- 2 04 8 4.'3 $4:G g II - 23 W ; il 2 044 4.'.2-?.40R REF.k,., HEO a 50-2-044-425 S49 Hl1

  • 5 4 2-044 -424-543 m y lto

, fjy "t2 3 5'-?-044 428 54 3 2-2562 p af H64 : Si 2 044 427 540st. h34 * "1 2 044 429 54-'R 2-88214 I hl's a 51-2 044-430-5429 Mth a SI-2-05t-404 $428i REFA Hli s 14-2-051 -403-542R 2-2567 HIS : S I-2 -051 -401 -$42H tLLU$IRAIlV( U$( Of(.T TU ELECTRIC DESCRIPT ION: SAFETY INJECT ION - NOTES: T/SCH: 44*).531*/160. (4%33 P/ 80 CPSES' UNIT 2 BRP: 5 I-2-58-013. 51-2-50-016. 51 5B-017 INSERVICE INSPECT 10N si-2-sB-ois.si-2-sB-o37.si-2-sB-o78 LOCATION ISOMETRIC i 78/7[ogg g g y f //f Flow: M2-0262.u2-0263 TCK-2-256t lREV.~2 l 09-O!-94 APPROV AL: ro :: su 2.isi ( ~ ~ --.--n-...,-w.- -.--+-m-w... - - - -v~-w,- -e ,-_e-~.-~ .v- .,.-mww e. -w s--~n


n,-rv,v,-

e

emme O D t I ~ - - ' + ~ * ~ ~ - - - ~ ' ~ ~ ~ ~ ' ? I f 1 m 23 4 TCR-51AP50-Of .,f 2 ~ 29 t9 20 2-332 a ,,is 39 he 3-51-2*335 *. I s4 ..g g / 13 ,t si t-H,2 4'. S 9 u. 4 58 2-044 4 'S seit e 54 2-044 - TOO-M3 H2 a 56-2-044-408-522G H1 51-2-044 ton-522k g He : 54-2 4 44-402-5225 Sl5 HS $ 1 044-4 34-$22R 56-2-044-405-520R HT g 51-2-044 -40 7-522R H8 s 5 3-2 044-409-52.N. I H9 5t 044-409 522R A p etttiSTRattvE USE 0*(v DESCRIPT ION: SAFETY INJEC110N TU EgLECTRIC-NOTES: T/SCH: (4*).337*/ 80. (3*).300*/80 CPSES UNIT 2 BRP: 51 2-58-017.51-2-58-019 INSERVICE lNSPECT10N LOCATION ISOMETRIC i [./.f'y flown M2-0262.W2-0263 TCx-2-2562~ lREV. 2 l.09-01-94 [g [hhg - F APPROVAL: I 10 e2%22.15 t j*

...-... ~... N ON -==. N->

REW, 2-2549 T

"'O 2 1 y 9 6 2 TCR Sl&P$l-02 .y. 17 2-.,n. ,4 3-$t-2 3%.. MT 73. p 34 P

  1. f) y.4 to

/N' H4 $l$ W2 hl u .3 2 f11'4 45 % '.1-DC s L t. Q M 44 61.22 4 H$ Hj s $ t *-0 19 fiso R.+ H4 : At - 2 0 3 3 4(A U T q ,96

  • 1 -/ 411's 4'e5 $.'4 g-

+m a Lt 2 94410 #25 M 3 HI

  • Sl'2-0 39-4 8 8 '- ' 'E 4 56-2 039 %. 4 He 53-2 011 413 s.?p.

H1 * *J _' O l't 414 %'.* MI)c NtO t St 2')M 493-522* , 3 situsta&itwE USE ONLT -U IC DESCRIPT ION: SAFETY INJECTION NOTES: T /SCH: WI.33 7*/80. (3*).300*/80 CPSES UNIT 2 BRP: 51-2-58-014. 51-2-58-02 INSERVICE INSPECTION -LOCATION ISOMETRIC p /_f 4f rtow: u2-o262. u2-ozs3 Tc x-2-2ss3 laEv. i i os-oi-94 W4p gg. ceenovat: icass3i.isi 'p______._____._____ --s,.--w m.-.-..-,..r .-w..-

O @.g i __ _ _ ~ _ _ ~ ~ t i 8 46 JO Hi IS zss-50 2-8815 NII ly 4 49 O 13 < !"8 4 2-MIII-0002 47 43 4' 1 ' I2 ? - 46 h'9'I 34 3g

c H5 N18 f

giy N hit \\ k t g%' l 2-8* a ' 45 24 9.s 2> h 4, 0 - H19 H3 h HL St 2-tMS-40'9 A4.H ' 21 79% g.ggggg e s g Q,g H2 : SI-2 -001-705-A42R 5 H3 : St<2 oot-4r4-542a 20 37 gy3 g H4 & 51-2 001 4t.)$ $4.N H5 3 51 2 001 700 54 3 g 4 H6 : SI-? 001-F01542P g g Y.t 38 39 H7 : Su-2 int rol-size 3 19 He ,5 2 noi soi.im /

  • l.* DO t IO4 ' 4. H lft 4 Hl g,9, gi,7 y,,.4jy <,, g 2 50*2-001 gg..

' Hl1 i St -2 001-426-543 M12 t 51-2 008-425-5425 Ht3 s 51-2-001 424-543 ht 4 a 51-2-001-423-542R HIS : 51 001 - 422+54.1 . [ a(F. If H16 5 9 006 - 401 -5 4.'R 2-2570 Hai 51-2-021-404-51*5 Hl8 : $1 2 021-405-542N 16 H3 Nt9 : $1-2 021-402-Sa2R H2O St -2 021-403-542R g ttLUSTaaitvE L61 ONLY TU ELECTRIC NOTES: DESCRIPT ION: SAFETY INJECTION T /SCH: 44*L531*/160. (3*L4 38*/160 CPSES UNIT 2 BRP S t AB-OO4. S I-2-RB-040. 51 5B-07 3. INSERVICE INSPECT 10N S I-2-5B-082. 51-2-58-087. 5 8 58-089 LOCATION ISOMETRIC %gayf g[w f_./gt./ FLOW: M2-0262.W2-0263 TCx-2-2564 lREV. I l 09-08-94 APPROVAL: 1 C v 22%41.151 'E - - - ~ -- ,,e .--,.w.e r.un-s. e.m. n.,, ,,-w .. +-

-t ..o p O e2 x t-t ,9 49 / e 1 6 3 sw n$ I U '$~ EN5 s'$$ I us so-r-eso-*+ size fttusipaisvt usE ONLY NOVES: DESCRIPT ION: SAFETY INJECTION T/SCH: 43*l.300*/80.(2*).218*/80 -CPSES UNIT 2 BRP: 51 58-019. 5 t 58-021. 5 3 58-022 INSERVICE INSPECT 10N LOCATION ISOMETRIC QPPROVAL: f3 h M f./- [p FLOW: M2-0262. u2-0263 TCX-2-2565 lREv.t l 09-01-94 F T C x 225651.451

i t emm.

