New Jersey Pollutant Discharge Elimination Sys Discharge Monitoring Rept for Aug 1994 for Hope Creek Generating Station
ML20073F574
Person / Time
Site: Hope Creek 
Issue date: 08/31/1994
From: Hovey R
Public Service Enterprise Group
To: Caporale G
NEW JERSEY, STATE OF
References
NUDOCS 9410030163
Download: ML20073F574 (24)


Text

.

D PSEG

~

Pubhc Service Electnc and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038 Hope Creek Generating Station September 22, 1994 Chief George Corporale Bureau of Information Systems P. O.

Box CN-029 Trenton, N. J.

08625 RE:

NEW JERSEY POLLUTANT DISCHARGE ELIMINATION SYSTEM DISCHARGE MONITORING REPORT HOPE CREEK GENERATING STATION NJPDES PERMIT NJ0025411

Dear Sir:

Attached is the Discharge Monitoring Report for the Hope Creek Generating Station for the month of August 1994.

This report is required by and prepared specifically for the Environmental Protection Agency (EPA) and the New Jersey Department of Environmental Protection and Energy (NJDEPE). It presents only the observed results of measurements and analysis required to be performed by the above agencies. The choice of the measurement devices cnd analytical methods are controlled by the EPA and the NJDEIE, not by the company, and there are limitations on the accuracy of such measurement devices and analytical techniques even when used and maintained as required. Accordingly, this report is not intended as an assertion that any instrument has measured, or that any reading analytical result represents the true value with absolute accuracy, nor is it an endorsement of the suitability of any analytical or measurement procedure.

If you have any questions concerning this report, please feel free to contact Mr.

C.

E. White.

Sincerely, i

Robert J. Hotey General Manager -

Hope Creek Operations o p,;,,, g (.

O.Lt 4

h The Energy People 9410030163 940931 PDR ADOCK 05000354 95 2173 (2SM) 12-69 I

PDR p

.NJPDES 2

9/22/94 k

SW:eaj Attachments C

Executive Director, DRBC USEPA - Dr. Richard Baker USNRC

09-13-1934 83250PM FROM STPRfD NOMT 50_UTIONS 184B TO 3393546 P.01 e

e s :.

Strand Management Soldti6ns,Inc.

569 Abbington Drive

'i '.;

1

~ ' ; !(~fj9) 448-1200 East Windsor, New Jersey 08520 ;~ Fd ;BBSf (609) 448-2642 Ms. Debra Hammond Chief, Bureau of Permit Management Wastewater Facility Regulation P.O. Box CN029 Trenton, N.J. 09625 December 11, 1992

Dear Ms. Hammond:

I am enclosing copies of our laser-generated Discharge Monitoring

' Report (DMR) and Indtistrial Process Wastewater Sludge Report (IPWSR) forms, as we discussed on the telephone today. We foresee using these forms for the following permit holders:

DMR NJ0000621 PSEEG Bergen Generating Station NJ0000639 PSEEG Econx Generating Station NJ0000647 PSEEG Hudson Generating Station NJ0000655 PSE&G Kearny Generating Station NJ0000663 PSEEG Linden Generating Station NJ0000600 PSE&G Sewaren Generating Station NJ0003603 PSEEG Edison Generating Station NJ0004995

.PSEEG Mercer Generating Station NJ0005002 PSEEG Burlington Generating Station NJ0005045 Monsanto Delaware River Plant NJ0005622 PSEGG Salem Generating Station NJ0025411 PSEEG Hope Crcck Generating Station IPMER 0000663 PSEEG Linden Generating Station We will inform you in like manner of permittees se may wish to add in the future. Please indicate your acceptance by signing and returning this letter or a copy.

Very truly yours, Strand Management Solutions, Inc.

Y. Is f for~v -

Arnold S. Rosner Vice President J%f%-

Defara Ann Bamusn'd Dat&

/

Chief, Bureau of Permit Management

09-13-1934 23:50PN FROM STPff 0 Nrf.T SCLUTIONS lHB TO 3393546 P.02 Strand Management Solutions,Inc.

l 569 Abbington Drive (609) 448-1200 East Windsor, New Jersey 08520 Fax - BBS: (609) 448-2642 l

Ms. Debra Hanunond Chief, Bureau of Permit Management Wastewater Facility Regulation P.O. Box CN029 l

Trenton, N.J. 08625 May 13, 1993 l

l

Dear Ms. Hammond:

In order to increase readability of the " consent" section of our laser generated DMR's, we would like to remove the following text from the forms COMMENT AND EXPIANATION OF ANY VIOLATIONS (Reference all j

attachments here)

I am anclosing a copy of the formi incorporating our suggested modification.

We will use this form for the following permit holder:

NJ0005045 Monsanto Delaware River Plant Please indicate your acceptance by signing and returning this letter I

or a copy.

i very truly yours, StrandManaggeentSolutions, Inc.

7['ldS.Rosner

. 0 f. %s n Arno Vice President l

Ad]ha L bbsnann) sh/c

\\

Debra Ann Hazamond Date Chief, Bureau of Permit Management TOTAL P.02

1 F m T.vwx eta NEW JERSEY DEPARTMENT CF ENVIRONMENT Al. PROTECTsON sis 3 Olvis ON OF WATER RESOURCES MONITORING REPORT - TR ANSMITTAl. SHEET NJPOES NO.

R EPORTING PERIOD wo.

v a.

.. v s.

l01012 51 4r 11 1]

l018 l9 I4 l THRu l0 l8 l9 ;4 l

{

{

Public Service Electric & Cas Company PE RMITTE E:

Name Address P.O. Box 236 j

Hancocks Bridoe, NJ 08038 F ACf LITY:

Name trope creek Generatino Station

]

i Address P o-Rav ~> 16 I

truencke n r 4 ri e, ET (Countyl c:n 1.

Telephone (609 I 339-3463 FORMS ATTACHED (Indicste Quantity of fach)

OPE R ATINC.EXCE PTIONS YES No SLUDGE REPORTS. $ANITARy T VWX 007 T VWX 008 T VWX 009 DYE TEST'"G Q

TEMPORARY SYPAs$8NG C

h I

$LUDGE REPORTS. sNDUSTRIAL l

DislNF ECTION INTERRUPTS 0N C

h T VWX 010A T.VWX 0100 g

g WASTEWATER REPORTS UNITE OUT OF OPERATION C

T.vwX 011 T VWX-012 l lTvwx013 oTHER C

l' GROUNOwAT ER REPORTS (Desa>1sny "Yes**on teserse side

]vwx 015(A.8) ]VWX 016 VWX 017 l

NPDES OgsCHARGt MONITORtNG REPORT NOTE: The ~ Hours Artendeder?lant**on the reWrse o[lhis ahtel must also be completed.

gp p y

AUTHENTICATION

  • l certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments and that, based on my inquiry of those individuals immediately responsible for obtaining the information. I believe the submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment.

t.lCENSE D CPERATOR PRINCIPAt. EXECUTIVE OFFICER or DUt.Y AUTHORIZED REPRESENTATIVE Robert J. Hovey Name (frinted/ Christopher E. White y,m,gp,jn,,j General Manacer

(]

H pe Creek operations

, I1;2 ),N(f956 # )

Titte ter-Grade & Reg;,

)

Signature er 3;,,,,,,

9/22 4 9 20/94 Date.

Cate

OPER ATING EXCEPTIONS DETAILED Please refer to the attached Transmittal Sheet Addenda.

HOURS ATTENDED AT PLANT Month M year M Day of Month 1

2 3

4 5

6 7

8 9

10 11 12 13 ' 14 15 16l Licensed operator 7.5 13.3 8 8

8 8

8 8

8 8

8 8

Othets 1 01 10 10 10 10 3

3 10 10 10 10 10'3 3 LO. 10 Osy of Month 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Licensed Operator 8

8 8

8 9

10 8

8 8

9 8

Other:

10 10 10 3 3

10 10 10 10 10 3

3 10 10 10

4 OPER ATING EXCEPTIONS DETAILED Please ref2r to the attached Transmittal Sheet Addenda.

1 l

HOUR $ ATTENDED AT PLANT Month Year Day of Month 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 Ucensed Operator 7.5 13.3 8 8

8 8

8 8

8 8

8 8

Others 10 10 10 10 10 3

3 10 10 10 10 10 3 3

LO 10 Dey of Month 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Ucensed Operator 8

8 8

8 9

10 8

8 8

9 8

Other:

10 10 10 3 3

1010 10 10 10 3

3 10 10 10 4

i

OlVISION OF WATER RESOURCES MONITORING REPORT - TRANSMITTAL SHEET NJPOES NO.

