UNIVERSITY OF VIRGINIA SCHOOL OF ENGINEERING AND APPLIED SCIENCE C H AR LOTTESVILLE. 22805

~

CEPARTMENT OF NUCLEAR ENGIN EERIN G AND ENGIN EERING PHYSICS T ELEP HON E:

804-924-7130 CEACTOR FACILITY September 12, 1983 Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Attn:

Mr. Cecil 0. Thomas, Chief Standardization and Special Projects Branch Re: Docket No. 50-396 License No. R-123

Dear Mr. Thomas:

This is in reference to our letter of May 10, 1983 requesting a change to the CAVALIER Technical Specifications.

We would like to add the following sentence to Section 5.1 on the specifications of the reactor fuel.

An experimental element in which individual fuel plates can be removed or inserted may also be used.

The following additional information is also being supplied at the request of Mr. R.E. Carter of your office concerning Section 3.2.B. of the Technical Specifications.

The present core configuration on the CAVALIER is a 4 x 4 array of fuel with the control rods at the four corners.

The control rods are worth approximately 0.75% Ak/k each in this configuration. The shutdown margin with one rod withdrawn is 1.53% Ak/k and the excess reactivity is 0.60% Ak/k.

Sincerely, h

J.P. Farrar, Reactor Supervisor UVA, Reactor Facility JPF:vs

0f0 Il0 0309160080 830912 PDR ADOCK 05000396 p