University of Illinois Department of College of Engineering Nuclear Engineering at Urbana-Champaign 214 Nuclear Engineering 217 333-2295 Laboratory 217 333-2906 fax 103 South Goodwin Avenue Urbana, IL 61801-2984 August 19, 1994 Docket No. 50-356 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission ATrN: Document Control Desk Mail Station PI-137 Washington, DC 20555

Dear Sir,

Subject:

Annual Report, LOPRA Reactor License No. R-117 Docket No. 50-356 The following is written to comply with the requirements of Section 6.7.f of the Technical Specifications and conditions of 50.59 of 10CFR50. The outline follows the numbered sequence of Section 6.7.f of the Technical Specifications.

Respectfully,

/

/,

/

Richard L. Ilolm Reactor Supervisor c k Y $ N a s t,q -

Daniel F. Ilang V

Director, Nuclear Reactor Laboratory (h

/I[

/i 4 W&

Ilarclay G. Jones,Ilead, Departmeg of Nuc!c/

/

ar Enginneering ec: Region 111 USNRC e r.

a,;,. ; u d 9408310326 440731 PDR ADOCK 05000356 R

PDR

r l

i STATE OF ILLINOIS COUNTY OF CIIAMPAIGN i

Richard L. Ilolm, being first duly sworn on oath, deposes and says that he has affixed his signature to the letter above in his official capacity as Reactor Supervisor, University of

]

lilinois Nuclear Reactor Laboratory; that in accordance with the provisions of Part 50 Chapter

1. Title 10 of the Code of Federal Regulations, he is attaching this affidavit; that the facts set forth in the within letter are true to his best information and belief.

m Richard L. If6Im Reactor Supervisor Subscribed and sworn to before me, a,,N, otary Public, in and for the County of Champaign, State of Illinois, thiscdy,May of August

,A.D.,1994

/f&f h$

Npary Public of Illinoi My Commission Expires F

,,___,,l l " OFFlCI AL SEAL" ll K ATHLEEN M. DYSART 0l l

l NOTARY PUBUC. STATE OF ILLINDIS lI g MY COMMISSION EXPIRES 8A9/96ll
j l

J

, _..- =.

ILLINOIS LOPRA REACTOR - ANNUAL REPORT August 1,1993 - July 31,1994 Facility License R-117

1. SUMM ARY OF OPERATING EXPERIENCE The reactor was in operation a total of 11.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> during the period. This includes time when the reactor was operated for surveillances where the reactor was not actually critical The total operating time for the period was due to fulfilling surveillance requirements.

II. TABULATION OF OPERATIONS Surveillances 11.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> flours Critical

  • and Energy 9.7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> 0.0049 Mw-hrs l
  • This includes time where the reactor was sub-critical during the control rod calibration. Virtually all of the energy generated was due to the power calibration surveillance.

Ill. EMERGENCY SilUTDOWNS AND INADVERTENT SCRAMS One inadvertant scram occurred during the period initiated by the gamma mo litor. During the daily checklist the scrarn setting on the monitor is downscaled to initiate a scram, however in this instance the operator failed to return the scram setpoint to normal and hence scrammed the reactor on startup.

IV. M AINTENANCE A significant amount of effort was spent on repairs to the Keithley microammeter and the linear power strip chart recorder.

V.

CONDITIONS UNDER SECTION 50.59 OF 10CFR50 There were no changes to procedures, new experiments, or 50.59 reviews performed during the reporting period.

VI., Vll., Vill. RADIOACTIVE RELEASE / RADIATION EXPOSURE Because of the low power and infrequent use of the LOPRA, its operation does not contribute to the release of eftluents. Personnel radiation exposures for the laboratory are given in the Annual Report for the Advanced TRIGA Reactor, License No R-IIS, Docket No. 50-151, dated February 4,1994.

l l

j i