- _
+
S e.
l Nortli North Atlantic Energy Service Corporation 4
r.O. ne, 300 Atlantic Seabrook, N1103874 o
(603) 474-9521, Fax (603) 474 2987 The Northeast Utilitien System Ted C. Feigenbaum NYN. 94076 Senior Vice President &
Chief Nuclear Officer July 15,1994 United States Nuclear Regulatory Conunission Washington, D.C. 20555 Attention:
Document Control Desk
References:
(a)
Facility Operating License No. NPF-86, Docket No. 50-443 (b)
North Atlantic Letter NYN-93037 dated March 3,1993, " Response to NRC Bulletin No. 90-01, Supplement I, (TAC M85411)", T. C. Feigenbaum to USNRC (c)
Teleconference between Mr. V. L. Rooney and Ms. D. W. Spaulding, USNRC and Mr. J. M. Peschel, North Atlantic, on June 24,1994
Subject:
Response to Request for Additional Infonnation (TAC M85411)
Gentlemen:
North Atlantic Energy Service Corporation (North Atlantic) provides in the Enclosure the additional information requested by the NRC Staff [ Reference (c)]. Should you require any additional information regarding this matter please contact Mr. James M. Peschel, Regulatory Compliance Manager, at (603) 474-9521, extension 3772.
Very truly yours, 3
Ted C. Feigenb im TCF:JMP/sm Enclosure N!W, p'
9407220096 940715
/
l PDR ADDCK 05000443
/}
g Q
~
\\
United States Nuclear Regulatory Commission July 15,1994 Attention:
Document Control Desk Page two 4
cc:
Mr. Thomas T. Martin Regional Administrator United States Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 Mr. Albert W. De Agazio, Sr. Project Manager Project Directorate 1-4 Division of Reactor Projects U.S. Nuclear Regulatory Commission Washington, DC 20555 Mr. Antone C. Cerne NRC Senior Resident inspector P.O. Box i149 Seabrook, Nil 03874 i
4
North Atlantic July 15,1994 ENCI.OSUltE I TO NYN-94076 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION NRC BULLETIN 90-01, SUPPLEMENT 1 l
i I
l 1
RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION NRC BULLETIN 90-01, SUPPLEMENT 1 l
NRC Ouestion The response to Bulletin 90-01, Supplement I, does not specify the frequency of the enhanced surveillances fo items addressed in the response to NRC-requested actions le and If. Please provide the frequencies for the surveillance of these transmitters.
North Atlantic Response As stated in the response to Bulletin 90-01, Supplement 1, NRC-requested Actions le and 1f, North Atlantic does not currently plan to exclude from the enhanced surveillance program, any transmitters in the categories described by NRC-requested actions le and If. North Atlantic currently performs the preventive actions of the enhanced surveillance program at least once every refueling cycle, with a maximum interval not exceeding 24 months, for transmitters that are in the categories described by NRC-requested actions le and If. This is the same surveillance frequency inat North Atlantic applies to the transmitters in the category described by NRC-requested action Ic.
e l
i h
t
-