Text
.
i
~
DukeMerCompany T C f:dians__
McGuire Nuclear Generatton Depanment Vice herident.
12700Hagers FerryRoad(MG01\\P)
(704)8754800 llunterwille,NC280788A5 (704)8754809 Fax i
DUKEPOWER l
January 3, 1995 i!
U. S. Nuclear Regulatory Commission Document Control Desk Washington, D.C.
2 ".55
Subject:
McGuire Nuclear Station l
Unit 2 Steam Generators December 1994 EOC-9 Refueling Outage F* and 15-Day Report Pursuant to Technical Specifications 3/4.4.5.5, part a and c, the following information is submitted:
a.
The following information is submitted regarding F* tubest (The attached lists identify the F* tubes, their location, and the size of degradation.)
Staana Ganarator
&tf.achment
'l A
1 B
2 C
3 D
4 b.
The following quantitier of tubes were removed from service: (No tubes were repaired by sleeving) steam Ganarator Mo. of Tubas Pluosted j
A 199 B
209 C
184 D
210 Questions or problems should be directed to Kay Crane, Regulatory Compliance at (7041 875-4306.
Very truly yours, KM T. C. McNeekin, Vice President McGuire Nuclear Station Attachments
.)
950110000s 950103 DR ADOCK 0500o37o j
p PDR
$W i
N*' =
e 000*9***********
BWNT TUBAN II (Varsion 2.1) 12/29/1994 15:03:54 cooe***e********
McGuira Nucleor Station - Unit Two coceae**********
S/G A cocoeo.*********
12/94 RFO e***************
Bobbin,H/L Tubesheet Page 1 of 3 ATTACHMENT 1 - F*
F* QUERY TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 2
2 IDI 12 8.87 P 1 139 TE-HL
+10.01 9TH TSP Bobbin 2 60 IDI 55 6.97 P 1 17 TE-HL
+11.29 9TH TSP Bobbin 2 66 IDI 44 7.25 P 1 98 TE-HL
+4.96 9TH TSP Bobbin 2 74 IDI 45 12.84 P 1 14 TE-HL
+10.18 9TH TSP Bobbin 3 13 IDI 82 9.72 P 1 67 TE-HL
+4.09 9TH TSP Bobbin 3 16 IDI 86 22.99 P 1 61 TE-HL
+15.85 9TH TSP Bobbin 3 21 IDI 44 16.11 P 1 16 TE-HL
+1.24 9TH TSP Bobbin 3 22 IDI 24 4.54 P 1 132 TE-HL
+16.70 9TH TSP H/L Tubesheet SAI 3.25 1 44 TTS-HL
~4.12 TTS-HL Bobbin 4 51 IDI 22 3.87 P 1 135 TE-HL
+9.47 9TH TSP H/L Tubesheet 4 60 MAI 0.83 1 136 TTS-HL
-4.97 TTS-HL Bobbin 4 62 IDI 60 7.34 P 1 18 TE-HL
+16.70 9TH TSP H/L Tubesheet SAI 2.54 1 35 TTS-HL
-3.91 TTS-HL i
Bobbin 4 83 IDI 97 24.97 P 1 34 TE-HL
+2.86 9TH TSP i
Bobbin 5 19 IDI 9
5.93 P 1 148 TE-HL
+11.69 9TH TSP Bobbin 5 60 IDI 43 5.45 P 1 13 TE-HL
+7.06 9TH TSP Bobbin 6 12 IDI 19 2.18 P 1 127 TE-HL
+16.53 F/L Bobbin 6 18 IDI 79 6.96 P 1 72 TE-HL
+7.44 F/L Bobbin 6 19 NQI 7.00 P 1 161 TE-HL
+9.35 F/L Bobbin IDI 50 2.69 P 1 105 TE-HL
+16.19 F/L Bobbin 6 28 IDI 85 15.45 P 1 63 TE-HL
+11.67 F/L H/L Tubesheet 6 62 SAI 0.50 1 16 TTS-HL
-2.51 TTS-HL Bobbin 6 84 NQI 31.58 P 1 167 TE-HL
+13.47 F/L Bobbin 7 12 IDI 98 33.87 P 1 38 TE-HL
+3.01 F/L Bobbin 8 55 IDI 55 14.20 P 1 17 TE-HL
