l I

GPU Nuclear Corporation u Nuclear

=neeSs48o Middletown, Pennsylvania 17057 717 944-7621 TELEX 84-2386 Writer"s Direct Dial Number:

June 6, 1983 5211-83-163 Regional Administrator Region I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406

Dear Sir:

Three Mile Island Nuclear Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 LER 83-003/01T-1 and 82-011/99X-1 This letter transmits update Licensee Event Reports Nos. 83-003/0lT-1 and 82-011/99X-1 concerning evidence of corrosion found on RC-V2 (PORV).

The-information provided in the attached updated reports serves to supplement the previous reports (dated March 7, 1983 and October 28, 1983 respectively) and closcout the issue of the source of the PORV's corrosion and our correc-tive actions to preclude future corrosive attack.

Sincerely, 1

$. D. Huk 11 Director, TMI-l HDH: CJS:vj f Enclosure cc:

J. Van Vliet R.

Conte Document Management Branch 8306210247 830606 gDRADOCK 05000289 PDR g

GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation I

{