. _.
Commonwrith Edison c
LaSalle County Nuclear Station 67,3-3f3 Rural Route #1, Box 220 V'
Marseilles, Illinois 61341 Telephone 815/357-6761 September 10, 1982 James G. Keppler Regional Administrator Director of Regulatory Operations - Region 111 U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen EM yn. Illinois 60137
Dear Sir:
In accordance with LaSalle County Station Unit 1 Facility Operating License NPF-ll, Appendix B, Section 3.2, we are submitting to you a copy of the NPDES noncompliances for LaSalle County Nuclear Generating Station Permit No. 1 LOO 48151.
G J. Diederich Superintendent LaSalle County Station M
GJD/FRL/JGW/j fe Enclosure i
cc: DVR Report 8209270126 820910 SEp g g 1982 PDR ADOCK 05000373 S
N
- Commonwealth Edison
) RuralRouta #1 Box 220LaSalla County Nuclear Station c
~.
(U Marseilles,lilinois 61341 Telepnene 815/357-6761 September 10, 1982 U. S. Environmental Protection Agency Region V, Enforcement Division ATTN: Chief, Compliance Unit 230 South Dearborn Street i
Chicago, Illinois 60604 1
Illinois Environmental Protection Agency Division of Water Pollution Control Compliance Management Unit l
2200 Churchill Road Springfield, Illinois
SUBJECT:
NPDES Noncompliances For LaSalle County Nuclear Generating i
l Station - Permit No. 1L0048151
Dear Sir:
In accordance with Standard Condition 12, we wish to submit the following notice of noncompliances, which are listed chronologically in the attached table.
I f
If there are any questions, please contact Joe Williams of my staff at (815)-
357-6761, extension 201.
l. k h-G J. Diederich Superintendent LaSalle County Station GJD/
/JGW/j f e cc: Director of Water Quality, Environmental Affairs Manager, Nuclear Stations Division I
e---
.--.m
_. - -... _ -.. _ _,. ~. _ _. _
s LASALLE COUNTY NUCI. EAR GENERATING STATION N.P.D.E.S. PERMIT NO:
ILOO48151 NONCOMPLIANCE REPORT DISCHARGE NUMBER AND DESCRIPTION:
001c Low Volume Waste Radwaste Discharge Tanks PARAMETER AND PERMIT LIMIT: Total suspended solids - 15 mg/l Total Iron - 1.0 mg/l NONCOMPLIANCE, DATE, AND DURATION:
Total Copper-1.0 mg /l No sampling and analysis Aug. 16 - Aug. 22, 1982, not applicable f
CAUSE OF NONCOMPLIANCE:
The composite sampler cannot operate automatically. The operator did not inform the Chemistry Technician that the discharge was taking place until after it had been initiated.
In another case the operator failed to inform the Technician that the discharge had been secured.
CORRECTIVE ACTION:
The Operating Department has been informed to notify the Rad / Chem Technician prior to initiating the discharge. and prior to securing the discharge.
In addition a work request has been initiated to automatically start and stop the composite sampler.
DATE RECOGNIZED AS A VIOLATION:
August 22. 1982 DATE INVESTICATED:
August 25, 1982
-- -.