+11.26 F/L Bobbin 8 59 IDI 89 40.39 P 1 52 TE-HL
+5.49 F/L Bobbin 9 105 IDI 92 13.42 P 1 47 TE-HL
+7.32 F/L Bobbin 11 4 IDI 58 11.43 P 1 19 TE-HL
+8.60 F/L Bobbin 11 59 IDI 13 3.46 P 1 129 TE-HL
+17.02 F/L Bobbin 11 72 NQI 4.86 P 1 142 TE-HL
+10.39 F/L Bobbin NQI 7.37 P 1 124 TE-HL
+13.24 F/L Bobbin 12 13 IDI 58 12.15 P 1 19 TE-HL
+4.86 F/L Bobbin 12 35 IDI 64 28.81 P 1 21 TE-HL
+4.48 F/L H/L Tubesheet PRM 4.34 1 43 TTS-HL
-4.01 TTS-HL Bobbin 12 36 IDI 67 10.76 P 1 22 TE-HL
+13.37 F/L Bobbin 12 62 IDI 86 15.07 P 1 24 TE-HL
+11.44 F/L Bobbin 13 13 IDI 91 10.72 P 1 51 TE-HL
+15.00 F/L Bobbin 13 25 IDI 55 9.90 P 1 17 TE-HL
+15.77 F/L H/L Tubesheet 13 110 SAI 0.77 1 111 TTS-HL
-3.47 TTS-HL Bobbin 14 19 IDI 74 5.30 P 1 23 TE-HL
+17.27 F/L I
Bobbin 14 24 IDI 54 10.90 P 1 19 TE-HL
+3.57 F/L Bobbin 14 59 IDI 48 9.14 P 1 15 TE-HL
+12.26 F/L Bobbin 15 45 IDI 83 19.51 P 1 29 TE-HL
+17.18 F/L H/L Tubesheet MAI 6.82 1 30 TTS-HL
-4.64 TTS-HL Bobbin 15 50 IDI 66 12.63 P 1 23 TE-HL
+10.61 F/L Bobbin 15 67 IDI 94 35.37 P 1 35 TE-HL
+10.23 F/L Bobbin 15 72 IDI 61 20.55 P 1 20 TE-HL
+7.90 F/L Bobbin 15 105 IDI 64 11.36 P 1 21 TE-HL
+6.93 F/L Bobbin 16 9 IDI 54 13.44 P1 19 TE-HL
+13.42 F/L Bobbin 16 11 IDI 40 11.33 P 1 14 TE-HL
+11.47 F/L Bobbin 16 29 IDI 63 14.48 P 1 22 TE-HL
+13.40 F/L Bobbin 17 24 IDI 57 22.52 P 1 16 TE-HL
+10.56 F/L Bobbin IDI 96 25.64 P 1 27 TE-HL
+14.38 F/L Bobbin 17 25 IDI 79 19.71 P 1 22 TE-HL
+14.36 F/L Bobbin 17 31 IDI 43 19.70 P 1 12 TE-HL
+9.66 F/L Bobbin IDI 46 14.53 P 1 13 TE-HL
+16.35 F/L Bobbin 17 48 IDI 83 8.65 P 1 62 TE-HL
+16.68 F/L H/L Tubesheet MAI 5.21 1 34 TTS-HL
-4.97 TTS-HL Bobbin 18 15 IDI 57 15.08 P 1 16 TE-HL
+5.64 F/L Bobbin 19 21 IDI 53 15.64 P 1 17 TE-HL
+0.38 F/L Bobbin 19 22 IDI 53 14.00 P 1 17 TEdHL
+4.79 F/L Bobbin 19 29 IDI 38 13.90 P 1 12 TE-HL
+13.37 F/L Bobbin IDI 47 17.77 P 1 15 TE-HL
+14.41 F/L Bobbin 19 59 NQI 6.86 P 1 142 TE-HL
+15.99 F/L Bobbin 20 28 IDI 67 8.37 P 1 85 TE-HL
+14.43 F/L
[4
'l i
- t***********
BWNT TURAN II (Version 2,1).
12/29/1994 15:03:54 McGuire Nuclear Station - Unit Two-s/a A e***************
12/94 RFO' Bobbin,H/L Tubesheet'
'i t
Page 2 of 3
, p,
'F*< QUERY
-TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 20 87 IDI 94 1.79 P 1 46 TE-HL
+12.83 F/L Bobbin 21 58 IDI 54 9.77 P 1 97 TE-HL
+6.96 F/L' Bobbin IDI '94 16.23 P 1 44 TE-HL
+7.61
-F/L H/L Tubesheet 21 98 SAI 3.05 1 22 TTS-HL.
-2.91 TTS-HL i
Bobbin 22 23 NQI 6.45 P 1 158 TE-HL
+16.06 F/L Bobbin 22 55 IDI 87 21.72 P 1 56 TE-HL
+15.19 F/L Bobbin 23 7 IDI 15 8.39 P 1 126 TE-HL
+6.21 F/L Bobbin 23 24 IDI 86 22.46 P 1 58 TE-HL
+16.87 F/L H/L Tubenheet MAI 6.11 1 39 TTS-HL
-4.96 TTS-HL Bobbin 23 29 IDI 53 ~10.94 P 1 99 TE-HL
+7.33 F/L.
