Text
o-o.
Harry Tauber Group Vice President Deholt Edison Eni!!==
May 3, 1983 EF2 - 63,882 Director of Nuclear Reactor Regulation Attention: Mr. B. J. Youngblood, Chief Licensing Branch No. 1 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C.
20555
Dear Mr. Youngblood:
Reference:
(1) Enrico Fermi Atomic Power Plant, Unit 2 NRC Docket No. 50-341 (2) Letter, W. F. Colbert to L. L. Kintner, EF2-58,782, " Post Accident Sampling Analytical Procedures", dated July 7, 1982
Subject:
Summary of Post Accident Sampling Analytical Procedures Our letter of July 7, 1982 committed to provide a summary of Fermi 2 Post Accident Sampling Analytical Procedures. The type of analysis, equipment, suitability, range, and analytical method are attached to this letter.
Edison regard.- this information to be complete.
If you have any questions, please contact Mr. Larry E. Schuerman (313) 586-4207.
Sincerely, f
i
/I'*
cc: Mr. P. Byron Mr. D. Lynch 30 01 8305100119 030503 PDR ADOCK 0500034
+ -... -.. -.
f ANALYSIS EQUIPMENT
. SUITABILITY '*
RANGE &
METHOD ACCURACY
'l.
Boron Hach Kit Model VerifiedLSuitable Carminic Acid.
1000 + 50. ppm i
DR-1 Colorimeter by GE Testing and i
in the standard chemical test matrix by Detroit Edison 2.
Chloride 1.
Dionex 2020-I NRC Study by Exxon 1.
Ion Chromato-
'0.5 to 20 + 10%
graphy (Off 1< 0.5 +.05 ppm 2.
Selective Ion Site by Babcock Electrode and Wilcox) 2.
For Plant Com--
parison Analysis s
3.
pH Corning Model 135 Verified,by GE and pH probe 5 to 9 + 0.3 pH pH meter with Micro-Detroit Ed ison
< 5 or T 9 + 0.5 pH electrodes MI-410 probe 4.
. Conductivity GE PASS conductiv-Verified'by NRC Direct measurement 0.54 - 2.0 + 10%
ity meter /conduc-Exxon study and by inline conductiv- > 2.0 + 20%-
l tivity. Cell (in-by GE ity cell.
line)
I 5.
Radiochemical PGT Intrinsic Ge Standard.use in Spectral Analysis-Within a factor of Gross Garma De tec tor / Nuclear industry two across the entire Isotopic Data 6600.
range.
6.
Oxyg en N/A - See Item 7.
Based on a positive 1.
Positive hydro-0.5 - 20 ppm + 10%
hydrogen residual gen residual as
< 0.5 + 0.05 ppm
> 10cc/kg.
Hydrogen determined by 4
determined by gas gas chromato-chromatography graphy 2.
Indigo Carmine J
(when ALARA permits) 7.
Hydrogen Perkin Elmer Verified through Gas Chromatography
<50 + 5ec/kg/kg i
Sigma 3B or testing by Babcock 2000 + 40 cc Varian 3760 and Wilcox'on TMI 4
samples.
l
- - Suitability is determined thru testing, utilizing the standard chemical test matrix or by testing in a similar or accident environment. -
l C
t 4.
i