REPORTING pef:sOO l0101215l41111l lOlFRl41 TNRu p gg A PE RMITTE E:

Name Public Service Electric & Cas Company Address P.O. Box 236 Hancocks Bridge, N.J.

08038

~

FACit fTY:

Name Hope Creek Generating Station Address P.O. Box 236

_Hancocks Bridste. N.J.

(County)

Salem Telephone (609 1

119-1ti A 1 FORMS ATTACHED (lnd/cuse Quantirr of fach)

OPERATING EXCEPTIONS SLUDGE REPORTS. SANITARY YES No T.VWX-007 T VWX 008 T.VWX 409 DYE TESTING C

E st.UDGE REPORTS. sNousTRsAL OfSINF ECTION INTERRUPTION O

3 0T-VWX 010A T.YWX.010B MONITORING MALFUNCTIONS b

O WASTEWATER REPORTS UNITS OUT oF OPERATeoN O

E T.VWX 011 T VWX 012 T.VWX413 oTHER O

O GROUNowATEn REPORTS

~

(Desasiany "Yes **on reverse side VWX 015(A,B)

VWX 016 VWX.017 NPDE$ OtsCHARGE MONETOntNG REPORT NOTE The **) fours Attendeder Pknt**en the EPA FORM 33201 AUTHENTICATION. I certify under penalty of law that l'have personally examined and am familiar with t'he information submitted in this document and all attachments and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and ccmplete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment.

LICENSED CPERATOR PRINCtPAL EXECUTIVE OFFICER or DULY AUTHORIZED REPRESENTATIVE Name (Printedi./f/1 l_

.YV Name(Printed)

Robert ]

E0**Y General Manager Goade & Registry No.

S-4 Title (Print Hope Creek Operations 6 d @<

s;,n.to,e I/ b/ )

si,naio,e f ///

Date.

9/22/94 Date

i v o

's w nti.v v; os 1 si A1:N(. I x( t I 1 TONS. Lil,1 AlL I D

~-$

0 - -._

S. !

.0

.-- M b W

."..Y.

a b-

---. A L.. W &

_.._Ye%l. WMY lm.fC Seak c& Q J'. A A ~p:b sE9_

8O f.A $ d/

'. e b< a

& V-e _

m sh e

/

l l

l HOUR $ ATT E NDE D AT PLANT Month b Year Day oi Month 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16' Uttnsed Operator f S h h

b f b ] [ [ } [

$ 8 I

Others

[

8.-.

l Day of Month 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Ucensed Operator

} $ 8 f

} } } } $

f f f Others 7

f S

k 1

t

' W'" "'"''U*C CH'l 88 ^1)N(.,1 x ( t I 1lONS 1II 1 AIL t D 0 0 ~~.-

$ l

.h M.

.0

~

_ b W _.W.----

b

-.AL. A ' " =^ ' &

41h A %.?.a W V M &

~,A.w,S.'*"'.

G

&l] ' -

n &f/ aN&

I (1

/

/

/

AO

(.4 % sid A.

Au f M/ d_e 2A a

ms s

HOURS ATTE NDED AT PLANT Month bb Yese $Y1 Day of Month 1

2 3

4 5

6 7

8 9

to 11 12 13 to 15 16 Ueensed Operatot

[ h [

8 3 7 3 8 7 8 8 7

$ 8 Others 8

8 Day of Month 17,18 19 20 21 22 23 24 25 26 27 28 29 30 31 Utensed Operator f h 8 [

[ ] f f 8 f

h f Others 7

k 8 4

i NJPDES 9/22/94 Explanation of conditions August 1994 The following explanations are included to clarify possible deviation from permit conditions.

General - The columns labeled "No. Ex",

on the enclosed DMR, tabulate the number of daily discharge values outside the indicated limits.

Data reporting and accuracy reflect the working environment, the design capabilities and reliability of the monitoring instruments and operating equipment.

Analytical values performed by the following NJDEPE certified laboratories:

NET Atlantic, Inc. (08153)

Hope Creek Generating Station (17451)

Talbot Laboratory, Inc. (77535)

South Jersey Testing, Inc. (06431)

Princeton Testing Laboratory, Inc. (11118)

Deviations from required sampling, analysis monitoring and reporting methods and periodicities are noted on the respective transmittal sheet.

Frequency for discharge point 461A, the cooling Tower Blowdown, and the River were done at approximately 5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> intervals to provide for the cycles of concentration in the system.

As per the Administrative Consent Order the TSS limit for discharge points 462A, 463A and 464 have been lifted and the interim thermal limits for discharge point 461A have been changed to 443 MBTU/hr (June - September) and 731 MBTU/hr (October - May).

Results reported on the Discharge Monitoring Report forms are consistent with permit limits, data supplied from contract laboratories, the December 1993 revision of the NJDEPE DMR Instruction manual and specific guidance from DEP personnel.

Please note the use of the laser generated style of EPA form 3320-1. This format is now being used at Hope Creek and a copy of the letter indicating NJDEPE acceptance is included for your reference.

4 ADDENDA TO MONITORING REPORT - TRANSMITTAL SHEET f

DISCHARGE NUMBER i

PAGE PARAMETER COMMENTS 461A NOTES Net values calculated from grab samples.

2 of 5 00665 2 1 00680 2 1 i

461C I

Samples obtained were composites in 1 of 2 00680 1 1 accordance with permit requirements.

i 4

0 U

b i

NJPDES 9/22/94 Explanation of Exceedances August 1994 I

The following exceedances are included in the attached report and explained below. Exclusions have not endangered nor significantly impacted public health or the environment.

DSN No.

EXPLANATION No Exceedances i

l i

= _ _

P COUNTY OF SALEM STATE OF NEW JERSEY I

I, Robert J. Hovey, of full age, being duly sworn according to law, upon my oath depose and Psy:

i i

1.

I am the General Manager of the Hope Creek Generating Station, and as such am authorized to sign Discharge Monitoring Reports submitted to the New Jersey Department of Environmental Protection pursuant to the Station's New Jersey Pollutant Discharge Elimination 4

System permit.

2.

I certify under penalty of law that I have personally examined and am familiar with the information submitted

{

in this document and all attachments and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment.

3.

The signature on the attached Discharge Monitoring Reports is my signature and I am submitting this affidavit in satisfaction of the requirement that my signature be notarized.

f 1,

Y I

l Robert J. Hovey General Manager -

Hope Creek Operations Sworn and subscribed be(ore me this gg day of pg11994 Ib

\\%

(471% )

<-=

D' EHm!!..HUSTOM N2fARY FU5L10 CF KES JSSE1,j 35y Cec:::ission Er$as D,c.30,199Y l

SYSTEM (NPDES)

PERMITTEE NAME/ ADDRESS NATIONAL g

j Igr I

NAME P!;E erg (2-16-)

b-19)

ADDiESS P.O.

BOX 23_6fN_21 NJOO25411 461A HANCOCKS BRIDGEnNJ 08038 PERMIT NUMBER DISCHARGE NUMBER MONITORING PERim COOLING TOWER BLOWDOWN i

YEAR M0 DAY YEAR Mo DAY MAJOR SALEM bC_iT{P1EFG }O[E3R1E[ G]N[RA]IlG]ST}T[ON,,,

toCAftoN LOWER ALLOWAYS CREEK NJ 08038 94 08 01 94 08 31 SOUTHERN REGION n

DMR NUMBER: 081994 (20-21)(22-23)(24-25)

(26-27)(28-29)(30-31)

QUANT LOADING (4 C y)

QUAL CONCENTRAT

=,

(3 C g g y)

EX OF SAMP E PAgMgER W WW5 (66d)

(

)

UNnS UNnS TEMPERATURE, WATER 29.7 32.8 OCONTI)f h0US MEASURkE SAMP MENT DEG. CENTIGRADE

REPORT a 3 5.~ 6 DEG.C i i.CONTI)I J 30010 1

1 pg,,g -

EFFLUENT GROSS VALUE ' REQUIREMENT-

'MNTH? AVG tDLY? MAX

'JOUSE TEMPERATURE, WATER 26.6 28.0 OCONTIFi MEASURk,ENT 3,,

1]OUS M

DEG. CENTIGRADE

';CONTI)!:

00010 7

1

=******

. REPORT

? REPORT DEG.C pg g INTAKE FROM STREAM

' REQUIREMENT'

.MNTHEAVG 2DLY4 MAX

'JOUS2 a

8 8

OTWICE/

GRAB PH WEEK MEk R ENT pg,,g,

9 SU 4 TWICE/ GRAB; 00400 1

O 1******- ****

' 6' x******

._5 EFFLUENT GROSS VALUE REQUIREMENT:

vMINIMUM

' MAXIMUM MEEKF SOLIDS, TOTAL 94 130 OTWICE/

GRAB SAMPLE (ONTH SUSPENDED MEASUREMENT s

s tREPORT s EMRT MGS yM/BM t;

?mm 00530 1

0 PERMtiv EFFLUENT GROSS VALUE REQUIREMENT:

EMNTHsAVG 1DLYiMAX H40 NTH SOLIDS, TOTAL 66 95 OTWICEj CALCTD MEASURkg

](ONTH MENT SUSPENDED 00530 2

0 1******

C****** ****

h******

2VREPORT

,? REPORT MG/L lTWICE/ CALCTD pg,,g.

