Forwards Response to 830202 Request for Addl Info Re NUREG-0737,Item II.F.1.6, Containment Hydrogen Monitor. Info Re Water Level Monitors to Be Provided by 830615
ML20073R552
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 05/02/1983
From: Bayne J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: Vassallo D
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.F.1, TASK-TM JPN-83-38, NUDOCS 8305040311
Download: ML20073R552 (3)


Text

-

POWER AUTHORITY OF THE STATE OF NEW YORK t o COLUMeus CIRCLE N EW YORK, N.Y.10o19 (212)397-6200 LEROY W. SINCLAsR

  • "E *'. *,'E *o,*.".c".".

TRUSTEES o..

JOHNS.DYSON WALTER T. KICINSK4

""*' '4','J.",',*.

oUd.'.

cEoxoE L. iNoALLS May 2, 1983

,,,,,,,,,c,,,,,,

JPN-83-38

,,=;;..,.a oCNARo M. revNN J AMIS L. LAROC+; A STEPHEN L. BAUM 7tOLLAND E. KIDOER UsaN.YcEse's's o

Director of Nuclear Reactor Regulation U.S.

Nuclear Regulatory Commission Washington, D.C.

20555 Attention:

Mr. Domenic B. Vassallo, Chief Operating Reactor Branch No. 2 Division of Licensing

Subject:

James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 NUREG-0737 Post-?MI Requirements Item II.F.1.4 Containment Pressure Monitor Item II.F.1.5 Containment Water Level Monitor Item II.F.1.6 Containment Hydrogen Monitor

References:

1.

NRC letter, D.B. Vassallo to L.W.

Sinclair, dated February 2, 1983.

2.

PASNY letter, J.P.

Bayne to D.B. Vassallo, dated April 8, 1983 (JPN-83-23).

Dear Sir:

In Reference 1 the NRC requested extensive additional information concerning the subject modifications.

The Authority responded to this request in Reference 2 and committed to provide the following information: pressure monitor response time and accuracy; water level monitor accuracy; and, hydrogen monitor accuracy and location.

l contains information on the hydrogen monitors.

Information concerning the pressure and water level monitors will be provided to you by June 15, 1983.

If you have any questions, please do not hesitate to contact Mr. J.A.

Gray, Jr. of my staff.

ON Vqry truly yours, 0)q.

/

s.

"E'xecutiveVi]cePresident J.,P. Bayne Nuclear Generation cc:

Attached 8305040311 830502 PDR ADOCK 05000333 p

PDR

cc:

Mr. J. Linville Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 136 Lycoming, New York 13093 l

l t

e POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT ATTACHMENT 1 TO JPN-83-38 DATED May 2, 1983 The accuracy of containment hydrogen monitors is i 5% of full scale.

The monitors are set on a scale of 0-10%, and they also have the capability to be set for 0-30% hydrogen concentration.

The system consists of two redundant trains each capable of obtaining samples from three locations in the primary containment, one location in the suppression chamber, and one location in the reactor building.

Sample locations for both trains are:

1.

Drywell lower level El.276'-6" 2.

Drywell mid level El.310'-6" 3.

Drywell upper level E1.343'-6" 4.

Suppression chamber El.250'-3" 5.

Reactor building El.300'-0" The twc hydrogen analyzers are located on Elevation 300'-0" of the Reactor Building.

The sample point locations for H sample lines in the drywell and suppression pool have been select 3d to adequate indicate the concentration level of hydrogen in the containment.

These locations are representative of the drywell area.

l 1

e I

l l

l