h Rockwemenumwial SUPPORTING DOCUMENT Energy Syswes Group GONO.
S! A NO PAGE 1 OF TOTAL PAGES REV L R/CHG NO NUMBER 94117 4
4 33 c N001 ER000012 PROGR AM TITLE L-85 Reactor DOCUMENT TITLE L-85 Reactor - Operations Report for January 1,1982 - March 1,1983 DOCUMENT TYPE KEY NOUNS Engineering Report Reactor Operations ORIGIN AL ISSUE DATE R EL. DATE APPROVALS DATE J. P. Page 7~'O'd
-/- d '.. ", C.
M.E.Remley//h[f5,
/a%U
/
PREPARED BY/DATE DEPT Mall ADDR
.r.
.I O b t 5:w:i".; y,/ &
/
V. A. Swanson 731 T006 IR&D PROGRAM? YES O N IF YES ENTER TPA NO DISTRIBUTION ABSTRACT M A
-)(-
NAME ADDR This report presents a summary of the reactor operations and related activities conducted at the L-85 Reactor from January 1,1982 to Lucas, A.J. (25)
LA34 March 1,1983. This satisfies a reporting Maki, L.M.
NB02 requirement in the facility technical specifications.
Remley, M.E.
NB08 Schumann, G.
T034
- Tuttle, R.J.
NB13 Roberts, W.J.
LA21 Walter, J.H.
LB07 RESERVED FOR PROPRIETARY / LEGAL NOTICES 8308090730 830804 PDR ADOCK 05000375 R
-)(- COMPLETE DOCUMENT NO ASTERISK, TITLE PAGE/
SUMMARY
OF CHANGE PAGE ONLY FORM 734 C REV.12 79
~
NO N001ER000012 Rockwellintomational Enorey Systems aroup PAGE 2
TABLE OF CONTENTS SECTION PAGE~
1.
SUMMARY
OF OPERATING EXPERIENCE 3
2.
EMERGENCY SHUTDOWN AND INADVERTENT SCRAMS 3
3.
MAJOR MAINTENANCE OPERATIONS 3
4.
CHANGES TO FACILITY AND PROCEDURES 3
5.
RELEASE OF RADI0 ACTIVE EFFLUENTS 4
6.
ENVIRONMENTAL SURVEYS 4
9 i
I l
l l
l f
FORM 71SP REV. 500
..~n
) Rockwelllntemational NO N001ER000012 Energ Systems Group PAGE 3
1 1.
SUMt1ARY OF OPERATING EXPERIENCE No operations were conducted between January 1,1982 and March 1,1983.
The reactor was maintained in a standby status until July 29, 1982 at which time the fuel was drained from the core. A dismantling order, which super-sedes the Technical Specifications, was received from the NRC on March 1,1983.
2.
EMERGENCY SHUTDOWN AND INADVERTENT SCRAMS None.
3.
MAJOR MAINTENANCE OPERATIONS No major maintenance operations were performed.
Routine maintenance was performed to assure the integrity of safety circuits and monitoring instruments.
4.
CHANGES TO FACILITY AND PROCEDURES The fuel solution was drained from the reactor on July 29,1982 and was shipped to Exxon Nuclear Idaho Co., Inc., Idaho Chemical Processing Plant at INEL on September 28, 1982. The core was rinsed with distilled water. No other changes have been made to the facility.
A dismantling order was received from t'ne NRC on March 1,1983. This order replaces the Technical Specifications.
The biweekly standby procedure was reduced to the surveillance of the air monitor and the area gamma monitors only on January 1,1983. Bimonthly smear surveys continue to be made.
FORM 71&P REV. SSO
~s NO
. N001ER000012 Rockwellintomational Enwgy Systems Group PAGE 4
5.
RELEASE OF RADI0 ACTIVE EFFLUENTS No uncontrolled radioactive effluents were released or discharged to the environs.
A minor spill of a few milliliters of rinse water occurred following the fuel drain. A majority of the contamination was cleaned up and the remainder was fixed with paint pending the complete decontamination and dismantling of the facility. The spill occurred within a radiologically controlled area.
6.
ENVIRONMENTAL SURVEYS Environmental surveys are performed by the Radiation and Nuclear Safety Unit by sampling for radioactive analysis the soil, vegetation, water and air up to a distance of 10 miles from Energy Systems Group, California sites. A report by J. D. Moore
- describing the monitoring procedures and results for 1982 summarizes these surveys. This report concludes that environmental radioactivity observed by the monitoring is attributable to natural sources and to fallout of radioactive material from foreign atmospheric testing of nuclear devices rather than to Energy Systems Group operations at California sites.
- J. D. Moore, " Energy Systems Group Environmental Monitoring and Facility Effluent Annual Report - 1982.", ESG-83-17.
PORM 71SP REV. SW3
.