Submits Special Rept 90-003 Re Results of Third Steam Generator Tube Inservice Insp.Total of 6,374 Tubes Inspected & Two Tubes Plugged in Steam Generator D.Tube Indications in Steam Generators B & D Listed
ML20070V285
Person / Time
Site: Wolf Creek 
Issue date: 04/03/1991
From: Bailey J
WOLF CREEK NUCLEAR OPERATING CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NO-91-0111, NUDOCS 9104110107
Download: ML20070V285 (6)


Text

. -.

_~...

I t

t WOLF CREFiK

' NUCLEAR OPERATING CORPORATION a

i John A Bailey V6f e President i

AprH 3,1991 NO 91-0111-i U. S. Nuclear Regulatory Counission ATTN: Document Control Desk Mail Station P1-137 Washington, D. C.

20555 Subject Docket No. 50-482:

Special Report 90-003 The attached Special Report is being submitted in accordance with Technical-Specification 4.4.5.5 b concerning the results of Wolf Creek Generating' Station's third' steam generator tube inservice inspection.

l

-Very truly_yours, b.

{

i

-John'A. Bailey-

h i

Vice President Operations-JABlaem i

Attachment cci A. T, Howell-(NRC), w/a R. D. Martin (NRC), w/a D.~V.- Pickett (NRC), w/a M. E. Skow (NRC), w/a l

,b t

910411010~/ 910409 e

e-1

  1. &s mmr eOx m I

PDR

_,,. - _.. _. _ - -__.~....-..,,..

  • - Attactynent to NO 91-0111 Pagd 1 of 5 SPICIAL REPCRP 90-003 THIRD STEAM GENERATT SUBE INSPICITCM RESUUIS This report is being subnitted pursuant to Technical-Specification (T/S) _ __

4.4.5.5.b and 6.9.2 to report the results of the third steam generator tube _

inservice inspection, i

The third steam generator tube inservice inspection was completed by

-Westinghouse Electric Corporation on April 4, 1990,-during Refueling Outage IV. This inspection included steam generators (S/G) "B" and "D".

This was the second inservice inspection of S/G "D" and the third for'S/G "B".

A total of 6,374 tubes were inspected, and a total of two tubes wem plugged' in S/G "D" as discussed in Special Report-90-001, which was transmitted by letter No 90-0114,: dated April 19, 1990. 1his inspection did not identify any tubes which were required to be plugged in-S/G "B".-_ Included-in this inspection effort wem._32 tubes -(seven in S/G "B" and 25 in S/G _ "D") which' had been previously identified as having-indications requiring re-inspection during this inservice inspection effort. The inspection results of these tubes am included with all indications found which are listed in Section'3 of this report.

-1.

Number and Extent of Tubes Inspected A.

Steam Generator "B":

- A total of 3,205 tubes wem inspected fullI 1

-length.

B.

Steam Generator "D":

A total of 3,169 tubes were-inspected-full l

length.-

I-2.

Identification of Tubes Plugged:

Row Column-A.

Steam Generator "B" None None B.

Steam Generator "D" S0-66

=45 101 i

t

i

-Attachment to N0 91-0111

_, Page 2 of-~5 l

-1 l

3.

Location and Percent of Will 'Ihickness Penetration' for I:ach. Indication of an Imperfection-(Note: Multiple listings of the same tube are the=

1 result of m re than one indication in that tube):-

j Kew Fbr Indicatice Lists

  1. H, #C

(# = number) of Support Plate Hot. Leg or Cold Ieg Side AV#

Anti-Vibration Bar (# = number)

P Tube Plugged, follcwing % of Wall.

t'

'Ihickness Loss Indication

% of WallIhickness-Ioss Inch (+)

Distance Measured.frun reference point' frun

.(AV Bar, Baffle Plate, W e Support.

Location Plate /etc.)_

Tube Indications in Steam Gmarator "B" i

Indication

-Inch'(+)

Row-Coltrnn Incation/Ima

(% of Wall '1hickness) -

Fran location :-

-i 30 10 AV5 20 0.00-46-25 AV4 21--

0.00 49 28 AVS 29 10.00-48

-35 AV3 27 0.00 53 35 AV5~

21 0.00-47 53 AV3

=23 0.00 54 55 AV2 28 0.00 l

54 55 AV3 20-0.00-54 55 AV5 32-0.00-50 58 AV2 30 0.00' 22 98 AV1 22 0.00 47 98 AV5 29 0.00 47 99 AV4 0.00=

47 99 AV6 29 0.00J 44 100 AV6 21-

-0.00 45 101

-AVS 26 0;00 44-102 AV4-25-

0. 00 --

44 102 AV6 35-0.00 41 104 A"5 22 0.00

'A,ttachment to NO 91-0111

'Page'3 of 5 Ybbo Irritcatlann.in Stmm Generator "D" Indication Inch (+)

