ML20076M144

From kanterella
Jump to navigation Jump to search
Monthly Operating Repts for June 1983
ML20076M144
Person / Time
Site: Calvert Cliffs  
Issue date: 07/14/1983
From: Lotito E
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
NUDOCS 8307200169
Download: ML20076M144 (11)


Text

.

.g i

OPERATING DAT A REPORT 50_317 DOJET NO.

D Al E,_..._7114 /81 _

LOMPl. Ell D 11YE l a i ne Lotito TiLEMl0NE(301)787 5363 iT) R ATING STATUS i

l bdI#2

1. U.i: N,ime:

Calvert Cliffs No. 1 2 Rei ortu.g PerioJ.

. lune 1983

_ i t

J. L;:tnad lhemull'u%r iMWil.

2,700

4. N..tiep!ste Rating (Gr.o Sibe 9I8 l

S. Deup Elc.srica! Racoe ' Net \\lbcp 845 Mnimum f.epen taa:e Capacity iGrins $1Wes:

860 o

\\tnamem 1,peadJ'!c Opac.:y l Net Albe).

825 s

S. It Caarges Occt.r it ( ap..it) R tmp.ite.m Nunter 3 i breyb in he i.:.s: Re;.. :. Gi.c Renom.

', Po ci i es el l o bi ;.!. la f.i... t.d. If An:. (*=et Mh s t.

10

.!ea.m.s !

L,tr:. *... It. n -

I h i, '.hnith Y< to D, -

G:r.uh.im

11. itctn in ilm.enn; Peno.t 720. _

4,343.

71,412 12 Niard er a: lime, Reutor 4.n Critis:1 697.2 4,127.7 57,223.6 la React.r f:u.ne SurJan a Ita::rs 0. 0_ _

11.8 1,820.3 14 licur. Generatar On I u.e 692.4 4,106.4 56,130.3

15. Uit Iteser e Sfmtdown llouri 0.0 0.0 0.0
15. Grves Thermet E n-in Gererated i5thit

__ _1.769,837 10,805,981 137,476,027 17 ' tuo El-cirkali.nerp Grnerserd lMWil) 577,873 3,639,689 45,240,632 l'. Net Eh tne.:1 E.iriq) (.coerated IMWIII 552,533 3,486,192 43,150,400 d

19. lmt Smi e f ator

_ __.__.96.2 94.6 78.6

.0 Un.i.u: stabile. I.:cier 96.2 94.6 78.6

21. 3 *ni: sp;.eity ISe:.r (U.ang UDC Ner e

_ 31,0_.

97.3 74.4 0

d L'mt C:;nity f u:c.r (Us.y IWR *,'er

__9Q 8 95.0 71.5

23. th i; }. reed uutn.e H.ne 3.8_

2._7.

7.7

.4. Sh iJmis Scheddei! U.a Ne st 6 Montin ( f.s pe Inte. sed D. c.sg.n c; f.a. hl

_..y.-

~~

_. - ~

25. If St.ut O..wu A' Er.J of l'.ep..rt l'essol,I stimated Date of Stataup.

5

26. Unib la Test Status it'ri.t la Commercial Oper sion1 brrecast Ach.eesed thlTIAt rulTICal.ity 1

i I.*.'lil 4 L Et i C IR; CITY

~ ~ ~ ~ ~ ~ "

COMMERCI\\L OPLR t floN

~ ~ ' '

~ ~ ~ ~ ~

8307200169 830714 PDR ADOCK 05000317 R

PDR _

g ',- ' #.

i i

,a OPERATING DATA REPORT DOCKET NO.

50-318_

DATE 7/.14/83 COMPl.ETED fiY Elaine Loti to

~

Tl LEFil0NE( iliii 787 5363 OPl itAllNG STAIUS

1. tl:..: Lme:

CaIvert Cliifs No. 2 Nd8')

2. Iterotting Penaj.

June 1983

3. Li:enwd Thernul Puwcr :MWt h

700

')

911

4. Na:epts:e Rating (Gro>. \\lhe r i
5. Dew,;a E!uaica! Kaim,:'* en MheU 845 i

3 6 Mnient.m Dependaa.e Gpacity (Grow Mbel.

