ML20072S275
| ML20072S275 | |
| Person / Time | |
|---|---|
| Site: | Rhode Island Atomic Energy Commission |
| Issue date: | 08/24/1994 |
| From: | Tehan T RHODE ISLAND, STATE OF |
| To: | Mendonca M Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 9409140018 | |
| Download: ML20072S275 (1) | |
Text
l
~
j D ',,..
E E
STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS l
l RHODE ISLAND ATOMIC LNERGY COMMISSION Nuclear Science Center South Ferry Road M~agansett, R. 1.02882 August 24, 1994 Docket No. 50-193 Mr. Marvin Mendonca, Senior Project Manager Non-Power Reactors, Decommissioning and Environmental Project Directorate Division of Reactor Projects - III/IV/V U.
S.
Nuclear Regulatory Commission Washington, DC 20555
Dear Mr. Mendonca:
This letter concerns revision of the technical specifications to more clearly define allowed reactor operation without the particulate or gaseous stack effluent monitor in service. After discussion with Mr. Tom Dragoon of Region One, it was determined that one shift is the normal limit for reactor opera: ion without these monitors.
Therefore, it is proposed that section 3.7.1 be changed to read the following:
The particulate activity monitor and the gaseous activity monitor for the facility exhaust stack shall be operating. If either unit is out of service for more than one shift (6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />), either the reactor shall be shut down or the unit shall be replaced by one of comparable monitoring capability.
If there are any questions regarding this change, please call me at 401-789-9391.
S,incerehy,
/t Ip
/
W
St*
Ter
- Tehan Dir.ctor TT:cd cc: Tom Dragoon, Region One h
i0 9409140018 940924 PDR ADOCK 05000193 P
_.PDR 4