lNDIANA & MICHIGAN ELECTRIC COMPANY P. O. BO X 18

)

BOWLING GREEN ST ATION N EW YORK, N. Y.10004 July 27, 1983 AEP:NRC:0837 Donald C. Cook Nuclear Plant Unit Nos. 1 and 2 Docket Nos. 50-315 and 50-316 License Nos. DPR-58 and DPR-74 IE REPORT Nos. 50-315/83-08 (DRMSP); 50-316/83-09 (DRMSP)

Mr. James G. Keppler U. S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137

Dear Mr. Keppler:

This letter is in response to Mr. C. J. Paperiello's letter dated June 28, 1983, which forwarded the subject Inspection Report of the routine safety inspection conducted by your staff at the Donald C. Cook Nuclear Plant during the periods April 27-29 and May 3-6, 1983. The Notice of Violation attached to Mr. Paperiello's letter identified one item of noncompliance with NRC requirements.

Our response to thic item is presented below.

ITEM 10 CFR 20.201(b) states that each licensee shall make or cause to be made such surveys as (1) may be necessary for the licensee to comply with the regulations in this part, and (2) are reasonable under the circumstances to evaluate the extent of radiation hazards that may be present. A " survey" is defined in 10 CFR 20.201(a) as an evaluation of the radiation hazards incident to the production, use, release, disposal, or presence of radioactive materials or other sources of radiation under a specific set of conditions.

10 CFR 20.103(b)(2) requires licensees to evaluate any intake of radioactive material which exceeds a 40-hour control measure and take actions to assure against recurrence.

Contrary to the above, in vivo count data for a terminating worker showed 95 nCi and 75 nCi of cobalt 60 on January 14 and 15, 1983, respectively. Although these data exceeded the 40-hour control measure for the long-term, insoluble cobalt 60 deposited in the lungs, no further in vivo counts or other evaluations were performed to properly evaluate the cobalt 60 deposition.

8308110284 830809

$3g N PDR ADOCK 05000 G

)

f.

Mr. James G. Keppler AEP:NRC:0837

RESPONSE

We recognize that we are not being cited for an overexposure of an individual. The cited exposure is below the limits stated in 10 CFR 20.103(a)(1). Therefore, we are addressing our actions taken to preclude recurrence of the cited incident.

(1) Corrective Action Taken and Results Achieved Based on our review, the cited incident appears to be an isolated case.

(2) Corrective Action Taken to Avoid Further Noncompliance In April, 1983, a programmatic change, reflected in procedures 12 THP 6010. RAD.447 (Whole Body Counting) revision 2 and 12 THP 6010. RAD.409 (Assessment of Whole Body Count) revision 2, was made. This change will assure that additional in vivo counts or other evaluations are performed of any indicated intake of radioactive material which exceeds a 40-hour control measure. Specifice.lly, the change requires the ir,dividual performing the whole body count to calculate the fraction of a 10 MPC-hr exposure based on'the results of the preliminary analysis of the data from the whole body count. If the results of this calculation indicate a potential exposure of greater than 10 MPC-hrs, the procedure then specifies actions to be taken including attempting personnel decontamination and/or further investigation. This change should prevent recurrence of this type of incident.

(3) Date of Full Compliance Full compliance has been achieved.

This document has been prepared following Corporate Procedures which incorporate a reasonable set of controls to insure its accuracy and completeness prior to signature by the undersigned.

Very truly yours, 1l 2

M. P. Alexich Vice President MPA:las cc: John E. Dolan R. W. Jurgensen W. G. Smith, Jr. - Bridgman R. C. Callen G. Charnoff' E. R. Swanson, NRC Resident. Inspector'- Bridgman-