860 s

7. %Issimern bependabic Capacery (Nei MWen 825 l

J

5. If C.ur;,,ci Oca.: m br ii) Hari,p site.m Nunter 3 Thro /h 7) Siace Lat Repur:. Gise Rcasons 9

P.).a is L a el lo hM !. R e.tr.itol. If A ny 1. Net Mh A

10. E r J W.h F er Re.f rt. re.-. !! *.1).

~_

lhis Man:h y,.,3. Dr.:

Cuaut.i.ve

!!. Jan in R.porti:y e.ioa 720 4,343 54,767 a

12. !G.nt er 01 f fmirs Reactor % Critiel 720.0_,

3,939.2 46,040.I

13. React tr Rchne 55urdaw a li s.:r>

0.0 95.6

.890.8 14 Ifoters Gen.::. tar On L me 720.0 '

-3,781.4 45,324.3

'l$ UrJt Rewr e Sh.tidown !! nun 0. 0_ _

_ 0.0 O_. 0 l's. Gran Therms: En..rp Ge erated tMhill 1.931,405 9,875,552 112,096,309 I? r.,ron Etrcinical E ner,v G.nt n <d :Mhlti 624,826

-3,254,952 36,911,156

18. Net Elu : cal Energy ( cres.:ted IMWi1, 598.408 3,107.117

_ 35,197,899

19. Lnit Senite hu n 100.0_

87.1 82.8

0 'ir.;t A.
:tabilis. F acter 100.0 87.1 82.8 21 Uni: C2,ue:n rae:or iU,mg \\sDC Neo 100.7 86.7 78.5
22. Un's C:prity f.: cur tting DI.R *ical 98_.4 84.7 76.1
23. Us i! 1orced Ourage H ie 0.0 3.3 5'T
24. Shurda...o %heticle ! t:.er Nns 6.'. onttts t > re Dste, and Duratir.n of Ea;hl
25. If 5hur D.v,.n &* End f>f Rep..it Permi. I sti:ns:cd Dele of Startap.
16. Units in t est Status (l'ri.it to C.mmercial Oper*t:oni forecast

. Achiesed I.NITI A L CRI TIC.\\ LITY t

INilliL El LC IP.1Cl1Y COMMERCI AL OPER GloN p
  • l

. AVE R AGE D \\lLY UNIT POWER LEVEL 1

50-317

- DOCKET NO. _

UNIT _Calvert Cliffs #1 j.

DALE -

7/14/83 COVfLETED BY Elaine totito 1ELEff!ONE 1301) 787-5363 June 1983 MONTil i

DAY AVER AGE DAll Y POWER LEVEL DAY AVER AGE 1)AILY P0hER LEVEL (Mhr Net)

IMwe Net i 3

858 662

'g 2

861 33 652 3

_ 868 in 684 868 862 4

30

-5 869 33 849 6 -

710 849 33 833 7

73 4

549 74 858 9

__853 857 S

8M 857-10 26 -

l 857 854 27 361-855 g;

3 4

13 673

.854 39 la -

662 853 30 15 661 3-16 662 4

INSTRUCTIONS On this fortnat,lat the nerage daily unit power levelin MWe Net for each day in the reporting month. Coinpute to the ricatest whole nwpawatt.

(ol??)

_. - ~ _ _

~

l

,l AVE!! AGE D \\lLY UNIT POWER LEVEL IX)CKE F NO.

50-318 Calvert Cliffs #2 E'IT DATE 7/14/83 COMPLETED BY Elaine Lotito TEl.Erfl0NE Q01) 787-5363 une 1983 MONTil DAY AVER AGE DAll Y POWER LEVf t.

DAY AVER AGE 1)AILY P0hER LEVEL (Mbe Nett (Mwe Nc 1

837 17 838 2-836 839 gg 3

840 824 gg 4-841 20 836 5

843_

834

.g 6

840 828 33 7

_ Bal 23 825 g

837 24 828 9

_834 826 10 832 26 807 Ii 834 27

_827 12 788 831 2g 13 836 830 39 14 835 30 827 15 835 3g 16 836 INS 111UCll0NS On this format.In: the aserage da !y unit power levelin MWe Net for each day in the reporting anonth. Com;:ste Io the nearest whole nwpwait, 19177:

l 50-317 DOCKET NO.

uni T SliU100WNS AND POWER REDUCTIONS Calvert Clitts #1 L* NIT N AME DATE 7/14/83 COMPLET ED BY Elaine Lotito June 1983 RFPORT MONIll TELEI*If0NE (30I) 787 5363 i

1 e

L hensee

[-(

ft Cau.c & Corse 6tave l

j[

!g

&T Attson to N.