Bobbin 24 14 IDI 56 8.73 P 1 97 TE-HL
+13.14 F/L Bobbin 24 22 IDI 56 7.86 P 1 97 TE-HL
+14.97 F/L-Bobbin 24 25 IDI 27 10.63 P 1 119 TE-HL
+16.85 F/L H/L Tubesheet SAI 7.96 1 19 TTS-HL
-4.25 TTS-HL Bobbin 24 36 IDI 77 15.80 P 1 73 TE-HL
+15.91 F/L H/L Tubesheet 24 49 SAI 0.79 1 50 TTS-HL
-4.17 TTS-HL Bobbin 25 13 IDI 71 9.74 P 1 81 TE-HL
+2.80 F/L
{
H/L Tubenheet 25 29 SAI 2.48 1 19 TTS-HL
-4.22 TTS-HL Bobbin 25 55 IDI 20 6.27 P 1 123 TE-HL
+9.42 F/L Bobbin 25 63 NOI 6.57 P 1 155 TE-HL
+7.69 F/L Bobbin 26 12 NQI 7.37 P 1 166 TE-HL
+16.17 F/L H/L Tubesheet SAI 4.95 1 20 TTS-HL
-5.81 TTS-HL Bobbin 27 28 IDI 71 4.69 P 1 82 TE-HL
+9.32 F/L Bobbin 27 39 IDI 78 23.17 P 1 28 TE-HL
+1.71 F/L Bobbin 27 52 IDI 68 10.13 P 1 85 TE-HL
+5.48 F/L Bobbin 27 58 IDI 95 30.85 P 1 46 TE-HL
+1.35 F/L Bobbin 27 61 IDI 64 6.01 P 1 92 TE-HL
+9.18 F/L Bobbin IDI 67 6.18 P 1 89 TE-HL
+5.33 F/L Bobbin IDI 79 24.67 P 1 74 TE-HL
+8.24 F/L Bobbin 28 13 IDI 42 9.74 P 1 105 TE-HL
+10.42 F/L Bobbin 28 31 NOI 7.46 P 1 161 TE-HL
+3.63 F/L Bobbin 29 25 IDI 35 14.11 P 1 12 TE-HL
+15.16 F/L Bobbin 29 38 IDI 18 1.75 P 1 124 TE-HL
+12.74 F/L H/L Tubesheet 30 23 VOL 0.51 1 41 TTS-HL
-4.71 TTS-HL Lobbin 31 27 IDI 64 11.54 P 1 23 TE-HL
+10.41 F/L Bobbin 32 20 NQI 4.95 P 1 145 TE-HL
+16.86 F/L H/L Tubesheet MAI 6.44 1 23 TTS-HL
-4.43 TTS-HL Bobbin 32 30 IDI 53 11.41 P 1 19 TE-HL
+14.34 F/L Bobbin 32 35 ILI 86 13.35 P 1 57 TE-HL
+16.87 F/L Bobbin IDI 92 85.14 P 1 46 TE-HL
+14.83 F/L H/L Tubesheet MAI 10.42 1 38 TTS-HL
-4.64 TTS-HL 1
Bobbin 33 77 NOI 6.98 P 1 140 TE-HL
+12.12 F/L Bobbin 34 29 IDI 72 10.19 P 1 23 TE-HL
+5.13 F/L Bobbin 35 49 IDI 44 5.77 P 1 103 TE-HL
+7.22 F/L Bobbin 35 72 IDI 67 11.15 P 1 87 TE-HL
+11.92 F/L Bobbin 36 44 IDI 95 6.68 P 3 39 TE-HL
+17.84 F/L H/L Tubesheet SAI 9.96 1 31 TTS-HL
-3.52 TTS-HL Bobbin 36 63 IDI 72 12.56 P 1 80 TE-HL
+15.08 F/L H/L Tubenheet 36 94 PRM 4.11 1 50 TTS-HL
+4.19 TTS-HL i
Bobbin 37 45 IDI 59 11.96 P 1 17 TE-HL
+12.36 F/L Bobbin 38 35 IDI 81 16.38 P 1 68 TE-HL
+11.19 F/L Bobbin 38 45 NQI 11.69 P 1 163 TE-HL
+7.29 F/L Bobbin IDI 82 12.33 P 1 28 TE-HL
+10.32 F/L Bobbin IDI 99 22.05 P 1 36 TE-HL
+9.23 F/L H/L Tubesheet 38 46 SAI 0.32 1 37 TTS-HL
-4.71 TTS-HL Bobbin 38 52 NOI 8.56 P 1 164 TE-HL
+12.83 F/L Bobbin 38 57 IDI 90 16.47 P 1 53 TE-HL
+14.11 F/L Bobbin 38 63 IDI 31 14.75 P 1 13 TE-HL
+8.70 F/L Bobbin 38 76 IDI 29 5.85 P 1 116 TE-HL
+14.69 F/L i
Bobbin 38 91 IDI 41 9.49 P 1 108 TE-HL