How Colte location /Im

(% of Wall ThicknesgJ Pmn location 29 10 AVS 31 0.00 30 10 AV2 21 0.00 32 11 AV6 22 0.00 33 11 AV2 23 0.00 33 12 AV2 21 0.00 33 12 AV5 30 0.00 33 13 AV4 30 0.00 33 13 AVS 26 0.00 33 13 AV6 30 0.00 36 15 AVS 2't 0.00 37 15 AV4 37 0.00 36 16 AV4 29 0.00-37 16 AV4 26 0.00 37 16 AV5 22 0.00 38 16 AV6 20 0.00 39 17 AV2 29 0.00 39 17 AV3 30 0.00 39 17 KV4 28 0.00 39 17 AV5 27 0.00 41 19 AV2 29 0.00 41 19 AV4 21 0.00 41 19 AVS 30 0.00 41 19 AV6 25 0.00 42 21 AV3 30 0.00 42 21 AV5 37 0.00 42 21 AV6 30 0.00 44 21 AV3 30 0.00 44 21 AVS 36 0.00 44 21 AV6 30 0.00 41 22 AV6 22 0.00 44 23 AV3 30 0.00 44 23 AV4 22 0.00 44 23 AVS 22 0.00 44 24 AV4 34 0.00 44 24 AVS 34 0.00 45 24 AVS 33 0.00 48 26 AV4 23

-0.00 46 27 AV2 26 0.00 46 27 AV4 23 0.00 46 27 AVS 26 0.00 46 27 AV6 25 0.0C 49 28 AV5 27 0.00 49 28 AV6 28 0.00 51 31 AV4 20 0.00 53 33 AV2 21 0.00 53

'33 AV3 21 0.00

Attachment to NO 91-0111 Page & 6f 5 i

'B@c _Trrlications in Stxvim Generator D" (contirnn13 Indication Inch (+)

Row Column location /lfg I% of Wall 'Ihickness }

Prun Incation 53 33 AV4 31 0.00 53 33 AV5 26 0.00 53 33 AV6 33 0.00 39 34 AVI 24 0.00 45 47 AV2 28 0.00 45 47 AV3 33 0.00 45 47 AV4 27 0.00 52 47 AV5 34 0.00 52 47 AV6 21 0.00 45 48 AV3 32 0.00 50 52 AV3 29 0.00 50 52 AV4 33 0.00 47 58 AV2 28 0.00 45 62 AV2 31 0.00 45 62 AV3 32 0.00 45 62 AV5 24 0.00 45 64 AV2 25 0.00 45 64 AV3 36 0.00 r

45 64 AVS 21 0.00 59 64 AV2 26 0,00 50 66 AV2 28P 0.00 50 66 AV3 42P 0 00 50 66 AV4 30P 0.00 50 66 AV5 22P 0.00 50 67 AV3 34 0.00 50 75 AV2 30 0.00 50 75 AV3 27 0.00 l

53 76 AV3 20 0.00 57 77 AV6 25 0.00 50 81 AV2 25 0.00 l

50 81 AV4 31 0.00 l

50 81 AV5 28 0.00 56 81 AV2 27 0.00 49 82 AV2 28 0.00 1

50 82 AV3 33 0.00 l

50 82 AV4 23 0.00 50 82 AV6 22 0.00 55 83 AV3 29 0.00 40 84 AV2 27 0.00 45 85 AV2 20 0.00 45 85 AV3 34 0.00 51 89 AV3 25 0.00 51 89 AV4 22 0.00 45 94 AV3 26 0.00 45 94 AV4 27 0.00

Altt.cpnent to NO 91-0111 Sage 5 of 5

'Mo_ Trrlications.inJtmm Gernrator "D

(contintyd) i Infication Inch (+)

Row Colwtj[}

Location / leo B of Wall 'Thickneg'l Frun locatfor3 45 94 AV5 39 0.00 45 95 AV4 30 0.00 45 95 AV5 30 0.00 29 97 7H 21 70.39 45 97 AV4 30 0.00 45 97 AV5 39 0.00 48

./7 AV2 27 0.00 47 99 AV2 28 0.00 47 99 AV3 35 0.00 47 99 AV4 26 0.00 47 99 AV5 38 0.00 47 99 AV6 28 0.00 45 101 AV2 27P 0.00 45 101 AV3 24P 0.00 45 101 AV4 27P 0.00 45 101 AVS 42P 0.00 45 101 AV6 24P 0.00 44 102 AV5 26 0.00 40 105 AV3 32 0.00 40 105 AV4 29 0.00 35 109 AV4 28 0.00 36 110 AV1 22 0.00 36 110 AV2 37 0.00 36 110 AV6 25 0.00 30 114 AV5 28 0.00 28 115 AV6 24 0.00 1

,,.