ML20077F260

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Unverified Computer Code for Main Feedwater Pipe Supports.Ae Indicated That New Computer Input Data Required in Order to Complete Analysis of Subj. Final Rept Will Be Submitted by 840203
ML20077F260
Person / Time
Site: Vogtle  
Issue date: 07/14/1983
From: Foster D
GEORGIA POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, GN-242, NUDOCS 8308010311
Download: ML20077F260 (1)


Text

< ~

'Sectoo Tower Cornpany (j,,

Post GW2 Box 4545 f '~

' AtlantTGeorgia 3030E 4 y. 'f V.3{I p,.

^

,' 4, o "_*D'd'Y Teiephone 404 526-6526 q.,,

e 7

f c,9 Southirn Company Seroces. 8nc.

GCMi2 Power Post Ghce Box Iu25

[/M.f2 Soutber:1[dn)y yScryices 8

/-

03 D. O. Foster Vica Prt Ment aIU General Manager Vogtie Preic:

July 14, 1933 United States Nuclear Regulatory Commission File:

X7BCJ3-M34 Office of Inspection and Enforcement Log:

GN-242 Region II-Suite 3100' 101 Marietta Street Atlanta, Georgia 30303

Reference:

Vogtle Electric Generating Plant - Units 1 & 2 50-424, 50-425; foain Feedwater Pipe Supports - Unverified Computer Code, GN-224 Dated April 28, 1983'

/

Att'ention: Mr. James P. O'Reilly

' Gentlemen:

In our previous corres pndence~on this issue, Georgia Poker Company stated that we expected to file a final ' report to the NRC by August 5,1933.

A recent letter from our architect / engineer ha: indicated that new computer input d6ta is required in order to complete the analysis of tnis issue.'

Georgia Power Company has been advised it will take the A/E approximately 12 to 16 weeks to' obtain this data. Based on this information, Georgia Power' Company now expects to submit a final report to the NRC by February 3, 1984.

This response contains no proprietary information and may be piaced in the NRC Public Document upon receipt.

~\\'

Yours truly,

/

N D. O. Foster j

_ DOF/CMH/lcb;, -

~

/

U. S. Nuclear Regulatory Commission

'w r-xc:

Document Control Desk 4

Washington, D. C. 20555 a..

R. J. Kelly

.R. H. Pinson lE. D. Groover R. E. Conway

- B. M. Guthrie - '<

L. T. Gucwa l

G.-F. Head R. A. Thomas M. Malcom

.x.

l J'. *

. J. T. Beckham Jr.

J. A. ' Bailey G. Bockhold c.

f,"

4' D. N. MacLemora. e

0. Batum P. D. Rice.

E D. E. Dutton-

+

H. H. Gregory.III

?J. L. Vota w

' R. E. Folker W. F. Sanders.

8308010311 830714 oFFICIALCOPY fm gA M

~^

PDR ADDCK 05000424 l;

S_

j w

PDR

_