  • =.

=

ht shit s 50 306-404-C42R tH21 s $1-2-306-486-C42R 4-SI M6 +- 50 2-066 <H35 : 5t 2-306-420-C42R H4 51 306 - 413 - C 42R H5 e si + 306 415 C426 i H24 H25 H2g H21 H '3 H21 H)O H38 H6 : $t-2 306-414 C42D g) v v v . 8Y I2h U v v v v H7 s 5t 7-306-48I-C42R ^ ^ ^ ^ 3I st V26 " 2F 28 g"N ^ ^ ^ H6 e $12-306 403-0429 H23 10 'I H1 : il 2-306 -405 C42R gj,"2# 9 29 H34 Hlo a Sa 2 306-4tS C42R ,/ 30 H35 Hig, St.2-306 402-C42R \\ H M lb Hi? : 54-2-306-ef4 C428i .et & us He 3 : 53 + 306 4 1042R - HIF'h Hl4 s $$ 2 306-42t'C4N H eb 4 14 38 HIS e 58 2-306-412-C42R M8 RU. 32 Ht6 : St-2-306 407-C42R 'g Mt5 I-4202 . Hs f a St-7-306-422-C 42R H38 P T Ht) His a g e-2-3tw.401-C42n IH1' I , c Hn ' H19 : 14-2 306-423 C42R HM $1-2-306-408 C42R 250-88t98 33 H21 s 5t-2-306-424 C42k s H22 s $1-2 3fV 425-C429 Mt2 H23 s 54 306-409 -C 42R H43)( h24 : S t 304-4 tO-C 429 Hi s H25 : S t 306-406-C 42E H48 ?< j H26, a 58 7-306-4t t -C42R pio . 24 / H2i - M 53 -2 RS-OhJh-FOn ; H41 Mce H SI-219 0108-Tot 2 H29 s H ss-2 RB-0108-7034 gg g7 23 35 H42 H30 : H-s t RB-Cl00 709 2 251-88228 ' H11 : ws RB+08-730-2 36 H12 : H-S t-2 Fr3-Ot08-711-2 "8 21 H53 : H-$ l Re -O lO8 - T 3 2 -2 20 wie)c q. u34, w g,.y.pB-Otoe 713.-2 3 H4 Mac His, H si 2 RB oin8 rt 2 H4 8 H

H SI 2 F8 -Otos itS 2 Hi swinc.

' 96 HS11 H St 2 V8 -01n8 It6-2 ,u, y,yz /q i,s,- ( Hn,.. st-2 RR-Offe IIT 2 His : H .(- Ho< st 2 Rn oi<di ria 2 4, Has i 4 . et nao e n si 2 90 nnsa per i ,g, g k,2 2366A ggg.gg ggg Mit : H-$ 5 PS -Of GA ' IO2 -2 H42 e H $1-2-RB-OlOA-703 2 H43 : H 5 5-2 RB Of GA-704-2 H44 g H-51-2 R8-0108 tot 2 H45 a H-St-2-R8-OtOB FC3-2 an. H46 : H 5 6-2-RB-OtoB-704 2 t-4302 H47 t H-$t-2-EB-OtoB-705-2 H48 H-5I-2-PB-OtOC 709-2 M49 : H S t-2 48-OtOC -710 2 ILLUSTRATIVE tl5E Optu NOTES: DESCRIPT ION: SAFETY INJECTION TU ELECTRIC T /SCH: (4*).531*/160.(2*).343*/160 CPSES UNIT 2 sap, Si-2-Rs-OiOA. 51-2-RB-Ol0B. 51-2-RB-OIOC, INSERVICE INSPECT 10N si-2-ne-Oii LOCATION ISOMETRIC $[g gy 7. [W FLOW: M2-0262. u2-0263 TCX-2-2566 lREv.2 l 09-01-94 APPROVAt t l I C x 22566?.151 F 4 <n .-e m.-,,, .c r m, e ,e e e -e.c, v-. ~ ,w.su -e. e-

sumann ~ ~ ~ ' ~ ~ ~ ~ ' - - ~ ' ' ' ' ' ' ' ~ ~ ' ~ ' I '[ 2 6 REF. g te 25 I-4103 / H7 s ^ H9 ,g 258-8st9a 2 t ' f.' ' 8 IO O ~ -Will-COOS y g, i3 f "'S / 3 y, l . 8 HI6 Hiy j "'e' M _Sc 2 259-8822D 4.4 Hpc 20. HIS 33 34 T 19 'T"N M g, 'y gg ag g $ 4y gg g H2 : S t-2-060 4-R-545 q_gg.2 060 3 6 m ygg, H3 s 54-2-060 40$-542E - i...os m. Si-2 a o e san H5 3 5i-2 060 4'>81 C4.4 2 g) N Hi, a $4 2 (h4 407 ( 4,9 2 3335 H f a H *;.l-2 f>H 'M (8 31. HM : H %I-2 M3 (P26 (*C. H9 : M-St-2 845 OS6-TU). HIO s M-St-2 FO-OSR-T04 2 - M* nil a M 51-2+8 058-Ps A 2 2*M H12 : H-53-2 PB-t48-IGI s HI) : H-St-2-F8-059 t08-2 Hl4 s M-S t-2 f*B-058 IO3 2 Ht5 H $1-2-PB 058 - 710-2 Hl6 : H-St-249 049 711 ; hli a M-51 2-RB 058 -712. HI6 H-S t PB 0%- 103-. Hl1 H $1-2 R9 CM 702 2 ILLUSTitaievt USE ONL1 'TU ELECTRIC-NOTES: DESCRIPT ION: SAFETY INJECTION T/SCH: 84*L531*/160, t2*L343*/160 CPSES UNIT 2 H BRP: St-2-RB-066.51-2-58-058.51-2-5B-072 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: [8dg Md $_ /-%f FI Ow: M2-0262.M2-0263 TCx-2-2566 A lREv.I-l 09-01-94 v ic e w eai.isi 4 ---. e. c- ..w-e

t ann. enum. \\ ~W+ er i4.pe.4 hou ft s g-p' n s' / 4 "22 i [ . 37 43 . og g,[.g "23 "25 PtF. gigc HIO< 45 46 2-8835 '$2566 .;4 y "20,' D H27 p ,A n .t./ .a, As a/S6 34 ul6 g;j 4-st 2-300 , jo wt. .s,*ss s2 a 2;i'i H ' s *16. t r45 3,."2 522H .g 6ei :