Dare g

3=

{

25d thent

&g *g

~}'

Paesent Recurrence O

35 5

j5g Repust c 5

83-06 830606

.F 27.6~

A 1

XX ZZZZZZ Failure of No. 11A Reactor Coolant Purnp Motor Surge Suppressor.

i 83-07 830613 S

163.0 B

5 XX ZZZZZZ Repair Leaks in No. 15B Feedwater lleater.

(Reduced to Various Loads) l p

3 l

F Forced Rea son.

' Mettos!:

E Jut it G -instructions

(

S. Scheduled A rquipment Fa:! ore (Esplun)

1. Manual for Prepar.ition of Data

(

0. Maintenance of Te::

2-Menual Scrs:n.

f.ntrv Sheets l'er Licensee F.Re t nel.r g 3-Autonat.e scram.

Ewn Report (LER) File (NUREG-l D. Regt: tat..r> R eti t i.t eun 4 Zontinu;ttton I'I t'

)

(

! (1per.a.as T..uning & Licens: Ilt.st'unat son r,_..M F. dia t i m.

(

F Adirinists.str.e 3~

G.0;,er.stion.! E.sor ( E spl.in s..

Editut i Sanie Sourse l'

7

"(9/77)

If 4'ther 4 F setsin) h l

I

t UNIT SPIUlDOWNS AND POWER REDUCTIONS DOCKET NO; Caivert Clitts #2 3

UNIT N AME

  1. /10/83 DATE-Elaine Lotito COMPLETED EY REPORT MONT11 June 1983 IILEPif0NE (30t) 787-5163 i

5 F.

$p

'h j Ei Licensee h

K Cause & Currective

-E-3i R

25E Esent g

E.T Action to No.

Da te

}'

Paesent Recurrence jE y

t ;f, Reporie mO r

6 No Outages or Reductions t

l 1

4 I

F: Forced Rea son.

Method:

E Jiitsit G - Instructions S: Scheduled A Equipment Failure (Esplain)

. I Manual for Prepar.ition of Data B. Maintenance of Test -

2-Manual Seram.

Entrv Sheers for Lcensee C-Refuelin;;

1 Autonat.e Scram.

Esent Repor (LER) File (NUREG-l D Regul.itory Restriction Ju0ontinuation D1bll 1.-Oper.itor Trammg A Ucens: Eumination

's-Load Reductfor.

i 5

F Administuine 9-O t ha G4)peution.! Es tor ( E splam)

Eshibu ! Same Source

(*1/77)

Il4'iher ( E spLm) i

  • e e

G A-

-~

July 13,1983' REFUELING INFORMATION REQUEST 1.

Name of Facility: Calvert Cliffs Nuclear Power Plant, Unit No.1 2.

Scheduled date for next Refueling Shutdown: September 30.1983 3.

Scheduled date for restart following refueling: December 1,1983 4.-

Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?

Resumption of operation after refueling will require changes to Technical Specifications. The changes will be such as to allow operation of the plant with a fresh reload batch and reshuffled core.

5.

Scheduled date(s) for submitting proposed licensing action and supporting information.

September 1,1983 6.

Important licensing considerations associated with the refueling.

Reload fuel will be similar to that reload fuel inserted into the previous cycle.

7.

The number of fuel assemblies (a) in the core and (b) in the spent fuel storage pool.

(a) 217 (b) 732 Spent Fuel Pools are common to Units 1 and 2 8.

The present licensed spent fuel pool storage capacity and the size of any increase in licensed storage capacity that has been requested or is planned, in number of fuel assemblies.

3 1830 Licensed 830 Currently Installed 9.

The projected date of the last refueling that can be discharged to the Spent Fuel Pool assuming the present licensed capacity and maintaining space for one full core off load.

April,1991

+

,-t-g-e---

T

F July 13,1983 REFUELING INFORMATION REQUEST 1.

