ML20072D995

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept on Item M-40 Re Indeterminate Heat Treatment for Small Bore Pipe.Initially Reported on 820422. Required Corrective Action Contingent on NRC Approval or Release of 821112 Order
ML20072D995
Person / Time
Site: Zimmer
Issue date: 06/14/1983
From: Williams J
CINCINNATI GAS & ELECTRIC CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
10CFR-050.55E, 10CFR-50.55E, 10JCFR-50.55E, LOZ-83-0043, LOZ-83-43, M-40, NUDOCS 8306230472
Download: ML20072D995 (2)


Text

..

i ii e

N!6 g

THE CINCINNATI ' GAS & ELECTRIC COMPANY CINCINNAT1, OHIO 4520t June 14, 1983 LOZ-83-0043 4

J. WILUAMS,.JR sENION VICE PRESIDENT NUCLEAR OPERATIONS Docket No. 50-358 U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137 Attention:

Mr. J.G. Keppler Regional Administrator Gentlemen:

RE:

WM. H. ZIMMER NUCLEAR POWER STATION - UNIT 1 10CFR50.55(e), ITEM M-40, INDETERMINATE i.

HEAT TREATMENT FOR SMALL BORE PIPE W.O. 57300, JOB E-5590, FILE NO. 956C, M '

I This letter constitutes an interim. report concerning the I

subject condition initially reported to the Commission on April 22, 1982 as a potentially reportable deficiency under the l

requirements of 10CFR50.55 (e).

As stated in our previous report, LOZ-83-0015, dated April 12, 1983, CG&E intends to perform destructive tests to determine the heat treatment-for samples of the four heats of piping listed i

on Nonconformance Report (NR) E-4337.

Construction Work Authorization Requests (CWAR's) 86 through 89 have not been approved as of'this date to perform this work.

Completion of testing and required corrective actions are contingent upon NRC approval of the CWAR's or release of the NRC

' November 12, 1982 " Order to Show Cause and Order Immediately Suspending Construction".

A follow-up report will be submitted at that time.

1 JUN 2 01983 8306230472 830614 PDR ADOCK 05000358 S

PDR

.. -.. ~.

..-....E.

Mr. Keppler Regional Administrator June 14, 1983 LOZ-83-0043 Page 2

We ' trust the above will be found acceptable as an interim report under 10CFR50.55 (e).

Very truly yours, THE CINCINNATI GAS & ELECTRIC COMPANY By J8 :' ; m WILLIAMS, JR.

ENIOR VICE PRESIDENT DJS/FSH/sfr cc:

NRC Office of Inspection & Enforcement Washing ton, D.C.

20555 NRC Senior Resident Inspector ATTN:

W.F. Christianson NRC Zimmer Project Inspector Region III t

{

l f

v t

. -. -