ML20071P850
| ML20071P850 | |
| Person / Time | |
|---|---|
| Site: | 05200003 |
| Issue date: | 07/29/1994 |
| From: | Liparulo N WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP. |
| To: | Borchardt R NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| Shared Package | |
| ML19304C463 | List: |
| References | |
| NTD-NRC-94-4225, NUDOCS 9408100214 | |
| Download: ML20071P850 (2) | |
Text
r-r I
Westinghouse Energy Systems Bm 355 Pmbmgh PennsyNania 15230 0355 Electric Corporation NTD-NRC-94-4225 DCP/NRC0152 Docket No.: STN-52-003 July 29,1994 Document Control Desk U.S. Nuclear Regulatory Cotamission Washington, D.C. 20555 ATTENTION:
MR. R. W. BORCHARDT
SUBJECT:
OUICK LOOK DATA REPORT FOR AP600 LONG TERM COOLING TESTS AT OREGON STATE UNIVERSITY: MATRIX TEST SB04
Dear Mr. Borchardt:
Enclosed with this letter is a report describing the results of tests performed at the AP6001.ong Term Cooling Test Facility at Oregon State University. This Quick Look Data Report (OLR) summarizes the test conditions and measured data for matrix test SB04.
The purpose of these data reports is to provide the NRC staff with information on AP600 matrix tests of sufficient depth to enable early evaluation and analysis of test results.
An electronic copy of the test data included in the OLR is provided as Enclosure 2 on a single 4mm data cartridge. The test data files are ASCII files which were archived on the data cartridge using Palindrone Network Archivist" Version 2.0f.
The OLR and data cartridge contain Westinghouse proprietary information and is identified as prelirninary. This information will be incorporated in the Final Test Report. With the publication of the Final Test Report, the preliminary identification will be removed and a non-proprietary version of the Final Test Report will be prepared.
The Westinghouse Electric Corporation copyright notice, proprietary information notice, application for withholding and affidavit are attached.
This subrnittal contains Westinghouse proprietary information consisting of trade secrets, commercial information or financial information which we consider privileged or confidential pursuant to 10CFR2.790. Therefore, it is requested that the Westinghouse proprietary information attached hereto be handled on a confidential basis and be withheld from public disclosures.
l II f i ^)
(, u,v, A 4
~
04 xg y A o
c 9408100214 940729 PDR ADOCK 05200003 A
NTD-NRC-94-4225 DCP/NRC0152 July 29,1994 This material is for your internal use only and may be used for the purpose for which it is submitted.
It should not be otherwise used, disclosed, duplicated, or disseminated, in whole or in part, to any other person or organization outside the Commission, the Office of Nuclear Reactor Regulation, the Office of Nuclear Regulatory Research and the necessary subcontractors that have signed a proprietary non-disclosure agreement with Westinghouse without the express written approval of Westinghouse.
Correspcmdence with respect to the application for withholding should reference AW-94-684, and should be addressed to N. J. Uparulo, Manager of Nuclear Safety Regulatory And Ucensing Activities, Westinghouse Electric Corporation, P.O. Box 355, Pittsburgh, Pennsylvania, 15230-0355.
Please contact Drian A. McIntyre on (412) 374-4334 if you have any questions concerning this transmittal, kYff p
N. J. Uparulo, Manager Nuclear Safety Regulatory And Ucensing Activities
/nja Enclosures Attachments cc:
T. Kenyon, NRC (w/o Enclosures)
R. Hasselberg, NRC (4 copics of Enclosure 1,1 copy of Enclosure 2)
G. D. McPherson, NRC (Enclosure 1)
A. Levin, NRC (Enclosure 1)
L Shotkin, NRC (Enclosure 1)
P. Boehnert, ACRS (Enclosure 1)
B. A. McIntyre, Westinghouse (w/o enclosures / attachments) mu
-