EFFLUENT NET VALUE REQUIREMENT..

&MNTHNAVG sDLYAMAX il(ONTH SOLIDS, TOTAL 28 35 OTWICEj GRAB

)(ONTH MEk R ENT SUSPENDED r******

2******

1******

EREPORT sREPORT MG/L 4TWICE/ GRABM 00530 7

0

pg,gg iMNTH3 AVG

!DLYsMAX L)(ONTH INTAKE FROM STREAM

'REQUIREMENTb

< 0.20

< 0.20 OTWICEj GRAB HYDROCARBONS,IN H20, SAMPLE

)(ONTH IR,CC14 EXT. CHROMAT MEASUREMENT J******

^1 REPORT MREPORT MG/L y(L'WICE/'GRABJ 00551 1

0

!PERMn 4 -

ONTH EFFLUENT GROSS VALUE REQUIREMENE (MNTHEAVG tDLY2 MAX H

y EXAMI g 7

TELEPHONE DATE L

I S

NAME/ TITLE PRINCIPAL EXECUilVE OFFICER QEgigi AWyA hg1 g

ONfJ, gu,.gIIR g

Da

(

ROBERT J.

HOVEY r

HE E i

~

509 339-3463 94 09 22 h E! A gs CC A

GENERAL MANAGER J

su

\\I H_ OPE CREEK OPERATIONS or maxmm inpNment of between 6 months and $ yea $.$o AUkCHOR2DAGkN ARbA NUMBER YEAR MO DAY (Pena e

at s

nclude f s"

F U

0,bb0 C0 E TYPED OR PRINTED l

IF CR IS REQUIRED ONLY IF MAINTENANCE CHEMICALS CONTAINING THESE METALS ARE USED.

SAMPLING FOR CO, ZN, E l

NOT USED, ENTER " NODI" FOR THESE METALS.

EPA Form 3320-1 (Rev. 9-88) Previous editions may be used.

LABS: 08153 17451 77535 06431 11118 PAGE 1 OF 12 m

SYSTE;1 (rPDES)

(b N)Tji g f g gl g g b -19)

PERMITTEE CAME/ ADDRESS

'ATION*.L T

CAME PSE&G ADD;ESS P.O.

BOX 236/N_21 NJ0025411 461A HANCOCKS BRIDGE NJ 08038 PERMIT NUFBER DISCHARGE M MBER n

MONITORING PERIOD COOLING TOWER BLOWDOWN FtCILITY PSEEG HOPE CREEK GENERATING STATION YEAR MO DAY YEAR MO DAY MAJOR SALEM toCATic: LOWER ALLOWAYS CREEK NJ 08038 94 08 01 94 08 31 SOUTHERN REGION n

DMR NUMBER: 081994 (20-21)(22-23)(24-25)

(26-27)(28-29)(30-31)

(3 cgg.ggiv) =^=Tig.%to^ot"o

('cgg.giv)

=^'ig.gg)mact=Ta* Tin.63)

No

,,go.

E

"$$75N" AwA{Nts(6 N )

Ex UNITS UNITS (64-

)

< 0.2

< 0.2 OTWICE/ CALCTD 5[YDROCARBONS,IN H20, IR,CC14 EXT. CHROHAT MEASuRkg 3,,

MENT

](ONTH 00551 2

0

~******

?******

SREPORT

.., jl0 MG/L 5TWICE/ CALCTD pg,, g.

EFFLUENT NET VALUE REQUIREMENT-

^MNTHSAVG

>DLY! MAX

]4ONTH HYDROCARBONS,IN H2C'

< 0.20

< 0.20 OTWICE/

GRAB Supa IR,CC14 EXT. CHROMAT MEASUREMENT

](ONTH 1******

2******

{ REPORT fREPORT MG/L

-ytWICEj GRAB.;

00551 7

0 spg,g -

.MNTHVAVG

?DLY} MAX

!: MONTH INTAKE FROM STREAM REQUIREMENT-:

PHOSPHORUS, TOTAL 0.14 0.16 OKWICE/

GRAB 3,,

y (AS P)

MEASUR MENT MONTH 1 REPORT

REPORT MG/L jTWICE/ GRABj 00665 1

1

/*.*****

q*****

HhNTH) AVG

?DLY6 MAX H(ONTH pg,, g EFFLUENT GROSS VALUE

'REQUIREMENTT PHOSPHORUS, TOTAL 0.04 0.06 OTWICE/ CALCTD 3,,,

(AS P)

MEASUR ENT

](ONTH **

e******

t******

REPORT

. ; y REPORT. MG/L

'4TWICEj GRABh 30665 2

1

..spg,g.

"MNTH7 AVG nDLYsMAX O(ONTH EFFLUENT NET VALUE

' REQUIREMENT 6 PHOSPHORUS, TOTAL 0.10 0.10 OTWICEj GRAB 3,,pg (AS P)

MEASUREMENT

](ONTH F * *.* * *.*

3******

...jREPORT

.; REPORT MG/L STWICE/' GRAB 1 00665 7

1

. pg,g..

INTAKE FROM STREAM

'RtQulREMENTT EMNTHJAVG JDLYTMAX H(ONTH-CARBON, TOT ORGANIC 13.0 15.0 OTWICE/

GRAB 3,,pg (TOC)

MEASUREMENT

](ONTH 00680 1

1 1******

1******

4******

. 7 REPORT

j. REPORT-MG/L

}TWICE/'GRABt pg,g g EFFLUENT GROSS VALUE

'REQUIREMENTE 3MNTHIAVG 4DLY1 MAX H40 NTH CARBON, TOT ORGANIC 6

7 OTWICE/ CALCTD SAMP (TOC)

MEASUR ENT

](ONTH **

00680 2

1

. pg,,g.,.

2****** ****

9******

.. t. REPORT J20 MG/L yEWICEj GRAB) 4******

EFFLUENT NET VALUE

' REQUIREMENT?

MMNTHEAVG lDLY7 MAX M(ONTH TELEPHONE DATE L

RSON YE Igg

'AME/TITIE PRINCIPAL EXECUTIVE OFFICER EylgUg 4

Aglg u

Di E I OR RODERT J.

HOVEY og ygg g

'509 339-3463 94 09 22 hj g

gg E

/

ALCURA AD GEMERAL MANAGER SgthI hND hME U

N J

G:A OF PR GAL HOPE CREEK OPERATIONS

,ND and/or maximtn imprisonment of between Ubths and AU puMIf,D bT yes

.)

CODE NUMBER YEAR MO DAY TYPED OR PRINTED SAMPLING FOR CO, ZN, & CR IS REQUIRED ONLY IF MAINTENANCE CHEMICALS CONTAINING THESE METALS ARE USED. IF NOT USED, ENTER " NODI" FOR THESE METALS.

C*

PLEASE REFER TO THE ATTACHED TRANSMITTAL SHEET ADDENDA EPA Form 3320-1 (Rev. 9-88) Previous editions may be used.

LABS: 08153 17451 77535 06431 11118 PAGE 2 0F 12 l

YSTEM (NPOES) gANT}ls glgg (N-19)

PERMITTEE CA"E/ACCIESS NATICtAL pct (2 N)

NAME P.2EEG ADD;.ESS P.O.

