ML20071B461

From kanterella
Jump to navigation Jump to search
Fourth Interim Deficiency Rept 54 Re Tube Steel (Ht 16600) Laminations.Corrective Action Described in Not Completed.Final Rept Will Be Submitted by 830318
ML20071B461
Person / Time
Site: Waterford Entergy icon.png
Issue date: 02/17/1983
From: Maurin L
LOUISIANA POWER & LIGHT CO.
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, 54, W3I83-0058, W3I83-58, NUDOCS 8302280329
Download: ML20071B461 (1)


Text

LOUISIANA P O W E R & L 1 G H T! R o. Box soos. NEW ORLEANS. LOUISIANA 70174 242 octARoNoe S m ter

. (504) 366-2345

$ U N 5YS E February 17, 1983

t. v. MAunin Vee President Nuclear Operations W3I83-0058 Q-3-A35.07.54 Mr ohn T. Collins, Regional Administrator U. S. Nuclear Regulatory Commission kp 611 Ryan Plaza Drive, Suite 1000 1

g 221983 n i:

Arlington, Texas 76012

SUBJECT:

Waterford SES Unit No. 3 1

Docket No. 50-382 Significant Construction Deficiency No. 54

" Tube Steel (HT 16600) Laminations" Fourth Interim Report

REFERENCE:

LP&L letter W3K82-0271 dated May 11, 1982

Dear Mr. Collins:

At the present time, the corrective action as described in the reference above has not yet been completed.

A final report will therefore be submitted by March 18, 1983.

Very truly yours,

//

/7 Nfaud L. V. Maurin LVM/ MAL:keh cc:

1) Director 3)

E. L. Blake Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, D. C.

20555

2) Director 4)

W. M. Stevenson j

Office of Management j

Information and Program Control U. S. Nuclear Regulatory Commission l

Washington, D. C.

20555 Y

B302280329 830217 PDR ADOCK 05000382 S

PDR