+7.15 F/L Bobbin IDI 55 5.21 P 1 97 TE-HL
+2.45 F/L Bobbin IDI 74 13.46 P 1 77 TE-HL
+11.12 F/L Bobbin 39 32 IDI 91 28.70 P 1 52 TE-HL
+11.37 F/L Bobbin 39 36 NQI 5.71 P 1 25 TE-HL
+5.91 F/L Bobbin IDI 62 7.45 P 1 89 TE-HL
+3.62 F/L
-i -
~
- ?***********
BWNT TUBAN II (Varsion 2'1) 12/29/1994 15:03:54 1
McGuire Nuclear Station - Unit Two
- e**************
g/g A I
12/94 RFO-Bobbin,H/L Tubesheet
]
Page 3 of 3 I
. ATTACHMENT 1 - F*
i F* QUERY i
TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1
-Bobbin 39 57 IDI 75 4.73 P 1 76 TE-HL
+9.42
'F/L Bobbin 40 63 IDI 76 11.21 P 1 26 TE-HL
+15.33 F/L Bobbin 41 75 ODI 91 9.52 P 1 31 TE-HL
+6.53 F/L Bobbin 41 88 IDI 79 12.95 P 1 27 TE-HL
+13.23 FJ'1 l
Bobbin 42 76 IDI 86 8.23 P 1 32 TE-HL
+7.85 F/L Bobbin 44 57 IDI 90 37.15 P 1 50 TE-ML
+14.05 F/L Bobbin 44 61 IDI 70 13.65 P 1 26 TE-HL
+10.21 F/L Bobbin IDI 72 24.38 P 1 81 TE-HL
+8.33 F/L Bobbin 44 63 IDI 73 21.34.P 1 27 TE-HL
+7.59 F/L Bobbin 45-31 IDI 33 10.35 P 1 10 TE-HL
+17.17 ~
F/L-Bobbin 45 51 IDI 94-64.19 P 1 42 TE-HL
+14.38 F/L 11.17 P 1 20 TE-HL
+7.57 F/L Bobbin 47 57 NQI.63 16.01 P 1 22 TE-HL
+4.80 F/L
~
Bobbin 49 71 IDI Total Indications Found - 143 l
Total Tubes Found = 117 r
Total Tubes in Input File = 117 l
i i
E a
E 4
4 i
s.
BWNT.TUBAN II (Vorsion 2.1) 12/29/1994 14:40:46 McGuire Nuclear Station - Unit Two S/G B i
48**************
12/94 RFO
- x*****
Bobbin,H/L Tubesheet J
Page 1 of 2 ATTACHMENT 2 - F*
F*-QUERY-t TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 2 46 IDI 40 12.05.P 1 24 TE-HL
+12.27 9TH TSP Bobbin 4 37 IDI 50 15.76 P 1 18 TE-HL
+3.71 9TH TSP Bobbin 4 73 IDI 50 11.87 P 1 15 TE-HL
+15.07 9TH TSP Bobbin 5 42 IDI 33 10.50 P 1 12 TE-HL
+17.53 9TH TSP H/L Tubesheet MAI 0.52 1 24 TTS-HL
-3.09 TTS-HL
~ Bobbin 5 70 IDI 98 27.30 P 1 53 TE-HL
+4.10 9TH TSP H/L Tubesheet SAI 0.26 1 25 TTS-HL
+0.00 TTS-HL Bobbin 5 113 IDI 27 8.18 P 1 10 TE-HL
+15.95 9TH TSP Bobbin 6 69 IDI 58 8.86 P 1 19 TE-HL
+8.81 F/L Bobbin 6 70 IDI 67 13.55 P 1 22 TE-HL
+7.63' F/L Bobbin 6 77 IDI 45 10.10 P 1 15 TE-HL
+6.59 F/L I
Bobbin 7 56 NQI 13.62 P 1 168 TE-HL
+12.20 F/L Bobbin 7 94 IDI 42 7.27 P 1 106 TE-HL
+11.29 F/L Bobbin IDI 50 7.58 P 1 16 TE-HL
+12.49 F/L 4
Bobbin 7 97 IDI 73 15.59 P 1 24 TE-HL
+3.04 F/L
' Bobbin 8 104 NOI 10.70 P 1 155 TE-HL
+7.60 F/L Bobbin 9 108 IDI 57 14.13 P 1 78 TE-HL
+14.92 F/L Bobbin 10 59 IDI 94 42.65 P 1 31 TE-HL
+12.34 F/L H/L Tubesheet SAI 1.06 1 15 TTS-HL
+0.00 TTS-HL Bobbin 10 67 IDI 99 10.40 P 1 25 TE-HL