BOX 230/N_21 NJ0025411 461A HANCOCKS BRIDGE NJ 08038 PERMIT NUMBER DISCHARGE WJMBER n

MONITORING PERIOD COOLING TOWER BLONDOWN l

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ATION YEAR M0 DAY YEAR M0 DAY MAJOR SALEM FACILiff PSEEG HOPE CREEK GENERATING ST l

FROM LOCAi!ON LOWER ALLOWAYE CREEKnNJ C8038 94 08 01 94 08 31 SOUTHERN REGION i

DMR NUMBER: 081994 (20-21)(22-23)(24-25)

(26-27)(25-29)(30-31)

CONCENTRAfg QUAL (3Cg,gy) QuANig{,g, LOADING (4 Cg y) 0 SAMP E Eg$ IE@

(6 N >

l PA g ER b3 UNITS UNITS i

CARBON, TOT ORGANIC 6.4 8.1 OTWICEj GRAB 3,,, g MEASURkMENT j(ONTH i

(TOC) 00680 7

1

i******

x******

x******

(REPORT.

,iREPORT MG/L iTWICEj'GRABf j

. pgg g a.

._/MNTHEAVG DLYSMAX N(ONTH INTAKE FROM STREAM REQUIREMENT CHROMIUM, TOTAL SAMP E (AS CR)

MEASUR MENT L******

1******

?******

REPORT

.tREPORT MG/L TWICEj GRAB;s 01034 1

0 3 pggg.

EFFLUENT GROSS VALUE

' REQUIREMENT:

2:MNTH5 AVG

$DLYsMAX N(ONTH CHROMIUM, TOTAL

  • mu mm uuu NN MM 0 WM EM 3,,, g MEASURkMENT (AS CR) 7******

e******

REPORT x:.. _ J 2 MG/L 3TWICE/ CALCTD 01034 2

0 pgggy iDLYAMAX M(ONTH :n

  • MNTHJAVG EFFLUENT NET VALUE

, REQUIREMENT,..

~

CHROMIUM, TOTAL NODI NODI O NODI NODI 3,p g MEASunkMENT (AS CR) 4******

S******

. GREPORT

. CREPORT. MG/L

TWICEj GRABp 01034 7

0 jpg,gg;.

LMNTHVAVG ZDLYTMAX N(ONTH INTAKE FROM STREAM REQUIREMENT, COPPER, TOTAL NODI NODI O NODI NODI SMPLE (AS CU)

MEASUREMENT 01042 1

0

,, pggg3 VREPORT

, (REPORT. MG/L lTWICEj GRAB:$

(******

t***.***

~

EFFLUENT GROSS VALUE

'REQUIREMENTx LMNTHRAVG

?DLYMMAX d(ONTH

~

NODI NODI O NODI NODI COPPER, TOTAL MEASURkgMENT 3,p (AS CU) n******

1*=****

J******

..? REPORT JR, f.2 MG/L fTWICE/ CALCTD 01042 2

0 ypg,gg 5:MNTH9 AVG

?DLY4 MAX

)(ONTH EFFLUENT NET VALUE REQUIREMENT'c-NODI NODI O NODI NODI COPPER, TOTAL 3,ptg (AS CU)

MEASUREMENT 1******

(******

1***_***

_.iREPORT

.4 REPORT MG/L TrWICEj'GRABj 01042 7

0

, pg,gg..

y INTAKE FROM STREAM

. REQUIREMENT 4

'iMNTHnAVG 2DLYCMAX

)(ONTH RS TELEPHONE DATE Ag Y EXAMi g ROBERT J.

HOVEY Og{Jh gg I h@ gig L 0 XAME/ title PRINCIPAL EXECUTIVE OFFICER QE IgN 3

j

}$lD MyDI T

u "oMet i

509 339-3463 94 09 22 g

GENERAL MANAGER G,Jgtg

. gga klE RESg ActVRA AND AN N

P C Al gU HOPE CREEK OPERATIONS EPSI E

0 and/or maxinun inprisonment of between [ months ano d yea $.)

kuHORZ;DAGkN CODE NUM8ER YEAR M0 DAY TYPED OR PRINTED 0

SAMPLING FOR CO, ZN, & CR IS REQUIRED ONLY IF MAINTENANCE CHEMICALS CONTAINING THESE METALS ARE USED. IF NOT USED, ENTER " NODI" FOR THESE METALS.

EPA Form 3320-1 (Rev. 9-88) Previous editions may be used.

LABS: 08153 17451 77535 06431 11118 PAGE 3 0F 1

S STEM (NPDES)

I g g gi g 7f-19)

NATICIAL PO PE1MliTEE EAME/ ADD;ESS

$6)

(

CAME PSEEG NJ0025411 461A ADD %ESS P.O.

BOX 2 3_ 6f_N_21 NJ 08038 PERMIT NUMBER DISCHARGE NUMBER HANCOCKS BRIDGEn MONITORING PERIOD COOLING TOWER BLOWDOWN TEAR M0 DAY TEAR MO DAT MAJOR SALEM

_ _ _ _ _ _ _ _ _ _ _ _ _ TING STATION,

FACILITY PSE&G HOPE CREEK GENERA NJ 08038 94 08 01 94 08 31 SOUTHERN REGION LOCAT104 LOWER ALLOWAYS CREEKn DMR NUMBER: 081994 (20-21)(22-23)(24 25)

(26-27)(28-29)(30-31)

QUANT LOADING (4Cg y)

QUAlg CGdCENTRATg

,=

(3 C g g y)

=

k62 ANA TSIS TP k

UNITS

63) (64-68)

(69-7u)

UNITS

=

=

ZINC, TOTAL SAMPLE (AS ZN)

MEASUREMENT tWICEj GRABf

. REPORT MG/L

,.fREPORT p

01092 1

0 EFFLUENT GROSS VALUE REQUIREMENT' tMNTHiAVG DLYAMAX

' MONTH PEm!T.

NODI NODI O NODI NODI ZINC, TOTAL 3,,,tg (AS ZN)

MEASUREMENT

. e J. 6 MG/L ftWICEj CALCTD 01092 2

0

.,,,g 1******

EREPORT EFFLUENT NET VALLB REoVIREMENT TMNTH-JAVG DLYAMAX CMONTH NODI NODI O NODI NODI ZINC, TOTAL

,,g (AS ZN)

MEASUREMENT 2

t******

1******

,LREPORT

.LREPORT MG/L

$'tWICE/' GRAB) 01092 7

0

'MNTHEAVG

!DLYiMAX tMONTH' 4 pep T INTAKE FROM STREAM REQUIRkMENT

+

            • <0.000004

<0.000004 0'EWICEj GRAB ASBESTOS (FIBROUS) 3,,p

](ONTH MEASUR ENT T****** ****

REPORT jREPORT UG/L 3'tWICE/ GRAB; 34225 1

0 PEntF 'P iMNTH4 AVG 3DLYJMAX c: MONTH REQUIREMENT EFFLUENT GROSS VALUE

            • <0.000004 <0.000004 0'tWICEj CALCTD ASBESTOS (FIBROUS)

MONTH ME R ENT 1******

1. REPORT

.tREPORT UG/L

  • ' tWICE/ CALCTD 34225 2

0

. pg, 3.y.

SMONTH EFFLUENT NET VALUE tREDUJR MENT.

sMNTH9 AVG

?DLYTMAX

            • <0.000004 <0.000004 0'tWICE/ GRAB ASBESTOS (FIBROUS)

MONTH 3,,

MEASUR ENT 1******

EREPORT EREPORT UG/L n.'tWICEj'GRABJ 34225 7

0

,gn UMNTHEAVG 3DLYlMAX iMONTH!

~"

INTAKE FROM STREAM REQUIREMENb FLOW, IN CONDUIT OR 44.54 84.66 OCONTIN 3,pt,

'JOUS THRU TREATMENT PLANT MEASUREMENT l:D)NTIN3 50050 1

0 pggy(

.CREPORT jREPORT'MGD 3 * * *.*.* *

,f*'*','~**'*"*"

EFFLUENT GROSS VALUE Rt0VIREMENT4 1MNTH? AVG 5DLYiMAX

^

NJOUSS QEgigtg Lg 0 LAWyAgig g

Y EXAMi g i,f*

TELEPHONE DATE EME/ TITLE PRINCIPAL EXECUTIVE OFFICER IL

)

gggu g ggg,h ygmyg ggg ROBERT J.

HOVEY iy _

509 339-3463 94 09 22 GENERAL MANAGER

{8%f $

Ih^YoR'EblINij UtN"I mag b

i 0,N HOPE CREEK OPERATIONS

. (Pe e u t

e at s

s F

AREA Ubb0 and/or maximum inprisonment of between UncMs(ude fh yea'up to AUhCMOR 2 D AG N CODE NUMBER TEAR M0 DAY and rs.)