  • t

. v. 4', 4.w s23 3 c-o4*, ' roo 52;H n4 i / 33 l 2 H8 : %s -2 n45 -VT 523 ul 6 8 2-88?t8 a, s '. I J-e 45 s it d22H ,\\ ed 2 9. 045 42* $27 [ - ' I g, f' u;) 1 5 s 2 -t'. e., 4 '.2-522k M9 8 i Hi0 ; s' *2-C'S 429-522E 6 a 2 45 4m-52?A 8 - e.$g.g.o45

  1. MF.

/ - C 'S 3 ^ 522E' "8 i ' v4% 4 '.2 42> 2-2563 1 utz i M t !. 3 s-;..f 4, 4M -523 43 2# 2 24 to H i a. i s

w. b. i c..'. 0

.t ,,g on. ,.. -e h, y SI . Ht i g i 4 t+ P. 4 4 f.S Hl4 g ',3 - 2 L $*) 4 T ' $ $2R gg gg "'1 8 ' l ' 2 lS *M 5 32P t2 ni; H.TI 3 ' 6 2 6 IS 404 $ 3 & gg, gg 9 u.:t i 51 0 t$ 4b) 5 5N HJ2 g. < t 2 04'.- 413 543 H_i[ II m g 6t ' % g _t ? v >45 4 5 4 '.4f4' H li t f Hi H4s ..t, o4". 41,.

  • 4.*

4 g . wa H3 ,1 2-945-4 t0-$4.1-gi - gg H26 $l-2 445-417 $45 N7 N27 : $ 4 045-4 t S-$429 HS H28 e 5 s 045-419-540R H29 : S I 0 85 - 420- 542R gg g H 50 : S s - 2 *AO-404-542R ILLUSTitaitVE USE ONI.T i, i NOTES: DESCRIPT ION: SAFETY INJECTION

TU ELECTRIC T /SCH
441.531*/ t60. t4*).337*/ 80 -

CPSES UNIT 2 l BRP: 51-2-58-012. 51-2-58-013. 5 8-2-5B-015. INSERVICE INSPECTION si-2-sB-036.SI-2-SB-072 LOCAT10N 1SOMETRIC APPROVAL: QMg Ngp %/@ FLOW: u2-0262. u2-0263 TC X 2567 lREv I' l 09-01-H 14' ' " % i l.151 / __, __j - m. m. -m. ..u. .m __. _ - _, + m .mm . m m --..m. ,.-.____u 2 m

I .G \\ .$+


~ ~ - - - ~ ~-

-- - ~- ~ -- ~ ~ - ~ ~ ~ ~ ^ ^ ~ ~ R(F. a-4108g 258-8905a a g N 258-eat 6A 9 2-5 8 30 F h g,3 t 38 / i h H4)q 5 34 g 2-St-2-058 HIf /3} 42 a) / MI6 His ~ 2-u tII-0004 O 255 88660 4 \\ Msg a 3 250-890$D 2, v so 1' et ?C 26 ~fylg, H 2..oz. 24 1 IS-23 hi ,I-201'f a t. e.s )CHt2 H2 : S i 031 - 415 - 51.' F II .H13 2 H3 a 58-2-033-417 533 REF.Y Mll 20 S M4 3 51-2 031430 53 Y g p P H5 50 2-031-4!t 54 E 2-256} H it) 8.t t 44 : Si 2 03't-422 ~243 t'p T. M7 e St 03'l-423 54 + gg

  • el 54 033-4.'4 ' 54 N og, g i _- -.039 4 30 H3 e

g

  1. 4 E j

ut 4 Ms*/ Htt NIO Si-2-033-412 -54 P Hit a 5t-2 039-823 54N - Hl *, St 2-031-734 44 ?5' 4 Ht3 a 5t+2-031 M9 54 %

  • M'g 3

Elle a 512 052 eos 54.h HIS : 5 t 052-49) 543 ,y H5 HI6 s SI-2-052-4% (4.% ~ Mt f a 58-2 052-405-C43 HI8 a H 56-2-PB-041-702 ' Hl3 g N-S t-2 -F8-04 9 'iO4 -2 ,i a attuSYeaf tvE USE M4 Y NOTES: DESCRIPT ION: SAFETY IN,tEC T ION .TU ELECTRIC T /SCH: 14 1.531*/160.44*).337*/80.(2*).343*/160 CPSES UNIT 2 BRP: S I-2-RB-041. 51 58-023. 51-2-SB-045. INSERVICE INSPECT 10N s1-2-SB-03o LOCAT10N ISOMETRIC M Ycrw M [ w k/[Y FLOW: u2-0262. M2-026 3 TCx-2-2568 lREv. t l 09-01-94 APPROVAL: ' / _ _,.. _ _._. T C x 225681. lS i .. ~...

_,,-._,m. ...u- - * - - - " * " ^ ^ " ' ~ =. = =. i N i + St 2-CS-2 630 52 f 53 49 1 ,- 4-C5-2-016 HF gg w+ tcs-34F9A H! /f 3 4 54 4 / iL 3-C5-2-629 4 4' 60 ($ ggg.3430a 2-C5-2-343 H ([wtalFUCAL 12 CMaRC HIG $6 5 g 2CS-8387 A / 34 61 6 24$-2-482 16 05 2 gasta c 2 SS e4b' /g 2-05 2 946 51 8 " II .k . 22 b 345-2-344 2-84tSA ,) d A4 3 25 ""3'.' ,,, w:... ~ A 4s' j '23 M, M-uit da3 may g (3 2-076-402-A42k HE a (5 -2't?9 ' O' ##* gy,. $.;We 40J A43 ,M gg, u (5 2-AO 032-*4 e H9 3 H CS--2

  • AO-ON' MtQ 3 (5 2'344' * '

