ML20072D437
| ML20072D437 | |
| Person / Time | |
|---|---|
| Site: | Fermi |
| Issue date: | 03/16/1983 |
| From: | Tauber H DETROIT EDISON CO. |
| To: | Youngblood B Office of Nuclear Reactor Regulation |
| References | |
| EF2-61-967, GL-83-08, GL-83-8, NUDOCS 8303210336 | |
| Download: ML20072D437 (1) | |
Text
-
. Harry Teuber
-- Geoup Vice Preedent c
Phrch 16, 1983 EF2 - 61,967 Mr. B. J. Youngblood', Chief Licensing Branch No. 1 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555
Dear Mr. Youngblood:
References:
(1)
Enrico Fermi Atomic Power Plant, Unit 2 NRC Docket No. 50-341 (2)
NRC Generic Letter 83-08, " Modification of Vacuum Breakers in Mark I Containments",
February 2, 1983 (3)
Detroit Edison to NRC letter, " Submittal of Reports for the Fermi 2 Vacuum Breakers", EF2-60,296, November 9,1982
Subject:
Fermi 2 Vacuum Breakers The Reference 2 generic letter requested that the plant unique calculations for the Fermi 2 vacuum breakers be submitted for Staff review as well as a schedule for any modification.
This information was provided in Reference 3 Should you have any additional questions, please con-tact Larry E. Schuerman, (313) 649-7562.
Sincerely, Nf cc:
Mr. B. Little g gC) i Mr. M. D. Lynch P
B303210336 830316 PDR ADOCK 05000341 A
-