Ibl' ECTR,IC' July 24, 1991 U.S. Nuclear Regulatory Commission ATTN Document Control Desk Mail Station Pl-137 Washington, D.C.
20555 ULNRC-24 4 7 Gentlement DOCKET NUMBER 50-403 CALLAWAY PLANT FAILURE OF WESTINGilOUSE STEAM GENERATOR TUBE MECHANICAL PLUGS Referenco: HRC Bulletin No. 89-01, Supplomont 2, dated June 28, 1991 HRC Bulletin No. 89-01, Supplomont 2, Action Item 1 requested Licensons to verify that information contained in Tablo 2 of Reference 4 for plugs fabricated from group 2 heats is correct.
The information contained in Tablo 2 of Referenco 4 is correct for Callaway Plant regarding the number of plugs installed in the hot-log and cold-leg side of each steam generator, their heat numbers, and datos of installation.
The plug operating temperaturo, however, should be revis9d to 618.4 degrees F for the HL and 588.4 degroos F for the CL plugs.
Action item 2a through 2f will be addressed as follows:
Union Electric will remove all of the subject hot-leg plugs at the next refueling outage in the Spring, 1992.
The cold-log plugs will not be removed, as their romaining predicted lifetimes are sufficient for them to remain installed for the life of the plant.
Plugs fabri-cated from Inconel 600 will not be installed in the future.
Maintaining personnel exposure ALARA will be a high priority for the tubo plug removal work to be performed.
If there are any questions concerning this matter, pleano contact me.
Very truly yours,
/a
-(A Donald F. Schnell JMC/ dis 7
9107300032 910724
[
l suco gun n=cu **gp i
p
o STATE OF MISSOURI )
)
Donald F.
Schnell, of lawful ago, being firnt duly sworn upon oath says that he in Senior Vice President-tuclear and an officer of Union Electric Company; that he has road the forogoing document and Itnown the content thoroof; that he has executed the same for and on oehalf of said company with full power and authority to do no; and that the facto theroin ntated aro true and correct to tho bent of his Itnowledge, information and belief.
n.
By
)
_{t, t Donald F.
Schnell Senior Vice President 14ucionr c/ M SUBSCRI ED and sworn to before me this day i
l of Jm 1991.
$lk/ t h..
h_
D#Rf1 ARA "1 Pf Aff i
NOTARY PUBLIC, STAf[ Ci MISSOURt t
MY C0YMISSION DPIR(5 A!' Ell 22,1993 l_
ST. LOUIS COUNTY l
cc:
T.
A.
13n x t e r, Esq.
Shaw, Pittman, Pottn & Ti owbri< lyn 2300 14. Street, 14. W.
Washington, D.C.
20037 Dr.
J.
O.
Ce rmalt CFA, Inc.
18225-A Flowet 11111 Way Gnithersburg, MD 20079-5334 11.
C.
Knop Chief, Ronctor Pioject I? ranch 1 U.S.
Nuclear Degulatory Comminnion Region 111 799 Roonevelt Road Ginn Ellyn, Illinois 60137 Bruce Bartlett Cr i 1nwny llonident of fico U. fi. 11ucionr Regulator y Commi nnion RRtt i Stoodman, Minnouri 65077 D.
Lynch (2)
Jf fice of thiclent Reactor Regulation U.S.
flucient Regulatory Comminnion 1 White Flint, llo r th, Mail Stop 13E21 11555 Rocl<ville Pike Rockville, MD 20052 Manager, Electric Department Minnour.i Public Snrvice Comminnion P.O.
Dox 360 Jeffernon City, MO 65102
I bec:
D. Shafer/A160.761
/QA Record (CA-758) 11uclear Date E210.01 DFS/ Chrono F. Schnell E.
Birk s.
J. V.
Laux M.
A.
Stiller G.
L. Randolph R.
J.
Irwin P. Barrott C. D. 11a nlund A.
C. Passwater D.
E.
Shafer W.
E.
liahl 11. Chernoff (WCl40C)
R. C. Slovic (Bechtel)
T.
P.
Sharkey 148RB- ( Sandra Auston)
.. _