ML20076D473

From kanterella
Jump to navigation Jump to search
Responds to NRC Re Violations Noted in IE Insp Rept 50-366/83-16.Corrective Actions:Surface Grinding Performed to Eliminate Causes of Indications on Welds.Weld Surveillance Procedures Will Be Revised
ML20076D473
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 07/27/1983
From: Beckham J
GEORGIA POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20076D471 List:
References
NED-83-401, NUDOCS 8308230414
Download: ML20076D473 (2)


Text

F

}

George Power Company 333 Pedmont Avenue At:anta. Georg a 30308 e

Telephone 404 526-7020 pp

,e

{,,

MaAng Address-O L /dC A. ' O Post offee Box 4545 Atlanta. Georgia 30302 n9: 59 Georgia Power B3 MG 3 J. T. Beckham, Jr.

the southem electnc system Vice President and Generaf Manager Nuclear Generat on D-83-401 July 27, 1983 U. S. Nuclear Regulatory Commission

REFERENCE:

Office of Inspection and Enforcement RII: JPO Region II - Suite 2900 50-366 101 Marietta Street, NW I&E Report Atlanta, Georgia 30303 83-16 ATTENTION:

Mr. James P. O'Reilly GENTLEMEN:

Georgia Power Company submits the following in response to the violation cited by the inspection conducted by Mr. B. R. Crowley of your office on June 6-8, 1983. The subject violation was applicable to Hatch Unit 2 only.

VIOLATION Technical Specification 6.8.1.c requires that procedures be implemented for surveillance of safety-related equipment.

Paragraph G of the applicable procedure for Technical Specification Requirements 4.4.8, requires in part that, for flaw indications found during inservice inspection and reported on an indication notification form, sufficient nondestructive test expertise adequately resolve necessary report work to eliminate the flaw indication or prove insignificant the source of the indication.

Contrary to the above, on April 28, 1982, procedure HNP-904 was not properly implemented (sic) in that the liquid - penetrant inspection for weld 2 Ell-lRHR-20-RS-1BC/2G21-lRWCU-60-1 (sic) was accepted without necessary repair work to eliminate or prove insignificant rough conditions in the weld edges which hela excess penetrant possibly masking significant indications.

This is a Severity Level V Violation (Supplement I).

8308230414 830815 PDR ADOCK 05000366 G

PDR

i Georgia Power A U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement July 27, 1983 Page Two

RESPONSE

Admission or denial of alleged violation:

The violation occurred.

It should be noted that the qualified inspector felt the weld was adequately prepared prior to his April 28, 1982 inspection.

In addition, the weld was subsequently found acceptable during the 1983 maintenance / refueling outage after surface grinding and reexamination by a qualified inspector.

Reason for violation:

The violation occurred as a result of a decision to not perform grinding on piping for the resolution of indications which did not appear to be service induced.

It was decided that if an indication appeared to be non-service (process). induced, and visual examination could determine the cause of the indications, it was to be disposed as process induced and left as found.

Such was the case with weld 2 Ell-lRm-20-RS-LBC/2G31-1RWCU-6D-1.

Corrective steps which have been taken and the results achieved:

As a result of the concern raised by the NRC inspector, surface grinding was performed to eliminate the causes of the indications.

The area was reexamined by a qualified inspector and found acceptable.

Corrective steps that will be taken to avoid further violations:

Although this case appears to be an isolated event, it is apparent that a revision to the HtF-904 procedure is necessary.

The procedural change will give specific guidance regarding how indications are to be resolved.

The revision to HNP-904 will be submitted to the Plant Review Board by September 1, 1983.

Date when full compliance will be achieved:

Full compliance was achieved on June 4,1983, when the weld in question was reexamined by a qualified inspector and found acceptable.

Should you have any questio:s in this regard, please contact this office.

Sincerely yours, h,

f

. T. Beckham, Jr.

JAE/mb xc:

L. T. Gucwa H. C. Nix, Jr.

Senior Resident Inspector

'00775

-