Text
p u.-. m;p - eq f
TIIIC CINCINNATI G AS & ICI,ICCTitIC CO A1I*A N Y d"
NI O
Cf'4CIN N ATI O HIO 4 5206 April 15, 1982 QA-1703 U. S. Nuclear Regulatory Commission g
O Region III 799 Roosevelt Road g
Glen Ellyn, Illinois 60137 f
RECEIVED
.I
-II Attention:
Mr. J. G. Keppler APR 261982> :.
Regional Administrator N EcmIman masse IIWut ummer a g,p RE:
WM. H. ZIMMER NUCLEAR POWER STATION UNIT I TIDC 10CFR21 - ITEM S DEFECTIVE STRUCTURAL STEEL - DOCKET NO. 50-358, CONSTRUCTION g
N PERMIT NO. CPPR-88, W.O. #57300 JOB E-5590 FILE NO. NRC-9, ITEM S-2 Gentlemen:
This letter constitutes our report concerning the subject defect origi-nally reported by Mr. B. R. Sylvia of CG6E to Mr. T. P. Gwynn of the NRC under the requirements of 10CFR21.
On April 12, 1982, llenry J. Kaiser Company, principal constructor of the Zimmer Station, informed the Quality Assurance Department of CC&E of a possibly reportabic defect in 3x3x A-36 Angle Iron, manufactured by Northwestern Steel
& Wire Company. Laminations of approximately 1/8" in depth and 1/32" wide were observed in 260 ft. of material from heat #66221.
Ini-tal indications reveal that this defect is isolated to
!,e above re-ferenced heat. At this time, the constructor and vendor are investigating this matter. The constructor is in the process of accounting for all material of this heat to assure that it is removed from the plant and properly segregated.
A final report concerning this defect will be issued by May 31, 1982.
We trust the above will be found acceptable as an interim report under 10CFR21.
Very truly yours, Tile CINCINNATI GAS & ELECTRIC COMPANY R 2 04 2 tom n 6 p 6 a. o p sy B. R. SYLVIA b
VICE PRESIDENT NUCLEAR OPERATIONS FKP:ac cc: NRC Resident Inspector Attn:
W. F. Christianson NRC Of fice of Inspection & Enforcement Washington, D.C.
20555 APR 21 1982, R / 7 S 'il