Interim Deficiency Rept Re Possibly Altered Hj Kaiser (Hjk) Welding Procedures.Initially Reported on 821217.HJK Review in Progress.Two Addl Cases of Unauthorized Alterations Identified.Next Rept Will Be Provided Under Item M-29
ML20072S328
Person / Time
Site: Zimmer
Issue date: 03/29/1983
From: Borgmann E
CINCINNATI GAS & ELECTRIC CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
10CFR-050.55E, 10CFR-50.55E, LOZ-83-0004, LOZ-83-4, NUDOCS 8304070110
Download: ML20072S328 (2)


Text

r

]

I THE CINCINNATI GAS & ELECTRIC COMPANY mK~ l CtNCINN ATf, OHIO 45200 March 29, 1983

,jf;By7 ANN LOZ-83-0004 Docket No. 50-358 U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 61037 Attention:

Mr. J.G. Keppler Regional Administrator Gentlemen:

RE:

WM. H.

ZIMMER NUCLEAR POWER STATION - UNIT 1 10CFR50. 5 5 (e) - ITEM M POSSIBLY ALTERED WELDING PROCEDURES W.O.

57300, JOB E-5590, FILE NO. 956C, M-73 This letter constitutes an interim report concerning the subject condition initially reported to the Commission on December 17, 1982 as a potentially reportable deficiency under 10CFR50.55(e).

A comprehensive program for the identification and resolution of deficiencies related to unauthorized alteration of Henry J.

Kaiser Co.(HJK) welding procedures has been developed by the CG&E Nuclear Engineering Department (NED).

This program will identify unauthorized alterations, document these alterations on the appropriate deficiency document, identify potential impact on safety related hardware, propose resolutions, and evaluate the proposed resolutions for code and technical acceptability..

A detailed review of all HJK welding procedures and currently available supporting documentation is being accomplished by the HJK Welding and Quality Engineering Departments concurrent with an independent review by the CG&E Quality Confirmation Program (QCP).

The QCP review has to date identified two additional cases of alledgedly unauthorized alterations of HJK welding procedures and has identified these on Condition Evaluation Requests 83-42 and 83-48.

8304070110 830329 APR 4 m PDR ADOCK 05000358 S

PDR 7Ea7

b Mr. J.G. K pplor Regional Administrator March 29, 1983 LOZ-83-0004 Page 2 Following the reviews for identification of any additional unauthorized alterations of welding procedures, CG&E Quality Engineering will combine the results of the two reviews and document any deficiencies on Corrective Action Requests.

The impact of these deficiencies on safety related hardware and the development of resolutions to these deficiencies in accordance with the FSAR commitments will be addressed by a Task Force comprised of Sargent & Lundy, CG&E Nuclear Engineering and Quality Assurance Departments, and HJK Welding and Quality Engineering Departments.

This procedure review program is being combined with the program established for resolution of 10CFR50.55 (e), Item M-29, Lack of Weld Procedure Qualification.

Subsequent reports on the status of this review and evaluation will be provided under Item M-29.

We trust the above will be found acceptable as an interim report under 10CFR50.55 (e).

Very truly yours, THE CINCINNATI GAS & ELECTRIC COMPANY E.A. BORGMANN SENIOR VICE PRESIDENT RNT/GMO/PMM/bcf cc:

NRC Office of Inspection & Enforcement Washington, D.C.

20555 NRC Senior Resident Inspector Attn:

W.F.

Christianson NRC Zimmer Project Inspector Region III

.