ML20071A955
| ML20071A955 | |
| Person / Time | |
|---|---|
| Site: | Fort Saint Vrain |
| Issue date: | 02/11/1983 |
| From: | Lee O PUBLIC SERVICE CO. OF COLORADO |
| To: | Jay Collins NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| P-83061, NUDOCS 8302250251 | |
| Download: ML20071A955 (1) | |
Text
__
\\
PUBLIC SERVICE COMPANY OF COLORADO f
p.
- o. s o x.4o oeuven, coton4oo.omoi February 11, 1983 q
OSCAR R. LEE
[gpt $t, ypgjg j D [ (p I vic' " *' '"'
Unit No. 1 P-83061 h @ @]"SI f' 7' l Mr. John T. Collins, Regional Administrator i P-A :
Nuclear Regulatory Commission
'T FEB i8 Em c.h
[\\
Region Iv i
Office of Inspection and Enforcement
{,
'J>J 611 Ryan Plaza Drive Suite 1000 L
Arlington, TX 76012
SUBJECT:
Fort St. Vrain CRDM Temperatures
REFERENCE:
NRC letter dated December 2,1982 Clark to Lee
Dear Mr. Collins:
Public Service Company of Colorado (PSC) has made a preliminary review of the referenced letter which requested a commitment to limit maximum Control Rod Drive Mechanism (CRDM) temperatures to 215 F and orifice valve position to a minimum open position of 40%.
Our preliminary review indicates that there does not appear to be a sound basis for these temperature and orifice valve position commitments.
Our preliminary review of the request for comitment appears to be
' negative; however, we request an extension to review this matter in depth.
PSC is now evaluating the report in detail and will submit our response by April 15, 1983.
Sircerely, a
SWW
- 0. R. Lee, Vice President Electric Production ORL/JRR:pa g
+
F302250251 830P11
~
PDR ADOCK 0500v267 p