+2.81 F/L Bobbin 11 48 IDI 65 13.86 P 1 84 TE-HL
+4.65 F/L Bobbin 11 58 IDI 56 6.75 P 1 18 TE-HL
+16.13 F/L Bobbin 11 70 NQI 7.16 P 1 161 TE-HL
+16.84 F/L H/L Tubesheet MAI 3.13 1 21 TTS-HL
-4.39 TTS-HL Bobbin 11 77 IDI 69 14.01 P 1 82 TE-HL
+10.12 F/L
[
Bobbin 12 75 IDI 64 11.98 P 1 88 TE-HL
+9.26 F/L Bobbin 12 112 IDI 48 20.54 P 1 106 TE-HL
+15.75 F/L Bobbin 13 38 NOI 1.86 P 1 126 TE-HL
+12.19 F/L Bobbin 13 96 IDI 61 10.27 P 1 92 TE-HL
+6.32 F/L Bobbin IDI 71 24.33 P 1 80 TE-HL
+9.04 F/L H/L Tubesheet SAI 0.71 1 37 TTS-HL
+0.00 TTS-HL Bobbin 14 14 IDI 42 7.16 P 1 18 TE-HL
+18.40 F/L Bobbin 14 44 IDI 40 11.25 P 1 165 TE-HL
+16.58 F/L Bobbin 15 64 IDI 84 12.82 P 1 31 TE-HL
+18.26 F/L H/L Tubesheet MAI 2.39 1 33 TTS-HL
-3.48 TTS-HL Bobbin 16 57 IDI 42 8.82 P 1 14 TE-HL
+4.87 F/L i
Bobbin 16 59 IDI 68 17.32 P 1 25 TE-HL
+8.94 F/L Bobbin 16 76 IDI 70 11.35 P 1 26 TE.HL
+6.69 F/L
[
Bobbin 16 97 IDI 67 10.35 P 1 22 TE-HL
+3.01 F/L Bobbin 17 61 IDI 24 16.58 P 1 6 TE-HL
+10.14 F/L Bobbin 17 74 IDI 78 6.08 P 1 56 TE-HL
+16.98 F/L Bobbin 17 109 IDI 21 6.01 P 1 126 TE-HL
+13.93 F/L i
Bobbin 18 71 IDI 48 11.74 P 1 12 TE-HL
+17.33 F/L H/L Tubesheet MAI 7.66 1 32 TTS-HL
-4.51 TTS-HL v
Bcbbin 18 103 IDI 79 21.66 P 1 55 TE-HL
+18.06 F/L t
H/L Tubesheet MAI 9.78 1 30 TTS-HL
-3.72 TTS-HL L
Bobbin 19 23 NOI 2.66 P 1 93 TE-HL
+11.19 F/L Bobbin 20 75 IDI 96 37.10 P 1 39 TE-HL
+2.23 F/L Bobbin 20 81 IDI 50 4.29 P 1 97 TE-HL
+13.67 F/L Bobbin 20 95 IDI 61 27.98 P 1 20 TE-HL
+7.01 F/L Bobbin 21 52 IDI 93 21.37 P 1 41 TE-HL
+2.55 F/L i
Bobbin 21 74 IDI 81 31.58 P 1 30 TE-HL
+16.26 F/b Bobbin 23 92 IDI 78 26.10 P 1 29 TE-HL
+12.70 F/L l
Bobbin 26 27 NQI 2.16 P 1 158 TE-HL
+15.39 F/L Bobbin 27 69 IDI 89 8.83 P 1 34 TE-HL
+7.75 F/L Bobbin IDI 92 10.70 P 1 35 TE-HL
+8.77 F/L Bobbin 27 101 IDI 70 12.02 P 1 19 TE-HL
+15.70 F/L i
Bobbin 28 93 IDI 51 11.01 P 1 19 TE-HL
+8.31 F/L l
Bobbin 28 100 NQI 20.72 P 1 9 TE-HL
+13.68 F/L
{
Bobbin 29 96 IDI 43 8.48 P 1 16 TE-HL
+3.01 F/L I
Bobbin 30 77 IDI 77 14.85 P 1 66 TE-HL
+13.46 F/L Bobbin 30 78 IDI 88 42.31 P 1 51 TE-HL
+13.22 F/L Bobbin 34 80 IDI 73 10.57 F 1 22 TE-HL
+7.26 F/L Bobbin IDI 94 42.05 P 1 39 TE-HL
+9.04 F/L Bobbin 36 25 NQI 2.73 P 1 59 TE-HL
+17.44 F/L
y___.
?
l BWNT TUBAN II (Version 2.1)'
.12/29/1994 14:40:46
.eee*************
McGuire Nuclear Station'- Unit Two l
eee*************
S/G B e***************
12/94 RFO i
Bobbin,H/L Tubesheet l
t Page 2.of 2' ATTACHMENT;2.
