S

-[,

e Georgia Power Company

,e-Post Office Box 439

~~'

9 M' O N * *N' Bexley, Georgia 31513

^ + 0T'4 Telephone 912 367 1RO f,y(I I' 912 537

?. _ d

  • GeorgiaFbwer Edwin I. Hatch Nuchb August 31, 1983 GM-83-842 PLANT E.

I.

HATCH Licensee Event Report Docket No. 50-366 United States Nuclear Regulatory commission Office of Inspection and Enforcement Region II Suite 3100 101 Marietta Street Atlanta, Georgia 30303 ATTENT ION :

Mr. James P. O'Reilly Reportable Occurrence number 50-366/1983-061 was reported to you on August 8,1983, via an RO telegram; however, further investigation has shown that the occurrence should not have been considered a reportable occurrence (refer to attached narrative).

Thus, we are withdrawing that report.

Also, please note that this report number will be used for a subsequent reportable occurence.

i H.

C.

Nix General Manager N

HCN/SBT/djs xc.

R.

J.

Kelly G.

F.

Head J.

T.

Beckham, Jr.

P.

D.

Rice K. M. Gillespie S.

B. Tipps R.

D.

Baker Control Room opHCIAI. COPY Document Control b

3 iWmwaan t/t

}

PM

J.

-Item 2-of. Tech.

Specs.

table 3.3.5-1 requires the following to be operable in order for the Rod Block Monitors (RBM) to be operable:

upscale, inoperative, and downscale.

The RBM's have the following functions: downscale, inoperative, low trip, intermediate trip, and high trip.

The intermediate trip acts Las the. upscale trip below 100 % of rated recirculation flow, and then the high trip acts as the upscale trip.

The RO telegram reported that the intermediate trip was set in a non-conservative direction.

Further investigation has shown that.the intermediate trip was set correctly; the low trip was the only trip setpoint which was; outside of the procedural requirements.

There is no Tech. Specs. requirement for.the low trip.

This event was determined to be non-repcrtable on August 15, 1983, in

)

Plant Review Board meeting number 83-159.

-