N Commonwealth Edison
[
) ona First National Plua, Chicigo, Ilknois (C } Address Reply to: Post Office Box 767 (j Chicago, lilinois 60690 February 23,-1983 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555
Subject:
Byron Station Units 1 and 2 Braidwood Station Units 1 and 2 FSAR Amendment 41 NRC Docket Nos. 50-454, 50-455, 50-456 and-50-457-
Dear Mr. Denton:
The application for construction permits and operating licenses for Byron Station Units 1 and 2 and Braidwood Station Units 1 and 2, docketed September 20, 1973, are hereby amended by submittal of Amendment 41 pursuant to 10 CFR 50.34.
Amendment No. 41 to the Byron /Braidwood FSAR consists of new responses to questions from the Auxiliary Systems Branch (010.0 series) and the Equipment Qualification Branch (271.0 series).
Also included are revised' responses to Questions 010.39, 010.44, 010.47, 010.57, 022.30, 022.54, 040.131, 040.172, 121.3, 212.3, 281.7, 321.42, 331.15, and 331.24 and voluntary text changes.
Attachment A to this letter lists the questions answered in this amendment.
Attachment B lists the questions that will be answered in future amendments.
Three signed originals and fifty-seven copies of this amend-ment are submitted for your use.
Please direct questions to this office.
Very truly yours, f,
Aduw T. R.
Tramm Nuclear Licensing Administrator 1m C)O [
SUBSCRIBED and SWORN to bef o re me ' thi s JJ//d ay of hw s 1982 y
Om o 4. h Notary PubTic
/ YO 6038N 8302280204 830223 PDR ADOCK 05000454 PDR K..
NRC~ Docket Nos.
50-454/455 50-456/457
' Attachment A List-of Questions-Answered in Byron /Braidwood FSAR Amendment-41 I.
Auxiliary Systems Branch (Series 010.55 - 010.59) 1
-The following questions have been responded-to in this amendment:
010.57_ parts c, d, and e 010.58.
II.
Equipment Qualification Branch (Series 271.1 - 271.3)
[
The following questions have been responded to in this
. amendment:
i 271.2-L 271.'3 l
l-J f
s f.'
4 J
n e-t#
r,-
e r
y-wm e
a~,
er e
, - ~
- - - ~
- O.
'NRC-Docket Nos. 50-454/455 50-456/457
~
Attachment-B List of Round One and'Round-
..Two Questions Not Answered In Byron /Braidwood FSAR Amendment No. 41 I.
~ Auxiliary Systems Branch (Series 010.0).
The following 3 questions will be answered in future-FSAR amendments:
010.60' through 010.62 (Braidwood)-
II.
Materials Engineering' Branch - (Series 121.0)
LThe.following 3 questions will be answered in future - FSAR amendments:
121.5 through 121.7, III.-
Structural Engineering Branch -(Series 130.0)
The following.3 questions'will be answered in future FSAR amendments:
i 1130.55 through 130.57 (Braidwood)
L IV.
Reactor Systems Branch (Series 212.0)
I The following 2 questions wil be answered in future FSAR amendments:
212.112 212.157 l-V.-
Hydrologic and Geotechnical Engineering Branch (Series 241.0)
The following 9 questions will be answered in future FSAR.
amendments:
I 241.1 through 241.8 (Braidwood) 241.8 (Pyron) i
~
l
.v-NRC. Docket Nos. 50-454/455 50-456/457 Attachment B (continued)
VI.-
Equipment Qualification Branch (Series 271.0)
The'following question ~will be answered in a future FSAR amendment:
271.1-VII.
Siting Analysis Branch (Series 330.0)
The following 2 questions will be answered in future FSAR mmendments:
330.1 (Braidwood) 330.2 (Braidwood).
VIII.
Geoscience Branch (series 361 and 362)
The following,9 questions will be answered in future FSAR amendments:
361.1 through 361.5 (Braidwood) 362.1 (Byron) 36%.1 (Braidwood) 362.10, 362.11 (Braidwood) i i
IX.
Hydrologic and Geotechnical Engineering Branch (Series 371.0) r l
(
The following 13 questions will be answered in future FSAR l
amendments:
371.1 through 371.19 (Braidwood) i X.
Meteorology and-Effluent Treatment Branch (Series 372)
The following 3 questions will'be answered in future FSAR l
l amendments:
372.21 through 372.23 (Braidwood) i i-
-