F*
l F* QUERY--
TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 36 92'IDI 68 9.01 P 1 19 TE-HL
+8.92 F/L Pobbin 3B 91 IDI 1
5.57 P 1 131 TE-HL
+13.30 F/L Bobbin 38':95 IDI
- 57. 21.41 P 1 16 TE-HL
+11.17 F/L
'j Bobbin 43 71 IDI 45 11.38 P 1 19 TE-HL
+9.70 F/L E
Total-Indications Found = 69 i
Total. Tubes Found = 57 Total Tubes in Input File =.57 5
I t
~
a F
A I
- i a
i i
4 e
t I
-l l
l l
i
r c00e************
BWNT TIRJM II (Varsion 2.1) 12/29/1994 14:38:17 ee**************
McGuire Nuclear Station - Unit Two e***************
S/G C 12/94 RFO Bobbin,H/L Tubesheet ATTACHMENT 3 - F*
F* QUERY TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 2 39 IDI 94 47.17 P 1 57 TE-HL
+3.89 9TH TSP Bobbin 2 51 NQI 13.17 P 1 163 TE-HL
+0.82 9TH TSP Bobbin IDI 87 5.59 P 1 73 TE-HL
+15.37 9TH TSP H/L Tubesheet 2 76 SAI 3.01 1 28 TTS-HL
-4.27 TTS-HL Bobbin 3 14 IDI 94 6.31 P 1 56 TE-HL
+11.22 9TH TSP Bobbin 3 95 IDI 95 16.83 P 1 39 TE-HL
+5.24 9TH TSP Bobbin 4 42 NQI 9.10 P 1 144 TE-HL
+14.90 STH TSP Bobbin 4 53 IDI 99 63.05 P 1 37 TE-HL
+5.24 9TH TSP Bobbin 4 88 IDI 63 44.20 P 1 26 TE-HL
+12.05 9TH TSP Bobbin 5
6 NOI 12.10 P 1 159 TE-HL
+10.98 STH TSP Sobbin 5 26 IDI 85 15.47 P 1 78 TE-HL
+10.49 9TH TSP B0bbin 6 69 NOI 22.47 P 1 166 TE-HL
+6.34 F/L Esbbin 9 13 NOI 7.41 P 1 169 TE-h?
+14.42 F/L H/L Tubesheet 11 45 SAI 4.50 1 16 TTS-1.
-4.76 TTS-HL Bobbin 11 67 IDI 41 9.42 P 1 14 TE-HL
+12.52 F/L Bobbin 11 72 IDI 49 15.16 P 1 17 TE-HL
+16.38 F/L H/L Tubesheet MAI 1.39 1 19 TTS-HL
-5.01 TTS-HL Bobbin 12 27 IDI 61 8.71 P 1 22 TE-HL
+12.53 F/L H/L Tubesheet 12 30 MAI 1.31 1 37 TTS-HL
-4.69 TTS-HL H/L Tubesheet 12 68 MAI 4.61 1 21 TTS-HL
-3.69 TTS-HL Bobbin 13 76 IDI 50 9.02 P 1 17 TE-HL
+17.30 F/L Bobbin IDI 88 18.43 P 1 30 TE-HL
+14.42 F/L Bobbin 13 77 IDI 94 2.52 P 1 46 TE-HL
+6.36 F/L H/L Tubesheet 14 35 SAI 1.13 1 39 TTS-HL
-4.53 TTS-HL Bobbin 14 67 IDI 47 8.90 P 1 16 TE-HL
+3.96 F/L Bobbin IDI 65 13.41 P 1 22 TE-HL
+7.85 F/L Bobbin 14 71 IDI 50 9.70 P 1 17 TE-HL
+10.29 F/L Bobbin IDI 56 17.60 P 1 19 TE-HL
+16.17 F/L Bobbin IDI 79 17.50 P 1 27 TE-HL
+15.26 F/L Bobbin 14 72 IDI 53 14.66 P 1 18 TE-HL
+18.37 F/L H/L Tubesheet MAI 2.44 1 18 TTS-HL
-3.05 TTS-HL H/L Tubesheet 14 78 MAI 3.62 1 27 TTS-HL
-4.16 TTS-HL Bobbin 15 30 NCI 5.04 P 1 111 TE-HL
+11.41 F/L Bobbin 16 16 NQI 7.14 P 1 146 TE-HL
+14.27 F/L Bobbin 16 18 NQI 11.25 P 1 159 TE-HL
+11.42 F/ L Bobbin 16 66 NQI 3.29 P 1 35 TE-HL
+10.36 F/L H/L Tubesheet 17
'3 0 S AI 0.86 1 162 TTS-HL
-4.77 TTS-HL Bobbin 18 11 NOI 25.21 P 1 12 TE-HL
+7.96 F/L Bobbin 18 29 NOI 9.16 P 1 150 TE-HL
