ML20071Q013
| ML20071Q013 | |
| Person / Time | |
|---|---|
| Site: | Perry |
| Issue date: | 12/21/1982 |
| From: | Edelman M CLEVELAND ELECTRIC ILLUMINATING CO. |
| To: | Youngblood B Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 8212290189 | |
| Download: ML20071Q013 (1) | |
Text
THE CLEVELAND ELECTRIC ILLUMIN ATING COMPANY P.O. BOX 97 m PERRY, OHIO 44081 m TEL EPHoNE (216) 259-3737 a ADDRESS-10 CENTER ROAD Serving The Best Location in the Nation December 21, 1982 Mr. B. 3. Youngblood, Chief Licensing Branch No.1 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C.
20555 Perry Nuclear Power Plant Docket Nos. 50-440; 50-441 Confirmatory issue No. 44 Radiation and Shielding Design of IFTS Tubes
Dear Mr. Youngblood:
This letter is provided in response to the Perry SER confirmatory issue number 44, regarding radiation and shielding design of the inclined Fuel Transfer System (IFTS) tubes. The radiation and shielding design information of the IFTS tubes is provided in Amendment 10 to the Perry FSAR and may be found on pages 12.3-11 and 12.3-1la, and Figure 12.3-21.
We believe that this letter and the information provided in Amendment 10 to the Perry FSAR should resolve this confirmatory issue in the next Supplementary Safety Evaluation Report.
Very truly yours, b
Murray R. Edelman Vice President Nuclear Group MRE:kh cc:
Jay Silberg, Esq.
John Stefano Max Gildner M. LaMastra 0
8212290189 821221
$0 PDR ADOCK 05000440 E