36 3 u p' sei s C5-2-144 # ' **I' ut2 : C5-2-On -403 -a429 -8483A 3-CS-2-075 d 3 ettusfRAlivE USE OrtT NOTES: WELO NUMBERS 20 AND 58 ARE NOT USED. DESCRIPT ION: CS CHARGlHG T/SCH: E 4*1.531*/160. (3*l.4 38*/160.12").343*/160 CPSES UNIT 2 BRP: CS-2-AB-088.CS-2-AB-092 INSERV1CE INSPECT 10N LOCAT10N ISOMETRIC l 09-01-94 APPROVAL: [Wd V1 ggy J.-/~pj now: u2M TCx-2-2569 lREV. 1 y ionsmusi . _,_, - = ~ _ _ _ - - - - - ~ ~ ~, - - - - -. - - - - - - -. - -. - - - - - - - - - ~ - - - -

===. ..[ NI . y +i - ~ ~ ' Hi 'I 4 H4, f 'O l}e 2s ..g ,g

  • /" '

CENTRIFUGAL ~ / w N N,'e 2c5-eason CHARGtNG PUMP 2 TCX-CSAPCH-02. s.,% 2-seene D 2 ,, [8 ,p '3 9'e, /3 1: s 4 34 l 42 '%) ~Ac y " 85 ' A_ ;n ?s4 se s as 43 How H$ -83878 3 I CS-2-947 2C5-84798 %tS\\ g \\ 2-44858 21 e 22% A. yyqj - ' 23 - Ht i M -2 055-4 d A4M Y ' H2 ($-2 OS$-404 A 4.4 M H3 s ($-2-085-4 (-a 42R 25 24-H4 : C5 2-Oe5-edi-A42ft H5 e 05-2-Osts-F A>-a42R - s N6 : Ci-2-M9-403-A42R - / g 12.P Mi s ($-2-QS-70U-a42R 4 {$-2-110 - 3 _ He H.CS-2-a8-07 f 405-2 a W3 : M C5 2-48-0T1004-2 ] 24N atF. ~ Hl0 : H-(5-2 48-(sU-COM '2-2569 ~ Ntl n ('5-2-146-40s -a42R t l H12 : G-2-i so Ut-a429 t J. tLLUSTeaf tVE LF'A CDAY NOTES: WELD NUMBER 41 15 NOT USED. DESCRIPTION: CS CHARGING-TU ELECTRIC + T/SCH: 641.531*/160, < 3*L4 38*/ t 60. CPSES UNIT'2 1 .2u mi6o BRe: cs AB-ori. Cs As-oss. Cs-2-se-osi, INSERVICE INSPECT 10N i ~ Cs AB-io3 LOCATION ISOMETRIC APPROVAL: [8/g/gw ((4 p,/,fy FLOW: M2-0253-TCx-2-2570' lREv. I' l 01-94 T C h 225701.151 me--e,. e-w - - ~.w- - - a a ___.-,-----.m

-~4mu.- .._is. emmeus N W wt ,sau. z-is rz 2ci-oos N est 4.* EO Hi) 18 '.IF N12)C ' 16 Hi! 13 ll H%)< HS)< Rf F. ?-2s95 en ; e i.I4 46.1 * '* 6L. & 1, +.81 rd- ,,,4 H1 : 4 ! J 01) 10 ' ,g 2'3 H4 :

  • I-t-l.s13 -443-$22H s h,'

g. H5 t 41 0l 3 421-522D Ess : e.1 2-Ot3 704-$2.'% NT : ('l-2 015 405-52 M 46, He y e' { f oll-413 $3'9 jT-2 f ra 2.t.

t 1 de T c.$ 1 H60 a f I J a):) Jt*> $ 1;l4

, 3 Hil 3 ( 1 2-013 414 $ 329 Hi? : (1-2 015-412-S42R. 1 CONT &lNh(NT Ht ) g d'l 2-O13 - 4 50 542fe qg $ PRAY 9(AT (I. I Ht4 : (I y Og ) 409-$42k gg I6 'CT 2-Ol3 - HJ )c mig, (t _;-ois 4cs.$4;, ' 4 IMUSIllAllVE USE Orts S NOTES: LONGITUDINAL WELDS: DESCRIPT ION: CONT AINMENT SPR AY TU ELECTRIC it. a.3t. *.st.st.Tt.et. *.iOt.iit.ia. ,,se,,,s.,.ys.m,,,,tt t3L. l4L. ISL. tGL. 31L. 88L. i9L. 2DL. 21L CPSES UNIT-2 BRP C T 5B-038. C T-2-SB-041. C T-2-58-06' INSERVICE INSPECT 10N LOCATION ISOMETRIC FLOW: u2-0232 TC X-2-257 8 lREv.i l 09-01-94 % % n M g g - [. /- f y OPPROVAL: T C W 2 '5 7 4 4.15 E v y-- .a v-e wo

a '=mo w4-10 $PR&T RING, 2CI-ote H ))C sa 2CI-0142 II 2 2-M !!!-001 O to g 4 t 86-CT-2-os) - H.' )C ' 4 a -.y Hi C1-245 5-423-b4 k H2 : (1-2-013 407-54 3 REF.Y ' M3 : CT-2-Ot3 c?8-C5:e 2$I1 ~ ' stLU$fRATIvt USE M y NOTES: LONGITUDINAL WELDS: DESCRIPTION: CONIAINMENT SPRAY TU ELECTRIC-lnt. ;2!:,'k.";3s* 'CPSES UNIT 2 usC. <ie >.3Ts ~,* u BRP: C T RB-OO9. C T-2-58-061 INSERVICEJINSPECT10N' LOCATION ISOMETRIC APPROVAL: fydyj Mggge $[-f y Flow: u2-0232 TC x 25 72 '- lREV. t l 09-01-94 1 C x 225 721.15 8 e .-e ,-.a w .ir., m z ..m o-a

ammmm. N \\w+ REF. A2-2Sie 2C1-0003 22 8 "v "I 28 19 ^ 20 ^ t8 es t pc M6?( -'t? 16 (ONialfaJtNT SPRAY M AT ER.2 I CT-2-OI4 s 3 HS)< 4D ' l2 HOC d to 5 -- - -j REF. 2-25ss u,, ( t 4,; 4 44 23 H2 : ( T '2-O t 4 449 S"25 9 H3 : ( T -2 014 -445 12.8 g ,H2 H4 : CI-2-Old-447 S23 H5 : CT 064-700 51.2k T j p $4 : (1 O s 443 $2.P HF : C T Ot a 415 $4.4 s I S pgA CT 2-014 4tT 54 R H9 ( T -2 014 - 4 8 9 - 5 42R sttusinatsyt ust outy NOTES: LONGITUDINAL WELDS: DESCR IPT ION: CONTAINuENT SPRAY IL. 2L. 3L. 4L. SL. 6L. 7L. 8L. 9L.10L. Ill.12L. T /SCH: 116*L3TS*/ MIN. W ALL 13L.14L.15L.16L.17L.18L 19L. 20L. 2il. 22L CPSES UNIT 2 BRP: CT-2-5B-035.CT-2-5B-036.CT-2-50-065 INSERVICE INSPECT 10N LOCATION ISOMETRIC l 09-01-94 FL0w: M2-0232 TCx-2-2573 lREv. I %8Mg ggy [- /- fy APPROV AL: t Tre ni m

  • = = =.