+13.87 F/L H/L Tubesheet 18 60 SAI 2.48 1 16 TTS-HL
-4.95 TTS-HL H/L Tubesheet 18 61 SAI 3.03 1 29 TTS-HL
-4.21 TTS-HL H/L Tubesheet 18 65 SAI 1.82 1 20 TTS-HL
-4.26 TTS-3L Bobbin 20 20 IDI 76 17.30 P 1 71 TE-HL
+13.52 F/L H/L Tubesheet 20 44 SAI 4.27 1 12 TTS-HL
-3.50 TTS-HL Bobbin 21 36 NOI 9.07 P 1 148 TE-HL
+14.94 F/L H/L Tubesheet SAI 1.51 1 24 TTS-HL
-3.62 TTS-HL Bobbin 23 14 NQI
(.37 P 1 142 TE-HL
+18.01 F/L H/L Tubesheet SAI
'i.85 1 23 TTS-HL
-3.19 TTS-HL Bobbin 24 58 IDI 45 22.76 P 1 14 TE-HL
+11.47 F/L Bobbin 24 81 IDI 40 6.26 P 1 160 TE-HL
+3.22 F/L Bobbin 25 22 NQI 14.59 P 1 165 TE-HL
+13.28 F/L H/L Tubesheet 25 24 SAI 1.40 1 20 TTS-HL
-4.21 TTS-HL Bobbin 26 27 IDI 88 14.06 P 1 48 TE-HL
+15.26 F/L H/L Tubesheet 26 42 SAI 2.63 1 20 TTS-HL
-3.94 TTS-HL Bobbin 29 57 IDI 92 1.41 P 1 45 TE-HL
+15.34 F/L Bobbin 32 78 IDI 58 1.88 P 1 93 TE-HL
+5.75 F/L Bobbin 34 46 IDI 86 5.74 P 1 59 TE-HL
+8.02 F/L Bobbin 37 44 IDI 67 14.46 P 1 22 TE-HL
+14.18 F/L l
Total Indications Found - 58 Total Tubes Found = 49 Total Tubes in Input File - 49
r r
.e***************
BWNT TUBAN II (Varsion 2.1) 12/29/1994 14:28:07 McGuire Nuclear Station - Unit Two s/g p 12/94 RFO Bobbin,H/L Tubesheet Page 1 of 2
..~ ATTACHMENT 4 F*
F# QUERY TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 2 61 IDI 27 6.43 P 1 118 TE-HL
+14.58 9TH TSP
-Bobbin 4 40 IDI 82 8.76 P 1 28 TE-HL
+1.56 9TH TSP Bobbin 4 61 NOI 5.78 P 1 157 TE-HL
+14.90 9TH TSP Bobbin 6 64 NQI 6.25 P 1 166 TE-HL
+16.14 F/L H/L Tubesheet SAI 2.71 1 27 TTS-HL
-5.39 TTS-HL Bobbin 6 99 ODI. 10 4.40 P 1 130 TE-HL
+16.09 F/L
' Bobbin 7 72 IDI 91 54.56 P 1 30 TE-HL
+16.88 F/L H/L Tubesheet MAI 14.61 1 33 TTS-HL
-4.53 TTS-HL Bobbin 7 81 IDI-73 38.39 P 1 24 TE-HL
+4.02 F/L Bobbin 7 83 IDI 8 13.10 P 1 129 TE-HL
+5.14 F/L Bobbin 7 94 IDI 75 7.03 P 1 69 TE-HL
+16.10 F/L H/L Tubesheet SAI 6.93 1 32 TTS-HL
-5.44 TTS-HL H/L Tubesheet 7 97 SAI 0.27 1 47 TTS-HL
-3.49 TTS-HL Bobbin 8 84 IDI 82 11.43 P 1 60 TE-HL
+7.19 F/L Bobbin 9 26 IDI 40 3.93 P 1 146 TE-HL
+5.04 F/L Bobbin 9 75 NOI 26.01 P 1 162 TE-HL
+8.93 F/L Bobbin 9 79 NQI 10.07 P 1 50 TE-HL
+13.90 F/L Bobbin NQI 23.17 P 1 161 TE-HL
+12.58 F/L Bobbin 10 82 IDI 21 20.67 P 1 120 TE-HL
+9.82 F/L Bobbin IDI 68 21.80 P 1 21 TE-HL
+13.19 F/L Bobbin 10 87 IDI 11 5.21 P 1 129 TE-HL
+17.94 F/L H/L Tubesheet MAI 3.49 1 19 TTS-HL
-3.38 TTS-HL Bobbin 11 94 NOI 1.60 P 1 48 TE-HL
+7.03 F/L Bobbin 12 88 IDI 70 2.17 P 1 68 TE-HL
+17.08 F/L H/L Tubenheet SAI 3.80 1 28 TTS-HL
-4.90 TTS-HL Bobbin 13 64 IDI 1 10.27 P 1 138 TE-HL