Name of Facility: Calvert Cliffs Nuclear Power Plant, Unit No. 2.

2.

Scheduled date for next refueling shutdown: April 20,1984.

J 3.

Scheduled date for restart following refueling: June 10,1984.

4.

Will refueling or resumption of operation thereafter require a technical specification change or other licensed amendment?

Resumption of operation after refueling will require changes to Technical Specifications. The changes will be such as to allow operation of the plant with a fresh relod batch and reshuffled core.

5.

Scheduled date(s) for submitting proposed licensing action and supporting information.

March 3,1984 6.

Important licensing considerations associated with refueling.

Reload fuel will be similar to that reload fuel inserted in the previous cycle.

7.

The number of fuel assemblies (a) in the core and (b) in the Spent Fuel Storage Pool.

(a) 217 (b) 732 Spent Fuel Poolis common to Units 1 and 2.

8.

The present licensed spent fuel pool storage capacity and the size of any increase in licensed storage capacity that has been required or is planned, in number of fuel assemblies.

1830 Licensed 830 Currently Installed 9.

The projected date of the last refueling that can be discharged to the Spent Fuel Pool assuming the present licensed capacity and maintaining space for one full core off load.

April,1991

t

SUMMARY

OF UNIT I OPERATING EXPERIENCE JUNE 1983 6/1 At the beginning of this reporting period, Unit I was operating at 857 MWe with the reactor at 100% power.

6/6 The reactor was tripped at 1945 due to the f ailure of II A Reactor Coolant Pump Motor Surge Suppressor.

6/9 Resumed full load operation (852 MWe) at 0200.

6/13 At 0002 load was decreased to 654 MWe to locate and repair leaks in ISB Feedwater Heater.

6/18 At 1755 reduced reactor power due to loss of secondary Control Element Assembly (CEA) position indication. At 1955 CEA position indication was returned to servics.. Load was increased to 646 MWe at 2020.

6/19 At 2015 ISB Feedwater Heater was placed in service. Resumed full load operation (862 MWei at 2300.

6/21 At 0120 load was decreased to 758 MWe to clean condenser water boxes. Load was increased to capacity (862 MWe) at 0540.

6/22 At 2200 load was decreased to 764 MWe to clean condenser water boxes.

6/23 Load was increased to capacity (860 MWe) at 0700.

6/30 At the end of this reporting period, Unit I was operating at 858 MWe with the reactor at 100% power.

SUMMARY

OF UNIT 2 OPERATING EXPERIENCE JUNE 1983 6/1 At the beginning of this reporting period, Unit 2 was operating at 835 MWe with the reactor at 100% power.

6/12 Decreased load to 730 MWe at 0500 to inspect Amertap Screens. Load was increased to capacity (835 MWe) at 1800.

6/19 Decreased load to 743 MWe at 0017 following the trip of 26 Circulating Water Pump. Atter returning 26 Circulating Water Pump to service, load was increased to capacity (841 MWe) at 0645.

6/25 At 2330 load was decreased to 730 MWe to clean condenser water boxes.

6/26 Load was increased to capacity (860 MWe) at 0815.

6/30 At the end of this reporting period, Unit 2 was operating at 830 MWe with the reactor at 100% power.

e

. ~ -

g

.t BALTIMORE GAS AND ELECTRIC CHARLES CENTER. P.O. BOX 1475 BALTIMORE, MARYLAND 21203 FOS $1L POWER DEPARTMENT July 15, 1983 Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D.C.

20055 ATTENTION: Document Control Desk Gentlemen:

Enclosed herewith is the June 1983 - Operatico Status Report for Calvert Cliffs No. 1 Unit, (Docket. 50-317) and Calvert Cliffs No. 2 Unit, (Docket 50-318).

Sincerely, N.

Elaine M.

Lotito Performance Data Analyser Production Economy and Results Unit Fossil Power Depa rtment Enclosure cc: - Messrs. W. Lavalle~

J. Tiernan C. McCabe, Jr.

R. Architzel P. Krause L. Russel P. Ross P. Sierer,.Jr.

M. Beebe C. Schoemaker D. Reilly R. Ash Dr. S. Long V. Stricklin A. Lundvall

'EML/dch rfTV i i

,