I I t - - - - ~ ~ ~ - - " -~ 'l 3 TO $PR&V RING 2C T-Ol46 2 H3)C 2c,4,.s e / 2-uiti-cota r 6 /5 . 4 a6-ct-2-one s s s 1 / w ni,,, g.ot4 4;i44;u [ 2ct-ooo w2, c oi4-420.sa y - H3 : C I 'O 014 4 %-(5.5 e 2 Nr ? sLLUSTRailvE USE Cte.T NOTES: LONGITUDINAL WELDS DESCRIPT ION: CONTAINMENT. SPRAY IL 2L. 3L. 4L. St. 6L. 7L. BL. 9L.10L.1IL.12L T/SCH: i l6*).375*/W lN. W ALL CPSES UNIT 2 BRP: CT-2-RB-009.CT-2-SB-065 INSERVICE INSPECT 10N LOCATION ISOMETRIC %8(an # #e R /- P y rtow: u2-o232 Tcx-2-2s74-lREv.i l o9-on-94 cPeRovAL: i - e y c:sra usi = -.

wt - - - - - - - - ~ - - - - - - - ~ ~ - - - - ~ - ~ ~ ' ~ ~ ~ ~ -' ~ h i t / 96 ><w9 L ha 3 2CT-00!? q 13 .o i g f s-(T-2-120 ,,3 i 16 0T-2-003 - ' e4% gg REF. 2 ? A '253I "I 89 g., 2f T-O 2C1-0076 I H2 / ... f 25 "4 6 2. Q' 9 2 2-2576 5 23 4 'I wo.: i; 1 + 2 4A 1 so l -s et. 24 ,ggg ' H? a i T -2 120 404-52.1

  • D-2-25F6 H5 : (T-2-120 405-52 3 H4 : C1-2-120 TOO-522P nF s (1 2-Can-4DJ-%3:R

- m 2 C f Ni *>* $ 32E Hi a e.1 -2 001 4n 3 5 329 6e a f T-2-003 4M 512'. j' / 27

  • O 2 M3-40 7 5 529

'U # I# HTO : Ci-DET. /28 Mit ci-2-003 aos 5329 s 2-2580 A.

  • 12 Cl 2 123 40t-512s

'f en U$inativE USE C u t NOTES: LONGITUDINAL WELDS: DESCRIPT ION: CONTAINMENT-SPRAY it. 2t. 3L. SL. 6L. BL. 9t. Ill.12L.13L. Mt.15L.16L. T /MH: 416*).3 TS*/ M I N. W AL L nl. in. ist. 20t. 2it. 22t. 2 3t. 24t. 2st. 26t. 27t CPSES UNIT 2 BRP: CT-2-SB-029.CT-2-SB-032 INSERVICE INSPECT 10N. LOCATION ISOMETRIC ((/((ay,, ggy[q f, A py FLOW: u2-0232 TCx-2-2575 lREV.2 l 09-03-94 APPROVAL: i 1 0 225752.151 r -- ~

..mu u. .m ..._2_... m 4 ..,... - -....,._....i._...._ o... .m..m. ___m..u.-~._~. ...m. ....m-... m..m.m m m N amme t .C, ' 'o., 20 9 s, 2CT-00F8 Hg 's 2I 's HIil HI6 ' sis ' M'tsg n2 x ~. - e2-CT-26 s, . 23 H12)G 26 g, 7 _,, y x, 4 2 <

  • 2 -oos 24

/zs 31' w4, M 33' Cont 4 5 3 HOC 00 - 6 83 ,l5 ..Hu, a 2 r.r. ++ se

  • azi (1 -2 E%- 40 r 622, H3 i 1 2 er 461 m.225 g

it y x '6 ni - H,i- / H4 o 2 o 6 *H s? + m, o.2 w. an4 s22.- 1 m, o ; w m s221 n g HT 6 I.* Ma 4% O_4 a m,, s :.. c. w r..v Er# g ( l 2 u4 401 5:2, .noe a +ous-rovse:+ II Mtl t ( T -2 Ot%- 402-522' ' M12 s Cl -2 +M-444-$22' Ist CONT. Mt3 : C T 006 4tM-5215' sPRav euur i tLLUSTaaitvE U$( OHL T NOTES: LONGITUDINAL WELDS: DESCRIPTION: CONTAINMENT SPRAY IL. 2L. 3L. 4L. 5L. 6L. 7L. BL. IOL. IIL. ISL.16L. I TL.18L' T/SCH: 112").406*/40 19L. 20L. 21L. 22L. 23L. 24L. 25L. 26L. 3OL, 3tL. 32L. 33L CPSES UNIT 2 BRP: CT-2-SB-OO2. CT-Z SB-005 CT-2-SB-029 INSERVICE INSPECT 10N LOCATION ISOMETRIC %R gey3 h/w p.A g rt w u2-o232 mWm M2 l wm+ GPPROVAL: r =- - - - - - - 1r. c s w.isi m m m 4 m.....-- s -...,,.. - -. u.-

&? nt_ L REF. e 2-25F9j N, ie. 2CT4024 Hi ,.- 96-CI 2-004 MF. , h *ES% E s' /2CT-01 85 h6-CT t2t - se H5 I i H 2CT-M25 in REF.b, ' 5 2-2578 - 10 9 I i "5 coHu mn, a e.>2i-us s2., H2 ; (1 '7-121 404 S.*2R Hi s (l.' 321 4Cl d.% H4 3 d 2

