Interim Deficiency Rept Re Lack of Installation Insp of non-Class IE Cables in Panels.Initially Reported on 821124. Revised Const & Insp Procedures Will Be Approved by 830228. Next Rept Will Be Submitted on 830729
ML20070T302
Person / Time
Site: Zimmer
Issue date: 01/25/1983
From: Borgmann E
CINCINNATI GAS & ELECTRIC CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
10CFR-050.55E, 10CFR-50.55E, QA-2232, NUDOCS 8302080291
Download: ML20070T302 (2)


Text

_ _-

a i* 'L a i e p- gg _ _A; n-

  • '= -=== : -w THE CINCINNATI GAS & ELECTRIC COMPANY W ~

CINCINN ATI. OHIO 45201 January 25, 1983 QA-2232 E. A. BORG MANN SENIOR */lCE MtESIDENT U. S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Attention: Mr. J. G. Keppler Regional Administrator RE: WM. H. ZIMMER NUCLEAR POWER STATION UNIT I 10CFR50.55(e) - ITEM E-30, LACK OF INSTALLATION INSPECTION OF NON-CLASS lE CABLES IN PANELS DOCKET NO. 50-358, CONSTRUCTION PERMIT CPPR-88 W.A. #57300 JOB E-5590 FILE E0. NRC-1, & E-30 Gentlemen:

Th!s letter constitutes an interim report concerning the subject deficiency reported under the requirements of 10CFR50.55(e). Our last report on this matter was submitted on November 24, 1982.

The report identified the corrective action that is being implemented to resolve this item. The status of each of the corrective actions is discussed below.

1. The Stop Work (82-05) issued on October 12, 1982, suspending the installation and termination of non-essential and associated cables in Category I structures is still in effect.

This order will not be rescinded until items 2 and 3 below are complete.

2. Construction and inspection procedures have been revised.

The procedures for cable pulling have been approved and issued. The procedures for Raceway Installation and Cable Termination are currently undergoing review. We anticipate that these procedures will be approved by February 28, 1983.

3. The contractor's construction personnel and QC inspectors will receive training on the construction and inspection procedure and the applicable design documents in accordance with the contractor's QA prograu. CG&E's QA personnel will assure compliance to this requirement. Training of the above personnel currently on site will be completed after the procedures are approved and issued so that work on non-essential systems can be resumed in accordance with Show Cause Order CLI-82-83.

8 FEB 3 84 1671

[S O

c o- 1 Mr. J. G. Keppler Regional Administrator Region III January 25, 1983 - QA-2232 Page 2

4. Procedures for the review of electrical separation of cables in essential panels are being prepared. We anticipate approval and implementation of these procedures by February 1, 1983. A preliminary schedule indicates completion of this review by June 30, 1983.

Our next report on this matter will be submitted on July 29, 1983.

We trust that this will be found acceptable as an interim report under 10CFR50.55(e).

Very truly yours, THE CINCINNATI GAS & ELECTRIC COMPANY By re---

g E. A. BORGMANN SENICR VICE PRESIDENT WPC:as cc: NRC Office of Inspection & Enforcement Washington, D.C. 20555 NRC Senior Resident Inspector Attn: W. F. Christianson NRC Zimmer Project Inspector Region III