ML20073K292

From kanterella
Jump to navigation Jump to search
Informs of Change in Commitment Related to Item of Noncompliance 84-12-02.TOED re-evaluated Position Re Ongoing Commitment & Determined That Maintaining Procedure DB-ME-09805 No Longer Necessary for Listed Reasons
ML20073K292
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 10/03/1994
From: Stetz J
CENTERIOR ENERGY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
1-1052, NUDOCS 9410110139
Download: ML20073K292 (2)


Text

.

CENTERIOR ENERGY 300 Madten Annue Toledo, OH 43652 0001 Vice President - Nuclear 419-249-2300 Davis-Besse Docket Number 50-346 1,1 cense Number NPF-3 Serial Number 1-1052 October 3, 1994 United States Nuclear Regulatory Commission Document Control Desk Vashington, D. C.

20555 Subj ec t :

Change in Commitment Related to item of Noncompliance 84-12-02 Gentlemen:

In a Nuclear Regulatory Commission (NRC) inspection report dated August 14, 1984 (IR 84-12), Toledo Edison was issued a Notice of Violation regarding, in part, the subject item of noncompliance.

Item 84-12-02 involved electrical junction boxes which were not maintained in accordance with station drawings and vere consequently adequately protected from an actuation of the fire protection not sprinkler system.

Toledo Edison responded to the Notice of Violation by letter dated September 20, 1984 (Serial 1-463).

Corrective Actions described in this response included the development of procedure IC 2601.04, Fire Shield and Spray Procedure.

Procedure IC 2601.04 was eventually renumbered DB-ME-09805, Spray Shield and Spray Barrier Inspection.

Procedure DB-ME-09805 is required to be performed after each refueling outage or af ter vork is performed on equipment subject to the procedure.

Toledo Edison has re-evaluated its position regarding this ongoing commitment and has determined that maintaining DB-ME-09805 is no longer necessary based on the following:

(1) The amount of modification activity and number of contract employees have significantly decreased since the timeframe in which NRC identified deficiencies in spray shield maintenance at Davis-Besse.

l I

? '

s,,

a Lw.. G fh Operatmg Compon,es Toledo Ec: son 9410110139 94100',

p 'G Cleveland Electoc lilummotmg l

FDR ADocy 05000546

(

POR

Docket Number 50-346 License Number NPF-3 Serial Number 1-1052 (2)

  • The information in DB-ME-09805 is strictly a reprint of the information contained in station drawing M-269 vhich provides i

adequate guidance for equipment restoration upon completion of maintenance on spray shields.

(3)

Performance monitoring programs, the experience level of individuals performing work on spray shields and increased emphasis on attention to detail provide assurance that spray shields are appropriately maintained as a normal work practice.

(4)

During the last complete performance of DB-ME-09805, approximately 338 spray shields / barriers were inspected.

Only two minor deficiencies were identified, neither of which braached the spray shield / barrier.

Based on the above, Toledo Edison intends to cancel DB-ME-09805 and close the associated ongoing commitment in the Toledo Edison Regulatory Management System (TERMS). This issue has been discussed with the Davis-Besse Senior Resident Inspector.

Should you have any questions or require additional information, please contact Mr. Villiam T. O'Connor, Manager - Regulatory Affairs, at (419) 249-2366.

Very truly yours, qvtl l

~

i AVA/ eld cc:

L. L. Gundrum, NRC Project Manager J. B. Martin, Regional Administrator, NRC Region III S. Stasek, DB-1 NRC Senior Resident Inspector Utility Radiological Safety Board

..