  • 121 7005LT 6

g H5 i: f -2 004-40 6 -5 326

  1. ' I\\

%: C1 + 05i4-402 53'*- e Hf t (1 -2 004 404'5L% It.LUSTRATIVE USE Orty NOTES: LONCITUDINAL WELDS: DESCRIPTION: CONTAINMENT SPRAY llL.12L.13L.14L. ISL 16L 18L. 20L T/SCH: 416*).375"/STD. W ALL CPSES UNIT 2. BRP CT-2-58-025 CT-2-SB-033 INSERVICE INSPECT 10N LOCATION ISOMETRIC APPROVAL: f3kq3 g//[

f. [-f/

Flow: M2-0232 TCX-2-2577 lREv.2 ] 09-01-94 J 16.' *.~.l5 7 7 2.15 ! ,y _m i,..m gp.._.. p,-.,,.::.y,, .,ay.. ,y p_ 3

Summme ud -WY - + - - - - - - - . ~ ~.. - - - - ~ _ _ - _. -n - - ~ ~ - - '4 32 29 f, 33-, 'A,

  1. s N14 H15
  • I 12-CT-2-007 2C T-0028

'N y is tz ~' m, ~ ', 23 / ~, 3 14, og 82 ) cme 16-3 2Ci @ 2 'y' y SPRAT 3 N4 kl. 8 '~i use,.. ? am anTT st: : 4 t : vesa 4 ni ',;ce. !+4 fa 45 s ( f 008-4u F-524* H4 : C1 2-006 406-$2214 H5 s C1 2-006-40%-$22R H6 : (1-2 4108 402-5225 H1 : CT 2-OO8-404*S22R H8 (T-2-007-403 522R 2 '. h M9 e (1-2-007 402-5228 V 82-CI-2-008 HIO CT-2-00T-405 522R usi e C t-2-Oot-404-522R 6 Mt2 : CT-2-007 406-522P M13 : C T 007 -407-5225 I His, CT-2-007-406-522R HiS C1 2 00T-450 5225 ttLU$fRATavE USE 04Y NOTES: LONGITUDINAL WELDS: DESCRIPT ION: CONT AINMENT SPRAY IL. 2L. 3L. 4L. St 6L. 7L. 8L. IOL. Ill. ISL.16L.17L.18L.19L. T/SCH: 412*l.406*/40 20L. 21L. 22L. 23L. 24L. 25L. 26L. 2TL. 28L. 32L. 33L. 34L. 35t CPSES UNIT:2 BRP: C T 5B-011. C T-2-SB-Ol6. C T SB-02s INSERV1CE INSPECT 10N LOCATION ISOMETRIC gf/((a,q gggy fL A py FLOW: M2-0232 -TCx-2-2578 lREV.2 l 09-01-94 APPROVAL: 7 - TC C2518 7.tS I =.

-I .Y-r. 1 .42 I es -A. ur I W4 %by, ' 2 so % $F2M2 g ,9 g, s. 18-50-2-030 1 2-871 mi, Vsj \\ 4 43 22552 y , 15 8 ?CH3 20 my 3own g, Jg *2i O ,, g6 r 2 2 m3, ,2 ' 5' N ~\\- y, 43 'i 34 35 [/,l [ N[) 2-6806 3' 2S . m3s : se 2+ Sv 402 L L ^ 33 '. IMF. ps: ; g,w 2 i.. e 404 5 o m4,; gig.9:4 402-532s 2CT-0024 2-254' ... 2 em 2 to 4.s. u 2 -f,,5 7 3 2-25 HI 56 7 0 36 494 'a LL 24-58-2-029 - 30 21 ne : 5 t 2-0%-403-512R Hiu g H9 : SI 2-032 401-532F H10 e St-2-914-403-532F 20 ,/ Htt 3 S t 914 41 532R 86-56-2-914 " sLLUSTitaIivE USE C44LV NOTES: LONGITUDINAL WELDS: DESCRIPT ION: SAFETY INJECT IOtuRHR 9L.10L. Ill.12L.13L.14L.15L.16L.17.18L.19L. 20L. 21L. T/SCH: t24*).375*/51D. W ALL. t18*>.375*/STO. w ALL. 22L. 23L. 24L. 27L. 28L. 29L. 30L. 31L. 32L. 33L. 34L. 3SL. 36L CPSES UNIT 2 06 >.37s,sTo.. Au. i8 >.322,4o BRP: C T-2-SB-033. RH-2-5B-030. RH-2-58-043, 1NSERVICE INSPECT 10N f si-2-sB-oii.si-2-sB-03s LOCATION ISOMETRIC [8My3 ((q ' K/ [8[. FLOW: u2-0260. M2-0262. W2-0263 TCX-2-2579-l REY. 2 l " 09-01-94 APPROV AL: F IC=JJStr.tSt -=a-a. ~ * ~ -~ ~ e. .,e s +,a- ,e ,e n ,~-,4 m

%N. .W+ Hs . g6., ...,6... 3 s \\ Hi 24-56-2-029 s .,78 m ~ v .H y, e t REFUELING WATER H 5TORAGE 'O TANK 1 H3 40 tHO p $ 4 -2 OZ Pdl5 t Lh HI2 a*2s 5 a '2-0? 3-444 1 L4 '"I' 8 5 8 '? OJ3 40'b SU "83 2 M4 : S i 901 - 40 5 v 4.4 A ,,c,s $t 2-6.'i415 i O ' Mid 3 24 tei. a

  • t 2 OJ-t 4 6 4 i t
  • H.

Hf 2 ,4 2 u,") 4ul n11 15 44 H3 : $12 0,9 Ni elk 3 7I H9 c T L-2-029-4 5*- V M- ~ h2d alG s S I-?-OJ1-442 t 'liS H4l a St 021-hs) i L5 86

  • H6 H32 ; $1-2 0 "4 4 t f t 3.%,.

