Malling Address M
, ' Alabama Power Company 9
- +
600 North 18th Street Post Offics Box 2641 Birmingham. Alabama 35291 ATLtJ.h,py;y3M'.~i 0$NR
. 0it'31 A 1elephone 205 783-6081 F. L Clayton, Jr.
Senior Vice President AlabamaPbwer Flintridge Building
}
Docket No. 50-348 Docket No. 50-364 Mr. R. C. Lewis, Director U. S. NUCLEAR REGULATORY COMMISSION Region II l
101 Marietta Street, N.W.
Suite 3100 Atlanta, Georgia 30303
SUBJECT:
J. M. Farley Nuclear Plant NRC Inspection of May 16 - 20 and June 6-7, 1983 RE: Report Numbers 50-348/83-16 and 50-364/83-14
Dear Mr. Lewis:
This letter refers to the violation cited in the subject inspection reports which states:
l "As a result of the inspection conducted on May 16-20 and June 6-7, 1983, and in accordance with the NRC Enforcement Policy, 47 FR 9987 (March 9,1982), the following violation was identified.
10 CFR 20.203(e) and (f) states in part that each area or room in which licensed material is used or stored and which contains any radioactive material (other than natural uranium or thorium) in an amount exceeding 10 times the quantity of such material specified in Appendix C of Part 20 shall be conspicuously posted with a sign or signs bearing the radiation caution symbol and the words CAUTION or DANGER, RADI0 ACTIVE MATERIAL and that each container of licensed material shall have a durable, clearly visible label identifying the radioactive contents...
Contrary to the above on May 17,1983, a 55 gallon drum contain-ing greater than 10 times the 10 CFR 20 Appendix C quantity of licensed material was located in an area which was not radiolog-ically controlled or posted as containing radioactive material.
Furthermore, the 55 gallon drum containing the licensed material did not have a label identifying its radioactive contents."
8308230166 030809 l
DR ADOCK 05000348 PDR 1
l
/
Mr. R. C. Lewis Page Two July 28, 1983 Admission or Denial The above violation occurred as described in the subject report.
R_e_ason for Violation This violation was due to personnel error. Health physics personnel failed to detect the radioactivity during routine surveys. Since the radiation level in the drum was low, it may have been masked by disposable demineralizers which were staged for shipment on the bulk loading pad.
It could not be determined how radioactive material was placed in the drum; however, someone may have poured a small amount of contaminated liquid into the dry cement since only the upper 10% was contaminated.
Corrective Action Taken and Results Achieved The drum was transferred immediately to a Radiation Controlled Area and labeled properly.
Corrective Steps Taken to Avoid Further Violations Unnecessary waste containers such as 55 gallon drums will be surveyed and expeditiously removed from the bulk loading pad following use. All health physics technicians will be reinstructed on the importance of iden-tifying radioactivity during clean area surveys, especially where back-ground radiation is appreciable. Signs will be posted at gates to the Main Power Block Protected Area requiring that materials and equipment be inspected by Health Physics pricr to release.
All corrective action is scheduled to be completed by July 31, 1983.
Date of Full Compliance May 17, 1983 Affirmation I affirm that this response is true ana complete to the best of my knowledge, information and belief.
The information contained in this letter is not considered to be of a proprietary nature.
Yours very truly, F.
. Clayt
, J r.
i FLCJ r/KWM: nac/G-16 xc: File