MONTHYEARML20211H9651997-10-0101 October 1997 Annual Operating Rept for Kansas State Univ Triga Mark II Nuclear Reactor Facility for Period 961001-970930 ML20078A2291995-01-12012 January 1995 Changes in Facility,Procedures & Tests & Experiments for Period 931001-940930,per 10CFR50.59(b) ML20059D0341993-10-26026 October 1993 Changes in Facility,Procedures & Tests & Experiements for Period 921001-930930,per 10CFR50.59(b) ML20118D1711992-10-0202 October 1992 Annual Rept for Kansas State Univ Triga Mk II Nuclear Facility for Oct 1991 Through Sept 1992 ML20085D5311991-10-0404 October 1991 Annual Operating Rept for Kansas State Univ Triga Mark II Nuclear Reactor Facility for Oct 1990 to Sept 1991 ML20058B8101990-10-0909 October 1990 Submits Annual Rept for Oct 1989 - Sept 1990.Procedure 21 Re Alpha Particle Assay of Reactor Liquids Revised ML19325C7861989-10-0909 October 1989 Operating Rept for Oct 1988 - Sept 1989 ML20205L2581988-10-25025 October 1988 Submits Changes to Facility & Procedures for Oct 1987 to Sept 1988 ML20235Y5371987-10-16016 October 1987 Annual Operating Rept for Oct 1986 - Sept 1987 ML20211B3351986-10-0606 October 1986 Annual Operating Rept Fo Triga Mark II Nuclear Reactor Facility for Oct 1985 - Sept 1986 ML20133H4771985-10-0707 October 1985 Annual Rept of Changes in Facility,Procedures & Experiments, Oct 1984 - Sept 1985 ML20093K1161984-10-0303 October 1984 Annual Operating Rept,Oct 1983 - Sept 1984 ML20085J3761983-10-0707 October 1983 Annual Operating Rept for Oct 1982 - Sept 1983 ML20069H0741982-10-11011 October 1982 Submits List of Facility Procedure Changes,Tests & Experiments for Oct 1981-Sept 1982,per 10CFR50.59(b) 1997-10-01
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217N7471999-10-18018 October 1999 Ro:On 990923,overpower Operation.Caused by Malfunction in Percent Power Channel.Channel Repaired & Returned to Service on 991007 ML20198K8331998-12-21021 December 1998 Safety Evaluation Supporting Amend 12 to License R-88 ML20155C5421998-10-28028 October 1998 Safety Evaluation Supporting Amend 11 to License R-88 ML20211H9651997-10-0101 October 1997 Annual Operating Rept for Kansas State Univ Triga Mark II Nuclear Reactor Facility for Period 961001-970930 ML20134F1421996-10-30030 October 1996 Safety Evaluation Supporting Amend 10 to License R-88 ML20078A2291995-01-12012 January 1995 Changes in Facility,Procedures & Tests & Experiments for Period 931001-940930,per 10CFR50.59(b) ML20059D0341993-10-26026 October 1993 Changes in Facility,Procedures & Tests & Experiements for Period 921001-930930,per 10CFR50.59(b) ML20118D1711992-10-0202 October 1992 Annual Rept for Kansas State Univ Triga Mk II Nuclear Facility for Oct 1991 Through Sept 1992 ML20085D5311991-10-0404 October 1991 Annual Operating Rept for Kansas State Univ Triga Mark II Nuclear Reactor Facility for Oct 1990 to Sept 1991 ML20058B8101990-10-0909 October 1990 Submits Annual Rept for Oct 1989 - Sept 1990.Procedure 21 Re Alpha Particle Assay of Reactor Liquids Revised ML19325C7861989-10-0909 October 1989 Operating Rept for Oct 1988 - Sept 1989 ML20236B8831989-03-0202 March 1989 Ro:On 890301,as Second to Two Std Control Rods Being Withdrawn,Other Two Rods Automatically Scrammed.Caused by Frayed Wires on Rod Drive Mechanism Resulting in Short Circuit.Electromagnetic Assembly May Be Replaced ML20205L2581988-10-25025 October 1988 Submits Changes to Facility & Procedures for Oct 1987 to Sept 1988 ML20235Y5371987-10-16016 October 1987 Annual Operating Rept for Oct 1986 - Sept 1987 ML20213G9331986-10-30030 October 1986 Ro:On 861028,while Performing Routine Monthly Surveillance Tests,Alarm Condition in Circuit Activated Visual Annunciation at Police Dept Indicator Panel But Failed to Activate Audible Annunciation.Caused by Dirty Contacts ML20211B3351986-10-0606 October 1986 Annual Operating Rept Fo Triga Mark II Nuclear Reactor Facility for Oct 1985 - Sept 1986 ML20133H4771985-10-0707 October 1985 Annual Rept of Changes in Facility,Procedures & Experiments, Oct 1984 - Sept 1985 ML20129E7121985-05-23023 May 1985 Ro:On 850522,reactor Operated W/O Continuous Air Monitor Operating.Caused by Monitor Being Manually Switched Off Before Reactor Startup.Breaker Reset ML20093K1161984-10-0303 October 1984 Annual Operating Rept,Oct 1983 - Sept 1984 ML20085J3761983-10-0707 October 1983 Annual Operating Rept for Oct 1982 - Sept 1983 ML20069H0741982-10-11011 October 1982 Submits List of Facility Procedure Changes,Tests & Experiments for Oct 1981-Sept 1982,per 10CFR50.59(b) 1999-10-18
[Table view] |
Text
[ < ....
Department of Nuclear Engineering N Ward Hall M Manhattan, Kansas 66506-2503 turvaster2T 913-532-5624 12 January 1995 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 Re: Docket 50-188 License R-88 Gentlemen:
Pursuant to 10CFR50.59(b) the following items are submitted for the Kansas State University TRIGA Mk.11 Nuclear Reactor Facility for the period 1 Oct 1993 through 30 aep 1994.
A. Changes in the Facility
- 1. At their meeting on 23 Feb 1994, the Reactor Safeguards Committee approved the instrumentation changes listed below. Verification and functional performance procedures were presented by Reactor Facility Staff and approved by the Committee with the fmding that the proposed actions involved no unreviewed safety questions and posed no threats to the health and safety of workers and the public, and to the integrity of the reactor,
- a. Replace existing percent power channel with General Atomic NPP-1000 Analog Pulse / Safety Channel.
- b. Replace existing linear power channel with General Atomic NMP-1000 Analog Linear Power Channel.
- c. Replace existing log-count-rate and log-current channels with General l Atomic NLW-1000 Wide Range Log Channel. i
- d. Replace existing Tracor strip chart recorder with Soltec Model 3310 Multi-Pen Strip Chart Recorder. 4 B. Changes in Procedures j
- 1. A new Radiation Protection Program, approved by the Reactor Safeguards Committee on 29 Sep 1993 was implemented effective 1 Jan 1994.
n er u , o o :ar 9501240324 950112 4 O L d0 l
PDR ADOCK 05000188 (
R PDR
I (J.S. Nuclear Regulatory Commission Page 2 12 January 1995
- 2. Associated with the aforementioned instrumentation changes were minor changes in the following procedures. These were approved by the Reactor Safeguards Committee on 16 June 1994, with the finding that the changes consisted of nomenclature changes and increases in surveillance requirements, and involved no unreviewed safety questions.
- a. Proc: dure 7: Semi-annual $1.00 comparison pulse
- b. Procedure 12: Functional performance check of transient rod
- c. Procedure 15: TRIGA Mkil reactor startup
- 3. On 16 June 1994, the Reactor Safeguards Committee approved changes in Procedure 17:
Periodic nuclear intrusion alarm testing. The changes involved increasing the frequency oftesting.
C. Changes in Tests and Experiments
- 1. Associated with the aforementioned instrumentation changes were minor changes in Experiment 23: Pulsed operations. The revised experiment was approved by the Reactor Safeguards Committee on 16 June 1994, with the finding that the changes consisted of nomenclature changes and increases in surveillance requirements, and involved no unreviewed safety questions.
Sincerely, lLL6lwd SW Richard E. Faw, Director KSU Nuclear Reactor Facility cc: U.S. Nuclear Regulatory Commission, Region IV KSU Nuclear Reactor Safeguards Committee