28 g* ty HI 3 s $1 2-029-4VI-) 3.% gg, N14 3 $1-2 029-416 f Uh HIS f" Nt5 s $1C O?t end t lk Mt6 a 51 021428,8 3 f-gy, gg Htf a $t 2 0.'9-405-s3 + b*2Sy9 2 H2U 3 H10 HIS : $1 2-029-422-f D er ' ' Hi9 : $1 -2 0J9-406 4 5$ 39 I2 [. 6420 i $6 2 029 4?l-) L4 20 H29 : $3 2 -0 9-40F-53_$ H2' N,-NF'3 H22 i St 2-029-425 SLT H22 H23 : St 2 029+406 t L+ 2 2' M H24 s 50 029 U.-5 4. k H25 NOS 51 2 029 42 7 -$ L* g4 H26 : 51-2-023-421-S3,9 - 22 9" H27 : S t 029-429-5 32P 3 M20 t St-2-029 702-53'S 23 H2 9 3 $1 029-430-5 32F H30 s $10<c9-43153;R i 6LLUSTRattvt USE ORT ~ ~ NOTES: LONGITUDINAL WELDS: DESCRIPTION: SAFETY INJECTION 3t. 4L. 6L. TL. 8L. 9L. IOL. IIL.12L.13L.14L.15L.16L. I TL. T /SCH: 424*).375*/S10. w ALL 18L. si. 20L. 21L. 22L. 23L. 24L. 25L. 28L. 29L. 30L. 3 tL. 32L CPSES UNIT 2 i BRP: S I-2-5B-035. S t Y D-oo2 INSERVICE INSPECT 10N LOCATION ISOMETRIC flow: M2-0262. u2-0263 TCX-2-2580 lREv. 2 - l 09-0l-94 9 APPROVAL: M go, gg f /- / y 10225802.15 t ( ( # r-4 e e..-. .,-,--m-,*-+r-e r --r--e a m -, ~ _ - .mm u m m. m. -. m m.m .....m

N + H 1.' M6J I4 i-so se.2-s42 4 / H9)< 2-asira ,o ,M ,,X '- i is mr Y' H l 3.1, 8 4-5 0-2-07 8 -60em s 4-S t t%- 85 tn 2-2SF9 ,g j ? ace ?<H! mr. DCH6 EK"W 2, / s 2..m/a,$ y - / ,s 22

  • o 3

E( Oo, -esi2e 2 H6 tH! > 1 Sid-072 W}i 53;H ^ t 2 t>I; 4WS3:4

  • H2sa H1 $1 2 OI2 4+ 6 SD i

. M4 : $1-2-672-403 532$ ,g g Hs i s 2 -n r2-+,2 s sa 6*. 3 ,e 2 1 +1 set.- $15 N ar, v.2.nr 4.n s + zu y"4 H8 51 -? -1 W 401 - 5325i M9 : S t -2. tW402-532H, 23 2 uto : 56 2 iW an g 552R Hll ; $6 2 nil-402 532$d pcw3 H12 s 5e-2478-403-5325 Ml) $ 1 071 - 404- $ 32D 3, - - iREF. 2-2504 ~ 3, g SLtustpartvE USE ONtv 4 NOTES: LONGITUDINAL WELDS: DESCRIPTION: SAFETY INJECTION 6L.7L.10L.Ill.13L.14L.ISL.16L.18L.19L.22L.23L T /SCH: I18*).375*/ST D. W ALL. Il4*).500*/M IN. W ALL. CPSES UNIT 2 ti4>.3TS,STD..Att BRP: 51-2-58-005.51-2-58-025.St-2-58-043 INSERVICE INSPECT 10N LOCATION ISOMETRIC [8dw ((e 9,/- f y Flow: u2-0262. M2-0263 TCx-2-2581 lREv. 2 - l 09-01-94 4 APPROVAL: / /

18. C25F 32.15 8

.N-N- t 4 2st-oo4s e2-ss-2-ess - v REFUE, LING s a W A {Q <H i gg STORAGE TANK 1 be-6+e M )^* N w.,,,, __.s. a in.h is ?-u ti 43 V,3.t 5 .u t.,. ; m i 4 %. , t.s - gig 6t4 $1 2 011 4,* 3 i j.6 16,- 4I M19 H5 $ 1 2-031 444 V 32k N TO H6 y $1245i-foi + 326: gg H T, Ss FO3 t -4(vs-r 33 H23 el2 3, HS t El 2-t*33 IO's-I 32R ,9 H9 ss 2-01.-410-v3?P H'5 N 3g H',' 2 "!' a'o'? 5 32b 3 35 N uit : e 2 eiti s $ 1,5 3h 'C ~ ut . 2 ott 4.. $ 31. F 2 WI H.c t 3, s. 2mi w,3.w 22 -wig Hl4 3 55 2431-428 T32R 35 23 ' 36 Hg5 51 2-033 4t 3 532E H1b 4H25 - 37 Mt6 56-2-03: 4:4-$ rp 38 IS HIT : SI-2-Oll-et6 532F 24 p q g, $g.y.(33 3.gg y.33;p H17 H.4 HI9 i S t-2-0 5 t -4 t$-$W - 4y H_v r 5 6-2-031-4:9 5 32t' H21 : $3 2-035-420-SrE H22 s 58 03t -42t-532E

  • ,fatF.

H23 s' 50 2434 -422-532R 2-2543 H24 : S t -2 058 -431-532H eLLUSTRaf tvE USE Omtv TU ELECTRIC NOTES: LONGITUDINAL WELDS: DESCRIPTION: SAFETY INJECTION

a. x.

. u. TL. et. 9t. iol. i n. ix. ix. i4L. isL. ia. m.,,sc o,,,,.,.,os.,,o,,,.,.3, s., s, o.,u IBL.19L. 20L. 2 tl. 22L. 23L. 24L. 25L. 26L. 2 7L. 28L. 29L. 30L. CPSES UNIT 2 31L. 32L. 33L. 34L. 35L. 36L. 37L. 39L. 40L. 41L. 42L BRP: S t AB-003. 51 5B-048. 51-2-58-055. INSERVICE INSPECT 10N-LOCATION ISOMETRIC si-2-vo-oo3 [ 6 h g _ g /f/ g [. /, f y FLOW: u2-0262.M2-0263 TCx-2-2582 lREv.2 l ~ 09-Oi-94 i ePPROVAL: ') T C E 25822. i S I.__ d

m_ m _.m. 2-._ ...~....._.u-....m.-_~..-.-.- =. _ _ < a ._ ~._ _a 2. c. u... _.. .4. rh f c -~~ l n 20

REF, 23,,

,'Q2-254 0 Hs 30e11 I ti 18 22 24CV-Oll2E '4G g / 54 F, 32-2s4o 24C W-OtI2Df o Y "? 58 2-323 t IO Il . 9 NF & heJ< h ioc-4 Hiss 51-2-054-439-A 5J 2-2582 H2 SI 2-0 51 433 A 32R 3, , g H3 3 $ t 0 31 -44 3 A 32R H4 s SI-2431-4%-432P S I 'H2 66 $ d O!I 44?- A 32E i / ng st. a ',1 2 e534 4 M A 32H /I E I41 a 53 2 OSI 437 A4.9 M4 2 H3 3 $1 2-031-448 A42R mg M9 e SI 2 323-401-842R 3 HIO s $3 2-322-401-a42H r H'3 3 58'2'322-400 842" 4 5 6LLUSTRaftvE USE O E T NOTES: LONGITUDINAL WELOS: DESCRIPTION: SAFETY INJECT ION IL. 2L. 3L. 4L. SL. 6L.10L. t il. ISL. T/SCH: (12 2.406*/40. (8'L322*/40 16L. ITL.18L.19L. 20L. 21L. 22L CPSES UNIT 2 BRP: 51-2-AB-002.SI-2-AB-OO3 INSERVICE INSPECT 10N LOCATION ISOMETRIC 2PPROVAL: [Mgyj,Mgy 9 /- h FLOW: u2-0262. u2-0263 TCx-2-2583 lREv.2 l 09-01-94 T r x,L 58 3.>. i 5 : ~,. m-,, s-s- wr