TYPED OR PRINTED IF SAMPLING FOR CO, ZN, E CR IS REQUIRED ONLY IF MAINTENANCE CHEMICALS CONTAINING THESE METALS ARE USED.

NOT USED, ENTER " NODI" FOR THESE METALS.

EPA Form 3320-1 (Rev. 9-85 34rvious editions may be used.

LABS: 08153 17451 77535 06431 11118 PAGE 4 0F 12

KATIC:!AL POgUTANiglggigigSYSTEM (KPOES)

PERMITTEE NAME/ ADDRESS h $$)

NIf19) t*E PSEEG ADDRESS P.O.

BOX 23_6/N_21 NJ0025411 461A HANCOCKS BRIDGE NJ 08038 PERMIT NUMBE2 DISCHAIGE NUMSE2 n

MONITORING PERim COOLING TOWER BLOWDOWN NU U

~

3C5T{P1E{G}O[E3R[E{G]N[RA3I[G]ST}T[ON FRoM To LoCu loN LOWER ALLOWAYS CREEK NJ 08038 94 08 01 94 08 31 SOUTHERN REGION n

DMR NUMBER: 081994 (20-21)(22-23)(24-25)

(26-27)(28-29)(30-31)

QUANT LOADING (4 C y)

QUAL CONCENTRAT (3 Cggy)

AgAE S SAMP E

"($NN"

$ (64-N (6 N >

uMITS UNITS CHLORINE, TOTAL

< 0.1

< 0.1 OCONTIPI MEASURkMENT 3,,,

IJOUS RESIDUAL 50060 1

0

/* 2

^

g. 5 MG/L 1CONTI)lj x

PERMIT

? NTH AVG LDLYiMAX

'JOUSs 6

M EFFLUENT GROSS VALUE REQUIREMENT HEAT (SUMMER) 77 144 OCONTIP CALCTD MEASURk,ENT 3,,,

1JOUS (PER HOUR)

M CONTI)lCALCTD PERMIT:- -

fREPORT 443 MBTU/

1******

L******

s 31386 2

1 3-EFFLUENT NET VALUE REQUIREMENT-

. MNTHtAVG DLY: MAX HR

-w DJOUS; MEAhuRhENT Nk NT x

M RE MEAkbR ENT

~REQU EMENT MEAkbR ENT lREh$REENTC MEAhbR ENT RJS$NbT:

MEAS R ENT e

D

REQU NTi TELEPHONE DATE EXAMi g NAME/ TITLE PRINCIPAL EXECUTIVE OFr!CER I

I O

A I S A F

kN'M " h 3

f "UI

ROBERT J.

HOVEY ggu N (roNm 509 339-3463 94 09 22 AND HERE G-GENERAL MANAGER g,g g gCCUR j g

gP gCgAL N

PR ME A

IGNAT EPOSgl hyeak.)

HOPE CREEK OPERATIONS y

Ohb0 and/or maximen inprisonment of between 6 [nonths U OR D AG N CODE NUMBER TEAR MO DAY TYPED OR PRINTED SAMPLING FOR CO, ZN, & CR IS REQUIRED ONLY IF MAINTENANCE CHEMICALS CONTAINING THESE METALS ARE USED. IF NOT USED, ENTER " NODI" FOR THESE METALS.

EPA Form 3320-1 (Rev. 9-88) Previous editions may be used.

LABS: 08153 17451 77535 06431 11118 PAGE 5 or 12

fT] I g. g ji1 { g 57 ten (LPDES)

PER;iliTEE EAP'E/A00RESS RAT 1Out i

E$-19)

(I N)

CAME PSEEG AODIESS P.O.

BOX 23_ G/N_21 NJ0025411 461C HANCOCKS BRIDGE NJ 08038 PERMIT NUMBER DISCHARGE NUMBER n

MONITORING PERIOD LOW VOLUME WW SYSTEM FACILITY PSEEG HOPE CREEK GENERATING STATI YEAR M0 DAT YEAR MO DAY MAJOR SALEM

_________________ON,,

LOCATION LOWER ALLOWAYS CREEK NJ 08038 94 08 01 94 08 31 SOUTHERN REGION n

DMR NUMBER: 081994 (20-21)(22-23)(24-25)

(26-27)(28-29)(30-31)

(3C*d.gy) WANijg{,g) LOADING (4Cag,gy) wAL(({,g)CONCENTRATkN-61)

NO.

FRgQ.

2 A440YSIS TYP bf UNITS UN!TS

) (64-68)

(69-7U)

TEMPERATURE, WATER

  • uu*
  • mu
  • ueu D.2 M.0 MMMGM 3,,,tg DEG. CENTIGRADE FEASUREMENT fEEKLYGRABj 00010 1

1

. REPORT

~ REPORT DEG.C pgg,,

J EFFLUENT GROSS VALUE REQUIREMENT'

-MNTH AVG

-DLY7 MAX PH 8

8 MMM' GW S,M,L, MEASUREMENT 00400 1

0

-6

.9 SU UfEEKLYGRAB-

. ppg,7 EFFLUENT GROSS VALUE REQUIREMENT MINIMUM

' MAXIMUM SOLIDS, TOTAL 7

8 OTWICE/ COMPOS sap

](ONTH SUSPENDED MEASUR ENT TWICE/ COMPO8 00530 1

0 1******

730 3100 MG/L z

. pg, p.

REQUIR MENT-

.MNTH! AVG fDLYlMAX 11(ONTH EFFLUENT GROSS VALUE HYDROCARBONS,IN H20,

< 0.2

< 0.2 OTWICE/

GRAB 3g,g

)(ONTH IR,CC14 EXT. CHROMAT MEASUREMENT TWICE/ GRABJ EFFLUENT GROSS VALUE REQUIRfMENT L******

L10 115 MG/L 00551 1

0

. pg, f -

1MNTHfAVG TDLYkMAX.

C(ONTH NITROGEN, AMMONIA nuo nun unu 1

1 MKWQMM 3,g,g MEASURkMENT jiONTH TOTAL (AS N) ppg,,.

[35 JREPORT MG/L

TWICE/ COMPOS 2******

00610 1

0 c

)(ONTH EFFLUENT GROSS VALUE REQUIREMENT-'

3MNTHtAVG iDLYEMAX 4

CARBON, TOT ORGANIC 18 18 OTWICE/ COMPOS MEASURhENT

)(ONTH Sep (TOC) 00680 1

1 E******

2****** ****

1******

REPORT

... 950 MG/L HTWICE/ GRAB;'

PEm171 EFFLUENT GROSS VALUE REQUIREMENT-

  • MNTHpAVG IDLYFMAX (ONTH COPPER, TOTAL 0.1 0.1 OTWICE/ GRAB MEASURhENT

](ONTH 3g, (AS CU)

L******

1******

1******

? REPORT

g. 2 MG/L (TWICEj GRABf>

01042 1

0 pgg,, s..

EFFLUENT GROSS VALUE REQUIREMENT 1:MNTHTAVG

^FDLY? MAX R40 NTH TELEPHONE DATE OQ g i

RSON g EXAMIN p

i I

L NAME/ TITLE PRINCIPAL EXECUTIVE OFFICER g ks g

ROBERT J.

HOVEY ONy} guh gg NDIVID g Q M DI 509 339-3463 94 09 22 hjgActVR AD I

f A

E g.

GENERAL MANAGER SIGN E gPRgC L

Up

/N ND R

ME 1

gEPOSgl HOPE CREEK OPERATIONS 5.0hb0 and/or maxinun imprisonment of between [ months and h yeak.)

kuHORZkDAGhT CODE NUMBER YEAR MO DAY TYPED OR PRINTED

    • Please refer to the attached Transmittal sheet addenda EPA Form 3320-1 (Rev. 9-88) Previous editions may be used.

LABS: 08153 17451 77535 06431 11118 PAGE 6 0F 12

S TEM (TPOES) gigggjlgyg $1 -19)

PERutTTEE NAmE/ ADDRESS NaftoNAL NAME POEEG 16)

ADDRESS P.O.

