- GeorgiaFbwer Edwin I. Hatch Nuchb August 31, 1983 GM-83-842 PLANT E.
I.
HATCH Licensee Event Report Docket No. 50-366 United States Nuclear Regulatory commission Office of Inspection and Enforcement Region II Suite 3100 101 Marietta Street Atlanta, Georgia 30303 ATTENT ION :
Mr. James P. O'Reilly Reportable Occurrence number 50-366/1983-061 was reported to you on August 8,1983, via an RO telegram; however, further investigation has shown that the occurrence should not have been considered a reportable occurrence (refer to attached narrative).
Thus, we are withdrawing that report.
Also, please note that this report number will be used for a subsequent reportable occurence.
i H.
C.
Nix General Manager N
HCN/SBT/djs xc.
R.
J.
Kelly G.
F.
Head J.
T.
Beckham, Jr.
P.
D.
Rice K. M. Gillespie S.
B. Tipps R.
D.
Baker Control Room opHCIAI. COPY Document Control b
3 iWmwaan t/t
}
J.
-Item 2-of. Tech.
Specs.
table 3.3.5-1 requires the following to be operable in order for the Rod Block Monitors (RBM) to be operable:
upscale, inoperative, and downscale.
The RBM's have the following functions: downscale, inoperative, low trip, intermediate trip, and high trip.
The intermediate trip acts Las the. upscale trip below 100 % of rated recirculation flow, and then the high trip acts as the upscale trip.
The RO telegram reported that the intermediate trip was set in a non-conservative direction.
Further investigation has shown that.the intermediate trip was set correctly; the low trip was the only trip setpoint which was; outside of the procedural requirements.
There is no Tech. Specs. requirement for.the low trip.
This event was determined to be non-repcrtable on August 15, 1983, in
)