N v t V REFUELING WATER STORAGE' 80-CT-2-028 s. - 2 3 t 9 8 80 FLOW y RESTRICTO 82 a + BO-C I-2-O n F -~,, 40 \\ g3 25 4 N 3 31 . e e. zu % i' 3,, 3* 3' or 32 , 55 is , 35 as j 3 , x, _g. 20 y 3po 2' 23 24 a taustaatavE USE MV NOTES: 6* AND 10* SCH 40 PIPtNG 15 INCLUDED FOR DESCRIPT ION: CONTAINMENT SPRAY POPULATION ONLY. T/5CH: (10*).365*/40.(6*).280 7 40 CPSES UNIT 2-INSERVICE-INSPECT 10N Bne: ci-2-se-023. cT-2-se-os3. cT-2-vo- . LOCATION ISOMETRIC. k ,gg [. /. [y FLOW: M2-0232 TCX-2-2584 lREv.1 l 09-01-94 GPPROVAL: yf T C y 225841.t 51 f m m=.

t - ~ - t 2ct-ooso 4 34 3 2 i 22h4 39 to-ct-2-oif 83 y .2 / wr. 2-2ssef g" 22sil \\ 29 34 to 22 's is. 7 > 2s M /is 21 2 JA -l 2' m so ,-- so-ct oss 35 3' is 3 l 3 34 4t.tustslaisvE USE MY j NOTES: 10*SCH 40 PIPING 15 INCLUDED FOR DESCRIPT ION: CONTAINMENT SPRAY POPULATION ONLY. T/SCH: E 10*).365*/ 40 CPSES UNIT 2 BRP CT-2-SB-037.CT-2-SB-038.CT-2-SB-039.~ INSERVICE INSPECT 10N CT-2-SB-042 .LOCAT10N ISOMETRIC APPROVAL: M//[4g M //[ g 7.[ W FLOW: M2-0232 TCX-2-2585 lREv. I l O?-01-94 V ' TC)2258' l.tS i m___-_.m__.m. __m _____.___.m_. .___2-m.

-W -F -~~-- - ~ - 2s 2s E-C T 056T 24 21 28 23 22 St. 2 32'- 20 ,h 2Si3 ~T 3' ss s lno' N zUdisf' 't se s '3 8 so-cr-2-oss, 9 eo 32 It OLLUSTRat tWE USE Opti NOTES: 6* AND 10* SCH 40 PIPING IS INCLUDED FOR DESCRIPT ION: CONTAINuENT SPRAY POPULATION ONLY. T/SCH: t 10*).365*/40. 46*).280*/40 CPSES UNIT 2 BRP: C T-2-SB-Ol9 CT-2-SB-035. CT-2-SB-037 INSERVICE INSPECTION LOCATION ISOMETRIC CT-2-Se-o44 APEROvat: [$hg [gg [. /-f$ FLOW: M2-0232 TCX-2-2586-lREv.1 l 09-01-94 T C C25861.ls t I '/ m. u ~w. .e--

==

WN N j g Y t _ _,.,,. - - -.. - _ _ ~ _ _.

  • 3eS O

^N -s o t O 8 0I$(NARCE I _. / U \\ / o o) /..., .z., t i suusinativt ust outt TU ELECTRIC NOTES:

  • PUMP DESIGNATION PRECEDES ITEM DESCRIPTION: RHR PUMPS I & 2 iotnTiricArion.

-CPSES UNIT 2 INSERVICE INSPECTION LOCATION ISOMETRIC APPROVAL: [8 cn /[ N/ rh TCX-2-3100 lREv.t l 03-01-94 / .J TC C31001.iS t - ~.u.- --e, --e-w .--,.e e-a e a e s

.%.W \\n V l / -\\ m _ u '~'- - >' u 7 4 /l> L i / ? / l l l / / l / / / / l ,,'y" I east SUPPORTS es E SiOE OF PUMP l sttustnativt ust outv NOTES: + PUMP DESIGNATION PRECEDES ITEM DESCRIPTION: CS CHARGING PUMPS I & - 2 TU. ELECTRIC iocNTir iCATioN CPSES UNIT 2- -lNSERVICE INSPECT 10N' LOCATION ISOMETRIC TCX-2-3130 lREV. t l 09-01-94~ f f M,j g ga, f-g fy APPROVAL: T C C 5 8 tot.is t ./_-.____. T e ..,, ~,,,, www-..w-ww.. ,.-*-w,, ,-,wvw v =w w.- + -... * -,, - -. ~ .--,m-w=i y.wr- ,..w. ,. -w.-*,,-w-r.,-w .v.,,.-. w. -u, 3-n

%W' L 4 ei- - es eis g sis / 1 [ [" N 'O000d00000000000 OO ~~ 835 O rOO - en O, ,3. / 0000000000000000 ' - e3. l ? n es: L esi ezo 1 L sir ~ N i 7 i I i I I \\ / l-l- l I / T .\\ /// SaSE SUPPORTS ettusinaf twt ust (My NOTES: PUMP DESIGNATION PRECEDES ITEM - DESCRIPT ION: SAFETY INJECTION PUMPS I & - 2 ~ [ IDENTIFICATION.833 THRU B38 DO NOT REQUIRE 32 - 2.125' DI A. (BI-THRU B32). EXAMINATION AND ARE SHOWN HERE FOR LOCATION 6 - 1.5* DI A. tB33 THRU B38) DCEC ll 1T ""). 1 JL J LJ l l ( REFERENCE ONLY. INSERVICE INSPECTION LOCATION ISOMETRIC ' TC X-2-3140 lREv.t l 09-0I-94 APPROVAL: %8 gqya [m [_ / ff/ f ^ _ff 40' ' S ' . ~..... .....}}