Text
>o IUiLATED CORRESPONDENCB Filed: February 11, 1983Oc(ggyp 9
.:w-
'83 FEB 17 tito;53 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION before the ATOMIC SAFETY AND LICENSING BOARD
)
In the Matter of
)
)
PUBLIC SERVICE COMPANY OF NEW
)
Docket Nos. 50-443 OL HAMPSHIRE, et al.
)
50-444 OL
)
(Seabrook Station, Units 1 & 2)
)
)
APPLICANTS' THIRTEENTH MOTION FOR
SUMMARY
DISPOSITION (CONTENTION NECNP I.D.2)
Pursuant to 10 CFR $ 2.749, the Applicants hereby move for summary disposition of contention NECNP I.D.2.
This motion is submitted upon the affidavit of William N. Fadden which reveals that Seabrook's testing of protection systems will be in full accord with Reg.
Guide 1.22, compliance with which NECNP admits 8302180360 830211 PDR ADOCK 05000443 6
3.
d constitutes an acceptable method of compliance with GDC 21.
In addition, as set forth in the affidavit Task II.D.1 of NUREG-0737 relates only oo generic testing of relief values and has no applicability here.
Thus there remains no triable issue under NECNP I.D.2 and summary disposition of the contention is in order.
Respectfullv.mwbmit*,ed c-ffY
.![
Thomas G. Dignan, Jr.
R.
K. Gad III Ropes & Gray 225 Franklin Street Boston, Massachusetts 02110 Telephone:
423-6100 Dated:
February 11, 1983 l
l l
i 1
STATMENT OF MATERIAL FACTS AS TO WHICH THERE IS NO DISPUTE 1.
The applicants' testing of protection systems will be in full accord with Reg. Guide 1.22 including the criteria enumerated in Regulatory Position D.4.
l 1 _ _. _