ML20076F910

From kanterella
Jump to navigation Jump to search
Forwards Revised Schedule for post-accident Instrumentation Transmitted by Re Environ Qualification of Electrical Equipment (10CFR50.49).Date of Referenced Ltr Corrected.Original Encl Should Be Replaced
ML20076F910
Person / Time
Site: Crane 
Issue date: 06/08/1983
From: Hukill H
GENERAL PUBLIC UTILITIES CORP.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.D.3, TASK-2.E.1.2, TASK-2.F.1, TASK-2.F.2, TASK-TM 5211-83-173, NUDOCS 8306140480
Download: ML20076F910 (2)


Text

-

GPU Nuclear Corporation

3 Nuclear
r1e9;Ss48o 8

fAiddletown Pennsylvania 17057 717 944-7621 TELEX 84-2386 Writer"s Direct Dial Number:

June 8, 1983 5211-83-173 h

Of fice of Nuclear Reactor Regulation Attn:

!!. A. Denton, Director U. S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Sir:

Three Mile Island Nuclear Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Environmental Qualification of Electrical Equipment (10 CFR 50.49)

In the attachment to our letter of May 20, 1983 (5211-83-157), we inadvertently l

referenced an incorrect letter.

Enclosed is a revised attachment.

Please destroy the original attachment and replace it with the enclosed.

Sincerely, 1.

ukill Director, TMI-l llDil:vj f Enclosure cc:

J. Allen l

J. Stolz j

J. Van Vliet

/

8306140480 830609 DR ADOCK 0300C287 PDR gO GPU Nuclear Corporation is a subsidiary of the General Public Utilit es Corporation l

l

c IMI-l Post Accident Instrumentation (Environmentally Qualified)

~

Regulatory Guide 1.97, Rev. 2 ITEli CAT.

TYPE EllVIRONMENTAL QUALIf_ICATION RCS Ilot Leg 11 0 Temp i

B NUREG 0737 Item II.F.1 2

RCS Cold Leg il 0 Temp,

1 B

NUREG 0737.Iten II.F.1 j

RCS Pressure 1

C NUREG 0737 Itein II.F.2 sheets 12 and 13*

Core. Exit Temp (Incore 1/C) i B

NUREG 0737 II.F.2 sheet 1 thru 11*

Saturation Monitor i

B NUREG 0737 II.F.2 sheets 12 and 13*

R.ll. Sym13 evel 2

11 NUREG 0737 Item II.F. sheets 15 thru 18*

L R.it. Pressure 1

B NUREG 0737 II.F.1 RB 11 Concentration

  • 1 C

NUREG 0737 Item II.F.1 sheets 1 thru 12*

2 Ull Exchanger Outlet Temp 2

D NUREG 0737 Item II.F.2 Dil Removal flow /LPI flow 2

0 NUREG 0737 Item II.F.2 PORV/ Safety Valve Posi tion 2

D NUREG 0737 Item II.D.3 sheets 1 thru 9*

Pressurizer Level 1

D NUREG 0737 Item II.D.3 S/G Level 1

D NUREG 0737 Item II.F.2 S/G Pressure 2

D NUREG 0737 Item II.F.1 EfW flow 1

D NUREG 0737 Item II.E.1.2 sheets 1 thur 6*

Mut Level 2

D NUREG 0737 Item II.F.1 R.ll liigh Range Radiation i

E NUREG 0737 Item II.F.1 sheets 13 and 14*

aSee GPUH Letter dated May 16, 1933, (83-o76 )

~

h 4