ML20072S569

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Mar 1991 for Farley Nuclear Plant Unit 2
ML20072S569
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 03/31/1991
From: Dennis Morey, Woodard J
ALABAMA POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9104160350
Download: ML20072S569 (5)


Text

.__ ____ _ _

Auau,a ros,... cma i,

' e u,ew s c,.mc ca.aa,.

POM ON e B,.12%

Ottfrinif: eq. Alat un a ;>'

l i

  • lo.ept v,e 205 !!M 5,i!$

i L

A o w m>ooro Alabama Power me r ew, am %c f H' icy PfleKt 7f} }{

}ggg

/Y, A ff d f ' liftl' 8C fe' Docket No. 50-364 V. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washitgton, D. C.

20555 Joseph M. Farley Nuclear Plant Unit 2 Monthly Qneratina Data ReDort Attached is the March 1991 Monthly Operating Report for Joseph M. Farley Nuclear Plant Unit 2, as required by Section 6.9.1.10 of the Technical Specifications, if you have any questions, please advise.

Respectfully submitted, h

wtk'd

'J.

. Woodard AEJ:edb3014 Attachments

  • Mr. S. D. Ebneter Mr. S. T. Hoffman Mr. G. F. Maxwell

.-. san 9104160350 910331 PDR ADOCK 05000364 J

fe R

PDR e

k

l 4

JOSEPH M. FARLEY NUCLEAR Pl. ANT UNIT 2 NARRATIVE

SUMMARY

OF OPERATIONS March, 1991 There were no unit shutdowns or significant power

  • eductions during the month of March.

No major safety-related maintenance was performed during the month of March.

l.-

l.

.w.

OPERATING DATA REPORT DOCKET NO. 50-364 DATE April T, T771 COMPLETED BY D. N. Morey TELEPfl0NE (205)B99-5156 OPERATING STATUS Notes

1. Unit Name Joseph H. Faricy - Unit 2
1) Cumulative data since
2. Reporting Period March 1991 7-30-81, date of
3. Licensed Thermal Power (HVt):

2,652 commercial operation.

4. Nameplate Rating (Gross MVe):

860

5. Design Electrical Rating (Net HWe) _ 829
6. Maximum Dependable Capacity (Gross HVe):

864.2

7. Maximum Dependable Capacity (Net MVe):

824.0

, 8. If Changes Occur in Capacity Ratings (Items Number 3 'through 7) Since Last Report, Give Reasons: N/A

9. fover Level To Vhich Restricted, 11 Any (Net HVe):

N/A

10. Reasons For Restrictions, If Any:

N/A This Ponth Yr-to-Date Cumulative

11. Hours In Reporting Period 744 2160 84,769
12. Number of Hours Reactor Vas Critical 744.0 2093.7 72,477.9
13. Reactor Reserve Shutdovn Hours 0.0 0.0 138.0
14. Hours Generator On-Line 744 2029.5 71,580.7
15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross Thermal Energy Generated (HVH) 1,971,550 5,174,885 152,378,834
17. Gross Electrical Energy Generated (HVU) 647,184 1,694,238 59,900,194 l
18. Net Electrical Energy Generated (MVH) 617,116

~~,608,444 ~ 56,802,566 1

19. Unit Service Factor 100 94.0 84.4
20. Unit Availability Factor 100 94.0 84.4
21. Unit Capacity factor (Using HDC Net) 100.7 "757%

81.8

22. Unit capacity Factor (Using DER Net) 100.1 89.8 80.B_
23. Unit Forced Outage Rate 0

0 4.2

24. Shutdowns Scheduled Over Next 6 Honths (Type, Date, and Duration of Each):

N/A

25. If Shut Down At End Of Report Period, Estimated Date of Startup: N/A
26. Units In Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY 05/06/81 05/08/81 INITIAL ELECTRICITY 05/24/81 05/25/81 COMMERCIAL OPERATION 08/01/81 07/30/81 Form 2/30

DOCKET No.

50-364 UNIT 2

DATE April 3, 1991 COMPLLL"" BY D. N. Morey TELEP110NE (205)899-5156 MONTH Hr.r ch DAY AVERAGE DAILY POVER LEVEL DAY AVERAGE DAILY POVER LEVEL (HVe-Net)

(MVe-Net) 1 827 17 831 2

,827 18 829 3

830 19 834 4

E36 20 835 5

835 21 829 6

829 22 824 7

826 23 823 8

831 24 831 9

833 25 833 10 810 26 831 11 833 27 825 l

12 831 28 823 13 827 29 821 14 833 30 836 15 835 31 835 16

,833 1

lisSTRL 7TIONS On this format, list the average daily. unit power level in MVe-Net for each day in the reporting month. Compute to the nearest whole megavatt.

j-Form 13/21

tNIT mM AND POW 8 4 REIUCTIo43 COCIZT fe.

50-364 tNIT M:U=I

.7. M. FWE - tNIT 2 DATE April 3. 1991 Cors*. fred si c W.PCFET REPORT ? ORTH PORCH TEZZFIORE (203)S99-5156 L

I I

i l "Ermo oF 1 trcEMsEE I I

I c msE s - -

I I

I I

I ounrrow I I smrrm iEmr isrsrEnI - -

I mas m i

im.

I DarE I TrrE I (nes) 1RExsos2, y,,,m y,3,,,,,,,, cc,<

gco,,s i

l I There were no unit shutdmms or significant power redtsetions dt: ring the enth of Mards.

I I

I I

I I

i 1

I I

I i

l i

i i

I I

I I

I I

I I

I I

i i

1 I

i i

i I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I i

i i

i i

i i

i l

i i

i i

i l

I i

l i

i i

i i

i i

i l

l I

i 1

1 I

I i

l I

I I

I I

I I

I I

I I

I I

I i

l i

i i

1 1

I I

I I

I i

l i

i i

l i

i i

i I

I I

I I

I I

I I

I I

I I

I I

I 1

i l

I I

i i

i i

l I

1 I

I I

i i

I i

i i

i i

l I

i l

i I

I i

i i

I l

1 i

I i

i I

i i

i i

l i

I i

l I

I i

i i

i I

I i

i i

i i

i I

i i

i i

l i

l I

i i

i i

l i

i i

i i

l I

i i

i i

F: Forced Reason:

9stbod:

Exhibit G-Ittstructions 5: Schedtaled A-Equipment railure (Explain) 1-Mantzal ftT Preparat2ee of Data 5-Ma13tenance or Test 2 stanual seren.

Entry Sheets for f.icensee C-Refueling 3-Aszttzmatic Scras.

Event Report (IZR) File (ICCREG-D-Regulatory Restriction 4-Cther (Explain) 0161)

E-operator Training & License Examinatican F-W inierative Exhibit I -sasse Sor_cco G-operational Error (Explain)

H-other (Explain)

-