+16.03 F/L Bobbin 13 82 IDI 92 59.13 P 1 41 TE-HL
+5.61 F/L Bobbin 14 75 IDI 95 1.75 P 1 34 TE-HL
+10.54 F/L Bobbin 15 32 IDI 53 4.77 P 1 17 TE-HL-
+9.06 F/L Bobbin 15 37 IDI 98 3.67 P 1 37 TE-HL
+15.04 F/L Bobbin 16 92 IDI 58 7.20 P 1 15 TE-HL
+15.57 F/L Bobbin IDI 81 16.25 P 1 21 TE-HL
+8.81 F/L Bobbin 16 99 NOI 7.35 P 1 163 TE-HL
+15.08 F/L Bobbin 18 75 IDI 7
5.51 P 1 124 TE-HL
+6.49 F/L Bobbin 19 82 IDI 99 15.70 P 1 31 TE-HL
+3.75 F/L Bobbin 20 58 IDI 52 10.36 P 1 16 TE-HL
+6.86 F/L I
Bobbin 21 56 IDI 96 21.97 P 1 34 TE-HL
-+1.52 F/L i
H/L Tubesheet 22 71 SAI 1.01 1 20 TTS-HL
-5.36 TTS-HL i
Bobbin 22 77 NQI 27.65 P 1 167 TE-HL
+14.57 F/L H/L Tubesheet MAI 1.18 1 14 TTS-HL
-0.01 TTS-HL-Bobbin 23 104 IDI 97 9.36 P 1 30 TE-HL
+1.75 F/L Bobbin 25 94 IDI 42 9.00 P 1 13 TE-HL
+16.50 F/L Bobbin 26 39 IDI 97 37.29 P 1 31 TE-HL
+11.98 F/L Bobbin 26 61 IDI 70 8.72 P 1 21 TE-HL
+13.52 F/L Bobbin 26 66 IDI 95 4.62 P 1 31 TE-HL 43.71 F/L Bobbin 27 71 IDI 62 13.49 P 1 18 TE-HL
+18.30 F/L H/L Tubesheet MAI 4.80 1 16 TTS-HL
-3.25 TTS-HL Bobbin 28 70 IDI 48 9.23 P 1 15 TE-HL
+13.37
'F/L i
Bobbin IDI 76 12.09 P 1 22 TE-HL
+17.15 F/L H/L Tubesheet MAI 4.38 1 20 TTS-HL
-4.35 TTS-HL Bobbin 29 61 IDI 7
8.41 P 1 129 TE-HL
+15.02 F/L Bobbin 29 76 IDI 17 6.29 P 1 120 TE-HL
+15.91 F/L Bobbin 29 103 IDI 90 19.42 P 1 26 TE-HL
+18.35 F/L H/L Tubesheet MAI 1.42 1 39 TTS-HL
-3.13 TTS-HL Bobbin 32 59 NQI 11.60 P 1 162 TE-HL
+16.93 F/L
.j H/L Tubesheet SAI 0.39 1 21 TTS-HL
-2.04 TTS-HL H/L Tubesheet 32 74 SAI 0.47 1 41 TTS-HL
-3.16 TTS-HL Bobbin 32 77 NQI 22.01 P 1 165 TE-HL
+8.70 F/L H/L Tubesheet SCI 0.21 1 124 TTS-HL
-0.02 TTS-HL Bobbin-32 99 IDI 75 4.03 P 1 66 TE-HL
+11.01 F/L Bobbin 34 70 NOI 8.76 P 1 164 TE-HL
+13.99 F/L Bobbin 38 56 IDI 88 14.44 P 1 52 TE-HL
+16.08 F/L Bobbin 39 91 NQI 2.55 P 1 150 TE-HL
+15.08 F/L Bobbin 40 79 IDI 72 3.09 P 1 26 TE-HL
+13.59 F/L Bobbin IDI 99 12.26 P 1 38 TE-HL
+17.33 F/L
._.,.4,
.e BWNT TUBAN II (Varsion 2.1) 12/29/1994 14:28:07 McGuire Nuclear Station - Unit Two s/g p 12/94 RFO Bobbin,H/L Tubesheet i"
ATTACHMENT 4
- - F*
F* QUERY TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 r
Bobbin 42 49 IDI 92-1.72 P 1 48 TE-HL
+14.65 F/L-Bobbin 42 71 IDI 91 3.48 P 1 32 TE-HL
+11.60 F/L Bobbin 42 73 IDI 75 14.26 P 1 64 TE-HL
+16.95 F/L Bobbin 43 86 NQI 12.38 P 1 159 TE-HL.
+14.46-F/L Bobbin 45 40 IDI 66 4.09 P 1 19 TE-HL-
+6.49 F/L Bobbin-
.45 86 IDI 48 10.17 P 1 15 TE-HL
+12.70 F/L Bobbin-47 79 IDI 53 16.93 P.1 19 TE-HL
+14.55 F/L Total Indications Found = 72 Total Tubes Found = 56 Total Tubes in Input File = 56