BOX 23_6/N_21 NJ0025411 461C NJ 08038 PERMIT NUMBER DISCMARGE NUMBER

_ _ _HANCOCKS__BRIDGEn MONITORING PERIOo LOW VOLUME WW SYSTEM TEAR MO DAY YEAR MO DAY MAJOR SALEM 3C@T{P[E{G }O[E _CR1E{ G]N[R@I[G]ST[T[ON,,,

toCafiou LOWER ALLOWAYS CREEK NJ 08038 94 08 01 94 08 31 SOUTHERN REGION r

DMR NUMBER: 081994 (20-21)(22-23)(26-25)

(26-27)(2ft 29)(30-31)

CONCENTRAT (3Cg,gy) QUANT g g LOADING (6 Cggy)

QUAL)Q O

ANaf 15

    • N "k$bY UNITS UNITS 63 (64-N)

(6h-f0)

IRON, TOTAL 1.40 1.52 OTWICEf GRAB MEASURkkENT MONTH Sw (AS FE) 01045 1

0

,g,4 REPORT cREPORT MG/L TWICEfGRABi EFFLUENT GROSS VALUE REQUIREMENT 3MNTHTAVG

/DLYYMAX MONTH FLOW, IN CONDUIT OR 0.05 0.14 OpONTIN MEASURkENT UOUS 3,,,

THRU TREATMENT PLANT 50050 1

0 ENT

. L. 4 5 MGD E******

DCONTIN!'

pg,,,y jOUS:

EFFLUENT GROSS VALUE REQUIREMENT JMNTH.! AVG DLYnMAX kkkENT MEA REQU$!EMENT::

ME!NRkkENT REQU EMENT RkENT MEA x

s s

RkOU E EMil RkhENT ME

REQu!ENkNT1 RkENT ME
REQU$R NT5; y

S TELEPHONE DATE QA Ig Egig j

Igb g L

NAME/ TITLE PRINCIPAL EXECUTIVE OFFICER ON lJ, h ]g y g 01 ID y h DI Q g j g, h hE f g E

y ROBERT J.

HOVEY g/

t hy,pg,gCguRgAND h k gag

-509 339-3463 94 09 22 NE E RE S g GENERAL MANAGER Sig gPRgCgAL HOPE CREEK OPERATIONS E POS I Y

ND PR ME A

0 bb0 and/or maximtn uprisonment of between 6 M ths and h yeak.)

UTHDRIZ!D AG T CODE NUMBER YEAR MO DAY TYPED OR PRINTED EPA Form 3320-1 (Rev. 9-88) Previous editions may be used.

LABS: 08153 17451 77535 06431 11118 PAGE 7 0F 12

PERMITTEE EAME/ ADD':ESS EATIONAL Q TANT ji g g igNy g YSTEM (NPDES)

(E N)

(N-19)

KAME PSEEG ADDRESS P.O.

BOX 23GfN_21 NJ0025411 462A HANCOCKS BRIDGE NJ 08038 PERMIT NUMBER DISCHARGE NUMBER n

MONITORING PERim NORTH STORM DRAIN YEAR M0 DAY YEAR MO DAT MAJOR SALEM FACILITY PSE&G HOPE CREEK GENERATING STATION,,,

LOCATION LOWER ALLOWAYS CREEK NJ 08038 94 08 01 94 08 31 SOUTHERN REGION n

DMR NUMBER: 081994 (20-21)(22-23)(24-25)

(26-27)(28-29)(3D-31)

QUAL CONCErTRAT (4 C g g y)

QUANT LOADING (3 C g g y) p y

SAMPgE PggR Eg UNITS UNITS d) (64-15)

(6ND) 7.6 7.6 0

ONCE/

GRAB PH MEkSUR l(ONTH ENT t******

r******

d6.0 i.* * * * *

  • j9.'O. SU 40NCE/r GRABr 00400 1

0

, ppg,, L J"

2 MAXIMUM H(ONTH SMINIMUM 7

EFFLUENT GROSS VALUE REQUIREMENT-SOLIDS, TOTAL 16 16 0 ONCE/ GRAB 3,,,

MEASURkMENT

(ONTH SUSPENDED

.. R E P O ilT. MG/L t0NCEf GRABpj' 00530 1

1 (ADMIN) pgg,7:..

, ycREPORT t******

t******

EFFLUEN" GROSS VALUE REQUIREMENT'

?MNTH/ AVG cDLYl MAX

l(ONTH HYDROCARBONS,IN H20,

< 0.2

< 0.2 0 ONCE/ GRAB-3 MEASURk,ENT

)(ONTH 3,,,

IR,CC14 EXT. CHROMAT M

pg,,,,

.. :: REPORT

_. {15, MG/L

}..0NCE/< GRAB;*3 7******

r******

1******

00551 1

0

~

EFFLUENT GROSS VALUE REQUIREMENT:'

fMNTHXAVG SDLY? MAX J)(ONTH

+

CARBON, TOT ORGANIC 16 16 0 ONCE/

GRAB 3,,,t,

)(ONTH (TOC)

MEASUREMENT 00680 1

1

pggg, ;

. 4REPORTg ;n. 'f5.0 MG/L (ONCEf; GRABgA 11******

t******

i******

EFFLUENT GROSS VALUE

. REQUIREMEN T.E

-CMNTH ? AVGVDLYs MAX N(ONTH FLOW, IN CONDUIT OR 0.261 0.261 O

ONCE/'

MEASURk,ENT

(ONTH 3,,,

THRU TREATMENT PLANT M

. vREPORT JREPORT MGD H.******

c.* * * * *

  • E * * *.* * *. ****

40NCE/f

^'-

K 50050 1

0

_R&pg,,7 c 9(ONTH QUIREM&NTE LMNTHIAVG

'DLYfMAX EFFLUENT GROSS VALUE MEk k ENT

'. N5 ikN lnEQulRIT1-s eses '

PERM MENT:

MEA MENT

'f dP

,. EI T

x TELEPHONE DATE gS gEXAMI p

A I A NAME/ TITLE PRINCIPAL EXECUTIVE OFFICER QE Ig Lg OQ ROBERT J.

FOVEY g7Q, Qu gg g,gg NDI Ig M

y g

pCUR A

L' AM A REgRES

/

!!;09 339-3463 94 09 22 gg GENERAL MANAGER kPoSgIghOkF I

& AND MPRI NT. SEE 1 C

AND IGNA{ r OF PR b

NUMBER YEAR M0 DAY AL HOPE CREER OPERATIONS TYPr+, ;j DRINTED D h D and/of b @rmmi N N N f N N I @ and Sa$.E Auk b D A SAMPLES TO BE TAKEN DURING A DISCHARGE EVENT, EXCEPT FOR PET HC FOR WHICH SAMPLES SHALL BE TAKEN DURING THE IST PRECIPITATION EVENT OF MONTH WHICH CAUSES DISCHARGE DURING WORKING HR8 & IS PRECEDED BY MINIMUM DRY PERIOD OF 72 HRS.

EPA Form 3320-1 (Rev. 9-88) Previous editions may be used.

LABS: 08153 17451 77535 06431 11118 PAGE 8 OF 12,

l PERMITVEE CAME/A000ESS NAV104AL TACT]Iggigug SYSTEM (CPDES) 1 (N)

D-19)

NAME PSEEG ADDRESS P.O.

BOX 236/N21 NJ0025411 462B

[

HANCOCKS BRIDGE NJ 08038 PERMIT NUMBER DISCHARGE NUMBER n

MONITCRING PERIOD SEWAGE W.W.

FACILITv PSEEG HOPE CREEK GENERATING STATION,

TEAR MO DAT TEAR MO DAT MAJOR SALEM LOCATICQ LOWER ALLOWAYS CREEK _NJ 08038 94 08 01 94 08 31 SOUTHERN REGION f

DMR NUMBER: 081994 (20-21)(22-23)(24-25)

(26-27)(28-29)(30-31)

(3 C g g y) QUANT g g LOADING (4 C y)

QUALg,gCONCENTRATg 2

ersis (65')

5

'tWE" h3)

UNITS UNITS

=(64-68) v

=

BOD, 5-DAY 96.8 96.8 728.0 728.0 0 ONCEj GRAB (20 DEG. C)

MEASURNENT

)(ONTH 3,,

4 00310 G

0

pgg; 3 REPORT gg REPORT KG/

'E******

..fREPORT pgREPORT MG/L pp)MCE/; GRABF RAW SEW / INFLUENT REQUIREMENT 2 *MNTHiAVG 7DLYFMAX DAY VMNTHMAVG MSDLYfMAX dl(ONTH s d'W BOD, 5-DAY l

1.8 1.8 13.5 13.5 0 ONCEj GRAB (20 DEG. C)

"MEASURNENT

](ONTH Sw,

? REPORT gjREPORT MG/L

0NCE/t GRABg i

pg, 7.y.

.s y6.0 y 1.3 REPORT-' KG/

':s * * * * *

  • it 00310 1

0

' ~ ' 4MNTHIAVG "'L DLY9 MAX t)(ONTH

%Me EFFLUENT GROSS VALUE REQUIR MENT! EMNTH? AVG 1 12)LY kMAX DAY PH 7.1 7.7 OTWICEj GRAB MEASURhENT WEEK 3,,

EFFLUENT GROSS VALUE Rk5NE Nf3

~

^

' <E******

OP 3640 % A******

am&#a9 so SU FWWICEj GRABM u

w ^

9******

00400 1

0 NNh(INIMUM WD M E DSMAkIMUM MtEEKD MED

'R4 '

4 SOLIDS, TOTAL 278 278 0 ONCEj COMPOS SUSPENDED MEASURhENT MONTI:

i 3,,

REPORT! MG/L *t0NCE// COMPOS 3 REPORT, @dLYfMAX-Q2******

n******

Mh!^ 2* *M U

^MNTHIAVG 00530 G

0 3 -- k'kNTd

+

?

Yl(ONTHI '9 W RAW SEW / INFLUENT

>RE x

SOLIDS, TOTAL

<1

<1 0 ONCEj COMPOS SmP SUSPENDED MEASUR ENT MONTI:

4 4

00530 1

0 gg 1.

.f.****** gq**"*UD x

s 8****5,? ! q;&; J30 gigOg100, MG/L Q0NCE/j COMPOS EFFLUENT GROSS VALUE GREQUIREkNTE%b '

      • s' WMNTH$ AVG 54DLY@ MAX 91tONTH ' *dW 4

+

OIL AND GREASE

<1

<1 O ONCEj GRAB MEASURkEMENT MONTI:

SMP FREON EXTR-GRAV METH

          • : ;gg.s gg10 e ;,15'; D15.. MG/L 90NCE/j GRABq p *2b "

00556 1

0 ggg ig e*.**** : g ******%

N "MNTHEAVG 2>DLY MAX NI(ONTH W"D EFFLUENT GROSS VALUE 1 REQUIREMENT $' ' ' #$ iidS M FLOW, IN CONDUIT OR 0.026 0.048 O DAILYFLOIND THRU TREATMENT PLANT MEASURkEMENT SMP PROAILYJ FLOIND Mi SWiy R**N@SE 5 **

NS5YE Y 50050 1

0

- - " < " VWcREPORT 1 WREPORTL MGD T******

K * * *.* *
  • EFFL_UENT GROSS VALUE /REQU MENkh )DITHIAVG $skDLYlMAX EYEIS #

' M@Ein?

CAME/YlTLE PRINCIPAL EXECUTIVE OFFICER I CERTIFT UNDER LYO AW THAT I H RSONA Y EXAMINED TELEPHONE DATE AND AM FAM lAR HE N QRMAT ON T

ilASED l

1:oR ROBERT J. HOVEY ON MT NQu F

i I Ai. IMM T

T 04 NFORMAdOMALI 04 L VE i Rf M

TAI NG N

E ARE S c-L-

.509 339-3463 94 09 22

A AM A GENERAL MANAGER

}

AccVR}

HOPE CREEK OPERATIONS "E

I E

h T'."S b $5C [ N ND

{ A}

g, CgAL U

D AGENT ChE NUMBER TEAR MO DAT TYPED OR PRINTED 0,

and/or bxinnmnTupYrNNf'$N N sN h e$.I EPA Form 3320-1 (Rev. 9-88) Previous editions may be used.

LABS: 08153 17451 77535 06431 11118 PAGE 9 0F 12

[

SYSTEM (N# DES)

RATIONAL g TATT ]! g g lgr g D -19)

PERMITTEE NAME/ ADDRESS

($16)

__ _E _P__3._E_6G _ _ _ _ _ _ ___ _ _ _ _ _

NAM ADDRESS P.O.

BOX 23_6f_N21 NJ0025411 462B HANCOCKS BRIDGE NJ 08038 PERMIT NUMBER DISCMARGE WLMBER n

MONITORING PERIOD SEWAGE W.W.

~~

~~

~~

~

YEAR MO DAY TEAR M0 DAY MAJOR SALEM 3CILITY,_P1E&G,H_Ob3R1E[GE_NE_RA3I1G_ STlT[ON,,,

g NJ 08038 94 08 01 94 08 31 SOUTHERN REGION

,, LOWER ALLOWAYS CRE_EKr

-LOCATION DMR NUMBER: 081994 (20-21)(22-23)(26-25)

(26-27)(28-29)(30-31)

=,

(3 Cg,gy) QUANi g g l0ADING (4 C y)

QUAL CONCENTRAT "IE" Ih idW5 (6S' uNns uuns COLIFORM, FECAL

< 1

<1 0 ONCE/ GRAB Sw MONTf:

GENERAL MEASUR ENT c******

4400 E/100 n0NCE/j GRABLs

? PERM M

-M******

t****** : m.js ;200

. x 74055 1

0 iMONTEGEO iWKLY3GEO ML 6140 NTH h@

._ REQUIRkMENT4 35

  • 6e e c

EFFLUENT GROSS VALUE s

BOD, 5-DAY PERCENT 98.1 98.1 O ONCE/ CALCTD MEASuRFMENT MONTi:

REMOVAL S******" PERCE ; ;;0NCE/g CALCTD

?

4******

w!****** ****

  • i87;5 m REPORT 81010 K

0

,REENMENTI s

NT ihtONTH FM

'$MdNAVMIN : OAVERAGE M4" 7

PERCENT REMOVAL SOLIDS, SUSPENDED 100 100 O ONCE/ CALCTD MEASURhENT MONTI:

3,,,

PERCENT REMOVAL

['kQhAVMIN N AVERAGE s

PERCE iPONCE/g CALCTD 81011 K

0 2

fia*****

s 4******- ****

% 85 :' tREPORT

^

NT

'IllONTH T9@

- RE5NNEN[

M PERCENT REMOVAL OXYGEN DEMAND 2.2 2.2 16.2 16.2 0 ONCE/CALCTD SAMPLE MONTI:

FIRST STAGE MEASUREMENT 32210 1

0 a

08:2

& REPORT' KG/

V i******

r sREPORT byREPORT MG/L CONCE/i CALCTD MNTHEAVG,NDLYlMAX liltONTH EFFLUENT GROSS VALUE

?RE MT5 MNTHEAVG

'MifDLYTMAX DAY

~ +

MEASU MENT

.M" ^

N

~

I ~ NI ^

['kb T ^

')

?d?(<

' q.? -

? Nay['ti....

_s

REQUIREMENT?

i ss

[N

'V s

TiU w' @

$1%!M

MEkSU ENT g-t s

s

- > s q q.;

Fw N

' " JJ '

2' 'Y-

$y@EW W*

w.

..ss es fdE5Ndb..

' W5 YMR M

+

s MEAS MENT sg ig.:

g n,;,

W n+p,

~

in ~

s YN bl

[ hN *

. PE gNkf b

J

^ hi'

, }

f TELEPHONE DATE RSONA EXAMIN NAME/ TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER P LYO AW THAT I HA lD H R p ED l) t MATONSgM H

N AND AM FAM g[!ARW N g!

Ek$l k YR 1

j7, 4g,, E f

ROBERT J.

HOVEY ON,MT,t

,- /

,/

m 509 339-3463 94 09 22 h"{4u ACcuRAgANo G

AM AWARE GENERAL MANAGER

, HOPE CREEK OPERATIONS thI o! ]ET IlS M T!" E "$d uIC l No A j ATyhPRgC L

0,h0and/or sun k o

$$fN"M bN arid a$.E Z ED A bE NUMBER YEAR M0 DAY l

TYPED OR PRINTED EPA For1a 3320-1 (Rev. 9-88) Previous editions may be used.

LABS: 08153 17451 77535 06431 11118 PAGE 10 0F 12'

2T } 1 g g ig h g SYSTEM (NFCES)

Pt CITTEE NAME/ ADDRESS NATICtAL PO kb b-19)

CAME PSEEG ADc ESS P.O.

BOX 23G/N21 NJ0025411 4G3A HANCOCKS BRIDGE NJ 08038 PERMIT NUMBER DISCKARGE C: UMBER n

MONITORING PERico SOUTH STORM DRAIN TEAR MO I DAY YEAR MO DAY MAJOR SALEM TA'C@T{P[E{G }O[E 3R_EE[ GlNE_RA]ING STlTION g,,

LOCATION LOWER ALLOWAYS CREEK NJ 08038 94 08 01 94 08 31 SOUTHERN REGION r

DMR NUMBER: 081994 (20-21)(22-23)(24-25)

(26-27)(28-29)(30-31)

(3cm.niv) =^"Tm.%'o^oiac

(*cigg.giv)

=^'m.gg)mact"Ta*Tm.613

q. ANA0;YSIS

,R o

$h 62 1

UNITS UNITS

3) (64-68)

(69-, )

l PH 7.4 7.4 0 ONCE/

GRAB 3,,,

MEASURkMENT MONT1[

16.0

9.0 SU LONCE/c GRABi 00400 1

0

. pg,g MAXIMUM

")(ONTH EFFLUENT GROSS VALUE

. REQUIREMENT 1 LMINIMUM,'

SOLIDS, TOTAL 86 86 0 ONCEj GRAB 3,,,g MONTI:

SUSPENDED MEASUREMENT 00530 1

1 (ADMIN)

REPORT

? REPORT MG/L 1ONCE/:. GRABi

. pg,y.

EFFLUENT GROSS VALUE REQUIREMENT

-? MNTH 9 AVG (DLY? MAX i MONTH O

1 0 ONCEj GRAB-3 HYDROCARBONS,IN H20, 3,,,tg MONTil IR,CC14 EXT. CHROMAT MEASUREMENT 00551 1

0

-REPORT K15 MG/L

'ey 0NCE/7 GRAB-3

,_ pg,g,7

.MNTHJAVG eDLYEMAX 1 MONTH-EFFLUENT GROSS VALUE

-REQUIREMENT ~

I CARBON, TOT ORGANIC 17 17 0 ONCE/

GRAB SAMPLE MONTI:

(TOC)

MEASUREMENT 00680 1

1 x******

A******

^ :. REPORT 450 MG/L

' s.ONCE/; GRABS

.pg,g,7 EFFLUENT GROSS VALUE

REQUIREMENT:
MNTHiAVG tDLYJMAX MONTH FLOW, IN CONDUIT OR 0.282 0.282 O ONCE/

3,,pt, MONTI:

THRU TREATMENT PLANT MEASUREMEkT 70NCE/;

50050 1

0 ypg,gy,.

.LREPORT T REPORT. MGD 2******

t******J ****

s

' MONTH EFFLUENT GROSS VALUE

. REQUIREMENT: 'MNTHiAVG 2DLY MAX MEAsbENT RE MENTI MEAS ENT s

eM RE ENT-A I S

TELEPHONE DATE ZAME/ TITLE PRINCIPAL EXECUTIVE OFFICER QEgt Ig N Lg OQAW g EXAMi g I

DI R

S g, g NDI

'509 339-3463 94 09 22 ROBERT J.

HOVEY ON,g,g y h g gCcuR AND Pg 4 g h}kfEEgRESgap#

PR g AL GENERAL MANAGER E

1 AN N

P,R ND POSgl

_ p HOPE CREEK OPERATIONS 0,b0 and/or maxinun mprisonment of between monthsandhyeak.)

UTHORIZED A T

CODE NUMBER YEAR MO DAY TYPED OR PRINTED SAMPLES TO DE TAKEN DURING A DISCHARGE EVENT, EXCEPT FOR PET HC FOR WHICH SAMPLES SHALL BE TAKEN DURING THE IST PRECIPITATION EVENT OF MONTH WHICH CAUSES DISCHARGE DURING WORKING HRS & IS PRECEDED BY MINIMUM DRY PERIOD OF 72 HRS.

EPA Ferm 3320-1 (Rev. 9-88) Previous editions may be used.

LABS: 08153 17451 77535 06431 11118 PAGE 11 OF 12

r SYSTEM (NPOES)

IgW tATIONAL ffTAN I

($$6)

D-19)

PERMITTEE NAME/ ADDRESS NAME PSEFS NJ0025411 4G4A ADDRESS P.O.

BOX 236/N_21 DISCHARGE NUMBER PERMIT NUMBER NJ 08038 HANCOCKS BRIDGEn MONITORING PERIOD PERIM STORM DRAIN YEAR MO DAY YEAR MO DAY MAJOR SALEM 3C@T{P1E{G ]O3 3R[E[ GlN[RA]IlG] T}T3 N,,,

LotATioN LOWER ALLOWAYS CREEKrNJ 08038 94 08 01 94 08 31 SOUTHERN REGION (20-21)(22-23)(24-25)

(26-27)(28-29)(30-31)

DMR NUMBER: 081994 (3 C g g y) ouANi g g LOADING (6 Cggy) ouALg,gCONCENTRATg g

H 0

SAMP[E M$ $N (6NO)

ER UNITS PA ' #

UNITS 7.7 7.7 0 ONCE/

GRAB MONT}:

PH MEASURk!ENT Sw s******

2*****E ****

B6;0 c******

......... 29.0 SU st0NCE/m GRABi x

'RENNfENT5 iMINIMUM

" MAXIMUM

!(ONTH.

00400 1

0 EFFLUENT GROSS VALUE 16 16 0 ONCE/

GRAB 00 LIDS, TOTAL MONTI:

MEAk k ENT

~

_m m p mp m*

muu LREK M

. W.MR MS fWW4 GMf SUSPENDED 00530 1

1 (ADMIN)

EFFLUENT GROSS VALUE SEQUIREMENTc.

9MNTHUAVG

'DLYyMAX J40 NTH

\\

pg,g,y _ _

s

< 0.2

< 0.2 0

ONCE/ GRAB-3 HYDROCARBONS,IN H20, MONTI:

MEASURkhENT 3,,p IR,CC14 EXT. CHROMAT

. J15j MG/L WONCE// GRAB-3

?.jREPORT 5****** ****

E******'

MNTHiAVG

  1. DLYfMAX
(ONTH-

'd 00551 1

0

-PERMlU EFFLUENT GROSS VALUE Rt0UIREMENT!

20 20 0 ONCE/

GRAB CARBON, TOT ORGANIC MONTI:

3,,,

MEAsURkENT 1*.*****

^

4******- ****

3******

... JREPO.RT

., 3 5 0.. MG/L 10NCE& GRAB)

(TOC) 00680 1

1 pg,,,, g ;

!MNTlDAVG XDLYlMAX

$l10 NTH EFFLUENT GROSS VALUE

- REQUIREMENT!

O ONCE/

FLOW, IN CONDUIT OR 0.368 0.368 MONTI[

THRU TREATMENT PLANT MEks k!ENT EFFLUENT GROSS VALUE >REQUIR MENT%MNTHiAVG

?DLY? MAX s -

@4 M ~ x(@

2 * * * *.*

  • MiONCE//

PERM 'C d(REPO.RT 1 REPORT MGD d******

(ONTH 50050 1

0 a

MEkshkMENT E @$

[R !

NIk M *>

s-4 s

MEks$EhENT

^

N N

$JPERM1'Y1 -

~

O-

^

JREQUIREMENTl

^

> #IM TELEPHONE DATE

%AME/ TITLE PRINCIPAL EXECUTIVE OFFICER ERjlgtg Lg 0 AWgA If g

gEXAMig (

I1 Dg 509 332-3453 94 09 22 ONglNQukY E01 S

FOR gIAbbRhSDNL AUR

t. I E 5 gRE S Hogg N F

ROBERT J.

HOVEY GENERAL MANAGER Ok

& N5 M R T'. S h" O C IPAL gP D

IGN HOPE CREEK OPERATIONS "E

EDAhN NUMBER YEAR MO DAY l

Sq E $f N N 7 M b andb yes$.f kHOR 0 and/of NEn.nl EXCEPT FOR PET HC FOR WHICH SAMPLES SHALL BE TAKEN DURING TYPED OR PRINTED 0

CAMPLES TO DE TAKEN DURING A DISCHARGE EVENT, IS PRECEDED BY MINIMUM THE 1ST PRECIPITATION EVENT OF MONTH WHICH CAUSES DISCHARGE DURING WORKING HRS T PAGE 12 0F 12 DRY PERIOD OF 72 HRS.

LABS: 08153 17451 77535 06431 11118 EPA Form 3320-1 (Rev. 9-88) Previous editions may be used.