ML20076D365

From kanterella
Jump to navigation Jump to search

Provides Justification for Exemption from GDC 57 Re Containment Isolation Valves,Per
ML20076D365
Person / Time
Site: Beaver Valley
Issue date: 07/19/1991
From: Sieber J
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
TAC-75772, NUDOCS 9107290082
Download: ML20076D365 (2)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _.

o,

f vg, n,e neu,

s+.w,cn n wuva July 19, 1991 u.u om,,

n. n.-- w, c.m.,

v.

~

U.

S.

11uclear Regulatory Commis31on Attn Document Control Desh Washington, DC 20555

Subject:

lleaver Valley Power Station, Unit No. 1 Docket No. 50-334, Licenne No. DPH-66 Exemption From General Des?qn Criterion 57 Ref:

Letter irom A.W.

DeAgazio (Nuclear Regulatory Commission) to J.D.

Sieber (Duquesne Light Company),

Regarding:

Exemption from GDC-57, TAC 75772 (June 26, 1991).

The referenced letter forwarded an exemption from the requirements of General Design Criterion (GDC) 57, and requested an implementation schedule for related action items.

Each action item is described below with a scheduled or actual completion date.

Item 6 i nc11.J e valvec RW-615, -621, ~627, and -633 in the Technical Specifications as containment isolation valves.

Presently we are considering removal of Table 3.6-1,

" Containment Penetrations,"

from Technical Specifications in accordance with Generic Letter 91-08, " Removal of Component Lists from Technical Specifications."

Therefore, a

Technical Specification change will be submitted by February 28, 1992 to either 1.

Include the valves referenced above in Technical Specification Table 3.6-1, or 2.

Include the valves referenced above in Technical Specification Table 3.6-1, and move the Table from Technical Specifications to plant procedures in accordance with Generic Letter 91-08.

ItemJ}

Test valves RW-615, -621, -627, and -633 in accordance with the requirements of ASME Section XI.

The valves referenced above have been included in Revision 7 of the Inservice Testing Program (effective June 7, 1991) and will be tested in accordance with ASME Section XI.

'9id)heOOO2 910719

. [,

pon noock omov m p

PDR

,g

Exemption l' rom General Denign Criterion 57 Page 2 l

lirIn_C Revine the radiation monitor alarm response procedure.

The affected radiation monitor alarm renponse procedures were revined by an operating manual change notice which was offective July 13, 1990.

Should you have any questions regarding thin schedule, pleaec contact Ken McMullen at (412) 393-5214.

Sincerely, D.

Sieber Vice Prenident 11uclear Group cc: